{"product_id":"planet-igs-6325-4up2x-ip30-din-rail-industrial-l3-4-port-25gbase-t-8023bt-poe","title":"Planet IGS-6325-4UP2X IP30 DIN-rail Industrial L3 4-Port 2.5GBASE-T 802.3bt PoE +","description":"\u003cp\u003e\u003cstrong\u003e2.5Gbps Copper Ports with 802.3bt PoE++ Support and 10Gbps Fiber Ports Deliver High-speed PoE Networking \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET IGS-6325-4UP2X Industrial-grade, Multi-Gigabit L3 Managed PoE++ Ethernet Switch  features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour 2.5GBASE-T 802.3bt PoE++ ports\u003c\/strong\u003e, each of which can power up to\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e95\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewatts and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo 10GBASE-X SFP+ ports.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis switch comes in a rugged IP30 metal case and can withstand a temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e75 degrees C\u003c\/strong\u003e, making operation in the heavy industrial environment more stable.\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X supports rich PoE operation modes including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e90-watt 802.3bt type-4 PoE++ mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand 4-pair\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eforce mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto solve the incompatibility of non-standard 4-pair PoE PDs in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Power and Full-speed Data Delivered over 4-pair UTP Cabling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X is equipped with the IEEE 802.bt PoE++ technology, enabling it to provide up to 95 watts of power to each remote PoE compliant powered device (PD) using all four pairs of standard Cat5e\/6 Ethernet cabling for high power and full-speed data delivery. Compared to the conventional 802.3at PoE+, it offers triple power capacity, making it the perfect solution for higher power consuming PDs, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePoE PTZ speed dome cameras\u003c\/li\u003e\n\u003cli\u003eNetwork devices \u003c\/li\u003e\n\u003cli\u003eThin clients\u003c\/li\u003e\n\u003cli\u003eAIO (all-in-one) touch PCs, point of sale (POS) and information kiosks\u003c\/li\u003e\n\u003cli\u003eRemote digital signage displays\u003c\/li\u003e\n\u003cli\u003ePoE lightings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-1.png\" alt=\"\" width=\"700\" height=\"370\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-1.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e802.3bt PoE++ and Advanced PoE Power Output Mode Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo meet the demand for supplying stable PoE power to various powered devices, the IGS-6325-4UP2X Switch offers five different PoE power output modes for selection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e90W 802.3bt PoE++ Power Output Mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Pins 1, 2, 3, 6 + Pins 4, 5, 7, 8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e95W UPOE Power Output Mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Pins 1, 2, 3, 6 + Pins 4, 5, 7, 8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30W End-span PoE Power Output Mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Pins 1, 2, 3, 6)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30W Mid-span PoE Power Output Mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Pins 4, 5, 7, 8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60W Force Power Output Mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Pins 1, 2, 3, 6 + Pins 4, 5, 7, 8)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eONVIF Support Allows Effective and Centralized Control Over IP-based Security Products\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X switch offers ONVIF support as part of its versatile feature set for seamless integration with IP surveillance cameras. Through the switch's web GUI, users can easily search for and display all ONVIF-compliant devices on their LAN.\u003c\/p\u003e\n\u003cp\u003eUsers can also upload floor plans to the switch and place IP surveillance cameras on the plan for more intuitive planning and faster inspection in the future. Additionally, the web GUI provides real-time surveillance information, online\/offline status, and the ability to remotely reboot cameras.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-2.png\" alt=\"\" width=\"700\" height=\"371\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eIntelligent Alive Check for Powered Devices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X can be configured to monitor the status of connected powered devices (PDs) in real time through ping action. If a PD stops working and responding, the IGS-6325-4UP2X will recycle the PoE port power and bring the PD back to working condition. This greatly enhances reliability, as the assigned PoE port automatically reboots the PD, reducing the administrator's management burden.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_PD-Alive-Check.png\" alt=\"\" width=\"700\" height=\"336\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_PD-Alive-Check.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePoE Scheduling to Save Energys\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy implementing the \"PoE schedule\" function, businesses can reduce their energy consumption during non-business hours or periods of low network usage. This not only helps to reduce energy costs but also minimizes the overall carbon footprint of the organization.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the IGS-6325-4UP2X's PoE scheduling feature provides a convenient and easy-to-use interface for managing power usage. The user can easily set the time intervals for each PoE port, allowing for more efficient power management.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_PoE-Schedule-for-Energy-Saving.png\" alt=\"\" width=\"700\" height=\"253\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_PoE-Schedule-for-Energy-Saving.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScheduled Power Recycling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X enables connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. This will reduce the chance of IP camera or AP crashes resulting from buffer overflow.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_Scheduled-Power-Recycling.png\" alt=\"\" width=\"700\" height=\"337\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_Scheduled-Power-Recycling.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 Network Routing Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X allows administrators to boost network efficiency by configuring Layer 3 IPv4\/IPv6 VLAN static routing manually or automatically through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRouting Information Protocol (RIP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOpen Shortest Path First (OSPF)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esettings.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRIP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses hop count as a routing metric and prevents routing loops by setting a limit on the number of hops allowed in a path from source to destination.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOSPF\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an interior dynamic routing protocol for autonomous systems based on link state. The protocol creates a database of link states by exchanging link states among Layer 3 switches and then uses the Shortest Path First algorithm to generate a route table based on that database.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X is capable of advanced Layer 2 switch management functions, including dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping, and MLD snooping. By aggregating supporting ports, the IGS-6325-4UP2X can operate up to 3 high-speed trunk groups with multiple ports and fail-over support.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_Robust-Layer-2-Features.png\" alt=\"\" width=\"700\" height=\"217\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_Robust-Layer-2-Features.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X supports the\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eModbus TCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol, allowing for easy integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCADA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, and other data acquisition systems in factory floors. This enables administrators to remotely monitor the industrial Ethernet switch's\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eoperating information\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eport information\u003c\/strong\u003e, communication status, and DI\/DO status, thereby enhancing monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X supports redundant ring technology and has strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eITU-T G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology, Multiple Spanning Tree Protocol (IEEE 802.1s MSTP), and a redundant power input system into customer's industrial automation network, enhancing system reliability and uptime in harsh factory environments. In a simple ring network, the data link recovery time can be as fast as 10ms.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_PoE-switch-ERPS.png\" alt=\"\" width=\"700\" height=\"510\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_PoE-switch-ERPS.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1588 Precision Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X is ideal for implementing precision time Ethernet applications. It is competent to play an undeniable role in an IEEE 1588 and synchronous Ethernet network by supporting MEF service delivery and timing over packet solutions.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-3.png\" alt=\"\" width=\"700\" height=\"467\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-3.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSMTP Event Alert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X supports SMTP event alert function to help quickly determine whether a device malfunction results from a network disconnection, or a rebooting response.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-4.png\" alt=\"\" width=\"700\" height=\"441\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-4.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEffective Alarm Alert for Better Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time to find where the problem is. It will help to save time and effort.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-5.png\" alt=\"\" width=\"700\" height=\"282\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-5.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Input and Digital Output for External Alarm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to inform the administrator the IGS-6325-4UP2X’s port status including link down, link up or power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-6.png\" alt=\"\" width=\"700\" height=\"574\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-6.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor efficient management, the IGS-6325-4UP2X is equipped with console, Web and SNMP management interfaces. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the built-in Web-based management interface, the IGS-6325-4UP2X offers an easy-to-use, platform-independent management and configuration facility. \u003c\/li\u003e\n\u003cli\u003eFor text-based management, it can be accessed via Telnet and the console port. \u003c\/li\u003e\n\u003cli\u003eFor standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-7.png\" alt=\"\" width=\"701\" height=\"232\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/IGS-6325-4UP2X-7.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-4UP2X supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP and SFP+ transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\" alt=\"\" width=\"700\" height=\"350\" class=\"img-fluid\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49628\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 10\/100\/1G\/2.5GBASE-T RJ45 copper ports with 802.3bt PoE++ Injector function\u003c\/li\u003e\n\u003cli\u003e2 10GBASE-SR\/LR SFP+ slots, compatible with 1G\/2.5GBASE-X SFP\u003c\/li\u003e\n\u003cli\u003eOne RJ45-to-RS232 console interface for basic management and setup\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedly Reliable \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual power input, redundant power with reverse polarity protection\n\u003cul\u003e\n\u003cli\u003eDC 48 to 54V input\u003c\/li\u003e\n\u003cli\u003eActive-active redundant power failure protection\u003c\/li\u003e\n\u003cli\u003eBackup of catastrophic power failure on one supply\u003c\/li\u003e\n\u003cli\u003eFault tolerance and resilience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN-rail and wall-mount designs\u003c\/li\u003e\n\u003cli\u003eIP30 aluminum case \u003c\/li\u003e\n\u003cli\u003eSupports 4KV DC Ethernet ESD protection.\u003c\/li\u003e\n\u003cli\u003e-40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Input and Digital Output \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 digital inputs (DI)\u003c\/li\u003e\n\u003cli\u003e2 digital outputs (DO)\u003c\/li\u003e\n\u003cli\u003eIntegrates sensors into auto alarm system.\u003c\/li\u003e\n\u003cli\u003eTransmits alarm to IP network via email and SNMP trap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIEEE 802.3bt Power over Ethernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompliance with IEEE 802.3bt Type-4 PoE++ standard\u003c\/li\u003e\n\u003cli\u003eBackward compatibility with IEEE 802.3at\/af PD device\u003c\/li\u003e\n\u003cli\u003ePowers up to four IEEE 802.3bt PoE++ devices (backward compatible with IEEE 802.3af\/at)\u003c\/li\u003e\n\u003cli\u003eSupports PoE with power up to 95 watts for each PoE port.\u003c\/li\u003e\n\u003cli\u003eTotal of 360-watt PoE budget\n\u003cul\u003e\n\u003cli\u003eA single power input can provide a power budget of up to 240W.\u003c\/li\u003e\n\u003cli\u003eTwo power inputs can provide a power budget of up to 360W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDetects Powered Devices (PD) automatically.\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports.\u003c\/li\u003e\n\u003cli\u003ePower feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\n\u003cul\u003e\n\u003cli\u003eTotal PoE power budget control\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE admin-mode control\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003ePoE extension mode to support power feeding up to a maximum distance of 160 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\n\u003cul\u003e\n\u003cli\u003eTemperature threshold setting\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold setting\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 IP Routing Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 dynamic routing protocol supports RIPv2 and OSPFv2. \u003c\/li\u003e\n\u003cli\u003eIPv6 dynamic routing protocol supports OSPFv3.\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 hardware static routing\u003c\/li\u003e\n\u003cli\u003eThe routing interface provides a per-VLAN routing mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Store-and-Forward architecture offers high performance, while the runt\/CRC filtering eliminates erroneous packets to optimize network bandwidth.\u003c\/li\u003e\n\u003cli\u003eStorm control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unknown unicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVLAN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport includes:\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eProvider bridging (VLAN Q-in-Q IEEE 802.1ad) \u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eSpanning Tree Protocol\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincluding:\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eLink Aggregation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincluding:\n\u003cul\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP: 6 ports\/3 groups max.)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk: 6 ports\/3 groups max.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (Many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco Uni-Directional Link Detection (UDLD), which monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices.\u003c\/li\u003e\n\u003cli\u003eSupports G.8032 ERPS (Ethernet Ring Protection Switching).\u003c\/li\u003e\n\u003cli\u003eSupports IEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress shaper and egress rate limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eToS\/DSCP\/IP Precedence of IPv4\/Ipv6 packets\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eSupports QoS and In\/Out bandwidth control on each port\u003c\/li\u003e\n\u003cli\u003eTraffic-policing on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking \u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP snooping v1, v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1 and v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIPv4 IGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eIPv6 MLD snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMVR (Multicast VLAN Registration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1x port-based\/MAC-based network access authentication\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1x authentication with guest VLAN\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to work with RADIUS servers\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ users access authentication\u003c\/li\u003e\n\u003cli\u003eGuest VLAN assigns clients to a restricted VLAN with limited services.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control List\n\u003cul\u003e\n\u003cli\u003eIP-based Access Control List (ACL)\u003c\/li\u003e\n\u003cli\u003eMAC-based Access Control List (ACL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSource MAC\/IP address binding\u003c\/li\u003e\n\u003cli\u003eDHCP Snooping filters distrusted DHCP messages.\u003c\/li\u003e\n\u003cli\u003eDynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding.\u003c\/li\u003e\n\u003cli\u003eIP Source Guard prevents IP spoofing attacks.\u003c\/li\u003e\n\u003cli\u003eIP address access management prevents unauthorized intruder.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interfaces\n\u003cul\u003e\n\u003cli\u003eConsole and Telnet Command Line Interface \u003c\/li\u003e\n\u003cli\u003eHTTP web switch management\u003c\/li\u003e\n\u003cli\u003eSNMP v1 and v2c switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2, TLSv1.2 and SNMPv3 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms, and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface Link Up and Link Down notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPv6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\u003c\/li\u003e\n\u003cli\u003eReset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003cli\u003eDual images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDHCP Functions:\n\u003cul\u003e\n\u003cli\u003eDHCP Relay\u003c\/li\u003e\n\u003cli\u003eDHCP Option82\u003c\/li\u003e\n\u003cli\u003eDHCP Server\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNetwork Time Protocol (NTP)\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnostic\n\u003cul\u003e\n\u003cli\u003eSFP-DDM (Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003cli\u003eICMPv6\/ICMPv4 remote ping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSMTP\/Syslog remote alarm\u003c\/li\u003e\n\u003cli\u003eSystem Log\u003c\/li\u003e\n\u003cli\u003ePLANET Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003ePLANET UNI-NMS (Universal Network Management) and CloudViewer app for deployment management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e4 2.5GBASE-T RJ45 auto negotiation port\u003cbr\u003eSupports 2.5G\/1G\/100\/10Mbps data rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP+ Ports\u003c\/td\u003e\n\u003ctd\u003e2 10GBASE-SR\/LR SFP+ slots\u003cbr\u003eBackward compatible with 1000BASE-SX\/LX\/BX and 2500BASE-X SFP transceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Injector Ports\u003c\/td\u003e\n\u003ctd\u003e4 ports with 802.3bt PoE++ injector function, from Port-1 to Port-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRemovable 6-pin terminal block for power input\u003cbr\u003ePin 1\/2 for Power 1, Pin 3\/4 for Alarm, Pin 5\/6 for Power 2\u003cbr\u003eRemovable 6-pin terminal block for DI\/DO interface\u003cbr\u003ePin 1\/2 for DI 1 \u0026amp; 2, Pin 3\/4 for DO 1 \u0026amp; 2, Pin 5\/6 for GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm relay current carry ability: 1A @ 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Input (DI)\u003c\/td\u003e\n\u003ctd\u003e2 digital inputs:\u003cbr\u003e　Level 0: -24~2.1V (±0.1V)\u003cbr\u003e　Level 1: 2.1~24V (±0.1V)\u003cbr\u003e　Input load to 24VDC, 10mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Output (DO)\u003c\/td\u003e\n\u003ctd\u003e2 digital outputs:\u003cbr\u003e　Open collector to 24VDC, 100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 aluminum case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or wall-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSDRAM\u003c\/td\u003e\n\u003ctd\u003e512Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e76 x 135 x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,319g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eDC 48V-54V, 8.3A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e48VDC Input:\u003c\/b\u003e\u003cbr\u003eMax. 8.9 watts\/30.4 BTU (Idle)\u003cbr\u003eMax. 379 watts\/1293.2 BTU (Full load)\u003cbr\u003e\u003cbr\u003e\u003cb\u003e54VDC Input:\u003c\/b\u003e\u003cbr\u003eMax. 9.2 watts\/31.4 BTU (Idle)\u003cbr\u003eMax. 381 watts\/1300 BTU (Full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003eContact 4KVDC; Air 8KVDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e2KVDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem:\u003c\/b\u003e\u003cbr\u003e　Power 1 (\u003cspan style=\"color: green;\"\u003eGreen\u003c\/span\u003e), Power 2 (\u003cspan style=\"color: green;\"\u003eGreen\u003c\/span\u003e)\u003cbr\u003e　Alarm (\u003cspan style=\"color: red;\"\u003eRed\u003c\/span\u003e)\u003cbr\u003e　Ring (\u003cspan style=\"color: green;\"\u003eGreen\u003c\/span\u003e), Ring Owner (\u003cspan style=\"color: green;\"\u003eGreen\u003c\/span\u003e)\u003cbr\u003e　DI\/DO (\u003cspan style=\"color: red;\"\u003eRed\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePoE Usage:\u003c\/b\u003e\u003cbr\u003e　120W\/240W\/360W (\u003cspan style=\"color: orange;\"\u003eAmber\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer 10\/100\/1G\/2.5GBASE-T RJ45 Port:\u003c\/b\u003e\u003cbr\u003e　Data LED:\u003cbr\u003e　　1G\/2.5G LNK\/ACT (\u003cspan style=\"color: green;\"\u003eGreen\u003c\/span\u003e)\u003cbr\u003e　　10\/100 LNK\/ACT (\u003cspan style=\"color: orange;\"\u003eAmber\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePoE LED:\u003c\/b\u003e\u003cbr\u003e　　IEEE 802.3bt Mode (\u003cspan style=\"color: green;\"\u003eGreen\u003c\/span\u003e)\u003cbr\u003e　　IEEE 802.3at Mode (\u003cspan style=\"color: orange;\"\u003eAmber\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer 1G\/2.5G\/10GBASE-X SFP+ Port:\u003c\/b\u003e\u003cbr\u003e　1G\/2.5Gbps LNK\/ACT (\u003cspan style=\"color: green;\"\u003eGreen\u003c\/span\u003e)\u003cbr\u003e　10Gbps LNK\/ACT (\u003cspan style=\"color: orange;\"\u003eAmber\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e60Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e44.462Mpps@64Bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e8K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e32Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower over Ethernet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3bt PoE++ Type-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Supply Type\u003c\/td\u003e\n\u003ctd\u003eEnd-span\u003cbr\u003eMid-span\u003cbr\u003eBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Pin Assignment\u003c\/td\u003e\n\u003ctd\u003e802.3bt\/UPoE: 1\/2(-), 3\/6(+), 4\/5(+), 7\/8(-)\u003cbr\u003e802.3at\/PoE: End-span: 1\/2(-), 3\/6(+)\u003cbr\u003e802.3at\/PoE: Mid-span: 4\/5(+), 7\/8(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Output\u003c\/td\u003e\n\u003ctd\u003ePer port 48V ~ 54VDC\u003cbr\u003e-802.3bt Type-4 mode: maximum 95 watts\u003cbr\u003e-End-span mode: maximum 36 watts\u003cbr\u003e-Mid-span mode: maximum 36 watts\u003cbr\u003e-Force mode: maximum 95 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003eSingle power input: 240W maximum (depending on power input)\u003cbr\u003eDual power input: 360W maximum (depending on power input)\u003cbr\u003e※Dual power input must be the same as DC voltage, like dual 54V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNumber of 90W 802.3bt Type-4 PDs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNumber of 60W 802.3bt Type-3 PDs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNumber of 30W 802.3at Type-2 PDs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePoE Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnhanced PoE Mode\u003c\/td\u003e\n\u003ctd\u003eStandard\/Legacy\/Force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Management\u003c\/td\u003e\n\u003ctd\u003ePD Alive Check\u003cbr\u003eScheduled Power Recycling\u003cbr\u003ePoE Schedule\u003cbr\u003ePoE Usage Monitoring\u003cbr\u003ePoE Extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eActive PoE Device Live Detection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Recycling\u003c\/td\u003e\n\u003ctd\u003eYes, daily or predefined schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Schedule\u003c\/td\u003e\n\u003ctd\u003e4 schedule profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Extend Mode\u003c\/td\u003e\n\u003ctd\u003eYes, max. up to 160 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 32 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 32 static routing entries\u003cbr\u003eMax. 1K routing table entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 RIPv2\u003cbr\u003eIPv4 OSPFv2\u003cbr\u003eIPv6 OSPFv3\u003cbr\u003eIPv4 hardware static routing\u003cbr\u003eIPv6 hardware static routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000\/2500Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay of each port’s speed duplex mode, link status, flow control status, auto-negotiation status and trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/Both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eRMirror – Remote Switched Port Analyzer (Cisco RSPAN)\u003cbr\u003eSupports up to 5 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q tagged VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eIP Subnet-based VLAN\u003cbr\u003eMVR (Multicast VLAN registration)\u003cbr\u003eGVRP\u003cbr\u003eUp to 4K VLAN groups, out of 4095 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003eMax. 3 trunk groups with max. 6 ports per trunk group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eSupports 7 MSTP instances\u003cbr\u003eBPDU Guard, BPDU filtering and BPDU transparent\u003cbr\u003eRoot Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP (v1\/v2\/v3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eSupports 255 IGMP groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD (v1\/v2) snooping,\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eSupports 255 MLD groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003e　Ingress: 10Kbps~13128Mbps\u003cbr\u003e　Egress: 10Kbps~13128Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 10ms @ 3 nodes\u003cbr\u003eRecovery time \u0026lt; 50ms @ 16 nodes\u003cbr\u003eSupports Major ring and sub-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP (Precision Time Protocol)\u003cbr\u003e　Peer-to-peer transparent clock\u003cbr\u003e　End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching:\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP\/ToS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003e　MAC Address\u003cbr\u003e　IP Address\u003cbr\u003e　Ethertype\u003cbr\u003e　Protocol Type\u003cbr\u003e　VLAN ID\u003cbr\u003e　DSCP\u003cbr\u003e　802.1p Priority\u003cbr\u003eUp to 512 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003ePort security\u003cbr\u003eIP source guard, up to 512 entries\u003cbr\u003eDynamic ARP inspection, up to 1K entries\u003cbr\u003eCommand line authority control based on user level\u003cbr\u003eStatic MAC address, up to 64 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLS v1.2, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET CloudViewer app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Group 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eRFC 4292 IP Forward MIB\u003cbr\u003eRFC 4293 IP MIB\u003cbr\u003eRFC 4836 MAU-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A\u003cbr\u003eCE:\u003cbr\u003e　EN55032\u003cbr\u003e　EN55035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC60068-2-32 (free fall)\u003cbr\u003eIEC60068-2-27 (shock)\u003cbr\u003eIEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3ae 10GBASE-X\u003cbr\u003eIEEE 802.3bz 2.5\/5GBASE-T\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 802.1ag Connectivity Fault Management (CFM)\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 783 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD v1\u003cbr\u003eRFC 3810 MLD v2\u003cbr\u003eRFC 2328 OSPF v2\u003cbr\u003eRFC 5340 OSPF v3\u003cbr\u003eRFC 2453 RIP v2\u003cbr\u003eITU-T G.8032 ERPS Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 75 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892939403520,"sku":"IGS-6325-4UP2X","price":1081.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-6325-4UP2X.jpg?v=1782490835","url":"https:\/\/alotechparts.com\/en-mx\/products\/planet-igs-6325-4up2x-ip30-din-rail-industrial-l3-4-port-25gbase-t-8023bt-poe","provider":"Alo Tech Solutions","version":"1.0","type":"link"}