{"product_id":"planet-igs-6325-16t4s-ip30-industrial-l3-16-port-101001000t-4-port-1g25g-sfp","title":"Planet IGS-6325-16T4S IP30 Industrial L3 16-Port 10\/100\/1000T + 4-port 1G\/2.5G SFP","description":"\u003cp\u003e\u003cstrong\u003eHigh-capacity Unit for Factory and Metropolitan Long-reach Networking\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET IGS-6325-16T4S is the smallest yet high-capacity, industrial-grade Layer 3 managed switch with high-density hybrid copper and fiber optic interfaces. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 10\/100\/1000BASE-T RJ45 ports and \u003c\/strong\u003e\u003cstrong\u003e4 100\/1000\/ 2500BASE-X SFP slots\u003c\/strong\u003e in a DIN-rail type rugged case and can operate stably under the temperature range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40 to 75 degrees C\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp\u003eIt is designed to be installed in any space-limited cabinets as it is small in size. Its connection distance can be flexibly extended via its powerful ports. \u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"400\" width=\"1000\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/edm_IGS-6325-16T4S.jpg\"\u003e\u003cstrong\u003e\u003cimg class=\"img-fluid\" height=\"313\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/IGS-6325-16T4S-51.png\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 Routing Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S enables the administrator to conveniently boost network efficiency by configuring Layer 3 IPv4\/IPv6 VLAN static routing manually, and the IPv4\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOSPFv2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Open Shortest Path First) settings automatically. The OSPF is an interior dynamic routing protocol for autonomous system based on link state. The protocol creates a database for link state by exchanging link states among Layer 3 switches, and then uses the Shortest Path First algorithm to generate a route table based on that database.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eITU-T G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology, Spanning Tree Protocol (802.1s MSTP), and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a simple Ring network, the recovery time of data link can be as fast as 10ms.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"537\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/IGS-6325-16T4S-3.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork with Cybersecurity Helps Minimize Security Risks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports SSHv2 and TLS v1.2 protocols to provide strong protection against advanced threats. Served as a key point to transmit data over multiple long distance fiber optical connections to customer's critical equipment in a business network, the cybersecurity feature of the IGS-6325-16T4S protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"137\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/Common_Secure-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the supported\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol, the IGS-6325-16T4S can easily integrate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCADA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoperating information\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eport information\u003c\/strong\u003e, communication status, and DI and DO status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S is ideal for telecom and carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"473\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/IGS-6325-16T4S-1.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power to Ensure Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S possesses dual\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC 9~48V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC 24V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply utilized as redundant power supply to ensure its continuous operation. Its redundant power system is specifically designed to handle the demands of high-tech facilities requiring the highest power integrity. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSMTP\/SNMP Trap Event Alert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEffective Alarm Alert for Better Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time to find where the problem is. It will help to save time and human resource.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"361\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/IGS-6325-16T4S-2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Input and Digital Output for External Alarm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-6325-16T4S port shows link down, link up or power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"646\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/IGS-6325-16T4S-6.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIPv6\/IPv4 Dual Stack\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupporting both IPv6 and IPv4 protocols, the IGS-6325-16T4S helps data centers, campuses, telecoms, and more to experience the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S can be programmed for advanced Layer 2 switch management functions such as dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping and MLD snooping. Via the aggregation of supporting ports, the IGS-6325-16T4S allows the operation of a high-speed trunk group that comes with multiple ports and supports fail-over as well.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"217\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/Common_Robust-Layer-2-Features.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor efficient management, the IGS-6325-16T4S is equipped with console, Web and SNMP management interfaces. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWeb-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement interface, the IGS-6325-16T4S offers an easy-to-use, platform-independent management and configuration facility. \u003c\/li\u003e\n\u003cli\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etext-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement, it can be accessed via Telnet and the console port. \u003c\/li\u003e\n\u003cli\u003eFor standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePowerful Network Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S offers comprehensive Layer 2 to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLayer 4 Access Control List (ACL)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e802.1X Port-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMAC-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser and device authentication. With the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprivate VLAN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction, communication between edge ports can be prevented to ensure user privacy. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced IP Network Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S also provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExcellent Traffic Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S is loaded with powerful traffic management and QoS features to enhance connection services by telecoms and ISPs. The QoS features include wire-speed Layer 4 traffic classifiers and bandwidth limit that are particularly useful for multi-tenant units, multi-business units, Telco and network service providers’ applications. It also empowers the industrial environment to take full advantage of the limited network resources and guarantees the best performance in VoIP and video conferencing transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4S supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"350\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49343\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePhysical Port\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003e16 10\/100\/1000BASE-T RJ45 copper ports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4 100\/1000\/2500BASE-X mini-GBIC\/SFP slots for SFP type auto detection \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOne RJ45-to-RS232 console interface for basic management and setup\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial Hardened Design\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eDual power input, redundant power with reverse polarity protection\u003c\/li\u003e\n- DC 9 to 48V input or AC 24V input\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Active-active redundant power failure protection\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Backup of catastrophic power failure on one supply\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Fault tolerance and resilience\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003eDIN-rail and wall-mountable designs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP30 aluminum case \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports 6KV DC Ethernet ESD protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e-40 to 75 degrees C operating temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDigital Input and Digital Output\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003e2 Digital Input (DI)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 Digital Output (DO)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrates sensors into auto alarm system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTransfers alarm to IP network via email and SNMP trap\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eLayer 3 IP Routing Features\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003eIPv4 dynamic routing protocol supports OSPFv2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIPv4\/IPv6 hardware static routing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRouting interface provides per VLAN routing mode\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eLayer 2 Features\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStorm control support\u003c\/span\u003e\u003c\/li\u003e\n- Broadcast\/Multicast\/Unknown unicast\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSupports \u003cspan\u003eVLAN\u003c\/span\u003e\n\u003c\/li\u003e\n- IEEE 802.1Q tagged VLAN\u003c\/ul\u003e\n\u003cul\u003e- Up to 4K VLANs groups, out of 4095 VLAN IDs\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Supports provider bridging (VLAN Q-in-Q IEEE 802.1ad)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Private VLAN Edge (PVE)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Protocol-based VLAN\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- MAC-based VLAN\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Voice VLAN\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- GVRP (GARP VLAN Registration Protocol)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eSupports \u003cspan\u003eSpanning Tree Protocol\u003c\/span\u003e\n\u003c\/li\u003e\n- IEEE 802.1D Spanning Tree Protocol (STP)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- IEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- BPDU Guard\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eSupports \u003cspan\u003eLink Aggregation\u003c\/span\u003e\n\u003c\/li\u003e\n- 802.3ad Link Aggregation Control Protocol (LACP)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Cisco ether-channel (static trunk)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Maximum 14 trunk groups, with 16 ports for each trunk\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Up to 80Gbps bandwidth (full duplex mode)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003eProvides port mirror (many-to-1)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoop protection to avoid broadcast loops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLink Layer Discovery Protocol (LLDP)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with Cisco uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIEEE 1588 and Synchronous Ethernet network timing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eQuality of Service\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eIngress shaper and egress rate limit per port bandwidth control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e8 priority queues on all switch ports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTraffic classification\u003c\/span\u003e\u003c\/li\u003e\n- IEEE 802.1p CoS\u003c\/ul\u003e\n\u003cul\u003e- ToS\/DSCP\/IP Precedence of IPv4\/IPv6 packets\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- IP TCP\/UDP port number\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Typical network application\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTraffic-policing  on the switch port\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDSCP remarking \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoice VLAN\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eMulticast\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003eSupports IPv4 IGMP snooping v1, v2 and v3\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports IPv6 MLD snooping v1 and v2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuerier mode support\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIPv4 IGMP snooping port filtering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIPv6 MLD snooping port filtering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMVR (Multicast VLAN Registration)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eSecurity\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eAuthentication\u003c\/li\u003e\n- IEEE 802.1X Port-based\/MAC-based network access authentication\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- IEEE 802.1x authentication with guest VLAN\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Built-in RADIUS client to cooperate with the RADIUS servers\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- RADIUS\/TACACS+ users access authentication\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Guest VLAN assigns clients to a restricted VLAN with limited services\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eAccess Control List\u003c\/li\u003e\n- IP-based Access Control List (ACL)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- MAC-based Access Control List (ACL)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003eSource MAC\/IP address binding\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDHCP Snooping to filter distrusted DHCP messages\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP Source Guard prevents IP spoofing attacks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP address access management to prevent unauthorized intruder\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eManagement\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eIPv4 and IPv6 dual stack management\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSwitch Management Interfaces\u003c\/span\u003e\u003c\/li\u003e\n- Console and Telnet Command Line Interface \u003c\/ul\u003e\n\u003cul\u003e- HTTP web switch management\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- SNMP v1 and v2c switch management\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- SSHv2,TLSv1.2 and SNMP v3 secure access\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eSNMP Management\u003c\/li\u003e\n- Four RMON groups (history, statistics, alarms, and events)\u003c\/ul\u003e\n\u003cul\u003e- SNMP trap for interface Link Up and Link Down notification\n\u003cli\u003e\u003cspan\u003eIPv6 IP address\/NTP\/DNS management\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBOOTP and DHCP for IP address assignment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSystem Maintenance\u003c\/span\u003e\u003c\/li\u003e\n- Firmware upload\/download via HTTP\u003c\/ul\u003e\n\u003cul\u003e- Reset button for system reboot or reset to factory default\u003c\/ul\u003e\n\u003cul\u003e- Dual Images\n\u003cli\u003e\u003cspan\u003eDHCP Relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDHCP Option 82\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDHCP Server\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser Privilege levels control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNetwork Time Protocol (NTP)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNetwork Diagnostic\u003c\/span\u003e\u003c\/li\u003e\n- SFP-DDM (Digital Diagnostic Monitor)\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- Cable diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e- ICMPv6\/ICMPv4 remote ping\u003c\/ul\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e\u003cspan\u003eSMTP\/Syslog remote alarm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSystem Log\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePLANET Smart Discovery Utility for deployment management\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e16 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP Ports\u003c\/td\u003e\n\u003ctd\u003e4 100\/1000\/2500BASE-X SFP slot interfaces (Port-17 to Port-20)\u003cbr\u003eCompatible with 100BASE-FX SFP transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP+ Ports\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e40Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e29.76Mpps@64Bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e32K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e32Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSDRAM\u003c\/td\u003e\n\u003ctd\u003e512Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRemovable 6-pin terminal block for power input\u003cbr\u003ePin 1\/2 for Power 1, Pin 3\/4 for fault alarm, Pin 5\/6 for Power 2\u003cbr\u003eRemovable 6-pin terminal block for DI\/DO interface\u003cbr\u003ePin 1\/2 for DI 1 \u0026amp; 2, Pin 3\/4 for DO 1 \u0026amp; 2, Pin 5\/6 for GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Input (DI)\u003c\/td\u003e\n\u003ctd\u003e2 digital input:\u003cbr\u003e　Level 0: -24~2.1V (±0.1V)\u003cbr\u003e　Level 1: 2.1~24V (±0.1V)\u003cbr\u003e　Input load to 24V DC, 10mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Output (DO)\u003c\/td\u003e\n\u003ctd\u003e2 digital output:\u003cbr\u003e　Open collector to 24VDC, 100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 aluminum case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e80 x 107 x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,168g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eDC 9~48V, 3.3A max.\u003cbr\u003eAC 24V, 1.2A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDC input:\u003cbr\u003eMax. 9.12 watts\/32BTU\u003cbr\u003e(system on)\u003cbr\u003eMax. 26.04 watts\/89 BTU (Full loading)\u003cbr\u003e\u003cbr\u003eAC 24V input:\u003cbr\u003eMax. 12 watts\/41BTU (system on)\u003cbr\u003eMax. 29 watts\/99 BTU (Full loading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e4KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eSystem:\u003cbr\u003e　Power 1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e), Power 2 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Fault Alarm (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e), Ring Owner (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　DIDO (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003ePer 10\/100\/1000T RJ45 Port:\u003cbr\u003e　1000Mbps LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　10\/100Mbps LNK\/ACT (\u003cspan style=\"color: ffbf00;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003ePer SFP Port:\u003cbr\u003e　1G\/2.5G LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　100Mbps LNK\/ACT (\u003cspan style=\"color: ffbf00;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e52Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e38.69Mpps@64Bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e16K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e32Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 128 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 128 static routing entries\u003cbr\u003eMax. 4000 dynamic routing entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 hardware static routing\u003cbr\u003eIPv6 hardware static routing\u003cbr\u003eOSPFv2 dynamic routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay each port’s speed duplex mode, link status, flow control status, auto-negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/Both\u003cbr\u003eMany-to-1 monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003e802.1Q tagged VLAN\u003cbr\u003eQ-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eIP Subnet-based VLAN\u003cbr\u003eMVR (Multicast VLAN registration)\u003cbr\u003eGVRP\u003cbr\u003eUp to 4K VLAN groups, out of 4095 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003e14 trunk groups with 16 port per trunk group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP (v1\/v2\/v3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eSupports 255 IGMP groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD (v1\/v2) snooping,\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eSupports 255 MLD groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003e　- MAC Address\u003cbr\u003e　- IP Address\u003cbr\u003e　- Ethertype\u003cbr\u003e　- Protocol Type\u003cbr\u003e　- VLAN ID\u003cbr\u003e　- DSCP\u003cbr\u003e　- 802.1p Priority\u003cbr\u003eUp to 512 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003eIngress: 100Kbps~1000Mbps\u003cbr\u003eEgress: 100Kbps~1000Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching:\u003cbr\u003e　- Port number\u003cbr\u003e　- 802.1p priority\u003cbr\u003e　- 802.1Q VLAN tag\u003cbr\u003e　- DSCP\/ToS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eSupports Major ring and sub-ring\u003cbr\u003eRecovery time \u0026lt; 10ms @ 3 units\u003cbr\u003eRecovery time \u0026lt; 50ms @ 16 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP(Precision Time Protocol)\u003cbr\u003e　- Peer-to-peer transparent clock\u003cbr\u003e　- End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLS v1.2, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Group 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eRFC 4292 IP Forward MIB\u003cbr\u003eRFC 4293 IP MIB\u003cbr\u003eRFC 4836 MAU-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A\u003cbr\u003eCE:\u003cbr\u003eEN55032\u003cbr\u003eEN55035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC60068-2-32 (free fall)\u003cbr\u003eIEC60068-2-27 (shock)\u003cbr\u003eIEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 802.1ag Connectivity Fault Management (CFM)\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 793 TCP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD v1\u003cbr\u003eRFC 3810 MLD v2\u003cbr\u003eRFC 2328 OSPF v2\u003cbr\u003eITU-T G.8032 ERPS Ring\u003cbr\u003eITU-T Y.1731 Performance Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 75 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892939862272,"sku":"IGS-6325-16T4S","price":1312.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-6325-16T4Sv1.2.jpg?v=1782490837","url":"https:\/\/alotechparts.com\/en-br\/products\/planet-igs-6325-16t4s-ip30-industrial-l3-16-port-101001000t-4-port-1g25g-sfp","provider":"Alo Tech Solutions","version":"1.0","type":"link"}