{"title":"Siemens Fire Alarm Panels \u0026 Parts","description":"\u003cp\u003e\u003cstrong\u003eSiemens fire alarm panels and parts\u003c\/strong\u003e — about 55 products: Cerberus PRO FC922 and FC901 panels, periphery boards and zone amplifier cards, MXL and MXL-IQ line cards, loop drivers, network and communication interface modules, XLS device loop cards and assemblies, legacy System 3, SXL-X and FS-250 boards and annunciators, FirePrint and intelligent smoke detectors, beam and flame detectors, intelligent pull stations, PAD notification power extenders and fiber-optic network modules.\u003c\/p\u003e\u003cp\u003eLegacy Siemens and Cerberus Pyrotronics boards are quoted against your panel's part number, and Cerberus PRO panels and PAD extenders are available for upgrades.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstallation note:\u003c\/strong\u003e fire alarm, suppression and gas detection equipment must be installed, programmed and tested by qualified technicians under NFPA 72 or your local fire code, and replacement devices must be listed as compatible with the control panel they connect to.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat to include in your RFQ:\u003c\/strong\u003e the Siemens part number (for example MLC, FCI2017-U1 or PAD-4-9A), the panel model, quantity and delivery country.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFree worldwide DDP shipping\u003c\/strong\u003e — all duties, taxes and customs clearance included in the quoted price. Quotes returned within 24 hours; company purchase orders accepted.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/request-for-quote\" style=\"display:inline-block;margin:10px 0;padding:13px 28px;background:#c8102e;color:#ffffff;font-weight:700;text-decoration:none;border-radius:6px;\"\u003eRequest a Quote — Bulk Pricing →\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDo you have parts for MXL and XLS panels?\u003c\/strong\u003e\u003cbr\u003eYes — MXL line cards, analog loop drivers, XNET network interface modules, MXL power supply modules and XLS device loop cards are listed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich detectors work with Siemens panels?\u003c\/strong\u003e\u003cbr\u003eFirePrint, intelligent ionization and photoelectric detectors are listed for MXL, XLS and FS-250 systems; send your panel model and we confirm the right device.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan you supply Siemens voice evacuation cards?\u003c\/strong\u003e\u003cbr\u003eYes — zone amplifier cards, card amplifiers, digital audio cards and voice evacuation amplifiers are listed.\u003c\/p\u003e\u003cp class=\"seo-links\"\u003eBrowse: \u003ca href=\"\/collections\/fire-alarm-life-safety\"\u003eAll fire alarm \u0026amp; life safety\u003c\/a\u003e · \u003ca href=\"\/collections\/siemens-parts\"\u003eAll Siemens parts\u003c\/a\u003e · \u003ca href=\"\/collections\/notifier-parts\"\u003eNotifier\u003c\/a\u003e · \u003ca href=\"\/collections\/simplex-parts\"\u003eSimplex\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"siemens-fs-mb-main-control-board-for-fire-alarm-control-systems","title":"Siemens FS-MB Main Control Board for Fire Alarm Control Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens FS-MB is a main control board designed to serve as the central processing and communication platform for compatible Siemens fire alarm control systems. It coordinates system logic, device communication, event processing, and monitoring functions to ensure reliable operation of commercial life safety installations.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFS-MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Main Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral fire alarm system controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent addressable fire alarm system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterfaces with compatible Siemens system buses and communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with Siemens I\/O, network, and communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent Processing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm, supervisory, trouble, and system status management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated onboard diagnostics and status monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal fire alarm control panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial, institutional, and industrial fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade printed circuit board assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.0 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e FS-MB\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe FS-MB is part of the Siemens Fire Safety control platform, engineered to manage the core functions of intelligent addressable fire alarm systems. Acting as the primary controller, the board communicates with field devices, input\/output modules, notification circuits, and network interfaces while continuously supervising system operation. It supports programmable fire alarm logic, event logging, diagnostics, and communication with compatible expansion modules to provide scalable system performance. Designed for installation within Siemens fire alarm control panels, the FS-MB delivers dependable processing capability for commercial, institutional, and industrial fire protection applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain System Controller: Serves as the primary processing board for compatible Siemens fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eIntelligent System Management: Controls alarm, supervisory, and trouble processing functions.\u003c\/li\u003e\n\u003cli\u003eAddressable Device Communication: Supports communication with compatible intelligent field devices.\u003c\/li\u003e\n\u003cli\u003eExpansion Module Support: Interfaces with compatible input, output, communication, and network modules.\u003c\/li\u003e\n\u003cli\u003eContinuous System Supervision: Monitors hardware, communication, and connected devices for reliable operation.\u003c\/li\u003e\n\u003cli\u003eEvent Processing: Manages alarm priorities, system logic, and event reporting.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Functions: Provides onboard diagnostics for simplified troubleshooting and maintenance.\u003c\/li\u003e\n\u003cli\u003eNetwork Integration: Supports communication with compatible Siemens fire alarm network components.\u003c\/li\u003e\n\u003cli\u003eCommercial-Grade Design: Engineered for continuous operation in life safety applications.\u003c\/li\u003e\n\u003cli\u003eOEM Siemens Hardware: Manufactured for seamless integration with compatible fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eScalable Architecture: Supports future system expansion through compatible accessories.\u003c\/li\u003e\n\u003cli\u003eReliable Performance: Designed for long-term operation in demanding commercial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FS-MB delivers the reliability and precision required for central control and intelligent system management in commercial fire alarm installations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104667246848,"sku":"FS-MB","price":3144.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_60b696ea-7140-46fc-abc0-a043d46513fa.webp?v=1785530166"},{"product_id":"siemens-cerberus-pyrotronics-tri-60r-addressable-relay-interface-module","title":"Siemens Cerberus Pyrotronics TRI-60R Addressable Relay Interface Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens TRI-60R is an addressable relay interface module designed to connect dry-contact and shorting devices to compatible Siemens Cerberus Pyrotronics fire alarm systems. Engineered for dependable monitoring and control, the module provides seamless integration with XL3 and MXL addressable systems while maintaining reliable life safety communication.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Cerberus Pyrotronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTRI-60R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Relay Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTRI-60 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay and dry-contact interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Cerberus Pyrotronics XL3, MXL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINX Addressable Module, IXL ICON-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMXL ALD addressable loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous monitoring of connected devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm monitoring and control interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal panel or field enclosure mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor commercial installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial electronic interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.4 lb (0.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e TRI-60R\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe TRI-60R is part of the Siemens Cerberus Pyrotronics TRI-60 series of addressable interface modules, developed to expand the functionality of intelligent fire alarm systems by interfacing external contact devices. It communicates with compatible XL3 systems through INX addressable modules or IXL ICON-1 interfaces and connects directly to MXL ALD loop circuits for distributed monitoring and control applications. The module supervises connected field devices while providing addressable identification, allowing the fire alarm control panel to accurately identify device status and alarm conditions. Its compact industrial design makes it suitable for commercial buildings, healthcare facilities, educational campuses, manufacturing plants, and other installations requiring dependable addressable relay interfacing.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable Relay Interface: Integrates external relay and contact devices into Siemens fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eShorting Device Interface: Designed to monitor and interface dry-contact devices.\u003c\/li\u003e\n\u003cli\u003eXL3 Compatibility: Supports Siemens Cerberus Pyrotronics XL3 systems.\u003c\/li\u003e\n\u003cli\u003eMXL Compatibility: Connects directly to Siemens MXL ALD addressable loop circuits.\u003c\/li\u003e\n\u003cli\u003eINX Module Support: Interfaces with compatible INX addressable modules.\u003c\/li\u003e\n\u003cli\u003eIXL ICON-1 Compatibility: Supports operation with Siemens IXL ICON-1 interfaces.\u003c\/li\u003e\n\u003cli\u003eAddressable Identification: Reports individual device status to the control panel.\u003c\/li\u003e\n\u003cli\u003eContinuous Supervision: Monitors connected circuits for reliable operation.\u003c\/li\u003e\n\u003cli\u003eCompact Module Design: Simplifies installation within compatible fire alarm enclosures.\u003c\/li\u003e\n\u003cli\u003eCommercial Reliability: Engineered for continuous life safety operation.\u003c\/li\u003e\n\u003cli\u003eOEM Siemens Construction: Manufactured for seamless compatibility with Cerberus Pyrotronics systems.\u003c\/li\u003e\n\u003cli\u003eFlexible Integration: Supports a variety of initiating and control applications within addressable fire alarm networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TRI-60R delivers the reliability and precision required for addressable relay interfacing in commercial fire alarm and life safety systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104667377920,"sku":"TRI-60R","price":1468.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_8453f187-a438-4db8-a9d0-83ebedf6cf34.webp?v=1785530170"},{"product_id":"siemens-cmi-300-cxlmxl-fire-alarm-communication-interface-module","title":"Siemens CMI-300 CXL\/MXL Fire Alarm Communication Interface Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens CMI-300 is a communication interface module designed to provide modem-based communication between Siemens MXL fire alarm systems and CXL or NCCNT WAN graphics systems. Installed on the MOM-4 motherboard, the module translates MXL communication signals into CXL modem signals, enabling reliable remote monitoring and system integration.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMI-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Communication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCXL\/MXL Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModem communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Fire Alarm System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens MXL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHost Board\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOM-4 motherboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Communication Boards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMMB-1, MMB-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCXM-1 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNCCNT WAN Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHUB-4 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModem-based serial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf-slot module for MOM-4 board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm network communication and remote monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor commercial installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial electronic communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e CMI-300\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe CMI-300 is part of the Siemens MXL fire alarm communication platform, developed to extend network connectivity between legacy MXL control panels and centralized monitoring or graphics management systems. Installed in a half-slot position on the MOM-4 board, the module interfaces with MMB-1 or MMB-2 communication lines and converts system data for transmission over modem communication links. It supports integration with CXL systems through the CXM-1 interface module and with NCCNT WAN networks through the HUB-4 communication module, allowing centralized supervision of distributed fire alarm installations. Designed for commercial and institutional life safety systems, the CMI-300 provides dependable communication for remote system monitoring, diagnostics, and event reporting.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMXL Communication Interface: Connects Siemens MXL fire alarm systems to external communication networks.\u003c\/li\u003e\n\u003cli\u003eSignal Translation: Converts MXL communication into CXL modem communication signals.\u003c\/li\u003e\n\u003cli\u003eMOM-4 Installation: Installs directly into a half-slot on the Siemens MOM-4 motherboard.\u003c\/li\u003e\n\u003cli\u003eMMB Compatibility: Interfaces with MMB-1 and MMB-2 communication lines.\u003c\/li\u003e\n\u003cli\u003eCXL System Support: Enables communication with Siemens CXL systems through the CXM-1 module.\u003c\/li\u003e\n\u003cli\u003eNCCNT WAN Integration: Supports centralized graphics systems using the HUB-4 interface.\u003c\/li\u003e\n\u003cli\u003eRemote System Monitoring: Provides reliable communication for off-site supervision and diagnostics.\u003c\/li\u003e\n\u003cli\u003eOEM Siemens Module: Designed for seamless integration with Siemens fire alarm architecture.\u003c\/li\u003e\n\u003cli\u003eModular Design: Simplifies installation, maintenance, and future system expansion.\u003c\/li\u003e\n\u003cli\u003eCommercial Life Safety Application: Suitable for large distributed fire alarm installations.\u003c\/li\u003e\n\u003cli\u003eReliable Data Transmission: Maintains dependable communication between connected systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial-Grade Construction: Built for continuous operation in mission-critical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CMI-300 delivers the reliability and precision required for communication and network integration in Siemens MXL fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104667410688,"sku":"CMI-300","price":1347.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_9f673804-0a8d-4f35-a03d-74364ff7d8a8.webp?v=1785530170"},{"product_id":"siemens-500-895955-smb-2-chip-set-upgrade-kit-for-fire-alarm-systems","title":"Siemens 500-895955 SMB-2 Chip Set Upgrade Kit for Fire Alarm Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens 500-895955 SMB-2 Chip Set Upgrade Kit is a firmware upgrade kit designed to update compatible Siemens fire alarm control panels with the SMB-2 operating software. It provides the necessary integrated circuit components to enhance system functionality, compatibility, and performance while maintaining reliable operation in commercial fire alarm installations.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003e500-895955\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eFire Alarm Firmware Upgrade Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eSMB-2 Chip Set Upgrade Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eKit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eFirmware\/Chipset Upgrade Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eSMB-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eFire alarm control panel firmware upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eInternal control panel upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eCompatible Siemens fire alarm control panels supporting SMB-2 upgrades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eComponents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eOEM integrated circuit chipset components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003ePurpose\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eSystem firmware and feature enhancement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eInstallation Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eQualified fire alarm service personnel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eSiemens commercial fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eIndoor commercial installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9916%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5882%;\"\u003eApproximately 0.2 lb (0.09 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e 500-895955\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 500-895955 is part of the Siemens Fire Safety upgrade accessory portfolio, developed to modernize compatible fire alarm control equipment through firmware enhancement. The kit contains replacement chipset components that install directly onto supported control panel hardware, allowing system software to be upgraded without replacing the entire controller. Designed for use by qualified fire alarm service technicians, the upgrade helps maintain compatibility with newer system features, communication modules, and field devices. Its OEM construction ensures dependable integration with Siemens life safety systems while supporting long-term maintenance and system lifecycle management.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOEM Upgrade Kit: Genuine Siemens chipset upgrade for compatible fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eSMB-2 Firmware: Updates supported control panels to the SMB-2 software platform.\u003c\/li\u003e\n\u003cli\u003eHardware-Based Upgrade: Includes replacement integrated circuit components for firmware enhancement.\u003c\/li\u003e\n\u003cli\u003eImproved System Compatibility: Supports integration with compatible Siemens fire alarm devices and accessories.\u003c\/li\u003e\n\u003cli\u003eDirect Control Panel Installation: Designed for installation on supported controller boards.\u003c\/li\u003e\n\u003cli\u003eReliable Performance: Maintains dependable operation following system upgrades.\u003c\/li\u003e\n\u003cli\u003eCommercial Fire Safety Application: Intended for professional life safety system maintenance.\u003c\/li\u003e\n\u003cli\u003eLifecycle Extension: Helps extend the service life of compatible fire alarm equipment.\u003c\/li\u003e\n\u003cli\u003eOEM Quality Components: Manufactured to Siemens fire safety specifications.\u003c\/li\u003e\n\u003cli\u003eProfessional Service Component: Designed for installation by qualified technicians.\u003c\/li\u003e\n\u003cli\u003eSeamless Integration: Works with compatible Siemens fire alarm control panel architecture.\u003c\/li\u003e\n\u003cli\u003eEfficient Modernization: Provides a cost-effective alternative to replacing the entire controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 500-895955 delivers the reliability and precision required for upgrading compatible Siemens fire alarm control systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104667672832,"sku":"500-895955","price":3222.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/iqelectro_photo2_3_abe96eae-9e5c-45db-88c3-a5e85ddf5c79.png?v=1785530175"},{"product_id":"siemens-s54430-f313-a1-2020-mpi-r-mini-ir3-flame-detector","title":"Siemens S54430-F313-A1 20\/20 MPI-R Mini IR3 Flame Detector","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens S54430-F313-A1 20\/20 MPI-R is a compact IR3 flame detector designed to provide rapid and reliable flame detection in demanding industrial and hazardous environments. Utilizing triple infrared (IR3) sensing technology, the detector offers fast response to hydrocarbon fires while maintaining excellent immunity to false alarms caused by sunlight, welding, and other non-fire sources.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Detection Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS54430-F313-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIR3 Flame Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\/20 MPI-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini Triple Infrared Flame Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriple Infrared (IR3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetectable Fires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHydrocarbon flame detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90° cone (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast response (typically within a few seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelf-Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous automatic monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact industrial enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm, fault, and communication outputs (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial fire detection and flame monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall or bracket mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.2 lb (1.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e S54430-F313-A1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe S54430-F313-A1 is part of the Siemens 20\/20 MPI-R flame detection series, developed for critical fire protection applications requiring dependable optical flame detection. Its triple infrared sensing technology continuously analyzes flame signatures to distinguish genuine fire events from environmental interference, improving detection accuracy in challenging operating conditions. The mini-version housing allows installation in confined spaces while maintaining a wide field of view and long detection range for industrial process areas. Suitable for petrochemical plants, power generation facilities, offshore platforms, manufacturing sites, and fuel storage areas, the detector integrates easily into compatible fire alarm and fire suppression systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTriple IR (IR3) Technology: Detects hydrocarbon flames using three infrared sensing channels.\u003c\/li\u003e\n\u003cli\u003eFast Flame Detection: Responds rapidly to fire events for improved life safety and asset protection.\u003c\/li\u003e\n\u003cli\u003eMini Compact Design: Space-saving enclosure simplifies installation in confined locations.\u003c\/li\u003e\n\u003cli\u003eHigh False Alarm Immunity: Filters sunlight, welding, hot equipment, and other non-fire radiation sources.\u003c\/li\u003e\n\u003cli\u003eWide Field of View: Provides broad coverage of protected areas.\u003c\/li\u003e\n\u003cli\u003eLong Detection Distance: Suitable for monitoring large industrial process zones.\u003c\/li\u003e\n\u003cli\u003eIndustrial-Grade Construction: Designed for continuous operation in demanding environments.\u003c\/li\u003e\n\u003cli\u003eMultiple Output Options: Supports integration with compatible fire alarm and suppression systems.\u003c\/li\u003e\n\u003cli\u003eLED Status Indication: Provides clear visual indication of operating and alarm conditions.\u003c\/li\u003e\n\u003cli\u003eHazardous Area Application: Suitable for industrial fire detection installations requiring reliable flame monitoring.\u003c\/li\u003e\n\u003cli\u003eLow Maintenance Design: Optical sensing system minimizes routine service requirements.\u003c\/li\u003e\n\u003cli\u003eContinuous Self-Diagnostics: Monitors internal electronics to ensure dependable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe S54430-F313-A1 delivers the reliability and precision required for rapid flame detection in industrial fire protection and hazardous process applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104667738368,"sku":"S54430-F313-A1","price":4905.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/P_BT01_XX_06964i.jpg?v=1785530177"},{"product_id":"siemens-fn2006-u1-single-mode-fiber-optic-interface-module-for-fire-alarm-networks","title":"Siemens FN2006-U1 Single-Mode Fiber-Optic Interface Module for Fire Alarm Networks","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens FN2006-U1 is a single-mode fiber-optic interface module designed to transmit RS-485 and X-NET\/SafeDlink communication between compatible Siemens fire alarm control panels and fire terminals. It extends network connectivity over long-distance fiber-optic links, providing reliable communication for distributed commercial and industrial life safety systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 509.438px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFN2006-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFiber-Optic Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSingle-Mode Fiber Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eDuplex 9\/125 µm single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eFiber Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSC duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eRS-485, X-NET, SafeDlink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003eFC2025\/FC2050 FACP or regulated 24 VDC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Power Supplies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003ePAD-3, PAD-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Fiber Segment Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003e131,000 ft (40 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Network Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003e131,000 ft (40 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eDaisy-chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Control Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSiemens FC2025, FC2050, FireFinder XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eSiemens FT2050 Fire Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003eDesigo 1HU or 2HU enclosure, COM-BRK for FireFinder XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eFM Approved, CSFM Listed, FDNY Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 39.1875px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 39.1875px;\"\u003eFiber-optic communication for fire alarm networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.7203%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.9602%; height: 19.5938px;\"\u003eApproximately 1.0 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e FN2006-U1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe FN2006-U1 is part of the Siemens Desigo Fire Safety fiber-optic networking solution, developed for FC2025 and FC2050 fire alarm control panels, FT2050 Fire Terminal units, and compatible FireFinder XLS systems. Operating with duplex 9\/125 µm single-mode fiber, the module converts copper-based communication to optical transmission, allowing network expansion well beyond the limitations of standard RS-485 wiring. It supports peer-to-peer X-NET and SafeDlink communication in daisy-chain network configurations while maintaining high communication reliability between distributed fire alarm nodes. Powered from a compatible fire alarm control panel or an approved regulated 24 VDC supply, the module is engineered for dependable operation in mission-critical life safety installations.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-Mode Fiber Interface: Utilizes duplex 9\/125 µm single-mode fiber for long-distance communication.\u003c\/li\u003e\n\u003cli\u003eX-NET Communication: Supports Siemens X-NET peer-to-peer networking.\u003c\/li\u003e\n\u003cli\u003eSafeDlink Support: Enables SafeDlink communication between compatible fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eRS-485 Transmission: Converts RS-485 communication to fiber-optic transmission.\u003c\/li\u003e\n\u003cli\u003eLong-Distance Networking: Supports fiber segments up to 40 km (131,000 ft).\u003c\/li\u003e\n\u003cli\u003eDaisy-Chain Topology: Designed for distributed network architectures.\u003c\/li\u003e\n\u003cli\u003e24 VDC Operation: Powered directly from compatible Siemens fire alarm systems or approved external supplies.\u003c\/li\u003e\n\u003cli\u003eSC Fiber Connectors: Uses standard SC-style duplex fiber connectors.\u003c\/li\u003e\n\u003cli\u003eFireFinder XLS Compatibility: Integrates with compatible FireFinder XLS fire alarm panels.\u003c\/li\u003e\n\u003cli\u003eDesigo Fire Compatibility: Designed for FC2025, FC2050, and FT2050 platforms.\u003c\/li\u003e\n\u003cli\u003eCertified for Life Safety: Approved for commercial fire alarm installations with multiple industry certifications.\u003c\/li\u003e\n\u003cli\u003eReliable Fiber Communication: Maintains secure and stable data transmission across large facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FN2006-U1 delivers the reliability and precision required for long-distance fiber-optic communication in distributed fire alarm and life safety networks.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104667869440,"sku":"FN2006-U1","price":6613.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_4bb870c1-334f-40fa-8497-80cfd463c608.webp?v=1785530181"},{"product_id":"siemens-fn2013-u1-single-mode-fiber-optic-interface-module-for-fire-alarm-systems","title":"Siemens FN2013-U1 Single-Mode Fiber-Optic Interface Module for Fire Alarm Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Siemens FN2013-U1 is a single-mode fiber-optic interface module designed to transmit RS-485 and H-Net communication between compatible Siemens fire alarm control panels over long-distance fiber-optic networks. Powered by 24 VDC, it enables reliable, high-speed communication while extending network reach in large commercial and industrial fire alarm installations.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFN2013-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber-Optic Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplex 9\/125 µm single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSC duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485, H-Net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRepeater or end-point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Fiber Segment Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131,000 ft (40 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Total Network Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70,000 ft (21.3 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDaisy chain or star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 LEDs (Power, TX, RX, Status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigo Fire Safety Modular, Cerberus PRO Modular, FireFinder XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Enclosures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAB-1, CAB-2, CAB-3, CAB-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOM-BRK mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm panel, PSC-12, PSX-12, PAD-3, PAD-4, PAD-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber-optic network communication for fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.0 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan\u003e FN2013-U1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe FN2013-U1 is part of the Siemens fiber-optic communication interface family developed for Desigo Fire Safety Modular, Cerberus PRO Modular, and FireFinder XLS fire alarm systems. It converts copper-based RS-485 communication to single-mode fiber, supporting both repeater and end-point operation for flexible network design. The module supports daisy-chain and star network topologies, allowing installations that exceed the limitations of conventional RS-485 wiring while maintaining dependable H-Net communication between main and remote control panels. Equipped with comprehensive LED diagnostics and designed for installation inside Siemens CAB-series enclosures, it provides a scalable communication solution for large life safety networks.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-Mode Fiber Interface: Supports long-distance communication using 9\/125 µm single-mode fiber.\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication: Converts RS-485 signals to fiber-optic transmission.\u003c\/li\u003e\n\u003cli\u003eH-Net Compatibility: Supports Siemens H-Net communication between compatible control panels.\u003c\/li\u003e\n\u003cli\u003eLong-Distance Transmission: Provides fiber segments up to 131,000 ft (40 km).\u003c\/li\u003e\n\u003cli\u003eFlexible Network Design: Supports both daisy-chain and star network topologies.\u003c\/li\u003e\n\u003cli\u003eRepeater or Endpoint Mode: Configurable for network expansion or termination.\u003c\/li\u003e\n\u003cli\u003eLED Diagnostics: Ten onboard LEDs provide power, transmit, receive, and status indication.\u003c\/li\u003e\n\u003cli\u003e24 VDC Powered: Operates directly from compatible Siemens fire alarm power supplies.\u003c\/li\u003e\n\u003cli\u003eMultiple Power Options: Compatible with PSC-12, PSX-12, and PAD-3\/4\/5 power supplies.\u003c\/li\u003e\n\u003cli\u003eCAB-Series Mounting: Installs using the COM-BRK mounting plate inside CAB-series enclosures.\u003c\/li\u003e\n\u003cli\u003eCommercial Reliability: Engineered for mission-critical fire alarm communication networks.\u003c\/li\u003e\n\u003cli\u003eSeamless System Integration: Designed for Desigo FSM, Cerberus PRO Modular, and FireFinder XLS systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FN2013-U1 delivers the reliability and precision required for long-distance fiber-optic communication in commercial fire alarm and life safety networks.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104667836672,"sku":"FN2013-U1","price":10288.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_ad5090ad-d535-4fe9-925e-2175d94da38d.webp?v=1785530181"},{"product_id":"siemens-hfp-11-multi-sensor-smoke-detector-fireprint-photoelectric-thermal","title":"Siemens HFP-11 Multi-Sensor Smoke Detector FirePrint Photoelectric Thermal","description":"\u003ch4 data-end=\"16\" data-start=\"0\"\u003eDescription\u003c\/h4\u003e\n\u003cp data-end=\"404\" data-start=\"17\"\u003eThe Siemens HFP-11 is a multi-sensor smoke detector designed for advanced fire detection using both photoelectric and thermal sensing technologies. It integrates intelligent signal processing to accurately distinguish between real fire conditions and nuisance sources. This detector is commonly used in commercial fire alarm systems requiring reliable and adaptive detection performance.\u003c\/p\u003e\n\u003cp data-end=\"404\" data-start=\"17\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"404\" data-start=\"17\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"404\" data-start=\"17\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHFP-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoke Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotoelectric + Thermal (Multi-Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFirePrint™ Intelligent Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplied by Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireFinder XLS, FS-250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface Mount Base (DB-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 38 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 93% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Spacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ft (900 sq ft coverage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-profile plastic housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, NFPA 72 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-end=\"404\" data-start=\"17\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"404\" data-start=\"17\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"428\" data-start=\"406\"\u003eInformation About HFP-11\u003c\/h4\u003e\n\u003cp data-end=\"1053\" data-start=\"429\"\u003eThe HFP-11 is part of Siemens’ Fire Safety detection portfolio, engineered for use with FireFinder XLS and FS-250 control panels. It features a two-wire, plug-in design that simplifies installation and maintenance while ensuring reliable communication with the control system. The detector incorporates FirePrint™ technology, which analyzes both smoke and temperature data using onboard microprocessor logic to reduce false alarms. Built with a dust-resistant optical chamber and solid-state thermal sensor, it is suitable for a wide range of environments, including offices, industrial spaces, and specialized hazard areas.\u003c\/p\u003e\n\u003cp data-end=\"1072\" data-start=\"1055\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2004\" data-start=\"1073\"\u003e\n\u003cli data-end=\"1165\" data-start=\"1073\"\u003eMulti-Sensor Detection: Combines photoelectric and thermal sensing for enhanced accuracy\u003c\/li\u003e\n\u003cli data-end=\"1270\" data-start=\"1166\"\u003eFirePrint™ Technology: Uses advanced algorithms to differentiate real fires from nuisance conditions\u003c\/li\u003e\n\u003cli data-end=\"1345\" data-start=\"1271\"\u003eTwo-Wire System: Simplifies installation and reduces wiring complexity\u003c\/li\u003e\n\u003cli data-end=\"1436\" data-start=\"1346\"\u003eMicroprocessor-Based Operation: Provides intelligent signal processing and diagnostics\u003c\/li\u003e\n\u003cli data-end=\"1526\" data-start=\"1437\"\u003eField-Cleanable Chamber: Dust-resistant design allows maintenance without replacement\u003c\/li\u003e\n\u003cli data-end=\"1608\" data-start=\"1527\"\u003eInfrared Optical Sensing: IR LED and photodiode ensure stable smoke detection\u003c\/li\u003e\n\u003cli data-end=\"1699\" data-start=\"1609\"\u003eThermal Sensing Element: Solid-state thermistor detects temperature changes accurately\u003c\/li\u003e\n\u003cli data-end=\"1767\" data-start=\"1700\"\u003ePlug-In Design: Enables quick installation and easy replacement\u003c\/li\u003e\n\u003cli data-end=\"1856\" data-start=\"1768\"\u003eProgrammable Applications: Supports multiple hazard profiles for optimized detection\u003c\/li\u003e\n\u003cli data-end=\"1932\" data-start=\"1857\"\u003eSelf-Diagnostics: Continuously monitors detector status and performance\u003c\/li\u003e\n\u003cli data-end=\"2004\" data-start=\"1933\"\u003eCompatibility: Works with Siemens FireFinder XLS and FS-250 systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2130\" data-start=\"2006\"\u003eThe HFP-11 delivers the reliability and precision required for intelligent fire detection and life safety system monitoring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104745234688,"sku":"HFP-11","price":221.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_d14d392a-e328-46be-a1ac-cef121a67f1f.webp?v=1785531868"},{"product_id":"ili-1b-siemens-intelligent-ionization-smoke-detector-for-ixl-mxl-xl3-fire-alarm-systems","title":"ILI-1B | Siemens Intelligent Ionization Smoke Detector for IXL MXL XL3 Fire Alarm Systems","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Siemens ILI-1B is an intelligent ionization smoke detector designed for advanced fire detection in commercial and industrial safety systems. Engineered for use with compatible Siemens fire alarm control panels, the Siemens ILI-1B provides precise smoke detection, reliable communication, and stable performance in air duct monitoring applications. Its microprocessor-based design ensures accurate detection and dependable system integration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eILI-1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoke Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent Ionization Smoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens IXL, MXL, XL3 Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAD-3I Air Duct Detector Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 – 30 VDC Peak Pulsed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Normal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 mA Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Alarm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 100°F (0°C to 38°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 93% RH Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Tools\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensorLINK FPI-32 \/ DPU Programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.62 × 5.62 × 2.67 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, ULC, FM, CSFM, NYMEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About ILI-1B\u003c\/h4\u003e\n\u003cp\u003eThe ILI-1B is part of the Siemens ILI Series intelligent ionization smoke detectors developed for integration with Siemens fire alarm control systems. It features dual ionization chambers and solid-state circuitry designed to provide high resistance to environmental interference such as EMI, RFI, and humidity. The detector is specifically intended for use with the AD-3I air duct housing when monitoring airflow in HVAC duct systems with velocities between 500 and 4000 ft\/min. Built with a Motorola microprocessor and onboard EEPROM, the device supports advanced detection algorithms, electronic addressing, and system supervision through compatible field programming tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Ionization Chamber Detection: Provides highly sensitive smoke detection using self-compensating dual ionization chambers.\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-Based Operation: Integrated Motorola microprocessor enables advanced detection algorithms and system diagnostics.\u003c\/li\u003e\n\u003cli\u003eEEPROM Memory Integration: Onboard EEPROM stores device programming and configuration data for reliable system operation.\u003c\/li\u003e\n\u003cli\u003eAir Duct Monitoring Capability: Designed for use with Siemens AD-3I duct detector housing for HVAC air duct smoke detection.\u003c\/li\u003e\n\u003cli\u003eAdvanced Communication Protocol: Supports intelligent communication with Siemens fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eHigh Interference Resistance: Solid-state circuitry ensures strong immunity to EMI, RFI, and humidity conditions.\u003c\/li\u003e\n\u003cli\u003eField Programmable Addressing: Compatible with SensorLINK FPI-32 and DPU programmers for electronic addressing and testing.\u003c\/li\u003e\n\u003cli\u003eVisual Alarm Indication: Built-in LED indicator provides clear visual status and alarm signaling.\u003c\/li\u003e\n\u003cli\u003eCertified Safety Compliance: UL, ULC, FM, CSFM, and NYMEA approvals ensure compliance with fire protection standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ILI-1B delivers the reliability and precision required for intelligent smoke detection in commercial fire alarm and HVAC duct monitoring systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49104812638464,"sku":"ILI-1B","price":880.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ILI-1B-768x768.jpg?v=1785533557"},{"product_id":"ps-35-siemens-system-3-power-supply-500-884950-for-cp-35-fire-alarm-control","title":"PS-35 | Siemens System 3 Power Supply 500-884950 for CP-35 Fire Alarm Control","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens PS-35 Power Supply (500-884950) is a robust step-down transformer and bridge rectifier assembly engineered for use with Siemens System 3 fire alarm control panels, specifically the CP-35 model. It provides regulated DC power to support notification appliance circuits (NACs) and auxiliary devices within life safety systems. Designed for dependable performance, the PS-35 ensures stable power distribution to enhance the reliability of connected fire alarm components.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500-884950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens System 3, CP-35 Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStep-down transformer and bridge rectifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegulated DC for NAC and auxiliary devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal and overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal enclosure, industrial-grade components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed for fire alarm applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm and life safety systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.54 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003ePS-35\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PS-35 is a Siemens System 3-series power supply module developed to provide additional DC current capacity for fire alarm and notification systems. It is typically installed alongside the CP-35 control panel, where it converts AC input to regulated DC output for consistent and safe operation of alarm devices. The unit integrates both a step-down transformer and a bridge rectifier, allowing efficient voltage conversion and rectification in one enclosure. Built for long-term durability and reliability, the PS-35 meets the stringent requirements of commercial and institutional fire protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Power Conversion: Combines a transformer and rectifier to supply DC voltage for fire alarm circuits.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed specifically for Siemens System 3 panels, including CP-35.\u003c\/li\u003e\n\u003cli\u003eStable DC Output: Ensures reliable operation of notification appliances and auxiliary modules.\u003c\/li\u003e\n\u003cli\u003eRugged Construction: Built with industrial-grade components for continuous-duty applications.\u003c\/li\u003e\n\u003cli\u003eThermal Protection: Safeguards internal components from overheating under high load.\u003c\/li\u003e\n\u003cli\u003eMounting Flexibility: Compact and secure mounting within System 3 enclosures.\u003c\/li\u003e\n\u003cli\u003eService Friendly: Simple terminal layout for efficient installation and maintenance.\u003c\/li\u003e\n\u003cli\u003eUL Compliance: Meets safety and performance standards for fire system power equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PS-35 delivers the reliability and precision required for continuous power support in critical fire alarm and life safety systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105126981888,"sku":"PS-35","price":1990.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/dscn0130.png?v=1785540870"},{"product_id":"fn2007-u1-siemens-multi-mode-fiber-optic-interface-module-for-rs-485-fire-panel-networking","title":"FN2007-U1 | Siemens Multi-Mode Fiber Optic Interface Module for RS-485 Fire Panel Networking","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens FN2007-U1 is a multi-mode fiber-optic interface module designed to reliably convert and extend RS-485 network communication across a high-speed fiber-optic link. This module ensures noise-immune data transfer for critical Siemens Modular fire-alarm control panels (FACPs) and fire terminals over long distances. Its robust design allows for essential integration into networked fire-system infrastructure where electrical isolation and extended signal reach are required.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable data-sheets-baot=\"1\" data-sheets-root=\"1\" border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"width: 102.082%; height: 332px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"100\" style=\"width: 50.8935%;\"\u003e \u003ccol width=\"100\" style=\"width: 49.131%;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNew\/Never Used Surplus\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eFire Alarm Control\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eFN2007-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNetwork Interface Modules\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eMedia Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eMulti-Mode Fiber Optic\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e24 VDC (Nominal)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eUL Listed, regulated 24VDC fire-system power supply\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eSiemens Modular Systems (50-, 252-, 504-point FACPs, FT924 terminals)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eEA (Each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eFN2007-U1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FN2007-U1 is a component within the Siemens Desigo Fire Safety series, crafted for seamless integration into existing and new fire safety infrastructures. Built for durability, this module serves as a critical network component, extending the reach of data communication in large or complex facilities. It is compatible with various Siemens fire systems, including the 50-point, 252-point, and 504-point FACPs, along with the FT924 fire terminals. The module utilizes multi-mode fiber-optic technology to securely transmit the RS-485 signaling protocol, powered by a nominal 24 Volts DC fire-system supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-Mode Fiber Optic: Enables network communication across a robust, long-distance multi-mode fiber-optic link, isolating data from electrical noise.\u003c\/li\u003e\n\u003cli\u003eRS-485 Protocol Support: Designed specifically to transmit the Siemens proprietary RS-485 communication signals for network connectivity.\u003c\/li\u003e\n\u003cli\u003eWide System Compatibility: Integrates seamlessly with Siemens Modular systems, including multiple FACP models and FT924 fire terminals.\u003c\/li\u003e\n\u003cli\u003eNominal 24VDC Power: Operates using standard nominal 24 Volts DC power, typically supplied by a regulated, UL Listed fire-system power source.\u003c\/li\u003e\n\u003cli\u003eHigh-Speed Data Transmission: Facilitates the rapid and reliable transfer of critical fire alarm and status data between networked control units.\u003c\/li\u003e\n\u003cli\u003eModular System Integration: Functions as an interface module within the network architecture of the larger Siemens fire control infrastructure.\u003c\/li\u003e\n\u003cli\u003eEnhanced Network Distance: Extends the maximum allowable communication distance between networked control panels compared to traditional copper wiring.\u003c\/li\u003e\n\u003cli\u003eIndustrial Reliability: Constructed to meet the stringent performance and regulatory requirements of commercial and industrial fire safety applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FN2007-U1 delivers the reliability and precision required for maintaining uninterrupted, high-integrity data communication across networked fire-alarm and control systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105128587520,"sku":"FN2007-U1","price":749.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-10-18_23.38.03.png?v=1785540915"},{"product_id":"mlc-siemens-mxl-addressable-device-line-card-for-fire-alarm-systems","title":"MLC | Siemens MXL Addressable Device Line Card for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens MLC is an MXL addressable device line card designed for integration with FireFinder XLS, Desigo Fire Safety Modular, and Cerberus PRO Modular systems. The MLC supports up to 60 intelligent devices per loop and provides monitoring, control, and communication for detectors, manual stations, and control devices. With onboard diagnostics and firmware update capabilities, the MLC ensures reliable operation and simplified management of fire alarm systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreaker Panels and Load Centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Load Centers \u0026amp; Panel Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMXL Addressable Device Line Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 loops, 60 devices per loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHNET, consecutive addresses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic LEDs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 LEDs for status and fault monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Upgrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB port for front panel firmware upload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated on each loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel reset switch included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireFinder XLS, Desigo Fire Safety Modular, Cerberus PRO Modular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 × 12.5 × 7.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eMLC\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe MLC is part of Siemens’ MXL series of line cards, engineered for modular, intelligent fire alarm systems. It features a dual-loop design, with each loop supporting up to 60 devices and device accessories. The board integrates onboard microprocessor control, fault detection, and device communication, allowing independent operation even if the central control module fails. Its compatibility with multiple Siemens modular systems and USB firmware upload ensures flexible installation and easy maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Loop Support: Manages two separate loops with up to 60 devices per loop.\u003c\/li\u003e\n\u003cli\u003eIntelligent Device Control: Supports smoke detectors, manual stations, and control devices.\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-Based: Ensures module operation and alarm initiation independently of central control.\u003c\/li\u003e\n\u003cli\u003eDiagnostic LEDs: Nine LEDs provide real-time status, fault, and alarm indications.\u003c\/li\u003e\n\u003cli\u003eUSB Firmware Upload: Enables easy firmware updates via front panel USB port.\u003c\/li\u003e\n\u003cli\u003eGround Fault Detection: Monitors and signals wiring faults on the loops.\u003c\/li\u003e\n\u003cli\u003eHNET Network Integration: Each loop uses consecutive addresses for seamless system communication.\u003c\/li\u003e\n\u003cli\u003eReset Function: Front panel reset switch reinitializes the module as needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MLC delivers the reliability and precision required for managing multiple intelligent fire alarm devices in complex modular systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105128849664,"sku":"MLC","price":2203.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-10-18_20.59.05.png?v=1785540923"},{"product_id":"fci2017-u1-siemens-500-point-periphery-board-for-fire-alarm-systems","title":"FCI2017-U1 | Siemens 500-Point Periphery Board for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens FCI2017-U1 is a periphery board designed for use in Siemens fire control panels, including voice alarm systems. This 500-point PCB provides monitoring, control, and power distribution for detectors, notification devices, and auxiliary modules. With thermal protection and built-in NAC circuits, the FCI2017-U1 ensures reliable system operation and connectivity in complex fire alarm setups.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreaker Panels and Load Centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCI2017-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Load Centers \u0026amp; Panel Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e504 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Circuit Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3A per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5A, 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 100 Ah batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFP2011 (170W), FP2012 (300W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded for external device control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS100 Reset periphery board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 circuits for detectors and drivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted in Siemens enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, UL Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e FCI2017-U1\u003c\/h4\u003e\n\u003cp\u003eThe FCI2017-U1 is part of the Siemens periphery board family, specifically engineered for panels supporting up to 504 device points. It features a modular design with dedicated terminals for power supplies, battery connections, and NAC circuits. The board is compatible with both class A and class B notification appliance circuits and integrates relays, detector circuits, and reset functions. Its robust construction ensures stable performance in fire alarm systems, while providing easy expansion and fault monitoring capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Capacity: Supports up to 504 device points for extensive fire system coverage.\u003c\/li\u003e\n\u003cli\u003eNAC Circuit Integration: Provides up to 3A per NAC circuit for class A or class B configurations.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Output: 24V DC output to power remote modules or internal devices.\u003c\/li\u003e\n\u003cli\u003eBattery Management: Built-in charger and switchover for AC fail or brownout conditions.\u003c\/li\u003e\n\u003cli\u003eDetector Support: Dedicated circuits for reliable connection of smoke and heat detectors.\u003c\/li\u003e\n\u003cli\u003eRelay Integration: Multiple relay terminals for external device control.\u003c\/li\u003e\n\u003cli\u003eReset Function: S100 reset button allows system-wide periphery board resets.\u003c\/li\u003e\n\u003cli\u003eExpansion Ready: Supports leased line\/city tie operation and additional NAC circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FCI2017-U1 delivers the reliability and precision required for managing complex fire alarm and voice alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105128915200,"sku":"FCI2017-U1","price":3564.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-10-18_20.48.49.png?v=1785540925"},{"product_id":"zac-40-siemens-40w-zone-amplifier-card-for-cerberus-pro-modular-fire-alarm-systems","title":"ZAC-40 | Siemens 40W Zone Amplifier Card for Cerberus PRO Modular Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens ZAC-40 is a 40-watt Zone Amplifier Card designed for use with Cerberus PRO Modular fire alarm panels. It functions as both an amplifier and speaker-zone interface, providing high-quality audio signal distribution across up to eight digital audio channels. The unit supports 25VRMS or 70VRMS power-limited operation, ensuring reliable performance in supervised voice evacuation and notification systems.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZAC-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZone Amplifier Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25VRMS or 70VRMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio Channels Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 (Digital Audio Bus via DAC-NET)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Styles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStyle Y, Style Z, Split-Zone (A\/B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull amplifier and speaker line supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in card for CC-2 or CC-5 Card Cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCerberus PRO Modular Fire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASI (Audio Serial Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal audio input supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with EBA2004-A1 booster amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL864 \u0026amp; CAN\/ULC-S576 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower-limited circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 × 8 × 3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eZAC-40\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ZAC-40 is a plug-in amplifier module that installs directly into the Siemens CC-5 or CC-2 card cage, offering seamless integration with Cerberus PRO Modular fire alarm control systems. It supports Style Y, Z, or split-zone (A\/B) wiring configurations and maintains full supervision for functionality and speaker line integrity. Capable of amplifying any of the eight digital-audio channels from the DAC-NET Digital Audio Card via the ASI (Audio Serial Interface) bus, the ZAC-40 provides flexible zone assignment and high-efficiency sound output. The amplifier can also function as a bulk amplifier feeding high-level audio to ZIC or HCP components, or expand coverage using the EBA2004-A1 booster amplifier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Power Output: Provides 40 watts of supervised audio amplification for voice communication and notification.\u003c\/li\u003e\n\u003cli\u003eSelectable Voltage Levels: Operates at either 25VRMS or 70VRMS for flexible system compatibility.\u003c\/li\u003e\n\u003cli\u003eMulti-Zone Support: Handles up to eight digital audio channels via the DAC-NET interface.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: Constantly monitors amplifier functionality and speaker line status.\u003c\/li\u003e\n\u003cli\u003eFlexible Wiring Options: Supports Style Y, Z, and A\/B split-zone wiring configurations.\u003c\/li\u003e\n\u003cli\u003eCompact Plug-In Design: Mounts easily into Siemens CC-2 or CC-5 card cages for modular installation.\u003c\/li\u003e\n\u003cli\u003eExpandable System Design: Compatible with EBA2004-A1 booster amplifiers for additional audio zones.\u003c\/li\u003e\n\u003cli\u003eUL864 \u0026amp; ULC Certified: Meets strict fire alarm and life safety system standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ZAC-40 delivers the reliability and precision required for advanced voice evacuation, emergency notification, and fire alarm communication systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105130553600,"sku":"ZAC-40","price":807.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PR-F1P1-7903.jpg?v=1785540941"},{"product_id":"nim-1w-siemens-xnet-network-interface-module-for-mxlxls-fire-alarm-systems","title":"NIM-1W | Siemens XNET Network Interface Module for MXL\/XLS Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens NIM-1W Network Interface Module provides advanced networking capability for Siemens MXL and XLS fire alarm systems. It enables the interconnection of up to 63 panels through the XNET communication network, ensuring centralized monitoring, control, and coordination. Designed for large-scale fire safety systems, the NIM-1W enhances system reliability, scalability, and performance in complex building networks.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm System Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNIM-1W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXNET Fire Alarm Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens MXL and XLS Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Platforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens NCC and Desigo CC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSG-M Version 6.01 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Connected Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStyle 4 or Style 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Functionality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitoring and control across connected panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplied through system backplane connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack-mountable module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor, controlled conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.34 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e\u003cmeta charset=\"utf-8\"\u003eNIM-1W\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe NIM-1W is a Siemens XNET network interface module designed to link multiple MXL and XLS control panels into a unified communication network. It supports bidirectional data transfer for real-time control and supervision and integrates seamlessly with Siemens supervisory platforms such as Desigo CC and NCC. Using CSG-M programming software (version 6.01 or higher), users can define output logic between panels for coordinated alarm responses and system-wide control. Each connected system is assigned a unique panel number, allowing precise interactive programming and efficient event management across the entire network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXNET Networking Interface: Connects up to 63 MXL and XLS systems to form a unified Siemens fire network.\u003c\/li\u003e\n\u003cli\u003eComprehensive System Integration: Supports Siemens NCC and Desigo CC for centralized monitoring and control.\u003c\/li\u003e\n\u003cli\u003eAdvanced Programming Logic: Enables interactive programming via CSG-M version 6.01 and higher.\u003c\/li\u003e\n\u003cli\u003eFlexible Wiring Options: Configurable for both Style 4 and Style 7 network topologies.\u003c\/li\u003e\n\u003cli\u003eHigh-Speed Communication: Provides fast and reliable data exchange between connected panels.\u003c\/li\u003e\n\u003cli\u003eFault-Tolerant Design: Maintains communication integrity even under network disruption or hardware failure.\u003c\/li\u003e\n\u003cli\u003ePanel Number Assignment: Assigns unique identifiers for each system to ensure accurate data routing.\u003c\/li\u003e\n\u003cli\u003eRobust Build Quality: Designed for consistent operation in demanding industrial and commercial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NIM-1W delivers the reliability and precision required for advanced, large-scale fire alarm networking and centralized system management.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105131045120,"sku":"NIM-1W","price":1362.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/159523_1000x1000_928b5d99-161b-4398-9268-238c79cfc569.png?v=1785540956"},{"product_id":"fdbz-wt-siemens-weather-tight-enclosure-for-fdbz492-series-duct-smoke-detectors","title":"FDBZ-WT | Siemens Weather-Tight Enclosure for FDBZ492-Series Duct Smoke Detectors","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens FDBZ-WT Weather-Tight Enclosure provides watertight protection for Siemens FDBZ492-series duct smoke detector housings. Designed for installation in environments exposed to moisture, dust, or outdoor conditions, it ensures continuous operation and reliability of duct-mounted smoke detection systems. The enclosure’s robust design makes it ideal for industrial, commercial, and outdoor applications requiring durable environmental protection.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm System Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFDBZ-WT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeather-Tight Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Models\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens FDBZ492-Series Duct Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCorrosion-resistant industrial-grade construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor or outdoor installation in high-moisture environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWater, humidity, and dust protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface-mounted enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets fire safety equipment enclosure standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial, commercial, and outdoor fire detection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eFDBZ-WT\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FDBZ-WT is a specialized protective enclosure designed for Siemens FDBZ492-series duct detector housings. It allows the housing to be installed within a sealed, NEMA 4X-rated environment, maintaining system integrity in areas with high humidity or airborne contaminants. Built with corrosion-resistant materials, it effectively prevents water ingress and mechanical damage. The enclosure supports secure integration with Siemens fire alarm systems, extending the lifespan and reliability of smoke detection components in challenging environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWatertight Protection: Provides full enclosure sealing to protect duct smoke detectors from water, humidity, and condensation.\u003c\/li\u003e\n\u003cli\u003eOutdoor and Indoor Use: Suitable for both outdoor applications and areas with high moisture levels.\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Construction: Built to meet industrial standards for corrosion and environmental resistance.\u003c\/li\u003e\n\u003cli\u003eDurable Build: Fabricated from high-quality materials for long-term mechanical stability and protection.\u003c\/li\u003e\n\u003cli\u003eSeamless Compatibility: Designed specifically for Siemens FDBZ492-series duct housings for direct installation.\u003c\/li\u003e\n\u003cli\u003eEnhanced Safety Compliance: Helps maintain compliance with fire protection and life safety standards.\u003c\/li\u003e\n\u003cli\u003eEasy Integration: Facilitates quick mounting and wiring within Siemens detection systems.\u003c\/li\u003e\n\u003cli\u003eLow Maintenance Design: Ensures minimal servicing requirements while maintaining protection performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FDBZ-WT delivers the reliability and precision required for maintaining duct smoke detection performance in harsh or moisture-prone environments.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105131143424,"sku":"FDBZ-WT","price":1158.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/152005_512x512_a7d065cc-2f64-4f25-a79e-3f328fd495dc.jpg?v=1785540958"},{"product_id":"ald-2i-siemens-analog-loop-driver-module-for-mxl-iq-fire-alarm-systems","title":"ALD-2I | Siemens Analog Loop Driver Module for MXL-IQ Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"402\" data-start=\"86\"\u003eThe Siemens ALD-2I is an analog loop driver module designed for MXL-IQ life safety systems. It provides two intelligent analog circuits compatible with Cerberus Pyrotronics “I” type devices, allowing integration of up to 120 addressable input and output components across Style 4 or Style 6 configurations.\u003c\/p\u003e\n\u003ch3 data-end=\"534\" data-start=\"502\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eFire Alarm System Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eALD-2I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eAnalog Loop Driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eMXL-IQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003ePC Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eLoop Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003e2 Intelligent Analog Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eSupported Devices per Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eUp to 60 Programmable Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eSupported Device Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eCerberus Pyrotronics “I” Series Intelligent Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eCircuit Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eStyle 4 or Style 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eAddressable Analog Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eFrom MXL-IQ Main Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003ePlug-in Module \/ Panel Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eExpansion of Fire Alarm System Device Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003e14 × 14 × 3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eIndoor, Life Safety System Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eEnclosure Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eInstalled within MXL-IQ Cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003eUL Listed, NFPA 72 Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5269%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.34%;\"\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eALD-2I\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ALD-2I is a Siemens MXL-IQ network option module engineered to expand the system’s capacity for intelligent device monitoring and control. It adds two independent analog loops, each capable of supporting up to 60 Cerberus Pyrotronics “I” type devices, including sensors, modules, and control relays. Each loop can be configured as either Style 4 (Class B) or Style 6 (Class A), offering installation flexibility to meet site-specific wiring and redundancy requirements. Designed as a plug-in printed circuit board, the ALD-2I interfaces directly with the MXL-IQ system backplane, providing reliable communication and enhanced fault tolerance in large-scale fire alarm installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Analog Loops: Provides two intelligent circuits, each supporting up to 60 programmable devices for a total of 120 addressable components.\u003c\/li\u003e\n\u003cli\u003eFlexible Circuit Configuration: Each loop can be wired as Style 4 or Style 6, allowing Class A or Class B operation depending on system design.\u003c\/li\u003e\n\u003cli\u003eIntelligent Device Compatibility: Fully supports Cerberus Pyrotronics “I” series detectors, modules, and notification appliances.\u003c\/li\u003e\n\u003cli\u003ePlug-In PC Board Design: Simplifies installation and maintenance within the MXL-IQ system enclosure.\u003c\/li\u003e\n\u003cli\u003eHigh-Speed Analog Communication: Ensures fast and reliable data exchange with all connected intelligent devices.\u003c\/li\u003e\n\u003cli\u003eSystem Expansion Capability: Increases overall input\/output capacity of the MXL-IQ fire alarm control system.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Fault Monitoring: Continuously supervises loop wiring and device communication for enhanced system safety.\u003c\/li\u003e\n\u003cli\u003eIndustrial-Grade Construction: Designed to maintain performance under continuous operation in critical life safety environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ALD-2I delivers the reliability and precision required for modern fire detection networks, enabling scalable, fault-tolerant control in intelligent life safety systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105132060928,"sku":"ALD-2I","price":1652.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_9c05029a-9d07-40e1-8c1f-33428fe521cb.webp?v=1785540985"},{"product_id":"pad-4-9a-siemens-9-amp-24v-distributed-power-supply-and-nac-expander-for-fire-alarm-systems","title":"PAD-4-9A | Siemens 9 Amp 24V Distributed Power Supply and NAC Expander for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens PAD-4-9A is a distributed power supply and NAC (Notification Appliance Circuit) expander designed to enhance Siemens fire alarm control panels by providing additional 24 V DC power for signaling devices. This model delivers up to 9 amps of total output power, supporting both audible and visual notification appliances compliant with ADA standards. Its fault-tolerant circuitry ensures consistent operation, making it ideal for large commercial, industrial, and institutional fire alarm installations.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePAD-4-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNAC Power Expander\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 × Class B (Expandable to Class A with PAD-4-CLSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × optically isolated NAC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervisory Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForm C (General Trouble and AC Fail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 7 Ah internal; larger capacities supported with optional kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent of primary power fluctuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864 10th Edition, ULC-S527, ADA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed powder-coated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall-mounted enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003ePAD-4-9A\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PAD-4-9A is part of Siemens’ advanced Distributed Power Supply (PAD) Series, built to expand the power and signaling capacity of Siemens FireFinder and other compatible FACPs. It provides four Class B NAC outputs (expandable to Class A with the PAD-4-CLSA module) and a 3 A auxiliary output for auxiliary equipment such as door holders and relays. The unit features integrated supervision for AC loss, ground faults, and battery conditions, ensuring reliable fault reporting through Form C relays. Engineered for long-term performance, the PAD-4-9A maintains a regulated 24 V DC output independent of power source fluctuations, ensuring stable device operation across extended wiring runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh NAC Power Output: Provides up to 9 A of 24 V DC power for notification appliances.\u003c\/li\u003e\n\u003cli\u003eMultiple Circuit Configurations: Supports four Class B circuits, expandable to Class A using the PAD-4-CLSA option.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Power Supply: Delivers 3 A of 24 V DC power for auxiliary devices such as relays and door holders.\u003c\/li\u003e\n\u003cli\u003eSupervised Inputs and Outputs: Monitors AC power, batteries, ground faults, and output integrity through Form C relays.\u003c\/li\u003e\n\u003cli\u003eOptically Isolated NAC Inputs: Ensures reliable signal separation and prevents cross-interference with the main panel.\u003c\/li\u003e\n\u003cli\u003eIntegrated Strobe Synchronization: Supports synchronization modules for consistent strobe operation across zones.\u003c\/li\u003e\n\u003cli\u003eDurable Enclosure Design: Housed in a red, metal enclosure with space for power boards and batteries up to 7 Ah or larger.\u003c\/li\u003e\n\u003cli\u003eSeismic and Safety Certifications: Complies with UL 864 10th Edition, ADA, and IBC\/OSHPD seismic standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD-4-9A delivers the reliability and precision required for critical fire alarm power distribution and signaling system expansion.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105135272192,"sku":"PAD-4-9A","price":1987.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PR-F1P1-6086_600x600_4986e5aa-003c-4fdf-8b3e-ec9a517290d3.jpg?v=1785540999"},{"product_id":"pad5-6a-siemens-6a-addressable-power-supply-module-for-fire-alarm-systems","title":"PAD5-6A | Siemens 6A Addressable Power Supply Module for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens PAD5-6A is an addressable power-supply module designed for use with Siemens fire alarm control panels (FACPs). This unit provides up to 6 amps of 24 VDC NAC power and auxiliary output for powering notification appliances and system peripherals. The PAD5-6A ensures reliable, supervised power distribution and compliance with UL and ADA standards for life-safety applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePAD5-6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 6A total (four Class B or two Class A circuits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 3A (included in total output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Power Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 50\/60 Hz, 3A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFollower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne supervised NAC follower, 16–33 VDC or dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A and Class B, expandable with PAD-5-CLSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charging Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 7–18 Ah internal (up to 100 Ah with external enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNACs, ground fault, AC fail, and battery supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrouble Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForm C (general trouble) and Form A (AC fail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronization Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Sensor, Wheelock, Gentex, AMSECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Patterns\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI Temporal 3 \u0026amp; 4, March-time 30\/60\/120 PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-based with Flash firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL864 10th Edition, UL1076, UL2017, UL2572, ULC-S527, ULC-S576\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2HU enclosure (multi-module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 × 20 × 10 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003ePAD5-6A\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PAD5-6A is a UL 10th Edition and ULC-S527 listed addressable power-supply unit from Siemens’ advanced PAD-5 series. It is built to deliver dependable 24 VDC output for notification appliances and auxiliary devices, supporting both Class A and Class B circuits. The module seamlessly integrates with Siemens FP2011-U1 and FP2012-U1 fire alarm control panels, automatically communicating status and diagnostics for system monitoring. Featuring microprocessor-based control, battery supervision, and ground-fault detection, the PAD5-6A provides robust and compliant operation for commercial and industrial fire-protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Output Power: Provides up to 6A of 24VDC NAC and auxiliary power for connected devices.\u003c\/li\u003e\n\u003cli\u003eCircuit Flexibility: Supports four Class B or two Class A output circuits, expandable with optional PAD-5-CLSA module.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: Monitors battery, ground faults, and NAC integrity for continuous reliability.\u003c\/li\u003e\n\u003cli\u003eAdvanced Synchronization: Built-in support for System Sensor, Wheelock, Gentex, and AMSECO strobes and coded signals.\u003c\/li\u003e\n\u003cli\u003eExpandable Configuration: Optional modules allow additional circuits and releasing functions (e.g., deluge, pre-action).\u003c\/li\u003e\n\u003cli\u003eMicroprocessor Control: Flash memory-based firmware ensures fast, accurate diagnostics and easy upgrades.\u003c\/li\u003e\n\u003cli\u003eComprehensive Compliance: Meets UL864 10th Edition, ADA, ULC-S527, and ULC-S576 standards.\u003c\/li\u003e\n\u003cli\u003eMulti-Module Mounting: Fits 2HU enclosures with clean integration into Siemens fire systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD5-6A delivers the reliability and precision required for fire alarm power distribution and notification control in critical safety environments.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105135337728,"sku":"PAD5-6A","price":1977.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/167240_436x500_058dbc1f-cf6d-41c5-a8da-ce4027883c05.png?v=1785541003"},{"product_id":"fp2011-u1-siemens-regulated-170w-power-supply-26vdc-output-for-fire-alarm-systems","title":"FP2011-U1 | Siemens Regulated 170W Power Supply 26VDC Output for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens FP2011-U1 Power Supply is a regulated 170-watt unit designed to deliver stable 26 VDC output for fire alarm and life safety systems. It operates from 120\/220 VAC input and provides up to 6.5 amps of continuous current with minimal ripple voltage, ensuring reliable system performance and power integrity.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eFP2011-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eRegulated Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e120\/220 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e2 A Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e26 VDC Regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e6.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e170 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eRipple Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e0.1 VRMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eRegulation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eFully Regulated DC Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eHigh Efficiency Linear Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eConvection-Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eOverload and Short-Circuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eFire Alarm and Life Safety Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003ePanel or Chassis Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003eUL Listed Fire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e7.75 × 3.88 × 1.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4264%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4405%;\"\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eFP2011-U1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FP2011-U1 is a Siemens regulated power supply unit engineered for consistent 26 VDC output in fire alarm, security, and emergency communication systems. With an input range of 120 or 220 VAC at 50\/60 Hz, it delivers up to 6.5 amps of power output, suitable for driving notification appliances, control circuits, and auxiliary devices. Its low ripple voltage of 0.1 VRMS ensures clean and stable power, protecting sensitive electronics from noise or voltage fluctuations. Designed with overload protection and high electrical efficiency, the FP2011-U1 provides dependable long-term operation in demanding environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRegulated 26VDC Output: Provides stable voltage for reliable operation of connected fire alarm and control equipment.\u003c\/li\u003e\n\u003cli\u003eHigh Power Capacity: Supplies up to 170 watts (6.5 amps) to meet system load requirements.\u003c\/li\u003e\n\u003cli\u003eDual Input Compatibility: Operates on 120 or 220 VAC input for flexible installation across regions.\u003c\/li\u003e\n\u003cli\u003eLow Ripple Voltage: Ensures clean DC output with only 0.1 VRMS ripple, reducing signal interference.\u003c\/li\u003e\n\u003cli\u003eIntegrated Protection Features: Includes overload and short-circuit protection for safe, continuous use.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Measures only 7.75 × 3.88 × 1.75 inches, ideal for mounting in control cabinets.\u003c\/li\u003e\n\u003cli\u003eEnergy Efficient: Maintains high performance with low heat output through convection cooling.\u003c\/li\u003e\n\u003cli\u003eUL Listed Reliability: Certified for use in fire alarm and life safety system applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FP2011-U1 delivers the reliability and precision required for consistent, high-quality power distribution in Siemens fire alarm and life safety systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105144938752,"sku":"FP2011-U1","price":308.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FP2011-U1.jpg?v=1785541243"},{"product_id":"pad-4-6a-siemens-complete-6a-nac-power-expander-and-battery-charger-kit","title":"PAD-4-6A | Siemens Complete 6A NAC Power Expander and Battery Charger Kit","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens PAD-4-6A Complete Kit provides 6 amps of regulated 24 VDC power for fire alarm notification appliances and auxiliary loads. It includes the PAD-4 main board, power supply, and enclosure, functioning as a fully integrated NAC expander and battery charger for Siemens fire alarm systems.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 431.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003ePAD-4-6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eNAC Power Expander and Battery Charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eDistributed Power Supply Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003e24 VDC at 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eCircuit Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eFour Class B or Two Class A Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003e24 VDC, 3 A (counts toward 6 A total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eControl Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eTwo Supervised Triggers (16–33 VDC or Dry Contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003e120 VAC, 50\/60 Hz, 3 A Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 39.2px;\"\u003e\u003cstrong\u003eSynchronization Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 39.2px;\"\u003eSystem Sensor, Wheelock, Gentex, AMSECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eCoding Patterns\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eANSI Temporal 3 \u0026amp; 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eOnboard, Supports up to 18 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eTwo 7 Ah or Two 18 Ah Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eTrouble Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eForm C General-Trouble and Form A AC-Fail Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eLED Status for Output and Fault Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eWall-Mount Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eSiemens Fire Safety Fire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003eUL Listed, ADA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.8915%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9753%; height: 19.6px;\"\u003e16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003ePAD-4-6A\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PAD-4-6A is a complete 6-amp power distribution and notification appliance circuit (NAC) expansion kit designed for Siemens fire alarm systems. It includes the PAD-4 main board, a 170-watt power supply, and an enclosure, offering a ready-to-install solution for system expansion. This unit provides regulated 24 VDC power with four Class B or two Class A outputs and features built-in strobe synchronization supporting major manufacturers, including System Sensor, Wheelock, Gentex, and AMSECO. The integrated charger supports up to two 18 Ah batteries for backup operation, while dual trouble relays and LED indicators enhance supervision and maintenance visibility. The PAD-4-6A extends system capacity for audible and visual signaling in compliance with ADA and NFPA standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 6A Power Kit: Ships with PAD-4 main board, 170W power supply, and enclosure for immediate installation.\u003c\/li\u003e\n\u003cli\u003eMultiple Output Circuits: Provides four Class B or two Class A NAC outputs for flexible system design.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Power Capability: Includes a 24 VDC, 3A auxiliary output for external system components.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Battery Charger: Supports up to two 18 Ah batteries for reliable standby power.\u003c\/li\u003e\n\u003cli\u003eWide Sync Compatibility: Integrates with System Sensor, Wheelock, Gentex, and AMSECO synchronization protocols.\u003c\/li\u003e\n\u003cli\u003eDual Trouble Relays: Features general trouble and AC-failure contacts for enhanced monitoring.\u003c\/li\u003e\n\u003cli\u003eStrobe Sync and Coding Options: Includes ANSI Temporal 3 and 4 tone patterns for compliant signaling.\u003c\/li\u003e\n\u003cli\u003eLED Status Indicators: Provide immediate visual feedback for output, charging, and fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD-4-6A delivers the reliability and precision required for expanding power capacity and maintaining consistent, supervised operation in Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105145037056,"sku":"PAD-4-6A","price":1527.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PAD-4-6A.jpg?v=1785541246"},{"product_id":"sxl-xmain-siemens-sxl-x-fire-alarm-control-panel-main-board-assembly","title":"SXL-XMAIN | Siemens SXL-X Fire Alarm Control Panel Main Board Assembly","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens SXL-XMAIN Fire Alarm Control Panel Board is a microprocessor-based main circuit assembly designed for the SXL-X series. It provides four conventional initiating zones (expandable to eight) with field programmability, power-limited circuits, and advanced supervision features for small to mid-sized fire alarm installations.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 431.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSXL-XMAIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eMain Control Board Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSXL-X Conventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCircuit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eMicroprocessor-Based Control PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eZones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003e4 Style B (Class B) Zones, Expandable to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSiemens SXL-X Series FACPs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 39.2px;\"\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 39.2px;\"\u003eIonization, Photoelectric, and Photo-Thermal Detectors; MS Series Manual Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 39.2px;\"\u003e\u003cstrong\u003ePower-Limited Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 39.2px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eField Programmable with Onboard Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eDynamic Zone and Circuit Supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eAnnunciation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eRemote Annunciator Compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eTesting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eOne-Person Walk Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSmall to Mid-Size Commercial and Residential Buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eAuxiliary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eRemote Bell Power Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eADA Signaling and UL Fire Alarm Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003e16 × 13 × 4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSXL-XMAIN\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SXL-XMAIN serves as the primary printed circuit board (PCB) assembly for Siemens SXL-X Fire Alarm Control Panels. It manages the detection and notification operations of up to four conventional initiating zones, which can be expanded to eight using optional modules. Designed with a power-limited configuration, the board supports multiple Siemens detection devices, including ionization, photoelectric, and photo-thermal sensors. Its microprocessor-based design enables field programmability, efficient supervision, and compatibility with remote annunciation systems. The SXL-XMAIN provides dependable fire detection control for small commercial buildings, hotels, and office complexes requiring a compact yet feature-rich fire alarm solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor-Based Control: Provides precise monitoring and processing of input and output signals across all zones.\u003c\/li\u003e\n\u003cli\u003eExpandable Zone Capacity: Supports four Class B zones, expandable to eight for greater system flexibility.\u003c\/li\u003e\n\u003cli\u003eWide Device Compatibility: Works with Siemens ionization, photoelectric, and thermal detectors, as well as MS manual stations.\u003c\/li\u003e\n\u003cli\u003eField Programmable Interface: Allows quick setup and customization of detection parameters without specialized tools.\u003c\/li\u003e\n\u003cli\u003ePower-Limited Design: Ensures compliance with modern safety and electrical isolation standards.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Testing Functions: One-person test mode simplifies inspection and verification procedures.\u003c\/li\u003e\n\u003cli\u003eRemote Annunciation Support: Compatible with external annunciators for enhanced status visibility.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Bell Power Output: Can supply additional bell power for integration into larger systems like the MXL FACP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SXL-XMAIN delivers the reliability and precision required for dependable fire detection and supervision in compact and expandable Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105145069824,"sku":"SXL-XMAIN","price":2644.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_fe3b43e0-f180-46f9-b1fc-01fea06f69cd.webp?v=1785541247"},{"product_id":"pad-3-siemens-fire-alarm-power-extender-with-6a-24vdc-output","title":"PAD-3 | Siemens Fire Alarm Power Extender with 6A 24VDC Output","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"396\"\u003eThe Siemens PAD-3 is a notification appliance circuit expander with integrated auxiliary power, designed for use with Siemens fire alarm control panels. It delivers 6 amps of regulated 24VDC power that can be distributed across four independent Notification Appliance Circuits (NACs). This unit ensures reliable operation of fire safety notification devices in compliance with building and accessibility requirements.\u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePAD-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Extender Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24VDC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 circuits, each rated at 3A (power-limited)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 inputs to control 4 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteady, ANSI temporal, or synchronized strobe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHorn\/Strobe Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports horn silence while strobes remain active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens 24VDC fire notification appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADA-compliant for audible and visual notification requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAppliance Extender, Power Extender Panel, Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 × 14 × 6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003ePAD-3\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PAD-3 is a Siemens power extender module engineered for expanding fire alarm system capacity in commercial and institutional facilities. Each of its four NAC outputs is power-limited and rated at 3 amps, with flexible input control that supports steady, ANSI temporal, or synchronized strobe output modes. It is fully compatible with Siemens 24VDC notification appliances, including horn\/strobes, horns, and strobes. Designed with ADA compliance in mind, the PAD-3 ensures sufficient power delivery for buildings requiring enhanced audible and visual notification coverage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Output Power: Provides up to 6A of 24VDC regulated power.\u003c\/li\u003e\n\u003cli\u003eFour NAC Outputs: Each circuit rated at 3A and power-limited for safety.\u003c\/li\u003e\n\u003cli\u003eFlexible Control Inputs: Supports one or two inputs to control all outputs.\u003c\/li\u003e\n\u003cli\u003eMultiple Operating Modes: Can be configured for steady, ANSI temporal, or synchronized strobe outputs.\u003c\/li\u003e\n\u003cli\u003eHorn\/Strobe Silence Function: Allows silencing of horns while maintaining strobe operation using a single wiring set.\u003c\/li\u003e\n\u003cli\u003eCompatibility: Works with all Siemens Fire Safety 24VDC notification appliances.\u003c\/li\u003e\n\u003cli\u003eADA Compliance: Supplies extra notification power to meet accessibility standards.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Designed for integration with Siemens fire alarm systems in commercial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD-3 delivers the reliability and flexibility required for expanding notification appliance circuits in modern fire protection systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105159815424,"sku":"PAD-3","price":962.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PAD-3.jpg?v=1785541598"},{"product_id":"siemens-cp-35-system-3-fire-alarm-control-module-500-884879","title":"Siemens CP-35 System 3 Fire Alarm Control Module (500-884879)","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"396\"\u003eThe Siemens CP-35 (500-884879) is the primary control module for the System 3 universal alarm control platform. Designed with solid-state circuitry, this unit provides reliable fire alarm monitoring and control for commercial, institutional, and industrial facilities. The CP-35 ensures dependable system operation while meeting recognized safety standards.\u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternate Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500-884879\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuitry Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-State\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFPA 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial, institutional, industrial, and life safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary control unit for System 3 fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed for waterflow alarm with supplementary modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEA (Each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eCP-35\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe CP-35 is the core controller for Siemens’ System 3 alarm series, engineered to handle a variety of life safety applications. Built with durable solid-state electronics, it maintains consistent performance in demanding environments. The unit is UL listed and FM approved, ensuring compliance with NFPA 72 fire safety requirements. Its functionality can be expanded with supplementary modules, including UL-listed waterflow alarm capability, providing versatility for different system configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCore Control Module: Serves as the main controller for System 3 fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eSolid-State Electronics: Provides durable and stable performance in long-term applications.\u003c\/li\u003e\n\u003cli\u003eNFPA 72 Compliance: Meets recognized standards for fire alarm and life safety installations.\u003c\/li\u003e\n\u003cli\u003eUL and FM Approved: Certified for reliable operation and regulatory compliance.\u003c\/li\u003e\n\u003cli\u003eWaterflow Alarm Support: UL listed for waterflow monitoring when used with supplementary modules.\u003c\/li\u003e\n\u003cli\u003eWide Application Range: Suitable for commercial, institutional, and industrial safety systems.\u003c\/li\u003e\n\u003cli\u003eExpandable System Integration: Supports modular upgrades for added functions and flexibility.\u003c\/li\u003e\n\u003cli\u003eDiscontinued Model: Available as surplus for maintaining existing System 3 installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CP-35 delivers the reliability and precision required for life safety alarm monitoring and system control.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105160012032,"sku":"CP-35","price":6359.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/CP-35.jpg?v=1785541603"},{"product_id":"xls-250-zic4a-ep-siemens-fire-alarm-system-assembly-with-dlc-pmi-3-zic-4a-cc-5-psc-12","title":"XLS-250-ZIC4A-EP | Siemens Fire Alarm System Assembly with DLC, PMI-3, ZIC-4A, CC-5, PSC-12","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"168\"\u003eThe Siemens XLS-250-ZIC4A-EP is a complete fire alarm system package designed for reliable detection, monitoring, and control. It includes core system modules such as the DLC, PMI-3, ZIC-4A, CC-5, and PSC-12, ensuring comprehensive coverage and flexibility for large-scale fire safety applications. Built for performance and durability, the XLS-250-ZIC4A-EP supports advanced integration within Siemens XLS fire alarm platforms.\u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLS-250-ZIC4A-EP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Panels \u0026amp; Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(1) DLC, (1) PMI-3, (1) ZIC-4A, (1) CC-5, (1) PSC-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLS Series Fire Alarm Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSC-12 integrated module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePMI-3 for system communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDLC digital loop controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZIC-4A zone interface card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-5 card cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 × 7 × 10 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e178 × 178 × 254 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lbs (7.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About XLS-250-ZIC4A-EP\u003c\/h4\u003e\n\u003cp\u003eThe XLS-250-ZIC4A-EP is part of the Siemens XLS Series, a modular and expandable fire alarm system engineered for medium to large facilities. This assembly includes essential components such as a Digital Loop Controller (DLC), Power Module Interface (PMI-3), Zone Interface Card (ZIC-4A), CC-5 card cage, and PSC-12 power supply. Its modular design provides scalability and adaptability for customized fire protection solutions. With Siemens’ proven technology, the unit ensures system redundancy, robust communication, and streamlined integration across a wide range of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete System Package: Includes DLC, PMI-3, ZIC-4A, CC-5, and PSC-12 modules.\u003c\/li\u003e\n\u003cli\u003eScalable Design: Supports expansion for medium to large fire safety systems.\u003c\/li\u003e\n\u003cli\u003eReliable Power Supply: Integrated PSC-12 ensures stable operation and system resilience.\u003c\/li\u003e\n\u003cli\u003eAdvanced Zone Interface: ZIC-4A card provides flexible zone management.\u003c\/li\u003e\n\u003cli\u003eDigital Loop Controller: DLC supports high-speed data communication and device monitoring.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Engineered for long-term performance in demanding environments.\u003c\/li\u003e\n\u003cli\u003eCompatibility: Designed for Siemens XLS fire alarm platforms.\u003c\/li\u003e\n\u003cli\u003eActive Production Status: Ensures availability for current and future projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XLS-250-ZIC4A-EP delivers the reliability and scalability required for comprehensive fire alarm system operation.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105162240256,"sku":"XLS-250-ZIC4A-EP","price":18226.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/XLS-250-ZIC4A-EP.jpg?v=1785541667"},{"product_id":"id-60ib-siemens-conventional-smoke-detector-48-vac","title":"ID-60IB | Siemens Conventional Smoke Detector 4.8 VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"168\"\u003eThe Siemens ID-60IB is a conventional smoke detector designed for use in Siemens fire alarm systems. Operating at 4.8 VAC, it provides reliable smoke detection for life safety applications.\u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 333.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eID60IB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eSmoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eConventional smoke detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003e4.8 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eDetects smoke particles and activates alarm conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eSiemens conventional fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eFire detection in commercial and institutional facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eMonitors circuit wiring integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eIndoor fire alarm installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eStandard Siemens detector size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5848%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1959%;\"\u003e0.5 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About ID-60IB\u003c\/h4\u003e\n\u003cp\u003eThe ID60IB is part of Siemens’ line of conventional detection devices, built to provide dependable fire protection in commercial and institutional environments. It uses standard smoke detection technology to sense combustion particles and activate alarm conditions. Designed for compatibility with Siemens control equipment, the detector integrates into existing installations for supervised fire protection. This model has been discontinued by the manufacturer, with system operators typically migrating to newer Siemens detection platforms for replacements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConventional Detection: Provides standard smoke detection functionality.\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: Functions at 4.8 VAC supply.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for Siemens fire alarm control equipment.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: Monitors circuit integrity to ensure reliability.\u003c\/li\u003e\n\u003cli\u003eLegacy Device: Supports existing installations requiring ID-60IB units.\u003c\/li\u003e\n\u003cli\u003eCommercial Applications: Suitable for institutional and industrial fire protection.\u003c\/li\u003e\n\u003cli\u003eDiscontinued Model: No longer manufactured; replacement options may be required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ID60IB delivers the reliability and precision required for conventional fire detection, though it is discontinued and supported only in legacy systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105163878656,"sku":"ID-60IB","price":804.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/15c0318f0b174551ba7be047c3969959.jpg?v=1785541712"},{"product_id":"mxl-iq-siemens-intelligent-fire-alarm-control-panel-for-mid-sized-applications","title":"MXL-IQ | Siemens Intelligent Fire Alarm Control Panel for Mid-Sized Applications","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"168\"\u003eThe Siemens MXL-IQ is a compact intelligent fire alarm control panel designed for small to mid-sized building applications. It integrates detection, notification, and system management functions in a single enclosure for reliable life safety operation.\u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 333.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eMXL-IQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eControl Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eMXL Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eIntelligent fire alarm control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eDevice Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eSiemens addressable and conventional devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eDetection, notification, supervisory, and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eNetwork-capable for system integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eExpansion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eModular cards and interface modules supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eSmall to mid-sized commercial and institutional facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eCompact wall-mounted cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eLife safety and fire alarm system installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eUL listed (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eStandard Siemens panel sizing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e28 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About MXL-IQ\u003c\/h4\u003e\n\u003cp\u003eThe MXL-IQ is part of Siemens’ MXL series of intelligent fire alarm systems, engineered to deliver scalable protection with modular flexibility. This panel supports both addressable and conventional devices, providing adaptability for a range of system designs. It integrates advanced detection, alarm, and supervisory features with network communication capabilities for seamless integration across facilities. Compact yet powerful, the MXL-IQ provides centralized monitoring and control, making it suitable for commercial, institutional, and industrial environments requiring reliable fire protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Panel: Combines detection, notification, and system management in one enclosure.\u003c\/li\u003e\n\u003cli\u003eIntelligent System: Supports Siemens addressable devices for precise fire detection.\u003c\/li\u003e\n\u003cli\u003eHybrid Capability: Compatible with both addressable and conventional devices.\u003c\/li\u003e\n\u003cli\u003eNetwork Ready: Provides communication for integration into larger Siemens networks.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Space-efficient enclosure for small to mid-sized facilities.\u003c\/li\u003e\n\u003cli\u003eScalable Architecture: Supports modular expansion as system needs grow.\u003c\/li\u003e\n\u003cli\u003eCommercial Applications: Suitable for offices, schools, and industrial sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MXL-IQ delivers the reliability and precision required for intelligent fire alarm control in scalable life safety applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105163911424,"sku":"MXL-IQ","price":1108.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_0d5687f4-1c94-4341-8cea-2752c6920ae5.webp?v=1785541713"},{"product_id":"zic-4a-siemens-zone-card-with-4-supervised-initiating-circuits-for-fire-alarm-panels","title":"ZIC-4A | Siemens Zone Card with 4 Supervised Initiating Circuits for Fire Alarm Panels","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"396\"\u003eThe Siemens ZIC-4A is a fire alarm control panel zone card designed to provide four conventional initiating device circuits. It expands the input capacity of compatible Siemens fire alarm systems for supervised zone monitoring.\u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 333.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eZIC-4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eZone Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eFire alarm initiating device circuit card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eAdds conventional supervised input zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eSiemens fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eDetectors, pull stations, and initiating devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eMonitors for open, short, and alarm conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003ePlug-in modular card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eFire alarm zone expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eCommercial, institutional, and industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eUL listed (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003eStandard Siemens module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.1386%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.1848%; height: 19.5938px;\"\u003e1 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About ZIC-4A\u003c\/h4\u003e\n\u003cp\u003eThe ZIC-4A is part of Siemens’ modular fire alarm system components, developed to add supervised initiating device circuits (IDCs) to control panels. Each card provides four additional conventional zones for connecting detectors, pull stations, and other initiating devices. It ensures proper circuit supervision for open and short conditions, maintaining system integrity and code compliance. Designed for use in Siemens fire alarm panels, the ZIC-4A supports scalable system configurations in commercial, institutional, and industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour IDC Circuits: Expands system input with four supervised initiating device circuits.\u003c\/li\u003e\n\u003cli\u003eZone Monitoring: Connects smoke detectors, heat detectors, and manual pull stations.\u003c\/li\u003e\n\u003cli\u003eSupervised Inputs: Detects open, short, and alarm conditions for system integrity.\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Designed for Siemens fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eModular Expansion: Field-installable for scalable configurations.\u003c\/li\u003e\n\u003cli\u003eCommercial Use: Suitable for large-scale building fire alarm installations.\u003c\/li\u003e\n\u003cli\u003eReliable Operation: Ensures dependable zone monitoring in critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ZIC-4A delivers the reliability and precision required for supervised zone expansion in Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105166598400,"sku":"ZIC-4A","price":2203.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ZIC-4A.jpg?v=1785541716"},{"product_id":"s54431-b4-a1-siemens-mxl-line-card-for-fire-alarm-system-expansion","title":"S54431-B4-A1 | Siemens MXL Line Card for Fire Alarm System Expansion","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"168\"\u003eThe Siemens S54431-B4-A1 is a fire alarm MXL line card designed for use with Siemens MXL fire alarm control panels. It provides communication and expansion capability for system devices and circuits within the MXL platform.\u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS54431-B4-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMXL fire alarm system card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExpands signaling line circuits (SLCs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens MXL fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable detectors, modules, notification appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModular card, field-installable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm system expansion and communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial, institutional, and industrial facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Siemens MXL card size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About S54431-B4-A1\u003c\/h4\u003e\n\u003cp\u003eThe S54431-B4-A1 is part of Siemens’ MXL series fire alarm components, engineered to support system integration and device communication. Installed as a modular line card, it expands panel functionality by providing additional signaling line circuits (SLCs) for intelligent device connectivity. This card enables addressable detectors, modules, and notification appliances to interface with the MXL control panel. Built for reliability and ease of integration, the S54431-B4-A1 supports commercial and industrial fire alarm applications that require scalable and code-compliant system expansion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMXL Line Card: Designed specifically for Siemens MXL fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eSystem Expansion: Provides additional signaling line circuits (SLCs) for device connectivity.\u003c\/li\u003e\n\u003cli\u003eDevice Compatibility: Supports addressable detectors, modules, and notification appliances.\u003c\/li\u003e\n\u003cli\u003eReliable Communication: Ensures stable data exchange between devices and control panel.\u003c\/li\u003e\n\u003cli\u003eModular Design: Field-installable card for scalable fire alarm system growth.\u003c\/li\u003e\n\u003cli\u003eCommercial Use: Suitable for large-scale commercial and industrial facilities.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets fire alarm system compliance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe S54431-B4-A1 delivers the reliability and precision required for scalable MXL fire alarm system operation.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105166663936,"sku":"S54431-B4-A1","price":1781.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l960_51cd4071-b653-4097-a6ae-29a2bf437934.webp?v=1785541717"},{"product_id":"ft2015-u3-siemens-remote-terminal-key-for-fire-alarm-systems","title":"FT2015-U3 | Siemens Remote Terminal Key for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"396\"\u003eThe Siemens FT2015-U3 is a remote terminal key designed for use with Siemens fire alarm systems. It provides secure access and operator interaction with remote terminal units for monitoring and control.\u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFT2015-U3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKey Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote terminal key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides secure access to Siemens RTUs and annunciators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens remote terminal units and annunciators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm system monitoring and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDurable metal\/plastic composite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLimits access to trained personnel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial and industrial fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Siemens key size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About FT2015-U3\u003c\/h4\u003e\n\u003cp\u003eThe FT2015-U3 is part of Siemens’ line of fire alarm system accessories, developed to ensure controlled access to remote terminal units (RTUs). This key is specifically manufactured for Siemens annunciators and operator interfaces, allowing authorized personnel to perform system operations such as viewing alarms, supervisory events, and system status. It is built with durable construction to withstand repeated use in commercial and industrial environments. The FT2015-U3 enhances system security by limiting access to trained personnel, ensuring code-compliant fire alarm management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccess Control: Provides authorized access to Siemens remote terminal units.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for use with Siemens fire alarm RTUs and annunciators.\u003c\/li\u003e\n\u003cli\u003eOperator Functions: Enables key-secured system monitoring and control operations.\u003c\/li\u003e\n\u003cli\u003eDurable Design: Built for long-term, repeated use in commercial applications.\u003c\/li\u003e\n\u003cli\u003eEnhanced Security: Restricts access to trained and authorized personnel.\u003c\/li\u003e\n\u003cli\u003eEssential Accessory: Required for operating Siemens remote terminal interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FT2015-U3 delivers the reliability and precision required for secure fire alarm system access and remote terminal operation.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105166762240,"sku":"FT2015-U3","price":1365.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FT2015-U3.jpg?v=1785541721"},{"product_id":"vci2001-u1-siemens-50w-card-amplifier-for-fire-alarm-emergency-voice-systems","title":"VCI2001-U1 | Siemens 50W Card Amplifier for Fire Alarm \u0026 Emergency Voice Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens VCI2001-U1 is a 50-watt card amplifier designed for use in Siemens fire alarm and emergency communication systems. It provides reliable voice amplification for paging, alarms, and mass notification applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 294px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eVCI2001-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eAmplifier Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eVoice card amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eVoice paging, alarm, and notification audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eSiemens emergency communication systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eModular card installation in system enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003ePlug-in expansion card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003ePaging, alarms, mass notification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eCommercial, institutional, and industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eUL listed (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003eStandard Siemens card size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6049%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.0804%;\"\u003e3 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About VCI2001-U1\u003c\/h4\u003e\n\u003cp\u003eThe VCI2001-U1 is part of Siemens’ modular voice communication components, developed for integration into fire alarm and emergency audio systems. Installed as a card amplifier, it delivers 50 watts of output power for distributing voice signals across connected speakers and notification appliances. Its compact card form factor allows seamless installation in compatible Siemens enclosures, supporting both single and distributed audio system designs. Built for commercial and institutional environments, the VCI2001-U1 ensures clear, intelligible voice communication in critical life safety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e50-Watt Output: Provides strong and consistent audio amplification for notification appliances.\u003c\/li\u003e\n\u003cli\u003eCard-Based Module: Compact card amplifier for installation in compatible Siemens systems.\u003c\/li\u003e\n\u003cli\u003eVoice Communication Support: Distributes paging, alarms, and emergency voice signals.\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Designed for Siemens fire alarm and emergency communication systems.\u003c\/li\u003e\n\u003cli\u003eReliable Operation: Built for mission-critical life safety environments.\u003c\/li\u003e\n\u003cli\u003eCommercial Applications: Suitable for schools, hospitals, campuses, and industrial facilities.\u003c\/li\u003e\n\u003cli\u003eExpandable Design: Supports distributed and centralized audio architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe VCI2001-U1 delivers the reliability and precision required for emergency voice communication and life safety system applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105176461568,"sku":"VCI2001-U1","price":1509.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/84b2b1b29af44e38a95bc7aed0a38039.jpg?v=1785541904"},{"product_id":"pad-4-mb-siemens-replacement-board-for-pad-4-nac-expander-module","title":"PAD-4-MB | Siemens Replacement Board for PAD-4 NAC Expander Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens PAD-4-MB is a replacement main board for the PAD-4 NAC (Notification Appliance Circuit) expander module. It restores proper circuit expansion capability for Siemens fire alarm systems, ensuring reliable operation of notification devices.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 294px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003ePAD-4-MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eReplacement Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eNAC expander replacement PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eProvides notification appliance circuit expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eSiemens PAD-4 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eHorns, strobes, and signaling appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eField-replaceable inside PAD-4 enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eDirect-fit replacement main board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eFire alarm NAC expansion systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eReduces cost vs. full module replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003eCommercial and industrial fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.5074%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.3594%; height: 19.6px;\"\u003e1 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About PAD-4-MB\u003c\/h4\u003e\n\u003cp\u003eThe PAD-4-MB is part of Siemens’ replacement component offerings for the PAD-4 notification appliance expander. It is designed to provide full functionality as a direct replacement for the original main board in the module. The board supports the distribution of additional notification appliance circuits, allowing fire alarm systems to power and control horns, strobes, and other signaling devices. By replacing only the board, it offers a cost-effective solution for maintaining system integrity without replacing the full NAC expander assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect Replacement: Designed specifically for Siemens PAD-4 NAC expander modules.\u003c\/li\u003e\n\u003cli\u003eNotification Appliance Support: Maintains distribution of additional horns, strobes, and signaling devices.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Fully compatible with Siemens fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eCost-Effective Solution: Restores module functionality without replacing the full enclosure.\u003c\/li\u003e\n\u003cli\u003eReliable Performance: Provides the same operational capability as the original board.\u003c\/li\u003e\n\u003cli\u003eSimplified Maintenance: Designed for field replacement in existing systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD-4-MB delivers the reliability and precision required for maintaining Siemens fire alarm NAC expansion systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105176625408,"sku":"PAD-4-MB","price":799.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PR-F1P1-4165_450x450_5db62ec6-63b3-4a3b-b679-fd0cb5131c21.jpg?v=1785541910"},{"product_id":"dac-net-siemens-digital-audio-card-for-fire-alarm-and-emergency-communication-systems","title":"DAC-NET | Siemens Digital Audio Card for Fire Alarm and Emergency Communication Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens DAC-NET is a digital audio card designed for use in Siemens fire and life safety systems. It provides audio networking and distribution capabilities, enabling reliable communication across system components.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 333.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eDAC-NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eAudio Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eDigital audio interface card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eAudio networking and distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003ePaging, alarms, mass notification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eSiemens fire and emergency communication panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eModular card inside compatible enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003ePlug-in expansion card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eDigital audio processing and networking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eCommercial, industrial, and institutional environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eUL listed (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003eStandard Siemens card size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 20.8812%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9856%; height: 19.6px;\"\u003e2 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About DAC-NET\u003c\/h4\u003e\n\u003cp\u003eThe DAC-NET is part of Siemens’ modular fire alarm and emergency communication system accessories, developed to expand system audio capabilities. Installed within Siemens control panels, this digital audio card supports network-based audio transmission for paging, alarms, and mass notification. It is designed for compatibility with Siemens digital audio systems, ensuring seamless integration with other communication modules. By providing digital audio processing and networking functionality, the DAC-NET enhances system flexibility and scalability in commercial, industrial, and institutional applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Audio Processing: Provides network-based audio functionality for Siemens systems.\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Designed for use with Siemens fire alarm and emergency communication panels.\u003c\/li\u003e\n\u003cli\u003ePaging and Notification: Enables distribution of voice pages, tones, and emergency alerts.\u003c\/li\u003e\n\u003cli\u003eReliable Performance: Engineered for consistent audio delivery in critical environments.\u003c\/li\u003e\n\u003cli\u003eScalable Design: Supports system expansion and distributed communication networks.\u003c\/li\u003e\n\u003cli\u003eCommercial Applications: Ideal for schools, hospitals, campuses, and industrial facilities.\u003c\/li\u003e\n\u003cli\u003eModular Form Factor: Compact card design for installation inside compatible panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DAC-NET delivers the reliability and precision required for digital audio networking in Siemens fire and emergency communication systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105176690944,"sku":"DAC-NET","price":1947.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_2e249738-9f2a-48a6-835d-b2da75f83ae3.webp?v=1785541912"},{"product_id":"pbr-1191-siemens-conventional-linear-beam-smoke-detector-with-retroreflecting-prism","title":"PBR-1191 | Siemens Conventional Linear Beam Smoke Detector with Retroreflecting Prism","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens PBR-1191 is a conventional linear beam smoke detector with a retroreflecting prism designed to ensure reliable smoke detection in open and high-ceiling environments. Its prism structure reflects incident light beams back along their path, providing consistent performance in beam detection systems. The device connects to a 24V supply and incorporates a reflector heater for reliable operation in areas prone to condensation.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePBR-1191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConventional linear beam smoke detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRetroreflecting prism with isosceles orthogonal triangle faces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble reflection of beams back to source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIdentical to detector base for easy integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeater Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V supply connection for condensation control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge open areas, warehouses, atriums, industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigned to minimize effects of structural movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 × 7 × 6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 lbs (approx. 0.68 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003ePBR-1191\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PBR-1191 is part of Siemens’ fire safety product line and is specifically engineered for use with beam smoke detection systems. It features a prism reflector with lateral faces formed by isosceles orthogonal triangles, ensuring precise double reflection of incoming light beams. The reflector housing is identical to the detector base, allowing straightforward installation and system integration. With its built-in heater option, the PBR-1191 maintains accuracy and functionality even in challenging environments with high humidity or condensation risks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRetroreflecting prism design: Returns light beams back along their path for accurate smoke detection.\u003c\/li\u003e\n\u003cli\u003eIsosceles orthogonal structure: Double reflection ensures consistent optical performance.\u003c\/li\u003e\n\u003cli\u003eReflector housing: Built with the same base structure as the detector for simplified installation.\u003c\/li\u003e\n\u003cli\u003eHeater integration: Equipped with a 24V heater connection to prevent condensation interference.\u003c\/li\u003e\n\u003cli\u003eDurable construction: Designed to withstand structural vibration and movement.\u003c\/li\u003e\n\u003cli\u003eWide application use: Suitable for open areas, warehouses, and high-ceiling facilities.\u003c\/li\u003e\n\u003cli\u003eActive system support: Functions as a core component of Siemens beam smoke detection systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PBR-1191 delivers the reliability and precision required for effective beam smoke detection in demanding fire safety applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105177379072,"sku":"PBR-1191","price":1462.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PBR-1191.jpg?v=1785541933"},{"product_id":"icp-b6-siemens-intelligent-control-point-module-for-addressable-systems","title":"ICP-B6 | Siemens Intelligent Control Point Module for Addressable Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens ICP-B6 is an intelligent control point module designed for use with Siemens addressable fire alarm systems. It provides supervised output control for auxiliary equipment such as fans, dampers, and door holders in life-safety applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 352.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eFire \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eICP-B6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eControl Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eIntelligent Control Point Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eLow (panel-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eProvides Supervised Output Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eControls Fans, Dampers, Door Holders, Auxiliary Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eAddressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003ePanel or Field Electrical Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eWiring Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eOpen\/Short Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eCompact Module Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eStandard Module Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003eStandard Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6022%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2646%;\"\u003e0.4 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About ICP-B6\u003c\/h4\u003e\n\u003cp\u003eThe ICP-B6 is part of Siemens’ intelligent device family, built to expand control functions in addressable fire alarm systems. Operating on 24 VDC, it enables the fire alarm control panel to activate and monitor external devices during alarm or supervisory events. The module supports supervised wiring, ensuring faults such as opens or shorts are detected and reported to the system. Compact and panel- or field-mountable, the ICP-B6 integrates seamlessly with Siemens control equipment and is UL listed for fire protective signaling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntelligent Control Module: Provides supervised output control for external devices.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Works with Siemens addressable fire alarm systems.\u003c\/li\u003e\n\u003cli\u003e24 VDC Operation: Low-voltage power ensures safe, reliable operation.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Control: Activates fans, dampers, door holders, or other equipment.\u003c\/li\u003e\n\u003cli\u003eSupervised Wiring: Monitors output circuit integrity for faults.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits in panel enclosures or remote electrical boxes.\u003c\/li\u003e\n\u003cli\u003eCertified Compliance: UL listed for fire protective signaling use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ICP-B6 delivers the reliability and precision required for auxiliary equipment control in addressable fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105185046784,"sku":"ICP-B6","price":1255.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/SiemensICP-B6_540x_50493363-0861-4e7a-9711-34af90fcd36f.jpg?v=1785542086"},{"product_id":"500-648670-siemens-zone-indicating-card-module-for-fire-alarm-systems","title":"500-648670 | Siemens Zone-Indicating Card Module for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens 500-648670 is a zone-indicating card module designed for Siemens fire alarm systems. It provides supervised zone indication, allowing clear identification of alarm, supervisory, and trouble conditions in multi-zone installations.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 313.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eFire \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003e500-648670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eZone Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eZone-Indicating Card Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003ePanel-Supplied (Nominal 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eProvides Zone Status Indication and Supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eFire Alarm System Annunciation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eSiemens Fire Alarm Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eInternal Module Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003eStandard Module Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003ePCB\/Assembly Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003ePanel or Chassis Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.9627%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7226%; height: 19.6px;\"\u003e0.5 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 500-648670\u003c\/h4\u003e\n\u003cp\u003eThe 500-648670 is part of Siemens’ line of fire alarm system modules, built to expand zone monitoring and annunciation capabilities. This card integrates into compatible Siemens control equipment, offering dedicated indicators for each connected zone. Its supervised circuitry ensures reliability by continuously monitoring connections for open, short, or fault conditions. UL listed for life-safety applications, the 500-648670 supports both new and legacy Siemens systems requiring modular expansion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZone Indication Module: Provides visual status for fire alarm system zones.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: Monitors for open, short, and trouble conditions.\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Designed for use with compatible Siemens fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eClear Annunciation: Displays alarm, supervisory, and fault conditions.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Certified for fire alarm and life-safety applications.\u003c\/li\u003e\n\u003cli\u003eReliable Performance: Ensures dependable monitoring in supervised networks.\u003c\/li\u003e\n\u003cli\u003eModular Design: Fits into Siemens fire alarm panels and assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 500-648670 delivers the reliability and precision required for zone annunciation in Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105185177856,"sku":"500-648670","price":1372.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Siemens-ZIC-8B-500-648670-FF-XLS-XLSV-Zone-Indicating-Card-Module_c9eb8bbb-5eb8-4197-b690-6489604d1a3c_1.1e2e6b397af3cb1f656cf8649e6b9277.jpg?v=1785542089"},{"product_id":"msi-20b-siemens-dual-action-intelligent-addressable-fire-alarm-pull-station","title":"MSI-20B | Siemens Dual-Action Intelligent Addressable Fire Alarm Pull Station","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens MSI-20B is a dual-action, intelligent addressable manual fire alarm pull station designed for use with Siemens MXL, IXL\/ICON-1, and XL3 control panels. Built with a durable red polycarbonate housing and white raised lettering, the MSI-20B provides reliable manual fire alarm initiation with clear status indication. The pull-down lever locks in place when activated and requires reset with an Allen key, ensuring security and reliability.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSI-20B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Fire Alarm Pull Station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStyle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-Action, Addressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed with white lettering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLever locks until reset with Allen key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMXL, XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPU or FPI-32 Programmer\/Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface or semi-flush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.50 × 4.00 × 3.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew (also available reconditioned with 1-year warranty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEA (Each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed; USCG, FM, CSFM, NYC FD Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eMSI-20B\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe MSI-20B from Siemens Industry, Inc. is engineered for dual-action operation, requiring users to lift and pull for activation, reducing the chance of accidental alarms. It incorporates advanced microcomputer-chip technology for dependable communication with Siemens intelligent fire alarm control panels. The device supports electronic address programming via the DPU or FPI-32 Programmer\/Tester, providing dynamic supervision and enhanced system reliability. Designed for either surface or semi-flush mounting, the MSI-20B is UL Listed and approved by multiple safety authorities, making it suitable for a wide range of fire protection applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual-action operation: Lift cover and pull down lever to activate.\u003c\/li\u003e\n\u003cli\u003eDurable polycarbonate housing: Matte-finished red with raised white lettering.\u003c\/li\u003e\n\u003cli\u003eClear status indication: Pull-down lever remains locked until reset.\u003c\/li\u003e\n\u003cli\u003eReset mechanism: Hinged cover opened and closed with Allen key.\u003c\/li\u003e\n\u003cli\u003eProgrammable: Compatible with DPU or FPI-32 Programmer\/Tester.\u003c\/li\u003e\n\u003cli\u003eAdvanced communication: Microcomputer-chip technology with dynamic supervision.\u003c\/li\u003e\n\u003cli\u003eMounting options: Supports surface or semi-flush installation.\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed; approved by USCG, FM, CSFM, and NYC Fire Department.\u003c\/li\u003e\n\u003cli\u003eCompatibility: Siemens MXL, IXL\/ICON-1, XL3, and XLS fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eConstruction: Shock- and vibration-resistant design for durability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105186193664,"sku":"MSI-20B","price":1653.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/file_6_26.jpg?v=1785542120"},{"product_id":"aa-30u-siemens-alarm-extender-module-for-system-3-fire-alarm-panels","title":"AA-30U | Siemens Alarm Extender Module for System 3 Fire Alarm Panels","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens AA-30U Alarm Extender Module is designed for use with the System 3 fire alarm control panel. It provides a four-wire circuit for operating polarized, parallel-connected 24 VDC notification appliance circuits. Supporting bells, horns, and strobes, it ensures reliable Class A circuit extension in fire safety systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAA-30U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm Extender Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens System 3 FACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour-wire, polarized NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 bells or 10 horns\/strobes (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFPA 72 ‘Class A’ (‘Style Z’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEA (Each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003eAA-30U\u003c\/h4\u003e\n\u003cp\u003eThe AA-30U is part of Siemens’ fire safety accessory line and is intended for integration with the System 3 control panel. It offers compliance with NFPA 72 ‘Class A’ requirements, supporting notification appliances in both bell and horn\/strobe configurations. The unit can handle a circuit load up to 1.5 Amps, allowing flexible expansion based on connected device current ratings. Although discontinued by the manufacturer, the AA-30U remains a dependable solution for maintaining or expanding legacy Siemens System 3 installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass A Circuit Extension: Meets NFPA 72 ‘Class A’ (‘Style Z’) requirements.\u003c\/li\u003e\n\u003cli\u003eNotification Appliance Support: Operates polarized, parallel-connected 24 VDC bells, horns, and strobes.\u003c\/li\u003e\n\u003cli\u003eLoad Capacity: Supports up to 20 bells or 10 horns\/strobes within 1.5 Amp total.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for Siemens System 3 fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Lightweight module for easy integration.\u003c\/li\u003e\n\u003cli\u003eLegacy Use: Maintains functionality for existing System 3 installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AA-30U delivers the reliability and precision required for extending notification appliance circuits in Siemens System 3 fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105186423040,"sku":"AA-30U","price":1865.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/145359_478x640_bb9f9d35-60b1-4994-bfa7-226f5c920af0.jpg?v=1785542127"},{"product_id":"fc901-u3-siemens-50-point-addressable-fire-alarm-control-panel-with-170w-power-supply","title":"FC901-U3 | Siemens 50-Point Addressable Fire Alarm Control Panel with 170W Power Supply","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens FC901-U3 Fire Alarm Control Panel is a 50-point addressable system designed for small to mid-size fire protection applications. It includes the FCM901-U3 main board and the FP2011-U1 170-watt power supply, providing reliable detection, notification, and control functions. With support for multiple circuits, integrated DACT, and versatile programming, it ensures dependable fire safety performance.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 411.615px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\n\u003cstrong\u003ePart\u003c\/strong\u003e \u003cstrong\u003eNumber\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eFC901-U3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eFire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 39.2014px;\"\u003e\u003cstrong\u003eSecondary Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 39.2014px;\"\u003eFCM901-U3 (main board), FP2011-U1 (170W power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eStyle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eAddressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eSystem Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003e50 addressable devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eNotification Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003e1 Class A or 2 Class B NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003e170W, FP2011-U1 with surge and noise suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eBuilt-in DACT, RS-485 for remote annunciators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eOptional Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eCity-tie (FCI2020-U1), PAD-5, X-Series I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eCO Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eSupported (not for Canada use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eEvent Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eDownloads and prints system history and detector sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eSupports 182-character display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eAuxiliary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eResettable and non-resettable 24 VDC outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003e16.50 × 18.13 × 5.11 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 27.6708%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1905%; height: 19.6007px;\"\u003e16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About FC901-U3\u003c\/h4\u003e\n\u003cp\u003eThe FC901-U3 is part of Siemens’ advanced addressable control panel lineup, built for applications requiring up to 50 devices. It comes as a complete electronics kit, combining the FCM901-U3 main board with the FP2011-U1 power supply, while the enclosure is sold separately. The system supports both Class A and Class B device loops, built-in digital alarm communication transmission, and integration with optional modules such as leased-line\/city-tie connectivity. With features like remote annunciator support, CO detection capability, and programmable controls, it is well-suited for flexible installation in modern facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e50 Addressable Points: Supports one Class A or two Class B device loops for detection and monitoring.\u003c\/li\u003e\n\u003cli\u003eIntegrated Power Supply: Includes FP2011-U1 170-watt power supply with surge and noise suppression.\u003c\/li\u003e\n\u003cli\u003eNotification Support: Provides one Class A or two Class B NACs for alarm signaling.\u003c\/li\u003e\n\u003cli\u003eBuilt-in DACT: Digital Alarm Communication Transmitter for direct reporting to monitoring centers.\u003c\/li\u003e\n\u003cli\u003eExpansion Options: Supports PAD-5, X-Series I\/O, and optional leased-line\/city-tie module (FCI2020-U1).\u003c\/li\u003e\n\u003cli\u003eCO Detection Capability: Compatible with carbon monoxide detection devices (not Canada-approved).\u003c\/li\u003e\n\u003cli\u003eUser-Friendly Setup: Custom-configuration tool enables quick installation and programming.\u003c\/li\u003e\n\u003cli\u003eCommunication Interfaces: RS-485 for remote annunciators and supervised printer output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FC901-U3 delivers the reliability and precision required for small to mid-size fire detection and control applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105187078400,"sku":"FC901-U3","price":1843.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Siemens-FC901-U3.jpg?v=1785542146"},{"product_id":"siemens-fc922-us-cerberus-pro-252-point-fire-alarm-control-panel-with-170w-power-supply","title":"Siemens FC922-US Cerberus PRO 252-Point Fire Alarm Control Panel with 170W Power Supply","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens FC922-US Fire Alarm Control Panel is a 252-point, addressable system engineered for mid-size building fire protection. Equipped with a 170-watt power supply and standard operator interfaces, it provides reliable detection, notification, and system control. Designed for scalability, the panel supports networking and future expansion as building needs grow.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 392.014px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFC922-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eSiemens Industry, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eSecondary Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eS54400-C14-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eCerberus PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eStyle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eAddressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eSystem Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003e252 addressable points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFP2011-U1, 170-watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eOperator Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFCM2018-U3 standard operator unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003ePeriphery Board\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFCI2016-U1, 252-point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eFlash EEPROM programmable storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003e5.75 × 21.5 × 27.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 37.9111%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.95%; height: 19.6007px;\"\u003e16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FC922-US\u003c\/h4\u003e\n\u003cp\u003eThe FC922-US is part of the Siemens Cerberus PRO Series, built to deliver advanced fire safety for mid-range applications. It comes with a 252-point periphery board, ensuring precise addressable device monitoring, and is expandable via system networking to support larger installations. Programming is stored in flash EEPROM memory, allowing easy configuration updates without hardware changes. This model includes the FP2011-U1 170-watt power supply, the FCI2016-U1 252-point board, and the FCM2018-U3 operator interface, making it a complete package for dependable system deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable Capacity: Supports up to 252 addressable points for mid-size building coverage.\u003c\/li\u003e\n\u003cli\u003eIntegrated Power Supply: 170-watt FP2011-U1 power supply for reliable system operation.\u003c\/li\u003e\n\u003cli\u003eStandard Operator Interfaces: Includes FCM2018-U3 for intuitive system control and monitoring.\u003c\/li\u003e\n\u003cli\u003eExpandable System: Supports networking with other Cerberus PRO panels for scalable protection.\u003c\/li\u003e\n\u003cli\u003eFlash EEPROM Storage: Provides secure programming with easy update capability.\u003c\/li\u003e\n\u003cli\u003eIncluded Periphery Board: FCI2016-U1 board enables addressable device management.\u003c\/li\u003e\n\u003cli\u003eDurable Build: Designed for long-term reliability in commercial and institutional environments.\u003c\/li\u003e\n\u003cli\u003eCompact Dimensions: Panel size ensures flexible installation in various building layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FC922-US delivers the reliability and precision required for professional fire detection and control systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105187143936,"sku":"FC922-US","price":2644.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fc922-us_edited.jpg?v=1785542148"},{"product_id":"s54339-a5-a1-siemens-pad-5-mb-main-board-for-notification-power-extender","title":"S54339-A5-A1 | Siemens PAD-5-MB Main Board for Notification Power Extender","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens S54339-A5-A1 is the PAD-5-MB main board designed for use with PAD-5 notification-extender units in Siemens Modular fire alarm systems. It provides remote auxiliary power for signaling appliances while supporting expansion of multiple notification appliance circuits (NACs). The module ensures reliable communication with the XDLC loop card and delivers robust functionality for life safety applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS54339-A5-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotification Appliance Extender Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePAD-5-MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens Modular Fire Alarm Panels (X-Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP2 loop via XDLC card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 system address, programmed via DPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Class A or 8 Class B (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Class X device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrouble relay for supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature-compensated charging circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiagnostic LEDs for status\/faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 32 PAD-5 boards per XDLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens XDLC and PAD-5 notification extenders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eS54339-A5-A1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe S54339-A5-A1 is the PAD-5-MB main board for Siemens PAD-5 notification power extender units, engineered to expand notification capacity in X-Series modular fire alarm control systems. It connects directly to the P2 loop of a Siemens XDLC (Device Loop Card) and can support up to 32 interconnected PAD-5 units or expansion boards per loop. With one programmable address set through the Siemens DPU device programmer, the PAD-5-MB enables flexible and scalable notification power distribution. Its design incorporates advanced features such as Class A\/B NAC wiring support, Class X isolation, onboard diagnostics, and temperature-compensated battery charging, making it a critical element in expanding large-scale fire alarm installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Auxiliary Power: Supplies additional power to notification appliances in Siemens fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eExpandable NAC Support: Provides four Class A or eight Class B circuits with mix-and-match configuration.\u003c\/li\u003e\n\u003cli\u003eXDLC Loop Integration: Connects via P2 loop to Siemens Modular fire-alarm control panels.\u003c\/li\u003e\n\u003cli\u003eAddressable Programming: Supports one system address configured through the Siemens DPU programmer.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Isolation: Class X wiring isolator enhances circuit fault tolerance.\u003c\/li\u003e\n\u003cli\u003eBattery Charging: Includes temperature-compensated charging circuits for reliable backup power.\u003c\/li\u003e\n\u003cli\u003eSystem Monitoring: Equipped with “trouble” relay outputs for remote supervision.\u003c\/li\u003e\n\u003cli\u003eDiagnostic LEDs: Provides clear visual indicators for status and fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe S54339-A5-A1 delivers the reliability and scalability required for extending notification circuits in Siemens Modular fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105199530240,"sku":"S54339-A5-A1","price":1196.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_4df79aaf-a5b2-483e-b0ee-199bc94e890e.webp?v=1785542403"},{"product_id":"tri-d-siemens-dual-interface-module-for-fire-alarm-systems","title":"TRI-D | Siemens Dual Interface Module for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Siemens TRI-D Dual Interface Module provides two independent addressable inputs for monitoring contact-type devices within Siemens fire alarm systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 382.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eFire Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eTRI-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eInterface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eDual addressable input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eInputs Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eTwo supervised dry-contact devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eAddressable signaling to Siemens control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 39.2px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 39.2px;\"\u003eMonitoring pull stations, waterflow, supervisory, and contact devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eStandard electrical box mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eTermination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eScrew terminal connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003ePanel-supplied via signaling line circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003ePanel-based addressable reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003eUL Listed, NFPA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 39.2px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 39.2px;\"\u003eIndoor, commercial, and industrial facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 10px;\"\u003e\u003cstrong\u003eBoard\/Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 10px;\"\u003eCompact module design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003ePeriodic inspection and testing recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.5013%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.3323%; height: 19.6px;\"\u003e0.4 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TRI-D\u003c\/h4\u003e\n\u003cp\u003eThe TRI-D is a dual input module in Siemens’ addressable device family, designed to connect and supervise two independent dry-contact devices. It communicates directly with Siemens intelligent control panels, ensuring accurate event reporting and system integration. The module is built to mount within standard electrical enclosures and includes wiring terminals for ease of installation. With its dual-channel capability, the TRI-D reduces space and wiring requirements while providing flexible monitoring of field devices in commercial and industrial fire detection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Input Channels: Supports two addressable contact-type devices on a single module.\u003c\/li\u003e\n\u003cli\u003eAddressable Communication: Interfaces directly with Siemens intelligent fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eSpace-Saving Design: Consolidates two inputs into one device, reducing panel and wiring demand.\u003c\/li\u003e\n\u003cli\u003eSupervised Monitoring: Provides continuous supervision of connected dry-contact circuits.\u003c\/li\u003e\n\u003cli\u003eFlexible Applications: Compatible with pull stations, waterflow devices, and supervisory switches.\u003c\/li\u003e\n\u003cli\u003eEasy Installation: Fits into standard electrical boxes with accessible terminal connections.\u003c\/li\u003e\n\u003cli\u003eUL Listed Compliance: Meets fire safety standards for use in critical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TRI-D delivers the reliability and precision required for integrating multiple monitored devices into Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105204183296,"sku":"TRI-D","price":1325.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/siemens-tri-d-back.jpg?v=1785542499"},{"product_id":"ilp-1-siemens-photoelectric-smoke-detector-for-fire-alarm-systems","title":"ILP-1 | Siemens Photoelectric Smoke Detector for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Siemens ILP-1 Photoelectric Smoke Detector is a reliable sensing device designed to detect visible particles of combustion for early fire detection. Part number ILP-1 provides precise photoelectric sensing suitable for commercial and industrial fire alarm systems, ensuring timely detection of smoke in diverse applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 372.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eFire Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eILP-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eSmoke Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003ePhotoelectric (light-scattering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eCommercial, industrial, institutional buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eSiemens fire alarm panels and system bases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eAlarm Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eSmoke detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eFalse Alarm Reduction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eDust-resistant optical chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eStandard Siemens base mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003ePanel-supplied (via system wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eIndoor, controlled environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eDurable fire-resistant polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003ePeriodic cleaning and testing recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eUL Listed, NFPA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eStandard detector size (varies by base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003eLong-term service with routine inspection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.488%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3456%; height: 19.6px;\"\u003e0.5 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About ILP-1\u003c\/h4\u003e\n\u003cp\u003eThe ILP-1 is part of Siemens’ photoelectric smoke detector series, engineered for integration into conventional and intelligent fire detection systems. It uses a light-scattering principle to sense smoke particles, providing high sensitivity while reducing false alarms from dust or ambient light. The detector is compatible with Siemens system bases and control panels, making it suitable for new installations or retrofits. Designed for use in office buildings, healthcare facilities, and industrial environments, the ILP-1 combines robust build quality with proven detection technology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhotoelectric Sensing Technology: Detects visible combustion particles using a light-scattering principle for early smoke detection.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for use with Siemens control panels and compatible detector bases.\u003c\/li\u003e\n\u003cli\u003eReduced False Alarms: Optimized optical chamber minimizes nuisance triggers from dust and ambient light.\u003c\/li\u003e\n\u003cli\u003eWide Application Range: Suitable for commercial, industrial, and institutional environments.\u003c\/li\u003e\n\u003cli\u003eRobust Construction: Built with durable materials for long service life in demanding conditions.\u003c\/li\u003e\n\u003cli\u003eEasy Installation: Mounts quickly to Siemens system bases with standardized connections.\u003c\/li\u003e\n\u003cli\u003eLow Maintenance: Designed for extended operational reliability with minimal upkeep.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ILP-1 delivers the reliability and precision required for critical fire detection in life safety systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105204445440,"sku":"ILP-1","price":877.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/19aeb1039fbb4cccad14f82c5acd6869.jpg?v=1785542502"},{"product_id":"xdlc-siemens-class-x-device-loop-card-for-xls-fire-alarm-panels","title":"XDLC | Siemens Class X Device Loop Card for XLS Fire Alarm Panels","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Siemens XDLC is a Class X device loop card designed for use with Siemens XLS fire alarm control panels. It provides a high-capacity communication channel for addressable detectors, modules, and notification devices.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 352.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eFire \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eXDLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eClass X Device Loop Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eSiemens XLS fire alarm panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eLoop Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eClass X (fault-tolerant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eDevice Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eHigh point capacity (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eProvides device communication and supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eAddressable loop protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eInstalled in XLS system card cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eUL Listed, NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 39.2px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 39.2px;\"\u003eLarge commercial, healthcare, industrial, and high-rise facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eRequires protected installation inside FACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003e0 °C to +49 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4913%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.3423%; height: 19.6px;\"\u003eApprox. 0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About XDLC\u003c\/h4\u003e\n\u003cp\u003eThe XDLC is part of Siemens’ XLS fire alarm system components, engineered to expand device connectivity and supervision. This loop card enables Class X operation, offering redundant, fault-tolerant communication for mission-critical environments. Each XDLC supports multiple addressable points, allowing system designers to scale protection for large facilities. UL and NFPA compliant, the XDLC is widely used in high-rises, hospitals, industrial plants, and other large-scale fire protection installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass X Loop Card: Provides fault-tolerant device communication.\u003c\/li\u003e\n\u003cli\u003eXLS System Compatible: Designed for Siemens XLS fire alarm panels.\u003c\/li\u003e\n\u003cli\u003eHigh Device Capacity: Supports multiple addressable detectors and modules.\u003c\/li\u003e\n\u003cli\u003eRedundant Communication: Ensures loop integrity under fault conditions.\u003c\/li\u003e\n\u003cli\u003eSystem Expansion: Adds scalable device capacity to existing systems.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Compliant: Meets fire and life safety standards.\u003c\/li\u003e\n\u003cli\u003eReliable Operation: Engineered for continuous duty in critical facilities.\u003c\/li\u003e\n\u003cli\u003eOEM Quality: Manufactured to Siemens engineering specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XDLC delivers the scalability and fault tolerance required for advanced Siemens XLS fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105204576512,"sku":"XDLC","price":1946.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l300_9d8783fd-12b5-483a-b129-7a46ed5f4aa2.webp?v=1785542505"},{"product_id":"pad-5-mb-siemens-addressable-power-supply-main-board-for-fire-alarm-systems","title":"PAD-5-MB | Siemens Addressable Power Supply Main Board for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Siemens PAD-5-MB Addressable Power Supply Main Board provides regulated auxiliary power for Siemens fire alarm and life safety systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 411.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eFire Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003ePAD-5-MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003ePower Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eAddressable power supply main board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003ePAD-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eFire alarm system power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eSiemens fire alarm control panels and expansion modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003ePanel-supplied (dependent on PAD-5 assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eRegulated auxiliary system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 39.2px;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 39.2px;\"\u003eSupports notification appliances, initiating devices, auxiliary circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eMain board for power supply assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eUL Listed, NFPA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eMounts within Siemens system enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eHousing\/Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003eBare board (main module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 39.2px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 39.2px;\"\u003eIndoor, controlled fire alarm environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003ePeriodic inspection recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 26.6828%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.1508%; height: 19.6px;\"\u003e1.2 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About PAD-5-MB\u003c\/h4\u003e\n\u003cp\u003eThe PAD-5-MB is the main board of the Siemens PAD-5 power supply series, designed for addressable fire alarm systems requiring supplemental power. It serves as the central module within the expansion assembly, providing regulated output to support notification appliances, initiating devices, and auxiliary equipment. The board integrates with Siemens system enclosures and control units, ensuring compatibility with a wide range of installations. With a rugged design tailored for life safety environments, the PAD-5-MB enhances system reliability while maintaining code-compliant operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable Integration: Functions as part of Siemens addressable fire alarm systems for coordinated operation.\u003c\/li\u003e\n\u003cli\u003ePrimary System Board: Serves as the main board of the PAD-5 auxiliary power supply.\u003c\/li\u003e\n\u003cli\u003eStable Power Output: Provides regulated current for devices such as notification appliances and auxiliary circuits.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for Siemens fire alarm panels and expansion modules.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Built with high-quality electronic components for dependable service life.\u003c\/li\u003e\n\u003cli\u003eSupport for Expansion: Enables larger fire detection systems to operate efficiently by adding supplemental power.\u003c\/li\u003e\n\u003cli\u003eUL Listed Design: Complies with safety and performance standards for fire alarm equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PAD-5-MB delivers the reliability and precision required for dependable system power in Siemens fire alarm installations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105204609280,"sku":"PAD-5-MB","price":1406.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/51ebd9afdb3040afa7f7b4a9fd1e08e7.jpg?v=1785542504"},{"product_id":"el-410d-siemens-voice-evacuation-amplifier-100w","title":"EL-410D | Siemens Voice Evacuation Amplifier, 100W","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens EL-410D is a voice evacuation amplifier designed for use in Siemens fire alarm and emergency communication systems. It delivers 100 watts of audio power for paging, alarm tones, and evacuation messaging in life safety applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 333.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eFire \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eEL-410D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eVoice Evacuation Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eAudio amplifier module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eSiemens fire alarm and voice evacuation systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eAmplifies paging, alarm tones, and evacuation messages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003ePanel-supplied low-voltage DC \/ AC input (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eContinuous duty rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eInternal installation within system cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eElectronic overload and short-circuit safeguards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eUL Listed, NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eSchools, hospitals, commercial and industrial facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003e0 °C to +49 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.5996%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2673%; height: 19.6px;\"\u003eApprox. 5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About EL-410D\u003c\/h4\u003e\n\u003cp\u003eThe EL-410D is part of Siemens’ fire and voice evacuation product line, engineered to integrate with compatible control panels and audio systems. This amplifier supports distributed audio output, ensuring reliable delivery of voice instructions and emergency tones throughout a facility. Built for critical life safety use, it provides stable amplification under continuous operation. UL-listed and NFPA-compliant, the EL-410D is widely applied in schools, hospitals, commercial buildings, and industrial facilities requiring dependable emergency communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100W Amplifier: Provides robust audio output for life safety systems.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for Siemens voice evacuation systems.\u003c\/li\u003e\n\u003cli\u003eReliable Audio Delivery: Ensures clear paging, tones, and evacuation messaging.\u003c\/li\u003e\n\u003cli\u003eContinuous Duty: Built for 24\/7 operation in emergency systems.\u003c\/li\u003e\n\u003cli\u003eModular Design: Fits within Siemens fire alarm audio cabinets.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Compliant: Meets fire and life safety regulatory requirements.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Engineered for long service life in demanding environments.\u003c\/li\u003e\n\u003cli\u003eOEM Quality: Manufactured to Siemens specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EL-410D delivers the reliability and clarity required for emergency voice evacuation and public safety communications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105209655552,"sku":"EL-410D","price":6107.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l960_71d3960d-7f44-4dd6-bf0d-0fff8bd99996.webp?v=1785542576"},{"product_id":"hfpo-11-siemens-photoelectric-fireprint-smoke-detector-2-wire-fs-250-compatible","title":"HFPO-11 | Siemens Photoelectric FirePrint Smoke Detector, 2-Wire, FS-250 Compatible","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens HFPO-11 is a photoelectric smoke detector designed exclusively for the FS-250 fire alarm control panel. This intelligent, two-wire, plug-in detector provides reliable fire detection using FirePrint™ technology, ensuring rapid response to smoke while minimizing nuisance alarms. Compact and low profile, the HFPO-11 integrates seamlessly into Siemens fire safety systems for dependable protection.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eHFPO-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eSmoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eIntelligent Photoelectric, FirePrint™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eFS-250 Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003e2-Wire, Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eTri-color LED (green, yellow, red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003e12 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003e0.55 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003e32°F to 100°F (0°C to 38°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eUp to 93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eAir Velocity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003e0–4000 ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003e4.3 in (109 mm) square × 1.06 in (27 mm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eDB-11 detector base (optional DB-HR relay base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaintenance Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003eDMK-11 (for cleaning\/replacement of parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.9685%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7188%; height: 19.5938px;\"\u003e0.30 lbs (approx. 110 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eHFPO-11\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe HFPO-11 is part of Siemens’ line of intelligent photoelectric detectors, developed for high-performance fire detection in commercial and institutional environments. Engineered with FirePrint™ technology, it distinguishes between real fire signatures and environmental disturbances, reducing false alarms. It is a microprocessor-based detector that performs self-checks and uses tri-color LED indicators (green, yellow, red) to display operating, service, or alarm conditions. Designed for use with Siemens FS-250 panels, the HFPO-11 offers simplified installation through its plug-in base, compatibility with optional detector guards, and straightforward addressing using Siemens programming tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhotoelectric FirePrint™ Technology: Provides intelligent detection while minimizing nuisance alarms.\u003c\/li\u003e\n\u003cli\u003eExclusive Compatibility: Designed for Siemens FS-250 fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eTri-Color LED Indicators: Green (normal), yellow (service required), and red (alarm) status.\u003c\/li\u003e\n\u003cli\u003eWide Environmental Range: Operates in conditions up to 93% humidity and 0–4000 ft\/min air velocity.\u003c\/li\u003e\n\u003cli\u003ePlug-In Base Mounting: Ensures quick installation and secure locking with optional LK-11 screw.\u003c\/li\u003e\n\u003cli\u003eProgrammable Addressing: Uses Siemens DPU or configuration tools for flexible setup.\u003c\/li\u003e\n\u003cli\u003eField Cleanable: Can be disassembled and cleaned with maintenance kit DMK-11.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Compliant: Meets NFPA 72, CAN\/ULC-S524, and international safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HFPO-11 delivers the precision and reliability required for advanced Siemens fire detection systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105216667904,"sku":"HFPO-11","price":1115.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/sie_hfpo-11.jpg?v=1785542732"},{"product_id":"fs-rd2-siemens-remote-lcd-annunciator-for-fs-250-fire-control-panel","title":"FS-RD2 | Siemens Remote LCD Annunciator for FS-250 Fire Control Panel","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens FS-RD2 is a remote LCD annunciator module designed for use with FS-250 fire control panels. It provides clear visual status indications, enabling operators to monitor system conditions efficiently from remote locations.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFS-RD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD \u0026amp; LED Displays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote LCD Annunciator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens FS-250 Fire Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote monitoring and annunciation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm system integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFS-250 panel connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Role\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvent and status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FS-RD2\u003c\/h4\u003e\n\u003cp\u003eThe FS-RD2 is a Siemens remote display unit built specifically for the FS-250 series fire alarm control panels. It enhances system usability by allowing distributed annunciation of panel events without requiring access to the main unit. This module features a reliable LCD interface, delivering clear event and status information to operators. Designed for integration in fire protection systems, the FS-RD2 helps improve response time and monitoring accuracy in building safety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Annunciation: Provides remote status and event indication for FS-250 fire control panels.\u003c\/li\u003e\n\u003cli\u003eLCD Interface: Clear display of system conditions for easy monitoring.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed exclusively for Siemens FS-250 fire control systems.\u003c\/li\u003e\n\u003cli\u003eEnhanced Safety Monitoring: Extends annunciation points throughout a facility for faster response.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Built for reliable operation in fire safety environments.\u003c\/li\u003e\n\u003cli\u003eEase of Integration: Simple connection to the FS-250 system for seamless installation.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Allows convenient placement in various monitoring locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FS-RD2 delivers the reliability and precision required for effective remote annunciation in fire protection systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105216700672,"sku":"FS-RD2","price":2350.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_d5e52b98-d55d-42af-93ec-4aa22bb603e7.webp?v=1785542733"},{"product_id":"580-034170-5-siemens-ssd-c-rem-field-mounted-remote-lcd-display","title":"580-034170-5 | Siemens SSD-C-REM Field Mounted Remote LCD Display","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens 580-034170-5 SSD-C-REM is a field-mounted remote LCD display module designed for Siemens fire alarm control panels. It provides system event status, remote system control, and message supervision, with integrated LEDs, pushbuttons, and optional sounder functionality.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.469px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003e580-034170-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eRemote Annunciators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eSSD-C-REM Field Mounted Remote LCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eLCD with event message capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eEvent Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eUp to 1,500 event messages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003ePushbuttons for message scrolling and system operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eIntegrated LEDs for system status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eSounder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eOptional internal sounder for audible status alerts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 39.1875px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 39.1875px;\"\u003eDisplays system event status, provides supervision, and supports remote system control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 39.1875px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 39.1875px;\"\u003ePMI\/PMI-2\/PMI-3 (XLS), FCM2041-U2 (Desigo Fire Safety Modular), FCM2041-U3 (Cerberus PRO Modular)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eFully supervised by the main control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 39.1875px;\"\u003eDefault display-only mode at initial power-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eField-mounted installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eUL Listed, NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 20.6939%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.9424%; height: 19.5938px;\"\u003eApprox. 2–3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e580-034170-5\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 580-034170-5 SSD-C-REM is part of Siemens’ range of field-mounted fire alarm accessories designed to enhance system visibility and control. This LCD display module provides operators with real-time access to system event messages, system status, and supervisory functions. It can store up to 1,500 event messages and features scrolling pushbuttons for reviewing historical or active system conditions. Integrated LEDs and an optional sounder provide clear visual and audible indications, while its supervised connection to the main control panel ensures consistent reliability. Designed for use with PMI\/PMI-2\/PMI-3 (XLS), FCM2041-U2 (Desigo Fire Safety Modular), and FCM2041-U3 (Cerberus PRO Modular), the SSD-C-REM increases system flexibility in distributed installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSystem Event Display: LCD screen provides detailed fire alarm system event status directly at the field location.\u003c\/li\u003e\n\u003cli\u003eEvent Storage Capability: Stores up to 1,500 system event messages for reference and review.\u003c\/li\u003e\n\u003cli\u003eRemote System Control: Allows control of connected Siemens systems including alarm acknowledgments and supervisory functions.\u003c\/li\u003e\n\u003cli\u003eMessage Navigation: Pushbuttons allow scrolling through stored events for efficient system management.\u003c\/li\u003e\n\u003cli\u003eLED Indicators: Integrated LEDs provide visual indication of alarms, troubles, and system status.\u003c\/li\u003e\n\u003cli\u003eOptional Sounder: Internal sounder audibly signals system events for enhanced operator awareness.\u003c\/li\u003e\n\u003cli\u003ePanel Supervision: Fully supervised by the host control panel to ensure reliable communication and functionality.\u003c\/li\u003e\n\u003cli\u003eWide Compatibility: Works with PMI\/PMI-2\/PMI-3 (XLS), FCM2041-U2 (Desigo Fire Safety Modular), and FCM2041-U3 (Cerberus PRO Modular).\u003c\/li\u003e\n\u003cli\u003eIndependent Operation: Display functions independently from the main panel display, ensuring redundancy.\u003c\/li\u003e\n\u003cli\u003eSecure Initialization: Default display-only mode during power-up to maintain system integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 580-034170-5 delivers the reliability and precision required for remote system annunciation, supervision, and operator control within Siemens fire alarm installations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105216897280,"sku":"580-034170-5","price":1406.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l400_4686b52b-a392-40ac-8d08-bb6d8c6c0658.png?v=1785542738"},{"product_id":"msi-10b-siemens-single-action-intelligent-manual-fire-alarm-pull-station","title":"MSI-10B | Siemens Single-Action Intelligent Manual Fire Alarm Pull Station","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens MSI-10B is a single-action, addressable manual pull station designed for use with MXL, IXL\/ICON-1, and XL3 fire alarm control panels. Built with a durable polycarbonate housing, it provides reliable manual fire alarm activation with a secure reset mechanism.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eMSI-10B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eManual Pull Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eIntelligent, single-action, addressable pull station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eSiemens MXL, IXL\/ICON-1, XL3 control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eMolded polycarbonate, matte red finish with raised white lettering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eActivation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eSingle-action pull-down lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eLever Lock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eLever locks in down position until reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eReset Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eHinged cover, reset with Allen key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eLettering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eWhite raised “FIRE ALARM” text on red housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eAddressable manual fire alarm activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eDurable, impact-resistant enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eUL Listed, NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003eStandard manual station size (panel mount design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.4663%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.17%;\"\u003e0.80 lbs (0.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eMSI-10B\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe MSI-10B is a Siemens intelligent manual fire alarm pull station engineered for dependable use in commercial and institutional buildings. Featuring a single-action pull-down lever, the station provides immediate alarm activation when engaged and locks in position to clearly indicate alarm status. Resetting requires opening the hinged housing with an Allen key, ensuring system integrity and preventing unauthorized resets. Constructed from durable polycarbonate with a red matte finish and raised white lettering, the MSI-10B combines reliability with high visibility in emergency situations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-Action Pull Lever: Provides fast and simple alarm activation with one downward motion, ensuring quick response in emergencies.\u003c\/li\u003e\n\u003cli\u003eIntelligent Addressable Design: Integrates with Siemens MXL, IXL\/ICON-1, and XL3 systems for precise device identification and system monitoring.\u003c\/li\u003e\n\u003cli\u003eDurable Polycarbonate Housing: Molded, impact-resistant red case with matte finish withstands heavy use and environmental stress.\u003c\/li\u003e\n\u003cli\u003eSecure Locking Mechanism: Lever remains in the activated down position until the unit is reset, preventing accidental resets or misinterpretation of alarm status.\u003c\/li\u003e\n\u003cli\u003eControlled Reset Process: Reset requires opening the hinged cover with an Allen key, ensuring that only authorized personnel can restore the station.\u003c\/li\u003e\n\u003cli\u003eHigh-Visibility Markings: Raised white “FIRE ALARM” lettering contrasts with the red housing for clear recognition in public and emergency environments.\u003c\/li\u003e\n\u003cli\u003eUL \u0026amp; NFPA Certified: Meets UL listing requirements and NFPA 72 fire code standards for installation in commercial and institutional settings.\u003c\/li\u003e\n\u003cli\u003eLightweight and Compact: At only 0.80 lbs, it is easy to mount, maintain, and service without adding bulk to the system.\u003c\/li\u003e\n\u003cli\u003eSystem Reliability: Designed to integrate seamlessly with Siemens fire alarm networks, enhancing overall system performance and compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MSI-10B delivers the reliability and precision required for manual fire alarm activation in Siemens intelligent fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105216962816,"sku":"MSI-10B","price":1064.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/shopping_100_ec91e328-f109-4845-8959-c87270e03f40.webp?v=1785542744"}],"url":"https:\/\/alotechparts.com\/collections\/siemens-fire-alarm-life-safety.oembed?page=3","provider":"Alo Tech Solutions","version":"1.0","type":"link"}