{"product_id":"nscomm-mpo-12f-upc-to-4xlc-upc-duplex-harness-cables-8-fibers-multimode-om4-ofnr-crossover","title":"NSComm MPO 12F UPC to 4xLC UPC Duplex Harness Cables, 8 Fibers, Multimode (OM4), OFNR, Crossover","description":"\u003ch3 data-end=\"112\" data-start=\"98\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-end=\"539\" data-start=\"114\"\u003eThe NSComm MPO 12F UPC to 4xLC UPC Duplex harness cable is a high-density OM4 multimode breakout solution designed for migration between duplex and parallel optics in modern data centers. With one 12-fiber MPO UPC (Female) trunk breaking out to four LC UPC duplex connectors, this harness provides 8 active fibers to serve switch, server, or patch panel LC ports while leveraging a compact MPO backbone for cable consolidation.\u003c\/p\u003e\n\u003cp data-end=\"1147\" data-start=\"541\"\u003eFactory-terminated and fully tested, the MPO-LC harness delivers verified low insertion loss and stable return loss for improved network integrity in 10G\/25G and 40G\/100G Ethernet environments. Built with bend-insensitive OM4 50\/125 μm multimode fiber and a riser-rated OFNR jacket, it is ideal for high-density cabling in data centers, equipment rooms, and telecommunication rooms where space savings, airflow, and clean cable management are critical. The crossover polarity design simplifies connectivity between MPO backbones and LC front-panel ports in duplex and parallel optics migration scenarios.\u003c\/p\u003e\n\u003cp data-end=\"1337\" data-start=\"1149\"\u003eNeed help validating polarity, LC mapping, or compatibility with your patch panels and multimode transceivers? Contact us now and our team will help review your design before deployment.\u003c\/p\u003e\n\u003ch4 data-end=\"1368\" data-start=\"1344\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cdiv class=\"_tableContainer_80l1q_1\"\u003e\n\u003cdiv class=\"_tableWrapper_80l1q_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"4964\" data-start=\"1370\"\u003e\n\u003cthead data-end=\"1494\" data-start=\"1370\"\u003e\n\u003ctr data-end=\"1494\" data-start=\"1370\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1405\" data-start=\"1370\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1494\" data-start=\"1405\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"4964\" data-start=\"1619\"\u003e\n\u003ctr data-end=\"1742\" data-start=\"1619\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1653\" data-start=\"1619\"\u003eVendor Name\u003c\/td\u003e\n\u003ctd data-end=\"1742\" data-start=\"1653\" data-col-size=\"md\"\u003eNSComm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1866\" data-start=\"1743\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1777\" data-start=\"1743\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-end=\"1866\" data-start=\"1777\" data-col-size=\"md\"\u003eMPO 12F UPC to 4xLC UPC Duplex Multimode Harness Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1990\" data-start=\"1867\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1901\" data-start=\"1867\"\u003eConnector A\u003c\/td\u003e\n\u003ctd data-end=\"1990\" data-start=\"1901\" data-col-size=\"md\"\u003eMPO-12 UPC Female (Pinless), Low Loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2114\" data-start=\"1991\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2025\" data-start=\"1991\"\u003eConnector B\u003c\/td\u003e\n\u003ctd data-end=\"2114\" data-start=\"2025\" data-col-size=\"md\"\u003e4 × LC UPC Duplex connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2238\" data-start=\"2115\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2149\" data-start=\"2115\"\u003ePolish Type\u003c\/td\u003e\n\u003ctd data-end=\"2238\" data-start=\"2149\" data-col-size=\"md\"\u003eUPC to UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2362\" data-start=\"2239\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2273\" data-start=\"2239\"\u003eFiber Mode\u003c\/td\u003e\n\u003ctd data-end=\"2362\" data-start=\"2273\" data-col-size=\"md\"\u003eOM4 50\/125 μm Multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2485\" data-start=\"2363\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2397\" data-start=\"2363\"\u003eGlass Fiber\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2485\" data-start=\"2397\"\u003eBend-insensitive multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2609\" data-start=\"2486\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2520\" data-start=\"2486\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-end=\"2609\" data-start=\"2520\" data-col-size=\"md\"\u003e850 nm \/ 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2733\" data-start=\"2610\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2644\" data-start=\"2610\"\u003eFiber Count\u003c\/td\u003e\n\u003ctd data-end=\"2733\" data-start=\"2644\" data-col-size=\"md\"\u003e8 Active Fibers (4×LC duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2857\" data-start=\"2734\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2768\" data-start=\"2734\"\u003ePolarity\u003c\/td\u003e\n\u003ctd data-end=\"2857\" data-start=\"2768\" data-col-size=\"md\"\u003eCrossover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2981\" data-start=\"2858\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2892\" data-start=\"2858\"\u003eCable Outside Diameter (OD)\u003c\/td\u003e\n\u003ctd data-end=\"2981\" data-start=\"2892\" data-col-size=\"md\"\u003e3.0 mm (trunk, typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3105\" data-start=\"2982\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3016\" data-start=\"2982\"\u003eBreakout Outside Diameter (OD)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3105\" data-start=\"3016\"\u003e2.0 mm (LC legs, typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3229\" data-start=\"3106\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3140\" data-start=\"3106\"\u003eBreakout Length\u003c\/td\u003e\n\u003ctd data-end=\"3229\" data-start=\"3140\" data-col-size=\"md\"\u003e0.5 m (typical leg length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3353\" data-start=\"3230\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3264\" data-start=\"3230\"\u003eCable Jacket\u003c\/td\u003e\n\u003ctd data-end=\"3353\" data-start=\"3264\" data-col-size=\"md\"\u003eRiser-rated, OFNR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3477\" data-start=\"3354\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3388\" data-start=\"3354\"\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd data-end=\"3477\" data-start=\"3388\" data-col-size=\"md\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3601\" data-start=\"3478\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3512\" data-start=\"3478\"\u003eMPO Connector Insertion Loss\u003c\/td\u003e\n\u003ctd data-end=\"3601\" data-start=\"3512\" data-col-size=\"md\"\u003e≤ 0.35 dB (Typ. 0.15 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3725\" data-start=\"3602\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3636\" data-start=\"3602\"\u003eMPO Connector Return Loss\u003c\/td\u003e\n\u003ctd data-end=\"3725\" data-start=\"3636\" data-col-size=\"md\"\u003e≥ 20 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3849\" data-start=\"3726\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3760\" data-start=\"3726\"\u003eLC Connector Insertion Loss\u003c\/td\u003e\n\u003ctd data-end=\"3849\" data-start=\"3760\" data-col-size=\"md\"\u003e≤ 0.20 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3973\" data-start=\"3850\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3884\" data-start=\"3850\"\u003eLC Connector Return Loss\u003c\/td\u003e\n\u003ctd data-end=\"3973\" data-start=\"3884\" data-col-size=\"md\"\u003e≥ 30 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4097\" data-start=\"3974\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4008\" data-start=\"3974\"\u003eAttenuation @ 850 nm\u003c\/td\u003e\n\u003ctd data-end=\"4097\" data-start=\"4008\" data-col-size=\"md\"\u003e≤ 2.3 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4221\" data-start=\"4098\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4132\" data-start=\"4098\"\u003eAttenuation @ 1300 nm\u003c\/td\u003e\n\u003ctd data-end=\"4221\" data-start=\"4132\" data-col-size=\"md\"\u003e≤ 0.6 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4345\" data-start=\"4222\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4256\" data-start=\"4222\"\u003eLong-term Tensile Load\u003c\/td\u003e\n\u003ctd data-end=\"4345\" data-start=\"4256\" data-col-size=\"md\"\u003e80 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4469\" data-start=\"4346\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4380\" data-start=\"4346\"\u003eShort-term Tensile Load\u003c\/td\u003e\n\u003ctd data-end=\"4469\" data-start=\"4380\" data-col-size=\"md\"\u003e240 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4593\" data-start=\"4470\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4504\" data-start=\"4470\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-end=\"4593\" data-start=\"4504\" data-col-size=\"md\"\u003e-10 to 60 °C (14 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4717\" data-start=\"4594\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4628\" data-start=\"4594\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-end=\"4717\" data-start=\"4628\" data-col-size=\"md\"\u003e-10 to 70 °C (14 to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4841\" data-start=\"4718\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4752\" data-start=\"4718\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd data-end=\"4841\" data-start=\"4752\" data-col-size=\"md\"\u003eMPO interface standards, OM4\/MMF, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4964\" data-start=\"4842\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4876\" data-start=\"4842\"\u003eApplications\u003c\/td\u003e\n\u003ctd data-end=\"4964\" data-start=\"4876\" data-col-size=\"md\"\u003eDuplex–parallel migration, 10G\/25G to 40G\/100G, high-density LC breakout in racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch4 data-end=\"5041\" data-start=\"4971\"\u003eWhy Choose NSComm MPO 12F UPC to 4xLC UPC Duplex OM4 Harness Cables?\u003c\/h4\u003e\n\u003cul data-end=\"5824\" data-start=\"5043\"\u003e\n\u003cli data-end=\"5182\" data-start=\"5043\"\u003e\n\u003cp data-end=\"5182\" data-start=\"5045\"\u003e\u003cstrong data-end=\"5080\" data-start=\"5045\"\u003eDuplex–parallel migration ready\u003c\/strong\u003e – Bridges MPO-based backbones with LC-based switch and server ports for 10\/25G to 40\/100G upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5307\" data-start=\"5183\"\u003e\n\u003cp data-end=\"5307\" data-start=\"5185\"\u003e\u003cstrong data-end=\"5217\" data-start=\"5185\"\u003eHigh-density breakout design\u003c\/strong\u003e – One MPO trunk to four LC duplex legs reduces front-of-rack congestion and cable bulk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5442\" data-start=\"5308\"\u003e\n\u003cp data-end=\"5442\" data-start=\"5310\"\u003e\u003cstrong data-end=\"5351\" data-start=\"5310\"\u003eLow-loss, factory-terminated solution\u003c\/strong\u003e – MPO and LC connectors are pre-terminated and tested to maintain tight optical budgets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5562\" data-start=\"5443\"\u003e\n\u003cp data-end=\"5562\" data-start=\"5445\"\u003e\u003cstrong data-end=\"5485\" data-start=\"5445\"\u003eOM4 bend-insensitive multimode fiber\u003c\/strong\u003e – Supports higher bandwidth and stable performance in tight routing paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5688\" data-start=\"5563\"\u003e\n\u003cp data-end=\"5688\" data-start=\"5565\"\u003e\u003cstrong data-end=\"5613\" data-start=\"5565\"\u003eCrossover polarity for clean channel mapping\u003c\/strong\u003e – Pre-engineered polarity simplifies design and reduces patching errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5824\" data-start=\"5689\"\u003e\n\u003cp data-end=\"5824\" data-start=\"5691\"\u003e\u003cstrong data-end=\"5724\" data-start=\"5691\"\u003eRiser-rated OFNR construction\u003c\/strong\u003e – Suitable for structured cabling, in-cabinet routing, and high-density data center environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"5851\" data-start=\"5831\"\u003eLength Options\u003c\/h4\u003e\n\u003cp data-end=\"6081\" data-start=\"5853\"\u003e\u003cstrong data-end=\"5882\" data-start=\"5853\"\u003eStandard stocked lengths:\u003c\/strong\u003e\u003cbr data-end=\"5885\" data-start=\"5882\"\u003eAvailable in common harness lengths optimized for top-of-rack, middle-of-row, and end-of-row deployments, with balanced trunk and breakout leg lengths for typical switch and patch panel layouts.\u003c\/p\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"6264\" data-start=\"6083\"\u003e\u003cstrong data-end=\"6102\" data-start=\"6083\"\u003eCustom lengths:\u003c\/strong\u003e\u003cbr data-end=\"6105\" data-start=\"6102\"\u003eCustom trunk lengths, breakout leg lengths, labeling, and connector configurations are available on request to match your exact rack layout and cabling design.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003eMore Details\u003c\/h3\u003e\n\u003ch4 class=\"authoritative-certification-icon\" style=\"text-align: left;\"\u003eQuality Certifications\u003cb\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/3Y_Warranty_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO9001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO14001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO27001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO45001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/CE-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/Reach-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/CB-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/cURus-UL_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/FCC-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/UKCA-SFP_50x50.png?v=1753521101\" style=\"margin-bottom: 16px; float: none;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003eDo you have any question about the NSComm MPO 12F to 4xLC UPC MM OM4 Harness Cable?\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003ePlease \u003ca href=\"#chatty-chat\"\u003eChat with us\u003c\/a\u003e now!\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003eor leave us an message on \u003ca href=\"mailto:sales@network-switch.com\"\u003esales@network-switch.com\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 class=\"pb-4 mb-4\"\u003eWarranty\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i1\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Low Price Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNetwork-switch.com provides high-quality products at low wholesale prices\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6\"\u003e\n\u003ci class=\"i2\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Quality Assurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll items are ORIGINAL and GENUINE only.\u003cbr\u003eItem conditions are \"New Sealed\". They are fully tested by Certified CCIE \/ HCIE \/ RCNP Engineers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i4\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eFree Technical Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOur FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6\"\u003e\n\u003ci class=\"i3\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Money Back Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can contact our customer service team to exchange or return any product that you bought from us.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"detaildl_3 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eStandard Warranty Policy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOriginal New Sealed Enterprise Hardware: 3 Years\u003cbr\u003eOriginal New Sealed Consumer Devices: 1 Year\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_3 col-12 col-md-6\"\u003e\n\u003ci class=\"i\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eThe Support Contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Network-Switch \u0026 NS","offers":[{"title":"1m (3ft)","offer_id":48886066315520,"sku":"NS-MPO12H8F-4LCOM4-1","price":690.12,"currency_code":"USD","in_stock":true},{"title":"2m (7ft)","offer_id":48886066348288,"sku":"NS-MPO12H8F-4LCOM4-2","price":783.84,"currency_code":"USD","in_stock":true},{"title":"3m (10ft)","offer_id":48886066381056,"sku":"NS-MPO12H8F-4LCOM4-3","price":947.14,"currency_code":"USD","in_stock":true},{"title":"5m (16ft)","offer_id":48886066413824,"sku":"NS-MPO12H8F-4LCOM4-4","price":1157.3,"currency_code":"USD","in_stock":true},{"title":"10m (33ft)","offer_id":48886066446592,"sku":"NS-MPO12H8F-4LCOM4-5","price":1590.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/MPO-12F-LC-8F.jpg?v=1782318784","url":"https:\/\/alotechparts.com\/en-br\/products\/nscomm-mpo-12f-upc-to-4xlc-upc-duplex-harness-cables-8-fibers-multimode-om4-ofnr-crossover","provider":"Alo Tech Solutions","version":"1.0","type":"link"}