{"title":"Notifier Parts","description":"\u003cp\u003eAlo Tech stocks 157 Notifier products across security cameras, PLC \u0026amp; I\/O, pro audio \u0026amp; AV, power supplies. Popular Notifier families: ACPS-610, 640-CHARACTER, NFS2-640, NFS-640, 80-CHARACTER, FSB-200S. Every order ships worldwide DDP with duties and taxes included; B2B customers receive a formal quote within 24 hours and can pay by purchase order.\u003c\/p\u003e\u003cp class=\"seo-links\"\u003eBrowse Notifier by category: \u003ca href=\"\/collections\/notifier-security-cameras-surveillance\"\u003eNotifier security cameras\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"notifier-fsb-200s-intelligent-addressable-reflective-beam-smoke-detector","title":"Notifier FSB-200S Intelligent Addressable Reflective Beam Smoke Detector","description":"\u003ch4 data-start=\"0\" data-end=\"14\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003eThe Notifier FSB-200S is an intelligent addressable reflected beam smoke detector designed for smoke detection in large open areas where conventional spot-type detectors are difficult to install or maintain. It uses a transmitter\/receiver and reflector design to monitor smoke obscuration across extended distances, making it suitable for high ceilings, warehouses, atriums, hangars, and large commercial facilities. The detector provides advanced sensitivity adjustment, automatic compensation, and remote testing capabilities for reliable fire detection.\u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"16\" data-end=\"389\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSB-200S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Beam Smoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent Reflective Beam Smoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInfrared reflected beam smoke detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFS-3030, NFS2-3030, NFS-640, NFS2-640, NFS-320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashScan® and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 to 230 ft (5 to 70 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 328 ft (100 m) with BEAMLRK kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSix selectable levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAcclimate® Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLevel 5 and Level 6 adaptive sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBeam Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10° horizontal and vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlignment Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptical sight and digital signal strength display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA maximum at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrouble Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlignment Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Test Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 to 32 VDC, 0.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Alarm Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 to 32 VDC, 15 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22°F to 131°F (-30°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 93% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSmoke Detector Spacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 to 60 ft between beams on smooth ceilings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall or ceiling with optional BEAMMMK kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEAMLRK, BEAMMMK, BEAMHK, BEAMHKR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 268, ULC CAN\/ULC S529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge-area commercial smoke detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"391\" data-end=\"411\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eFSB-200S\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"605\" data-end=\"1315\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe FSB-200S is part of the NOTIFIER intelligent beam smoke detector family, engineered for use with ONYX® Series fire alarm control panels and compatible addressable systems. The detector combines a single-ended reflective optical design with integrated alignment tools, including an optical sight and digital signal strength display for simplified installation. It supports six sensitivity levels, including Acclimate® settings that automatically adjust detection thresholds based on environmental conditions. The FSB-200S includes an integral motorized sensitivity test filter and is designed for applications requiring dependable smoke detection across large distances and challenging architectural spaces.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1317\" data-end=\"1332\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1334\" data-end=\"2721\"\u003e\n\u003cli data-start=\"1334\" data-end=\"1469\"\u003eIntelligent Addressable Detection: Provides monitored smoke detection with addressable communication for NOTIFIER fire alarm systems.\u003c\/li\u003e\n\u003cli data-start=\"1470\" data-end=\"1591\"\u003eReflected Beam Technology: Uses a combined transmitter\/receiver and reflector system to detect smoke across open areas.\u003c\/li\u003e\n\u003cli data-start=\"1592\" data-end=\"1711\"\u003eExtended Coverage Range: Protects distances from 16 to 230 ft, expandable up to 328 ft with the optional BEAMLRK kit.\u003c\/li\u003e\n\u003cli data-start=\"1712\" data-end=\"1846\"\u003eLarge Area Applications: Designed for atriums, warehouses, aircraft hangars, arenas, parking structures, and high-ceiling buildings.\u003c\/li\u003e\n\u003cli data-start=\"1847\" data-end=\"1957\"\u003eFlashScan® and CLIP Compatibility: Operates with NFS-3030, NFS2-3030, NFS-640, NFS2-640, and NFS-320 panels.\u003c\/li\u003e\n\u003cli data-start=\"1958\" data-end=\"2074\"\u003eSix Sensitivity Settings: Provides multiple detection thresholds, including Acclimate® adaptive sensitivity modes.\u003c\/li\u003e\n\u003cli data-start=\"2075\" data-end=\"2190\"\u003eAutomatic Gain Control: Compensates for signal reduction caused by dust accumulation and gradual optical changes.\u003c\/li\u003e\n\u003cli data-start=\"2191\" data-end=\"2293\"\u003eDigital Alignment Display: Includes a two-digit signal strength indicator for easier beam alignment.\u003c\/li\u003e\n\u003cli data-start=\"2294\" data-end=\"2425\"\u003eIntegrated Sensitivity Testing: Features a built-in motorized filter test function compatible with RTS151 and RTS151KEY stations.\u003c\/li\u003e\n\u003cli data-start=\"2426\" data-end=\"2512\"\u003eWide Temperature Operation: Rated for operation from -22°F to 131°F (-30°C to 55°C).\u003c\/li\u003e\n\u003cli data-start=\"2513\" data-end=\"2618\"\u003eFlexible Mounting Options: Supports optional multi-mount and heater kits for specialized installations.\u003c\/li\u003e\n\u003cli data-start=\"2619\" data-end=\"2721\"\u003ePlug-In Terminals: Uses removable terminal blocks for simplified field installation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2723\" data-end=\"2873\"\u003eThe FSB-200S delivers the reliability and precision required for large-area addressable smoke detection and high-ceiling fire protection applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676225280,"sku":"FSB-200S","price":1762.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/notifier-fsb-200s-detector.jpg?v=1785530401"},{"product_id":"notifier-ds-sfm-single-mode-fiber-module-for-digital-audio-loop-systems","title":"Notifier DS-SFM Single-Mode Fiber Module for Digital Audio Loop Systems","description":"\u003ch4 data-start=\"0\" data-end=\"14\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003eThe Notifier DS-SFM is a single-mode fiber option module designed to convert digital audio ports on compatible NOTIFIER emergency voice systems from copper wiring to fiber-optic communication. It extends Digital Audio Loop (DAL) communication distances while maintaining reliable audio data transmission between DAA2, DAX, DS-DB, and DVC system components. The module is used in large-scale fire alarm voice evacuation systems requiring long-distance fiber connectivity.\u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"16\" data-end=\"389\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS-SFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Audio Fiber Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber Option Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDAA2, DAX, DS-DB, DVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNOTIFIER Digital Audio Loop (DAL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-mode fiber optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWire digital audio port to fiber optic port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne or two modules per compatible device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Media Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWire, single-mode fiber, multi-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency voice communication and mass notification systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital audio data transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHost Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDVC-EMPCC version or later for DVC applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal module installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePartial or complete fiber DAL conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial fire alarm installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNOTIFIER Digital Voice Command systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.25 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"391\" data-end=\"411\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eDS-SFM\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"517\" data-end=\"1190\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe DS-SFM is part of the NOTIFIER Digital Audio Loop fiber option module family, developed to provide single-mode fiber communication capability for emergency voice evacuation systems. The module installs into compatible DAA2, DAX, DS-DB, and DVC devices, converting one digital audio port from wired communication to fiber optic transmission. It supports mixed-media DAL networks where wire, single-mode fiber, and multi-mode fiber segments can operate together within the same audio loop architecture. The DS-SFM is designed for DVC-based emergency communication systems where extended distance, reduced signal interference, and reliable audio distribution are required.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1192\" data-end=\"1207\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1209\" data-end=\"2485\"\u003e\n\u003cli data-start=\"1209\" data-end=\"1327\"\u003eSingle-Mode Fiber Conversion: Converts one digital audio port from copper wiring to single-mode fiber communication.\u003c\/li\u003e\n\u003cli data-start=\"1328\" data-end=\"1443\"\u003eDigital Audio Loop Support: Enables fiber integration within NOTIFIER DAL emergency voice communication networks.\u003c\/li\u003e\n\u003cli data-start=\"1444\" data-end=\"1552\"\u003eExtended Communication Distance: Allows longer digital audio runs compared with traditional copper wiring.\u003c\/li\u003e\n\u003cli data-start=\"1553\" data-end=\"1636\"\u003eCompatible Host Devices: Designed for use with DAA2, DAX, DS-DB, and DVC systems.\u003c\/li\u003e\n\u003cli data-start=\"1637\" data-end=\"1716\"\u003eDVC Compatibility: Supports DVC systems requiring DVC-EMPCC version or later.\u003c\/li\u003e\n\u003cli data-start=\"1717\" data-end=\"1836\"\u003eMixed Media Networking: Allows wire, single-mode fiber, and multi-mode fiber segments on the same Digital Audio Loop.\u003c\/li\u003e\n\u003cli data-start=\"1837\" data-end=\"1941\"\u003eFlexible Installation: Supports installation of one or two fiber option modules in compatible devices.\u003c\/li\u003e\n\u003cli data-start=\"1942\" data-end=\"2038\"\u003eFiber-Based Communication: Provides reliable transmission using single-mode fiber optic cable.\u003c\/li\u003e\n\u003cli data-start=\"2039\" data-end=\"2168\"\u003eReduced Signal Interference: Fiber communication improves resistance to electromagnetic interference in demanding environments.\u003c\/li\u003e\n\u003cli data-start=\"2169\" data-end=\"2281\"\u003eEmergency Voice Integration: Supports distributed voice evacuation and mass notification system architectures.\u003c\/li\u003e\n\u003cli data-start=\"2282\" data-end=\"2391\"\u003eModular Expansion: Enables partial or complete conversion of digital audio networks to fiber communication.\u003c\/li\u003e\n\u003cli data-start=\"2392\" data-end=\"2485\"\u003eSystem Compatibility: Integrates with NOTIFIER ONYX® fire alarm voice evacuation solutions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2487\" data-end=\"2625\"\u003eThe DS-SFM delivers the reliability and precision required for fiber-based emergency voice communication and digital audio loop expansion.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676258048,"sku":"DS-SFM","price":424.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/hbt-fire-ds-db-assy-fnl-ds-db-primaryimage.webp?v=1785530401"},{"product_id":"notifier-ncm-w-noti-fire-net-network-communications-module","title":"Notifier NCM-W NOTI-FIRE-NET Network Communications Module","description":"\u003ch4 data-start=\"0\" data-end=\"14\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003eThe Notifier NCM-W is a Network Communications Module designed to connect NOTIFIER intelligent fire alarm control panels and network annunciators through the NOTI•FIRE•NET™ communication network. It provides reliable data exchange over shielded twisted-pair wiring, allowing multiple fire alarm nodes, control panels, and network devices to operate as an integrated system. The module is used for distributed fire alarm monitoring, programming access, and network expansion in commercial life safety applications.\u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"16\" data-end=\"389\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNCM-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNOTI•FIRE•NET™ Network Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFS-640, NFS-3030, NFS2-3030, NCA, NCA-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Medium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded twisted-pair copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNOTI•FIRE•NET™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e312.5 Kbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFPA Style 4 (Class B), NFPA Style 7 (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Distance Between Nodes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 ft (914 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen or closed loop operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransformer-coupled inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIP-switch enabled ground fault detection and EOL resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIB-W, MIB-WF, NAM-232W, NCM-W, NCS-W, RPT-W, RPT-WF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePluggable terminal blocks with strain relief\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial fire alarm network communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"391\" data-end=\"411\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eNCM-W\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"559\" data-end=\"1210\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe NCM-W is part of the NOTIFIER Network Communications Module family, providing a wired interface between NFS-640, NFS-3030, NFS2-3030 fire alarm control panels and NCA\/NCA-2 network annunciators. The module uses transformer-coupled network connections, dual communication ports, and configurable switches for ground fault detection and end-of-line termination. It supports NOTI•FIRE•NET™ network architectures using shielded twisted-pair copper wiring with Class A or Class B configurations. The NCM-W is designed for integration with devices such as MIB-W, NAM-232W, RPT-W, NCS-W, and additional NCM modules in large-scale fire protection systems.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1212\" data-end=\"1227\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1229\" data-end=\"2614\"\u003e\n\u003cli data-start=\"1229\" data-end=\"1363\"\u003eNOTI•FIRE•NET™ Network Interface: Provides communication between intelligent NOTIFIER fire alarm panels and network control devices.\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1482\"\u003eTwisted-Pair Communication: Uses shielded copper wiring for reliable network data transmission between system nodes.\u003c\/li\u003e\n\u003cli data-start=\"1483\" data-end=\"1596\"\u003eDual Network Ports: Includes two ports for flexible trunk connections and side-load programming configurations.\u003c\/li\u003e\n\u003cli data-start=\"1597\" data-end=\"1709\"\u003eClass A and Class B Support: Compatible with NFPA Style 7 (Class A) and NFPA Style 4 (Class B) network wiring.\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1799\"\u003eExtended Node Distance: Supports up to 3,000 ft (914 m) between adjacent network nodes.\u003c\/li\u003e\n\u003cli data-start=\"1800\" data-end=\"1923\"\u003eTransformer-Coupled Isolation: Provides electrical isolation between connected network nodes to improve system stability.\u003c\/li\u003e\n\u003cli data-start=\"1924\" data-end=\"2030\"\u003eGround Fault Detection: Includes DIP-switch enabled ground fault monitoring for network troubleshooting.\u003c\/li\u003e\n\u003cli data-start=\"2031\" data-end=\"2147\"\u003eBuilt-In End-of-Line Resistors: Allows activation of onboard termination resistors through configuration switches.\u003c\/li\u003e\n\u003cli data-start=\"2148\" data-end=\"2268\"\u003eFlexible Network Topology: Supports open and closed loop network arrangements for different installation requirements.\u003c\/li\u003e\n\u003cli data-start=\"2269\" data-end=\"2392\"\u003eBroad System Compatibility: Works with NFS-640, NFS-3030, NFS2-3030, NCA, NCA-2, and compatible NOTIFIER network modules.\u003c\/li\u003e\n\u003cli data-start=\"2393\" data-end=\"2498\"\u003eSimplified Installation: Features pluggable terminal blocks with strain relief for secure field wiring.\u003c\/li\u003e\n\u003cli data-start=\"2499\" data-end=\"2614\"\u003eHigh Reliability Communication: Provides stable network connectivity for distributed fire alarm system operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2616\" data-end=\"2767\"\u003eThe NCM-W delivers the reliability and precision required for NOTIFIER fire alarm network communication and multi-panel life safety system integration.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676323584,"sku":"NCM-W","price":1171.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/NotifierNCM-W_540x_7480b9d0-ef4c-49be-a69c-a4ac05a0dc84.jpg?v=1785530404"},{"product_id":"notifier-lcm-320-onyx-addressable-slc-loop-control-module","title":"Notifier LCM-320 ONYX Addressable SLC Loop Control Module","description":"\u003ch4 data-start=\"0\" data-end=\"14\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003eThe Notifier LCM-320 is a Loop Control Module designed to add additional Signaling Line Circuits (SLCs) to NOTIFIER ONYX® Series fire alarm control panels. It provides addressable loop expansion capability for NFS-3030, NFS2-3030, and compatible systems, supporting long-distance SLC communication and improved network flexibility. The module is used in commercial fire alarm installations requiring additional device capacity within a compact control panel configuration.\u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"16\" data-end=\"389\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCM-320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable SLC Loop Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eONYX® Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFS-3030, NFS2-3030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Expander\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLEM-320 Loop Expander Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal, 27.6 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 additional Signaling Line Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Loop Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12,500 ft (3,810 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted-pair, unshielded or shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Wire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 AWG to 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass B Loop Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms maximum per branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass A\/Style 6 \u0026amp; 7 Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms maximum per loop length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum SLC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised addressable SLC communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93% ±2% RH non-condensing at 90°F (32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, ULC, FM Approved, CSFM, FDNY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial addressable fire alarm expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.50 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"391\" data-end=\"411\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e LCM-320\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"520\" data-end=\"1152\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe LCM-320 is part of the NOTIFIER ONYX® Series loop control module family, developed to expand intelligent fire alarm control panels with additional SLC channels. The module provides plug-in installation, built-in degraded mode operation, and compatibility with LEM-320 loop expander modules for scalable system growth. It supports Class B (Style 4) SLC wiring with extended loop distances up to 12,500 feet using appropriate twisted-pair wiring. The LCM-320 is designed for use with NFS-3030, NFS2-3030 fire alarm control panels and integrates with NOTIFIER addressable devices for advanced detection and monitoring applications.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1154\" data-end=\"1169\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1171\" data-end=\"2442\"\u003e\n\u003cli data-start=\"1171\" data-end=\"1284\"\u003eSLC Loop Expansion: Adds additional Signaling Line Circuits to NOTIFIER ONYX® Series fire alarm control panels.\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1405\"\u003eONYX® Series Compatibility: Designed for NFS-3030 and NFS2-3030 systems with support for expanded loop configurations.\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1518\"\u003eLong Distance Communication: Supports SLC wiring distances up to 12,500 ft (3,810 m) on Class B Style 4 loops.\u003c\/li\u003e\n\u003cli data-start=\"1519\" data-end=\"1615\"\u003eLEM-320 Compatibility: Allows connection of Loop Expander Modules for additional SLC capacity.\u003c\/li\u003e\n\u003cli data-start=\"1616\" data-end=\"1735\"\u003ePlug-In Installation: Provides simple installation through direct module insertion into compatible fire alarm panels.\u003c\/li\u003e\n\u003cli data-start=\"1736\" data-end=\"1852\"\u003eDegraded Mode Operation: Maintains improved system survivability during certain communication or fault conditions.\u003c\/li\u003e\n\u003cli data-start=\"1853\" data-end=\"1951\"\u003eMultiple Loop Support: Enables multiple addressable loops within a compact fire alarm enclosure.\u003c\/li\u003e\n\u003cli data-start=\"1952\" data-end=\"2062\"\u003eSupervised SLC Operation: Provides monitored, power-limited communication for connected intelligent devices.\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2161\"\u003eFlexible Wiring Support: Operates with 12 AWG through 18 AWG twisted-pair wiring configurations.\u003c\/li\u003e\n\u003cli data-start=\"2162\" data-end=\"2259\"\u003eHigh Device Capacity: Expands system capability for larger addressable fire detection networks.\u003c\/li\u003e\n\u003cli data-start=\"2260\" data-end=\"2350\"\u003eCompact Module Design: Optimizes panel space while adding additional loop functionality.\u003c\/li\u003e\n\u003cli data-start=\"2351\" data-end=\"2442\"\u003eAgency Approved Design: Listed for UL, ULC, FM, CSFM, FDNY, and other regional approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2444\" data-end=\"2591\"\u003eThe LCM-320 delivers the reliability and precision required for addressable fire alarm loop expansion and intelligent detection system integration.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676684032,"sku":"LCM-320","price":874.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/LCM-320-1.jpg?v=1785530410"},{"product_id":"notifier-hs-ncm-w-v21-high-speed-notifirenet-network-communications-module","title":"Notifier HS-NCM-W V21 High-Speed NOTI•FIRE•NET Network Communications Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Notifier HS-NCM-W V21 is a high-speed network communications module designed to connect NOTIFIER fire alarm control panels and network nodes through the NOTI•FIRE•NET™ HS-NFN network. It provides reliable 12 Mbps data communication over twisted-pair wiring, supporting remote programming, system monitoring, and integration of distributed fire alarm components. The module is used in large-scale life safety systems requiring dependable network communication between multiple fire control devices.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHS-NCM-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Speed NOTI•FIRE•NET™ (HS-NFN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Speed Network Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted-pair HS-NFN network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Node Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 ft depending on wiring conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransformer-coupled network isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCHS-4L, CHS-3L chassis, NCA-2, AFP-3030 CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded twisted-pair recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial fire alarm network communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.36 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eHS-NCM-W\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"550\" data-end=\"1199\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe HS-NCM-W is part of the NOTIFIER High-Speed NOTI•FIRE•NET™ communications module family, engineered for expanding fire alarm networks with high-bandwidth data transfer capabilities. It features dual network ports, transformer-coupled isolation, and support for Class A or Class B twisted-pair network configurations. The module is compatible with NOTIFIER network control panels, NCA-2 network annunciators, AFP-3030 systems, and CHS series chassis installations. Designed for commercial fire protection applications, the HS-NCM-W enables remote configuration access, firmware updates, and communication between multiple fire alarm system nodes.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1201\" data-end=\"1216\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1218\" data-end=\"2558\"\u003e\n\u003cli data-start=\"1218\" data-end=\"1328\"\u003eHigh-Speed Network Communication: Provides 12 Mbps data transfer for NOTIFIER NOTI•FIRE•NET™ HS-NFN systems.\u003c\/li\u003e\n\u003cli data-start=\"1329\" data-end=\"1459\"\u003eTwisted-Pair Network Support: Enables Class A and Class B communication wiring configurations using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1586\"\u003eDual Network Ports: Includes two independent ports for flexible connection between control panels, PCs, and network devices.\u003c\/li\u003e\n\u003cli data-start=\"1587\" data-end=\"1701\"\u003eRemote Programming Capability: Supports remote upload and download of panel configurations and firmware updates.\u003c\/li\u003e\n\u003cli data-start=\"1702\" data-end=\"1819\"\u003eRepeater Function: Operates as a regenerative repeater by default when not connected to a fire alarm control panel.\u003c\/li\u003e\n\u003cli data-start=\"1820\" data-end=\"1943\"\u003eElectrical Isolation: Uses transformer-coupled network connections to reduce interference and improve system reliability.\u003c\/li\u003e\n\u003cli data-start=\"1944\" data-end=\"2041\"\u003eGround Fault Detection: Provides switches for network troubleshooting and fault identification.\u003c\/li\u003e\n\u003cli data-start=\"2042\" data-end=\"2154\"\u003ePanel Compatibility: Designed for use with NOTIFIER AFP-3030, NCA-2, and compatible network control equipment.\u003c\/li\u003e\n\u003cli data-start=\"2155\" data-end=\"2270\"\u003eChassis Mounting Options: Supports installation in CHS-4L and CHS-3L chassis assemblies or direct panel mounting.\u003c\/li\u003e\n\u003cli data-start=\"2271\" data-end=\"2373\"\u003e24 VDC Operation: Uses standard fire alarm system power for integration into existing installations.\u003c\/li\u003e\n\u003cli data-start=\"2374\" data-end=\"2472\"\u003eCompact Design: Provides high-speed networking functionality in a space-efficient module format.\u003c\/li\u003e\n\u003cli data-start=\"2473\" data-end=\"2558\"\u003eFirmware V21 Generation: Supports Generation 1 HS-NCM module firmware requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2560\" data-end=\"2716\"\u003eThe HS-NCM-W delivers the reliability and precision required for high-speed fire alarm network communication and distributed life safety system integration.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676618496,"sku":"HS-NCM-W","price":7495.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ScreenShot2021-11-11at10.43.12AM_540x_2accdccb-8dae-4969-a2f9-9a96f152bdf0.png?v=1785530410"},{"product_id":"notifier-amps-24e-addressable-24vdc-power-supply-and-battery-charger","title":"Notifier AMPS-24E Addressable 24VDC Power Supply and Battery Charger","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Notifier AMPS-24E is an addressable power supply and battery charger designed to provide supervised 24 VDC power distribution for NOTIFIER fire alarm control systems. It supports up to three 24 VDC outputs, programmable charging capabilities, and integration with NFS-3030, NFS2-3030, and NCA-2 systems. The module is used to provide reliable system power, battery backup management, and auxiliary power for life safety installations.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAMPS-24E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Power Supply and Battery Charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFS-3030, NFS2-3030, NCA-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashScan® and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DC Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 0.5 A and 5 VDC @ 0.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 AH to 200 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable charging current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolated Signaling Line Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Type B connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC loss detection with delay reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrownout detection, battery supervision, charger monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrouble Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally open dry contacts or open-collector input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAB-4 Series, EQ Cabinet Series, BB-25, BB-100, BB-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm system power expansion and backup power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 5.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eAMPS-24E\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"487\" data-end=\"1117\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe AMPS-24E is part of the NOTIFIER addressable power supply family, developed for advanced fire alarm control panel installations requiring monitored power expansion. The unit provides isolated SLC communication, configurable battery charging from 7 AH to 200 AH batteries, and supervised auxiliary outputs for connected system devices. It is designed for installation in CAB-4 Series, EQ Series, and compatible battery backbox enclosures used with NOTIFIER control equipment. The power supply supports FlashScan® and CLIP operating modes, allowing flexible integration with existing and newer NOTIFIER fire alarm architectures.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1119\" data-end=\"1134\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1136\" data-end=\"2458\"\u003e\n\u003cli data-start=\"1136\" data-end=\"1272\"\u003eAddressable Power Supply: Communicates directly with NFS-3030 and NFS2-3030 fire alarm control panels for supervised power management.\u003c\/li\u003e\n\u003cli data-start=\"1273\" data-end=\"1397\"\u003eDual Protocol Support: Operates in FlashScan® or CLIP mode for compatibility with multiple NOTIFIER system configurations.\u003c\/li\u003e\n\u003cli data-start=\"1398\" data-end=\"1510\"\u003eMultiple 24 VDC Outputs: Provides up to three regulated 24 VDC power outputs for connected fire alarm devices.\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1615\"\u003eBattery Charging Capability: Supports selectable charging current for 7 AH to 200 AH backup batteries.\u003c\/li\u003e\n\u003cli data-start=\"1616\" data-end=\"1734\"\u003eIsolated SLC Interface: Provides electrically isolated signaling line communication for improved system reliability.\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1839\"\u003eAuxiliary Power Outputs: Includes secondary 24 VDC and 5 VDC auxiliary outputs for system peripherals.\u003c\/li\u003e\n\u003cli data-start=\"1840\" data-end=\"1945\"\u003eBattery Supervision: Continuously monitors battery condition and charger operation for fault reporting.\u003c\/li\u003e\n\u003cli data-start=\"1946\" data-end=\"2042\"\u003eAC Loss Monitoring: Detects AC power loss and supports configurable delay reporting functions.\u003c\/li\u003e\n\u003cli data-start=\"2043\" data-end=\"2144\"\u003eBrownout Detection: Identifies reduced input voltage conditions to help prevent unstable operation.\u003c\/li\u003e\n\u003cli data-start=\"2145\" data-end=\"2246\"\u003eUSB Programming Interface: Includes a Type B USB connector for configuring installation parameters.\u003c\/li\u003e\n\u003cli data-start=\"2247\" data-end=\"2356\"\u003eTrouble Bus Input: Supports normally open dry contacts and open-collector circuits for external monitoring.\u003c\/li\u003e\n\u003cli data-start=\"2357\" data-end=\"2458\"\u003eFlexible Mounting Options: Compatible with CAB-4, EQ Cabinet, BB-25, BB-100, and BB-200 enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2460\" data-end=\"2604\"\u003eThe AMPS-24E delivers the reliability and precision required for supervised fire alarm power distribution and emergency backup power management.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676585728,"sku":"AMPS-24E","price":1634.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/NF-PW08-0428.jpg?v=1785530410"},{"product_id":"notifier-pse-6-6a-remote-fire-alarm-power-supply-with-battery-charger","title":"Notifier PSE-6 6A Remote Fire Alarm Power Supply with Battery Charger","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Notifier PSE-6 is a 6-amp remote power supply with an integrated battery charger designed to provide regulated 24 VDC power for fire alarm notification appliance circuits and auxiliary devices. Compatible with virtually any 12V or 24V fire alarm control panel, the Notifier PSE-6 supports flexible NAC expansion, synchronized notification, and reliable backup power for commercial life safety systems.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSE-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Power Supply with Battery Charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output per Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 independently configurable circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B standard, Class A with optional ZNAC-PS module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResettable or non-resettable 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral charger for up to 33 Ah batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Battery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 7 Ah or two 18 Ah batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronization Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Sensor, Wheelock, Gentex, AMSECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Control Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 fully isolated programmable inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrouble Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo Form C normally closed trouble relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard DIP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 AWG (3.1 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocking heavy-gauge steel cabinet with powder-coated finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny UL 864 FACP using reverse-polarity NAC circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864, UL 1481, NFPA 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, ULC, FM, CSFM, FDNY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 12.0 lb (5.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003ePSE-6\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"450\" data-end=\"1240\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe PSE-6 is part of the NOTIFIER PS Series remote power supply family, developed to expand notification appliance circuits and auxiliary power capacity in fire alarm installations. It delivers up to 6 amps of regulated 24 VDC output and supports both Class A and Class B wiring configurations when used with the optional ZNAC-PS converter module. The unit includes an integrated battery charger capable of charging batteries up to 33 Ah and provides programmable outputs for notification appliances, smoke detectors, annunciators, door holders, and other system peripherals. Designed for dependable life safety applications, it offers configurable synchronization protocols, multiple diagnostic features, and compatibility with industry-standard reverse-polarity fire alarm control panels.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1184\" data-start=\"1169\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2131\" data-start=\"1186\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1264\" data-end=\"2495\"\u003e\n\u003cli data-start=\"1264\" data-end=\"1357\"\u003e6 Amp Power Output: Supplies up to 6 amps of regulated 24 VDC power for fire alarm devices.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1358\" data-end=\"1454\"\u003eMultiple Configurable Outputs: Supports up to five independently programmable output circuits.\u003c\/li\u003e\n\u003cli data-start=\"1455\" data-end=\"1559\"\u003eClass A or Class B Operation: Compatible with both wiring styles using the optional ZNAC-PS converter.\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1653\"\u003eIntegrated Battery Charger: Charges batteries up to 33 Ah with built-in charging circuitry.\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1756\"\u003eFlexible Auxiliary Power: Provides resettable or non-resettable 24 VDC power for peripheral devices.\u003c\/li\u003e\n\u003cli data-start=\"1757\" data-end=\"1859\"\u003eNAC Synchronization: Supports System Sensor, Wheelock, Gentex, and AMSECO synchronization protocols.\u003c\/li\u003e\n\u003cli data-start=\"1860\" data-end=\"1954\"\u003eCascading Capability: Allows connection of up to four power supplies within a single system.\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"2062\"\u003eProgrammable Input Circuits: Includes two fully isolated input\/control circuits assignable to any output.\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2168\"\u003eAdvanced Diagnostics: Features individual NAC status LEDs, trouble history, and AC trouble delay timer.\u003c\/li\u003e\n\u003cli data-start=\"2169\" data-end=\"2251\"\u003eDIP Switch Configuration: Complete setup without requiring software programming.\u003c\/li\u003e\n\u003cli data-start=\"2252\" data-end=\"2377\"\u003eHeavy-Duty Steel Enclosure: Locking corrosion-resistant cabinet with removable terminal blocks for simplified installation.\u003c\/li\u003e\n\u003cli data-start=\"2378\" data-end=\"2495\"\u003eWide FACP Compatibility: Operates with UL 864 listed fire alarm control panels using reverse-polarity NAC circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2497\" data-end=\"2654\"\u003eThe PSE-6 delivers the reliability and precision required for expanding notification appliance circuits and auxiliary power in commercial fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676651264,"sku":"PSE-6","price":815.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_e83e695e-8c7f-4f06-b0c7-ce31c04a59e9.webp?v=1785530410"},{"product_id":"notifier-slm-318-signaling-line-module-for-inspire-n16-fire-alarm-control-panels","title":"Notifier SLM-318 Signaling Line Module for INSPIRE N16 Fire Alarm Control Panels","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Notifier SLM-318 is a signaling line module designed to expand the capacity of NOTIFIER INSPIRE™ N16 Series Fire Alarm Control Panels by adding additional Signaling Line Circuits (SLCs). Factory-configured for FlashScan protocol with Self-Test detector support, the Notifier SLM-318 delivers reliable addressable communication and scalable system expansion for commercial fire alarm installations.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSLM-318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignaling Line Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNOTIFIER INSPIRE™ N16 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignaling Line Circuit Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Devices per Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 318 intelligent addressable devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Loop Cards per FACP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 (1 onboard plus up to 9 SLM-318 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashScan (factory default), CLIP (field configurable by license)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelf-Test Detector Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B, twisted unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum SLC Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,500 ft (3,810 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in degraded mode for increased survivability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL\/ULC Listed, FM Approved, CSFM, FDNY, OSHPD, IBC 2024 Seismic Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExpansion of addressable signaling line circuits for fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.4 lb (0.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSLM-318\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"1162\" data-start=\"446\"\u003eThe SLM-318 is an expansion module developed for the NOTIFIER INSPIRE™ N16 Series fire alarm control panel platform. It provides one additional Signaling Line Circuit capable of supporting up to 318 intelligent addressable devices while allowing the control panel to accommodate as many as ten loop cards in a single system. The module is supplied with FlashScan protocol enabled and supports NOTIFIER Self-Test intelligent detectors, while CLIP protocol can be activated through field licensing for compatible installations. Its plug-in design, built-in degraded mode, and long-distance communication capability make it suitable for large commercial, healthcare, educational, and industrial fire protection systems.\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1184\" data-start=\"1169\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2131\" data-start=\"1186\"\u003e\n\u003cli data-end=\"1302\" data-start=\"1186\"\u003eSupports Up to 318 Devices: Provides one SLC loop capable of connecting up to 318 intelligent addressable devices.\u003c\/li\u003e\n\u003cli data-end=\"1392\" data-start=\"1303\"\u003eN16 System Expansion: Allows the N16 Series FACP to support up to ten total loop cards.\u003c\/li\u003e\n\u003cli data-end=\"1473\" data-start=\"1393\"\u003eFlashScan Protocol: Factory programmed for high-speed FlashScan communication.\u003c\/li\u003e\n\u003cli data-end=\"1562\" data-start=\"1474\"\u003eCLIP Protocol Compatible: Individual modules can be field licensed for CLIP operation.\u003c\/li\u003e\n\u003cli data-end=\"1664\" data-start=\"1563\"\u003eSelf-Test Detector Support: Fully compatible with NOTIFIER Self-Test intelligent detection devices.\u003c\/li\u003e\n\u003cli data-end=\"1740\" data-start=\"1665\"\u003eLong SLC Distance: Supports Class B SLC wiring up to 12,500 ft (3,810 m).\u003c\/li\u003e\n\u003cli data-end=\"1826\" data-start=\"1741\"\u003eBuilt-In Degraded Mode: Maintains system survivability during communication faults.\u003c\/li\u003e\n\u003cli data-end=\"1904\" data-start=\"1827\"\u003ePlug-In Installation: Modular design simplifies installation and servicing.\u003c\/li\u003e\n\u003cli data-end=\"2010\" data-start=\"1905\"\u003eMixed Protocol Operation: Supports simultaneous FlashScan and CLIP cards within the same control panel.\u003c\/li\u003e\n\u003cli data-end=\"2131\" data-start=\"2011\"\u003eIndustry Certifications: Listed and approved by UL\/ULC, FM, CSFM, FDNY, OSHPD, and certified for seismic applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2282\" data-start=\"2133\"\u003eThe SLM-318 delivers the reliability and precision required for expanding addressable fire alarm communication loops in advanced life safety systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104676782336,"sku":"SLM-318","price":1009.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/SLM-318.jpg?v=1785530414"},{"product_id":"notifier-ubs-1b-metal-enclosure-with-solid-door-for-udact-2-remote-mounting","title":"Notifier UBS-1B Metal Enclosure with Solid Door for UDACT-2 Remote Mounting","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Notifier UBS-1B is a metal enclosure designed for the remote mounting of the UDACT-2 digital alarm communicator transmitter. It features a solid door construction that protects internal components while maintaining secure system integration. Built for durability, it provides a reliable housing solution for fire alarm communication modules.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUBS-1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal enclosure with solid door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUDACT-2 Digital Alarm Communicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid hinged door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePainted industrial finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm communication systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEquipment housing and physical protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eUBS-1B\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"919\" data-start=\"365\"\u003eThe UBS-1B is a remote mounting enclosure manufactured by Notifier for use with UDACT-2 communicators in fire alarm systems. It is constructed from heavy-duty metal to provide protection against environmental and physical damage in indoor installations. The enclosure includes a solid front door for secure access and helps maintain organized installation of communication equipment. Designed for compatibility with Notifier systems, it supports flexible system layouts where remote placement of communication modules is required.\u003c\/p\u003e\n\u003cp data-end=\"939\" data-start=\"921\"\u003e\u003cstrong data-end=\"937\" data-start=\"921\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1744\" data-start=\"940\"\u003e\n\u003cli data-end=\"1025\" data-start=\"940\"\u003eRemote Mounting Enclosure: Designed for off-panel installation of UDACT-2 modules\u003c\/li\u003e\n\u003cli data-end=\"1108\" data-start=\"1026\"\u003eSolid Door Design: Provides secure and protected access to internal components\u003c\/li\u003e\n\u003cli data-end=\"1197\" data-start=\"1109\"\u003eDurable Metal Construction: Ensures long-term reliability in fire alarm applications\u003c\/li\u003e\n\u003cli data-end=\"1279\" data-start=\"1198\"\u003eSystem Compatibility: Specifically designed for Notifier UDACT-2 communicator\u003c\/li\u003e\n\u003cli data-end=\"1354\" data-start=\"1280\"\u003eSecure Housing: Protects sensitive communication equipment from damage\u003c\/li\u003e\n\u003cli data-end=\"1427\" data-start=\"1355\"\u003eOrganized Installation: Supports clean and structured wiring layouts\u003c\/li\u003e\n\u003cli data-end=\"1505\" data-start=\"1428\"\u003eLockable Access (Typical): Enhances system security and restricted access\u003c\/li\u003e\n\u003cli data-end=\"1579\" data-start=\"1506\"\u003eCompact Design: Fits efficiently in various installation environments\u003c\/li\u003e\n\u003cli data-end=\"1654\" data-start=\"1580\"\u003eEasy Installation: Designed for straightforward wall or panel mounting\u003c\/li\u003e\n\u003cli data-end=\"1744\" data-start=\"1655\"\u003eFire System Integration: Ideal for use in life safety and alarm communication systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1870\" data-start=\"1746\"\u003eThe UBS-1B delivers the reliability and precision required for secure remote mounting of fire alarm communication equipment.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104771416320,"sku":"UBS-1B","price":270.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/UBS-1B.jpg?v=1785532562"},{"product_id":"notifier-chs-ps-chassis-for-acps-610e-mounting-in-cab-4-and-eq-series-enclosures","title":"Notifier CHS-PS Chassis for ACPS-610(E) Mounting in CAB-4 and EQ Series Enclosures","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Notifier CHS-PS is a mounting chassis designed specifically for installing ACPS-610(E) power supplies within CAB-4 and EQ Series enclosures. It provides a secure and organized platform for positioning power supply modules in multiple enclosure rows. Built for compatibility and ease of installation, it supports structured system layouts in fire alarm control systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCHS-PS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eACPS-610(E) Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAB-4, EQ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRow 1, Row 2, Row 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel\/Chassis Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModular mounting chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower supply integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eCHS-PS\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"919\" data-start=\"392\"\u003eThe CHS-PS is a chassis assembly manufactured by Notifier for use in fire alarm and life safety systems. It is engineered to accommodate the ACPS-610(E) auxiliary power supply, allowing installation in row 1, 2, or 3 of compatible CAB-4 and EQ Series cabinets. Constructed from durable materials, the chassis ensures stable mounting and proper alignment of system components. Its design supports modular system expansion and simplifies integration within complex fire alarm control panel configurations.\u003c\/p\u003e\n\u003cp data-end=\"939\" data-start=\"921\"\u003e\u003cstrong data-end=\"937\" data-start=\"921\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1693\" data-start=\"940\"\u003e\n\u003cli data-end=\"1035\" data-start=\"940\"\u003eDedicated Mounting Chassis: Designed specifically for ACPS-610(E) power supply installation\u003c\/li\u003e\n\u003cli data-end=\"1119\" data-start=\"1036\"\u003eMulti-Row Compatibility: Supports mounting in rows 1, 2, or 3 within enclosures\u003c\/li\u003e\n\u003cli data-end=\"1182\" data-start=\"1120\"\u003eEnclosure Compatibility: Fits CAB-4 and EQ Series cabinets\u003c\/li\u003e\n\u003cli data-end=\"1259\" data-start=\"1183\"\u003eSecure Component Mounting: Provides stable support for installed modules\u003c\/li\u003e\n\u003cli data-end=\"1331\" data-start=\"1260\"\u003eDurable Construction: Built for long-term use in fire alarm systems\u003c\/li\u003e\n\u003cli data-end=\"1403\" data-start=\"1332\"\u003eModular Design: Enables flexible system configuration and expansion\u003c\/li\u003e\n\u003cli data-end=\"1482\" data-start=\"1404\"\u003eOrganized Layout Support: Helps maintain clean and structured panel wiring\u003c\/li\u003e\n\u003cli data-end=\"1561\" data-start=\"1483\"\u003eEasy Installation: Simplifies mounting and alignment of power supply units\u003c\/li\u003e\n\u003cli data-end=\"1632\" data-start=\"1562\"\u003eOEM Compatibility: Designed to meet Notifier system specifications\u003c\/li\u003e\n\u003cli data-end=\"1693\" data-start=\"1633\"\u003eSpace Optimization: Efficiently utilizes enclosure space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1836\" data-start=\"1695\"\u003eThe CHS-PS delivers the reliability and precision required for secure mounting and integration of power supply modules in fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104772202752,"sku":"CHS-PS","price":171.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_4e4b3e00-3313-43dd-b452-3a1f1beb75de.webp?v=1785532583"},{"product_id":"nmm-100-10-notifier-ten-input-addressable-monitor-module","title":"NMM-100-10 | Notifier Ten-Input Addressable Monitor Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"18\" data-end=\"484\"\u003eThe Notifier NMM-100-10 is a ten-input monitor module designed to interface normally open contact devices with FireWarden series intelligent fire alarm control panels. It provides ten addressable Class B or five Class A initiating device circuits and reports supervised device status (normal, open, or short) to the panel. The NMM-100-10 features panel-controlled LED indicators and rotary address switches for flexible system configuration.\u003c\/p\u003e\n\u003ch3 data-start=\"486\" data-end=\"509\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNMM-100-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Monitor Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Class B or 5 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 mA (all addresses used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 mA (all LEDs ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum IDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum IDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum IDC Wiring Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum SLC Wiring Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 or 50 ohms (panel dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 to 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 85% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.8\" H × 5.8\" W × 1.25\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.76 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL S635, FM Approved, CSFM Approved, ULC S635 (A version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.76 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About NMM-100-10\u003c\/h4\u003e\n\u003cp\u003eThe NMM-100-10 is an addressable monitor module used in intelligent fire alarm systems to connect devices such as pull stations, waterflow switches, and security contacts to a FireWarden series control panel. The first module address is selectable from 01 to 90, with the remaining nine addresses automatically assigned sequentially, and up to two unused addresses may be disabled. Each point is independently supervised while sharing a common SLC input and supervisory supply. The module supports both Class A and Class B wiring configurations and includes removable plug-in terminal blocks for simplified installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTen Addressable Inputs: Supports ten Class B or five Class A initiating device circuits.\u003c\/li\u003e\n\u003cli\u003eSequential Address Assignment: First address set via rotary switches; remaining nine auto-assign sequentially.\u003c\/li\u003e\n\u003cli\u003eSupervised Monitoring: Reports normal, open, and short circuit conditions to the control panel.\u003c\/li\u003e\n\u003cli\u003ePanel-Controlled LED Indicators: Green LEDs per point with blink, latch on, or latch off control.\u003c\/li\u003e\n\u003cli\u003eClass A or Class B Operation: Configurable wiring by removing shunt for Class A.\u003c\/li\u003e\n\u003cli\u003eRemovable Terminal Blocks: Accepts 12–18 AWG wiring for simplified installation and servicing.\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting Options: Compatible with CHS-6 chassis, BB-25 cabinet, and BB-XP cabinet.\u003c\/li\u003e\n\u003cli\u003eAgency Approved: UL Listed (S635), FM Approved, CSFM Approved, ULC Listed (NMM-100-10A).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NMM-100-10 delivers the reliability and precision required for multi-point monitoring in intelligent fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104818176256,"sku":"NMM-100-10","price":2244.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/hon-ba-fire-monitor-multi-module-center.jpg?v=1785533707"},{"product_id":"2ccpa2a1c2b-honeywell-grabwire-safety-microswitch-dpst-nonc-500-ft-cable-span","title":"2CCPA2A1C2B | Honeywell Grabwire Safety Microswitch, DPST-NO\/NC, 500 ft Cable Span","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"474\" data-start=\"21\"\u003eThe Honeywell 2CCPA2A1C2B is a grabwire safety microswitch designed to provide emergency stop and line-pull protection in industrial environments. This device features dual DPST normally open and normally closed contact configurations for reliable circuit interruption. It is commonly used in conveyor systems and machinery where long-distance cable-actuated safety control is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable and Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCPA2A1C2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Cable\/Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrabwire safety microswitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPST-NO \/ DPST-NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Span Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency stop \/ safety interlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.563 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 2CCPA2A1C2B\u003c\/h4\u003e\n\u003cp data-end=\"1065\" data-start=\"503\"\u003eThe 2CCPA2A1C2B is part of Honeywell’s industrial safety switch lineup engineered for cable-operated emergency stop applications. It is constructed with a durable enclosure and internal switching mechanism to ensure dependable performance under continuous mechanical operation. The switch is compatible with standard 24 VDC and 120 VAC control circuits and integrates easily into safety relay and machine control systems. Typical usage includes material handling lines, packaging equipment, and production conveyors where immediate shutdown via a pull-cable mechanism is essential for personnel safety.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGrabwire safety switch: Enables emergency stop activation via pull-cable operation.\u003c\/li\u003e\n\u003cli\u003eDual contact configuration: Provides both DPST normally open and DPST normally closed outputs.\u003c\/li\u003e\n\u003cli\u003eLong cable span support: Accommodates cable runs up to 500 feet for extended conveyor systems.\u003c\/li\u003e\n\u003cli\u003eHigh current handling: Supports up to 6 A AC and 2.8 A DC switching capacity.\u003c\/li\u003e\n\u003cli\u003eMulti-voltage compatibility: Rated for 120 VAC and 24 VDC control circuits.\u003c\/li\u003e\n\u003cli\u003eIndustrial microswitch design: Built for reliable mechanical and electrical operation.\u003c\/li\u003e\n\u003cli\u003eRoHS compliant construction: Meets environmental and material compliance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 2CCPA2A1C2B delivers the reliability and precision required for emergency stop and safety monitoring in industrial cable-actuated protection systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104940302592,"sku":"2CCPA2A1C2B","price":620.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_3959acc7-628f-466a-919c-bc643a127f39.webp?v=1785536665"},{"product_id":"51401583-100-honeywell-measurex-tdc-3000-enhanced-process-network-interface-module","title":"51401583-100 | Honeywell Measurex TDC 3000 Enhanced Process Network Interface module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"474\"\u003eThe Honeywell 51401583-100 is an Enhanced Process Network Interface (EPNI) module designed for communication bridging within Honeywell distributed control systems. This network interface module enables data exchange between Local Control Networks (LCN) and Universal Control Networks (UCN). It is used in legacy Honeywell TDC 3000 environments requiring reliable network integration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Measurex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistributed Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51401583-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnhanced Process Network Interface (EPNI) board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork Interface Module (NIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBridges LCN and UCN networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternate Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51401583100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial DCS network communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 51401583-100\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003eThe 51401583-100 is part of the Honeywell Measurex network interface hardware used in TDC 3000 distributed control systems. It is built as a dedicated interface board that manages protocol translation and communication routing between different Honeywell control networks. The module is compatible with Honeywell DCS architectures that utilize both LCN and UCN segments. Typical usage includes industrial process plants where coordinated communication between supervisory and control-level networks is required for stable system operation.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnhanced Process Network Interface: Provides communication bridging between Honeywell control networks.\u003c\/li\u003e\n\u003cli\u003eLCN to UCN connectivity: Enables data exchange between Local and Universal Control Networks.\u003c\/li\u003e\n\u003cli\u003eTDC 3000 compatibility: Designed specifically for Honeywell TDC 3000 distributed control systems.\u003c\/li\u003e\n\u003cli\u003eDedicated interface board: Performs protocol handling without additional processing load on controllers.\u003c\/li\u003e\n\u003cli\u003eLegacy system support: Maintains communication capability in established Honeywell DCS installations.\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade construction: Built for continuous operation in process control environments.\u003c\/li\u003e\n\u003cli\u003eMeasurex hardware platform: Manufactured under Honeywell Measurex specifications for network reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 51401583-100 delivers the reliability and precision required for stable network communication within Honeywell distributed control systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104940368128,"sku":"51401583-100","price":3214.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_e15eb751-d4e1-41d5-8656-d00d8301bbcf.webp?v=1785536669"},{"product_id":"dr45at-1000-00-000-0-000p00-0-honeywell-truline-12-inch-circular-chart-recorder","title":"DR45AT-1000-00-000-0-000P00-0 | Honeywell Truline 12-Inch Circular Chart Recorder","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"474\"\u003eThe Honeywell DR45AT-1000-00-000-0-000P00-0 is a circular chart recorder designed for accurate recording of process variables in industrial control systems. This Truline-series recorder supports multiple input types, including thermocouples, RTDs, voltage, and current signals. It is used in applications requiring continuous, reliable visual documentation of process conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eData Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDR45AT-1000-00-000-0-000P00-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChart Recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruline DR45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular chart recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChart Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-inch circular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, 0–5 VDC, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecording Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous analog recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess monitoring and documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About DR45AT-1000-00-000-0-000P00-0\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003eThe DR45AT-1000-00-000-0-000P00-0 is part of Honeywell’s Truline DR45 series of circular chart recorders developed for precision data recording. It features a robust panel-mounted enclosure with a 12-inch circular chart format for clear trend visualization. The recorder is compatible with a wide range of field-selectable input signals, allowing integration into diverse process control environments. Typical usage includes industrial plants, laboratories, and utilities where permanent process records and compliance documentation are required.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTruline DR45 series: Designed for industrial-grade circular chart recording applications.\u003c\/li\u003e\n\u003cli\u003e12-inch circular chart: Provides clear, easy-to-read process trend documentation.\u003c\/li\u003e\n\u003cli\u003eMulti-signal input support: Accepts thermocouple, RTD, 0–5 VDC, and 4–20 mA inputs.\u003c\/li\u003e\n\u003cli\u003eField-selectable input configuration: Allows flexible setup without hardware changes.\u003c\/li\u003e\n\u003cli\u003ePanel-mount design: Enables secure installation in control cabinets and panels.\u003c\/li\u003e\n\u003cli\u003eContinuous data recording: Produces permanent visual records of process conditions.\u003c\/li\u003e\n\u003cli\u003eIndustrial construction: Built for reliable operation in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DR45AT-1000-00-000-0-000P00-0 delivers the reliability and precision required for continuous process monitoring and data recording in industrial control systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104940433664,"sku":"DR45AT-1000-00-000-0-000P00-0","price":3967.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Honeywell-DR4500-Truline-360_a8c6aa35-133c-4838-adcc-773f8f87cf25.jpg?v=1785536670"},{"product_id":"m436a1116-honeywell-spring-return-hvac-damper-actuator-20-in-lb-120-vac","title":"M436A1116 | Honeywell Spring-Return HVAC Damper Actuator, 20 in-lb, 120 VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"474\"\u003eThe Honeywell M436A1116 is a spring-return damper actuator designed to control air dampers in HVAC systems using reliable electromechanical operation. This actuator delivers 20 in-lb of torque and operates on 120 VAC to provide precise damper positioning during normal operation and automatic return on power loss. It is commonly used in ventilation and air-handling applications requiring dependable airflow control.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM436A1116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHVAC Actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDamper actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTorque Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 in-lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHexagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Shaft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM436A1090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHVAC damper and airflow control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.95 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eM436A1116\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003eThe M436A1116 is part of Honeywell’s M436 series of damper actuators engineered for remote-mounted HVAC control applications. It features a robust double-ended output shaft with a hexagonal profile to support flexible mechanical linkage configurations. The actuator is compatible with standard HVAC damper assemblies and integrates easily with building control systems using SPST switching. Typical usage includes air handlers, zone dampers, and ventilation systems where spring-return safety and consistent torque output are required.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpring-return operation: Automatically returns the damper to a fail-safe position upon power loss.\u003c\/li\u003e\n\u003cli\u003e20 in-lb torque output: Provides sufficient force for reliable damper movement.\u003c\/li\u003e\n\u003cli\u003e120 VAC power supply: Designed for standard HVAC electrical systems.\u003c\/li\u003e\n\u003cli\u003eRemote mount design: Allows flexible installation away from the damper shaft location.\u003c\/li\u003e\n\u003cli\u003eDouble-ended shaft: Supports multiple linkage and mounting configurations.\u003c\/li\u003e\n\u003cli\u003eHexagonal shaft type: Ensures secure mechanical coupling to dampers.\u003c\/li\u003e\n\u003cli\u003eSPST auxiliary switch: Enables position indication or interlock control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe M436A1116 delivers the reliability and precision required for safe and consistent damper control in HVAC airflow management systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104941646080,"sku":"M436A1116","price":1046.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l960_7395a214-aa28-43c8-bc1e-4786733c21e6.webp?v=1785536699"},{"product_id":"st7800a1039-honeywell-7800-series-remote-keyboard-display-module-for-burner-control","title":"ST7800A1039 | Honeywell 7800 Series Remote Keyboard Display Module for Burner Control","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"474\"\u003eThe Honeywell ST7800A1039 is a remote keyboard display module designed for monitoring and interaction with Honeywell 7800 Series burner control systems. This unit provides real-time operational status, fault codes, and diagnostic information to support safe burner management. It is commonly used in commercial and industrial combustion applications requiring remote system visibility.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eST7800A1039\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Control Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7800 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeyboard display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote monitoring and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital alphanumeric display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell 7800 Series controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner system monitoring and troubleshooting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.50 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About ST7800A1039\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003eThe ST7800A1039 is part of Honeywell’s 7800 Series burner management platform, engineered to enhance system diagnostics and operator interface capabilities. It features a compact, panel-mounted design with a digital display and keypad for navigation and data access. The module is fully compatible with Honeywell 7800 Series primary safety controls and relay modules. Typical usage includes boilers, furnaces, and process heating equipment where remote monitoring, troubleshooting, and system status review are required.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e7800 Series compatibility: Designed for use with Honeywell 7800 Series burner control systems.\u003c\/li\u003e\n\u003cli\u003eRemote display interface: Provides operational status, messages, and fault codes remotely.\u003c\/li\u003e\n\u003cli\u003eIntegrated keypad: Allows navigation through system data and diagnostic menus.\u003c\/li\u003e\n\u003cli\u003eReal-time system feedback: Displays burner sequence and safety status information.\u003c\/li\u003e\n\u003cli\u003eCompact module design: Suitable for control panel or door-mounted installation.\u003c\/li\u003e\n\u003cli\u003eDiagnostic support: Assists maintenance personnel with fault identification and system review.\u003c\/li\u003e\n\u003cli\u003eLow-voltage interface: Designed for safe interaction with burner management electronics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ST7800A1039 delivers the reliability and precision required for effective monitoring and diagnostics in burner management systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104942399744,"sku":"ST7800A1039","price":270.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-01-28_20.16.01.png?v=1785536709"},{"product_id":"l404f1102-honeywell-pressuretrol-pressure-control-10-150-psi-120240-vac","title":"L404F1102 | Honeywell Pressuretrol Pressure Control, 10–150 PSI, 120\/240 VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"198\" data-end=\"559\"\u003eThe Honeywell L404F1102 is a pressure control device designed to regulate and monitor pressure in industrial and commercial systems. This pressuretrol controller operates within a 10 to 150 PSI range and provides snap-action switching for precise pressure control. It is commonly used in applications where reliable pressure-based equipment control is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControls \u0026amp; Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL404F1102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressuretrol controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–150 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–22 PSI adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Action\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSnap action\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP7810C-1018, L404F1342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure regulation and system control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.90 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About L404F1102\u003c\/h4\u003e\n\u003cp data-start=\"595\" data-end=\"1101\"\u003eThe L404F1102 is part of Honeywell’s L404 pressure control series engineered for dependable pressure regulation in mechanical systems. It features a robust mechanical design with a 1\/4-inch NPT pressure connection for secure installation. The controller is compatible with 120\/240 VAC control circuits and integrates easily into existing pressure-managed systems. Typical usage includes boilers, compressors, and industrial process equipment where accurate pressure cut-in and cut-out control is essential.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWide pressure range: Operates from 10 to 150 PSI for versatile system compatibility.\u003c\/li\u003e\n\u003cli\u003eSnap-action switching: Provides fast and reliable electrical response to pressure changes.\u003c\/li\u003e\n\u003cli\u003eAdjustable differential: Supports differential pressure settings from 10 to 22 PSI.\u003c\/li\u003e\n\u003cli\u003eStandard pressure connection: Uses a 1\/4-inch NPT fitting for secure system integration.\u003c\/li\u003e\n\u003cli\u003eDual-voltage operation: Compatible with both 120 VAC and 240 VAC control circuits.\u003c\/li\u003e\n\u003cli\u003eMechanical pressure sensing: Ensures consistent operation without electronic components.\u003c\/li\u003e\n\u003cli\u003eDirect replacement capability: Replaces legacy Honeywell models P7810C-1018 and L404F1342.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe L404F1102 delivers the reliability and precision required for dependable pressure control in industrial and HVAC systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104942563584,"sku":"L404F1102","price":439.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-01-28_20.10.04.png?v=1785536712"},{"product_id":"eg1033aa01-honeywell-flame-safety-amplifier-24-28-vdc-high-sensitivity-flame-detection","title":"EG1033AA01 | Honeywell Flame Safety Amplifier, 24–28 VDC, High-Sensitivity Flame Detection","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"474\"\u003eThe Honeywell EG1033AA01 is a flame safety amplifier designed to detect flame presence and flame loss in industrial combustion control systems. Operating on 24 to 28 VDC, it provides rapid response times to ensure safe burner operation. This unit is used in flame safeguard systems where fast and accurate flame monitoring is critical.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame Safety Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEG1033AA01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame Safety Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame curtain amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Present Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 seconds (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Loss Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 seconds (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner and combustion flame monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About EG1033AA01\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003eThe EG1033AA01 is part of Honeywell’s flame safety product range developed for reliable flame detection in burner management systems. It is built with high-sensitivity electronics that allow quick recognition of flame presence and rapid shutdown on flame failure. The amplifier is compatible with Honeywell flame safeguard controls and associated flame sensors used in industrial and commercial combustion equipment. Typical usage includes boilers, furnaces, and process heating systems that require dependable flame monitoring and safety compliance.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame safety amplifier: Processes flame signal input for burner safety control systems.\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity detection: Provides fast flame-present recognition with a typical response of 0.1 seconds.\u003c\/li\u003e\n\u003cli\u003eRapid flame loss response: Detects flame failure within 0.2 seconds maximum.\u003c\/li\u003e\n\u003cli\u003eLow-voltage operation: Operates on 24 to 28 VDC for control system compatibility.\u003c\/li\u003e\n\u003cli\u003eFlame curtain technology: Designed for stable and accurate flame signal amplification.\u003c\/li\u003e\n\u003cli\u003eCompact module design: Suitable for integration into flame safeguard control panels.\u003c\/li\u003e\n\u003cli\u003eSafety-focused performance: Supports rapid system shutdown during flame failure conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EG1033AA01 delivers the reliability and precision required for high-speed flame detection in industrial flame safety systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104942629120,"sku":"EG1033AA01","price":7183.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_a783824b-653a-4d96-a486-bafbf588d21e.webp?v=1785536715"},{"product_id":"rm7840e1016-honeywell-7800-series-burner-control-relay-module-with-interrupted-pilot","title":"RM7840E1016 | Honeywell 7800 Series Burner Control Relay Module with Interrupted Pilot","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"474\"\u003eThe Honeywell RM7840E1016 is a burner control relay module designed for precise flame safeguard and sequencing control in commercial and industrial combustion systems. This unit manages ignition, pilot operation, and purge timing to ensure safe burner startup and shutdown. It is commonly used in gas-fired heating applications requiring reliable programmed control.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM7840E1016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7800 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner control relay module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterrupted pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecond Stage Pilot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterrupted pilot valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow Check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarly Spark Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePost Purge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition Sequence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-ignition enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtective Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDust cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial and industrial burner systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.88 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eRM7840E1016\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003eThe RM7840E1016 is part of Honeywell’s 7800 Series burner control platform, engineered for advanced flame safety management. It features a modular relay design with integrated programming logic and a protective dust cover for control panel installation. The unit is compatible with Honeywell flame detectors, amplifiers, and accessories used in 7800 Series burner management systems. Typical usage includes boilers, furnaces, and process heaters where controlled ignition sequencing, airflow verification, and safety interlocks are required.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e7800 Series relay module: Designed for use within Honeywell 7800 Series burner control systems.\u003c\/li\u003e\n\u003cli\u003eInterrupted pilot control: Supports interrupted pilot and second-stage pilot valve operation.\u003c\/li\u003e\n\u003cli\u003eUser-selectable airflow check: Allows configurable airflow verification during startup.\u003c\/li\u003e\n\u003cli\u003eEarly spark termination: Provides 5-second early spark termination for controlled ignition.\u003c\/li\u003e\n\u003cli\u003eTimed post-purge: Includes a fixed 15-second post-purge cycle for safe shutdown.\u003c\/li\u003e\n\u003cli\u003ePre-ignition sequence: Ensures proper system readiness before fuel ignition.\u003c\/li\u003e\n\u003cli\u003eDust cover protection: Helps protect internal components in control cabinet environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RM7840E1016 delivers the reliability and precision required for safe burner sequencing and flame safeguard control in HVAC combustion systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104942694656,"sku":"RM7840E1016","price":6250.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-01-28_19.39.51.png?v=1785536717"},{"product_id":"nbg-12lx-notifier-addressable-dual-action-manual-fire-alarm-pull-station","title":"NBG-12LX | Notifier Addressable Dual-Action Manual Fire Alarm Pull Station","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"413\" data-start=\"117\"\u003eThe Notifier NBG-12LX is an addressable manual fire alarm pull station designed for reliable emergency signaling in commercial fire alarm systems. This dual-action device provides secure manual alarm initiation and integrates directly with Notifier intelligent fire alarm control panels. Built for indoor use, the NBG-12LX ensures dependable operation in regulated life safety environments.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eFire Alarm Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eNBG-12LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eManual Pull Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eNBG-12 Series: Fire Alarm Pull Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum SLC Loop Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e375 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eDual-Action, Key Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eProgramming Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eRotary Dials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003eIndoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e10% to 93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e5.5 in (H) × 4 in (W) × 2 in (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4337%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.347%; height: 19.5938px;\"\u003e0.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About NBG-12LX\u003c\/h4\u003e\n\u003cp\u003eThe NBG-12LX is an addressable manual pull station within the Notifier NBG-12 Series, engineered for intelligent fire alarm applications. It features a durable polycarbonate housing designed to withstand frequent use in commercial and institutional buildings. The device connects to an addressable SLC loop and supports rotary dial addressing for straightforward installation and system configuration. Designed for indoor environments, it operates reliably across a wide temperature and humidity range while maintaining low standby current consumption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable SLC Interface: Communicates directly with compatible Notifier fire alarm control panels for precise device identification.\u003c\/li\u003e\n\u003cli\u003eDual-Action Activation: Requires two deliberate actions to initiate an alarm, reducing accidental activations.\u003c\/li\u003e\n\u003cli\u003eRotary Dial Addressing: Simplifies device addressing without the need for additional programming tools.\u003c\/li\u003e\n\u003cli\u003eKey Reset Operation: Allows authorized personnel to reset the station quickly after activation.\u003c\/li\u003e\n\u003cli\u003eDurable Polycarbonate Construction: Provides long-term reliability and resistance to wear in indoor installations.\u003c\/li\u003e\n\u003cli\u003eLow Standby Current Draw: Optimized for energy-efficient operation on addressable loops.\u003c\/li\u003e\n\u003cli\u003eWide Environmental Tolerance: Operates consistently across specified temperature and humidity ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NBG-12LX delivers the reliability and precision required for addressable fire alarm manual activation points in life safety systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49104945938688,"sku":"NBG-12LX","price":179.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_1cf4e42c-dcfe-4477-8a84-6ef08683879a.webp?v=1785536771"},{"product_id":"np-200t-notifier-photoelectric-smoke-detector-with-135f-heat-sensor-flashscan-addressable","title":"NP-200T | Notifier Photoelectric Smoke Detector with 135°F Heat Sensor, FlashScan Addressable","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier NP-200T is an intelligent plug-in photoelectric smoke detector with an integrated 135°F (57°C) fixed-temperature heat sensor. Designed exclusively for FireWarden Series addressable panels, it offers advanced sensing performance and point-ID identification for precise fire detection.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNP-200T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent plug-in photoelectric with 135°F heat sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotoelectric light-scattering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Sensor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e135°F (57°C), fixed temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashScan intelligent communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary decimal address switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireWarden addressable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual, bi-color status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Bases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB300-6, B501-White, B200S-WH, B200SR-WH, B200S-LF-WH, B200SR-LF-WH, B224RB-WH, B224BI-WH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR300, RA100Z(A) remote LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor dry locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-profile plug-in base mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoke and fixed-temperature fire detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive replacement for NP-100 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 lbs (typical detector weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eNP-200T\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe NP-200T is part of Notifier’s NP-200 Series, a family of next-generation photoelectric detectors engineered as direct replacements for the NP-100 Series. Its redesigned optical chamber improves sensitivity to a wide range of slow- and fast-burning fire types, meeting modern code requirements. The detector communicates using the FlashScan protocol, enabling rapid polling and precise system response while allowing address selection via rotary decimal switches. With a low-profile housing and compatibility with multiple intelligent bases, the NP-200T is suited for both new installations and system upgrades in commercial fire-protection environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhotoelectric Smoke Detection: Enhanced optical chamber for improved response to various combustion sources.\u003c\/li\u003e\n\u003cli\u003eBuilt-In 135°F Heat Sensor: Integrates fixed-temperature thermal detection for multi-criteria fire protection.\u003c\/li\u003e\n\u003cli\u003eFlashScan Intelligent Protocol: Provides fast communication, reduced latency, and reliable detector supervision.\u003c\/li\u003e\n\u003cli\u003ePoint-ID Addressing: Rotary decimal address switches allow precise location identification for emergency personnel.\u003c\/li\u003e\n\u003cli\u003eModern Low-Profile Design: Sleek aesthetic suitable for commercial and institutional environments.\u003c\/li\u003e\n\u003cli\u003eDual Status LEDs: Provides local visual indication of power, alarm, and diagnostic conditions.\u003c\/li\u003e\n\u003cli\u003eCompatible with FireWarden FACPs: Designed exclusively for Notifier addressable control panels using FlashScan.\u003c\/li\u003e\n\u003cli\u003eSupports Multiple Mounting Bases: Works with sounder bases, relay bases, isolator bases, and low-profile standard bases.\u003c\/li\u003e\n\u003cli\u003eRemote LED Annunciator Support: Allows visual status indication from a remote location for concealed or high-ceiling installations.\u003c\/li\u003e\n\u003cli\u003eDirect Replacement for NP-100 Series: Simplifies upgrades without major system redesign.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NP-200T delivers the reliability and precision required for modern addressable fire-detection systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105077076224,"sku":"NP-200T","price":142.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_4840387c-95fa-42ed-87f4-b1da875d1ac8.webp?v=1785539558"},{"product_id":"sib-2048a-notifier-serial-interface-board-for-m2-and-7-series-fire-alarm-systems","title":"SIB-2048A | Notifier Serial Interface Board for M2 and 7-Series Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier SIB-2048A Serial Interface Board is a communication module designed to enable data exchange between control units and peripheral devices in M2 and 7-Series fire alarm systems. It provides reliable serial communication and includes two optical channels for secure, high-speed data transmission.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eSIB-2048A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eSerial Interface Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eM2 and 7-Series Fire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eSerial Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eDual Optical Serial Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eData Transmission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eHigh-Speed, Error-Checked Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eInternal Circuit Board Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eSupplied from Host System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eOptical Serial Links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eControl and Peripheral Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eContinuous Communication Integrity Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eDurable Printed Circuit Board (PCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 39.2px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 39.2px;\"\u003eIndoor, Controlled Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003eUL Listed Fire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.7908%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8945%; height: 19.6px;\"\u003e0.80 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSIB-2048A\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SIB-2048A Serial Interface Board by Notifier serves as a vital communication link within M2 and 7-Series fire alarm systems, managing data transmission between control modules, peripheral units, and external communication networks. Equipped with two optical channels, it ensures isolated, interference-free serial communication, enhancing the reliability and speed of system data exchange. The module integrates directly into system control assemblies, providing robust performance and supervision for continuous communication integrity. Compact and durable, the SIB-2048A supports system expansion and modernization while maintaining full compliance with UL fire safety standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Optical Communication Channels: Provides two optically isolated serial links for high-speed, interference-free communication.\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Designed for use in Notifier M2 and 7-Series systems to ensure seamless data connectivity between panels and modules.\u003c\/li\u003e\n\u003cli\u003eReliable Data Transmission: Incorporates error-checking and supervision features for continuous communication integrity.\u003c\/li\u003e\n\u003cli\u003eCompact PCB Assembly: Easily mounts within control enclosures without requiring additional chassis hardware.\u003c\/li\u003e\n\u003cli\u003eOptical Isolation: Prevents electrical noise and cross-system interference for stable performance.\u003c\/li\u003e\n\u003cli\u003ePlug-and-Play Installation: Simplifies system setup and maintenance within Notifier network architectures.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Built with high-quality PCB materials for long-term operational reliability.\u003c\/li\u003e\n\u003cli\u003eUL Compliance: Meets industry standards for fire alarm communication components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SIB-2048A delivers the reliability and precision required for secure serial communication and control synchronization within Notifier’s advanced fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105143759104,"sku":"SIB-2048A","price":683.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/1a71d2521393449a8f672f01174cc314.jpg?v=1785541217"},{"product_id":"nca-2-notifier-network-control-annunciator-640-character-display","title":"NCA-2 | Notifier Network Control Annunciator 640-Character Display","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier NCA-2 Network Control Annunciator is a second-generation control and display module for NOTI•FIRE•NET networks. It provides 640-character LCD annunciation and full network-wide system control for ONYX® Series fire alarm panels, enabling centralized monitoring, command, and event management.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eNCA-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eNetwork Control Annunciator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003e640-Character Backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eKey Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eQWERTY Keypad, Soft Keys, and Fixed Function Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eNFS2-3030, NFS-3030, NFS-320, NFS-640, NFS2-640, and DVC Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eNOTI•FIRE•NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eHistory Buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003e1000 Alarm Events, 4000 System Events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eControl Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eAcknowledge, Silence, Reset, Enable\/Disable, Lamp Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eOnline Programming and Alter-Status Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eReports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003ePrintable Programming and History Reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eEvent Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eFiltered Reports by Alarm, Trouble, Supervisory, Security, or Time Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eUser Access\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eOne Master and Nine User Password Levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eAdditional Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eWalk-Test Program, Timer Controls, HVAC\/Smoke Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eNFPA FSCS, Canadian ULC Display Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eControl Cabinet or Wall-Mount Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003eSupplied via Network Node or External Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.6006%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 78.2663%;\"\u003e2.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eNCA-2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe NCA-2 is a comprehensive network annunciator and control interface for NOTIFIER’s NOTI•FIRE•NET systems, designed for centralized system operation and monitoring. It features a 640-character backlit LCD with an intuitive QWERTY keypad, programmable soft keys, and dedicated hard keys for critical control functions. Compatible with ONYX® Series panels such as the NFS2-3030 and NFS-640, it can serve as either a network-wide control point or the primary display for displayless nodes. The NCA-2 allows operators to perform event acknowledgment, silence, reset, and enable\/disable functions, while providing detailed event history, alarm tracking, and report generation. Its programmable user access levels and compliance with NFPA and ULC requirements make it a robust and secure solution for large-scale fire alarm networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Resolution Display: 640-character backlit LCD provides clear, comprehensive system information and event details.\u003c\/li\u003e\n\u003cli\u003eFull Network Control: Enables global command of alarms, silencing, resets, and system enable\/disable across all ONYX Series nodes.\u003c\/li\u003e\n\u003cli\u003eAdvanced Event Management: Stores 1000 alarm and 4000 system events, filterable by type or time for efficient review.\u003c\/li\u003e\n\u003cli\u003eIntegrated QWERTY Interface: Offers intuitive programming and operation with interactive soft and hard key navigation.\u003c\/li\u003e\n\u003cli\u003eProgrammable Access Control: Includes 10 user levels with password protection and customizable permissions.\u003c\/li\u003e\n\u003cli\u003eComprehensive Reporting: Supports real-time history and configuration printing for system documentation.\u003c\/li\u003e\n\u003cli\u003eHVAC and Smoke Control Support: Meets NFPA Firefighter Smoke Control Station (FSCS) requirements.\u003c\/li\u003e\n\u003cli\u003eULC and NFPA Compliant: Certified for use in fire detection and life-safety network applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NCA-2 delivers the reliability and precision required for centralized control, monitoring, and event management across Notifier’s networked fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105143824640,"sku":"NCA-2","price":2675.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Notifier-NCA-2-1200x900.jpg?v=1785541219"},{"product_id":"aa-100-notifier-100w-audio-amplifier-707vrms-output-for-voice-evacuation-systems","title":"AA-100 | Notifier 100W Audio Amplifier, 70.7Vrms Output for Voice Evacuation Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier AA-100 Audio Amplifier delivers 100 watts of 70.7 Vrms output power for integrated voice evacuation systems. Designed for use with Notifier’s AMG-1 and DVC Digital Voice Command Series, it provides high-efficiency audio performance with full amplifier supervision and automatic backup capabilities.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eAA-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eAudio Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003e100 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003e70.7 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eOptimized for Voice and Evacuation Tone Transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eAmplifier Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eHigh-Efficiency Switched Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eAMG-1, DVC, DVC-AO Analog Audio Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eBackup Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eAutomatic Backup Amplifier Switch-Over\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eBackup Tone Generator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eBuilt-In (Slow Whoop \/ High-Low)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eStandby Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eLow-Power Battery Preservation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eIntegral with Brownout and Battery Switch-Over Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003e19” Rack or Notifier CAB-3\/CAB-4\/EQ Enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003ePlug-In Terminal Strips and Cable Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eAmplifier and Output Line Supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003ePower-Limiting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003eUL and NFPA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eInput Voltage Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003e120 VAC Standard (240 VAC for AA-100E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eLevel Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003e10-Position Adjust with LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003e4.50 × 19.00 × 7.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6036%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2632%;\"\u003e16.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eAA-100\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe AA-100 is part of Notifier’s AA Series of high-performance audio amplifiers, providing reliable power amplification for emergency voice evacuation and paging systems. It outputs up to 100 watts of audio power at 70.7 Vrms and supports dual outputs that can be combined for full-rated operation. The amplifier incorporates power-switching technology for reduced heat output, ensuring long-term stability and energy efficiency. Integrated supervision, automatic backup amplifier switching, and a built-in backup tone generator provide redundancy and fault tolerance critical to life safety applications. Designed for seamless use with AMG-1 and DVC-AO systems, the AA-100 ensures clear, consistent communication across large-scale installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Power Audio Output: Provides 100 watts of regulated 70.7 Vrms audio for fire alarm and voice evacuation systems.\u003c\/li\u003e\n\u003cli\u003eDual Channel Operation: Supports dual outputs with combined load not exceeding 100 watts for system flexibility.\u003c\/li\u003e\n\u003cli\u003eAdvanced Supervision: Includes amplifier, output line, and backup supervision for continuous fault monitoring.\u003c\/li\u003e\n\u003cli\u003eAutomatic Backup Tone Generation: Features internal slow whoop or high\/low tone for emergency redundancy.\u003c\/li\u003e\n\u003cli\u003eLow Standby Power Mode: Minimizes battery drain while maintaining system readiness.\u003c\/li\u003e\n\u003cli\u003eEfficient Power Switching: Reduces heat buildup, allowing compact installation and improved energy use.\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting Options: Fits 19-inch equipment racks or standard Notifier cabinets (CAB-3, CAB-4, EQ).\u003c\/li\u003e\n\u003cli\u003eUser-Friendly Controls: Includes a 10-position level adjust, LED indicators, and plug-in connectors for simple setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AA-100 delivers the reliability and precision required for dependable emergency voice communication in Notifier fire alarm and evacuation systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105143922944,"sku":"AA-100","price":1636.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/shopping_91_55572a44-42c3-461f-9ed0-afd5c3173b73.webp?v=1785541221"},{"product_id":"ncm-f-notifier-fiber-optic-network-control-module-for-onyx-series-fire-alarm-systems","title":"NCM-F | Notifier Fiber-Optic Network Control Module for ONYX Series Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier NCM-F Network Control Module provides fiber-optic network communication for ONYX Series Fire Alarm Control Panels and annunciators. It enables high-speed, noise-immune data transfer across the NOTI•FIRE•NET™ network, ensuring reliable system integration and remote communication between multiple nodes.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 509.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eNCM-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eFiber-Optic Network Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eNFS-640, NFS-3030, NFS2-3030, NCA, NCA-2, ONYX Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eNOTI•FIRE•NET™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 39.2px;\"\u003e\u003cstrong\u003eCommunication Medium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 39.2px;\"\u003eFiber-Optic (Multimode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 39.2px;\"\u003e\u003cstrong\u003eSupported Fiber Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 39.2px;\"\u003e62.5\/125 µm or 50\/125 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eFiber Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eST® Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003e312.5 Kbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eOperation Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eNFPA Style 4 (Class B) or Style 7 (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003e820 nm (compatible with standard 850 nm fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 39.2px;\"\u003e\u003cstrong\u003eMaximum Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 39.2px;\"\u003e8 dB (62.5\/125 µm) or 4.2 dB (50\/125 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eOptical Isolation to Prevent Ground Loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eNode Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eTwo Ports (TX\/RX) for Fiber Interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eEnables Software and Database Upload\/Download\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 39.2px;\"\u003e\u003cstrong\u003eCompatible Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 39.2px;\"\u003eMIB-F, MIB-WF, NAM-232F, NCS-F, RPT-F, RPT-WF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eCHS-4L, CHS-M2, CHS-M3, or CHS-4N Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eUL Listed and NFPA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003eNetwork Communication for Fire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.0758%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7911%; height: 19.6px;\"\u003e0.2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eNCM-F\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe NCM-F is a multimode fiber-optic network control module developed by Notifier for use in ONYX Series fire alarm control systems. It allows high-speed, bidirectional data communication between control panels, repeaters, and annunciators over the NOTI•FIRE•NET™ network. Each NCM-F module supports two fiber ports (Transmit and Receive) that can interconnect nodes in either Class A or Class B network configurations. Designed for immunity to electrical interference and equipped with optical isolation, the module ensures secure data transfer and eliminates potential ground loops. Supporting standard 62.5\/125 µm or 50\/125 µm fiber with ST® connectors, the NCM-F provides flexible installation options and reliable integration for distributed fire alarm networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiber-Optic Data Communication: Provides high-speed data transfer across NOTI•FIRE•NET™ using multimode fiber cable.\u003c\/li\u003e\n\u003cli\u003eNoise Immunity and Isolation: Optical isolation protects against electrical noise and eliminates ground loop issues.\u003c\/li\u003e\n\u003cli\u003eDual Network Ports: Includes TX and RX ports for easy connection between nodes and repeaters in large network systems.\u003c\/li\u003e\n\u003cli\u003eFlexible Network Configuration: Supports NFPA Style 4 (Class B) and Style 7 (Class A) topologies.\u003c\/li\u003e\n\u003cli\u003eWide Fiber Compatibility: Operates with both 62.5\/125 µm and 50\/125 µm multimode fiber types using ST® connectors.\u003c\/li\u003e\n\u003cli\u003eHigh Transmission Reliability: Regenerates data at each node for consistent signal integrity throughout the network.\u003c\/li\u003e\n\u003cli\u003eSoftware Connectivity: Enables database upload\/download and programming via NOTI•FIRE•NET™.\u003c\/li\u003e\n\u003cli\u003eModular Installation Options: Fits CHS-4L, CHS-M2, CHS-M3, and CHS-4N chassis for integration into control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NCM-F delivers the reliability and precision required for secure, high-performance communication between ONYX Series fire alarm systems over fiber-optic networks.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105144185088,"sku":"NCM-F","price":1446.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/26_04_2024_18_45_36_NCM_F_Honeywell.jpg?v=1785541228"},{"product_id":"amg-1-notifier-audio-message-generator-for-am2020-and-afp1010-fire-alarm-systems","title":"AMG-1 | Notifier Audio Message Generator for AM2020 and AFP1010 Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier AMG-1 Audio Message Generator produces pre-recorded or user-defined voice messages and tones for emergency communication systems. Designed for use with Notifier AM2020 and AFP1010 fire alarm panels, it delivers low-level audio output to connected amplifiers for distribution across speaker zones.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 372.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eAMG-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eAudio Message Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eMessage and Tone Generation for Voice Evacuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eLow-Level Audio Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 39.2px;\"\u003e\u003cstrong\u003eCompatible Amplifiers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 39.2px;\"\u003eAA-30, AA-30E, AA-100, AA-100E, AA-120, AA-120E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eNotifier AM2020, AFP1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eMessage Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eMicrophone Recording or External Audio Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eAudio Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eStandard Low-Level Connector (Cassette or Line-In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eDrives Up to 50 Amplifiers per Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eContinuous or Triggered Message Playback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eRack or Panel Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eUL Listed Voice Communication Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eEmergency Voice Evacuation and Notification Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003eStandard Module Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3689%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.498%; height: 19.6px;\"\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eAMG-1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe AMG-1 Audio Message Generator from Notifier is a versatile tone and voice message unit designed to work with AM2020 and AFP1010 fire alarm control systems. It allows operators to store and broadcast emergency announcements, evacuation tones, or alert messages throughout a facility. The device can record messages directly through an onboard microphone or accept external input from a standard cassette or line-level source. Its low-level audio output feeds into Notifier amplifiers such as the AA-30 or AA-100 series, which then distribute the signal to speaker zones. The AMG-1’s design supports up to 50 amplifiers per channel, making it suitable for large-scale installations requiring clear and synchronized audio communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProgrammable Audio Output: Generates custom messages or standard alert tones for system annunciation.\u003c\/li\u003e\n\u003cli\u003eDual Recording Options: Allows recording through the built-in microphone or from an external audio source.\u003c\/li\u003e\n\u003cli\u003eWide Amplifier Compatibility: Interfaces with multiple Notifier audio amplifiers, including AA-30, AA-100, and AA-120 models.\u003c\/li\u003e\n\u003cli\u003eHigh Channel Capacity: Drives up to 50 amplifiers per channel for extensive coverage across speaker zones.\u003c\/li\u003e\n\u003cli\u003eIntegration Ready: Designed for seamless operation with Notifier AM2020 and AFP1010 fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eReliable Communication: Ensures consistent tone and message transmission for emergency voice systems.\u003c\/li\u003e\n\u003cli\u003eEasy Maintenance: Modular construction simplifies installation, service, and configuration.\u003c\/li\u003e\n\u003cli\u003eUL Certified Safety: Approved for use in life-safety and voice evacuation applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AMG-1 delivers the reliability and precision required for clear, customizable voice and tone communication in Notifier fire alarm and evacuation systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105144217856,"sku":"AMG-1","price":7497.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/AMG-1-1.jpg?v=1785541229"},{"product_id":"acm-8r-notifier-eight-relay-annunciator-control-module-for-fire-alarm-systems","title":"ACM-8R | Notifier Eight-Relay Annunciator Control Module for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier ACM-8R Annunciator Relay Control Module is an interface board that provides eight programmable relay outputs for use with compatible Notifier fire alarm control panels. Each relay can be individually configured to activate in response to system events such as alarms, troubles, or supervisory signals.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eACM-8R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eAnnunciator Relay Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003e8 individually programmable Form-C relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eRelay Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003e2 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eANN-BUS \/ EIA-485 (panel-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eFully supervised communication and power lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eRelay activation and communication status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003e24 mA (standby), 150 mA (maximum active)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eAnnunciator enclosure or remote cabinet mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003ePCB with protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003eApprox. 5.25\" H × 4.25\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.3567%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.424%;\"\u003e0.6 lb (0.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About ACM-8R\u003c\/h4\u003e\n\u003cp\u003eThe ACM-8R is part of Notifier’s annunciator module family, designed to expand the output and control capabilities of compatible fire alarm panels. This relay control module provides eight Form-C relays, each with independently programmable operation, allowing integration with auxiliary devices like door holders, HVAC shutdown relays, and local indicators. The ACM-8R communicates with the main control panel through the ANN-BUS or EIA-485 interface, ensuring supervised and secure communication. Compact and easily mountable, the module is suitable for installation within annunciator enclosures or remote control cabinets. The ACM-8R’s durable design and flexibility make it ideal for complex control logic and custom automation within fire protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEight Programmable Relays: Provides eight Form-C relays for system control and signal output.\u003c\/li\u003e\n\u003cli\u003eFlexible Activation Logic: Each relay can be programmed for alarm, trouble, supervisory, or custom functions.\u003c\/li\u003e\n\u003cli\u003eSupervised Communication: Connects to control panels via the ANN-BUS or EIA-485 interface.\u003c\/li\u003e\n\u003cli\u003eHigh Current Rating: Each relay supports up to 2 amps at 30 VDC or 0.5 amps at 30 VAC (resistive).\u003c\/li\u003e\n\u003cli\u003eLED Status Indicators: Displays communication and activity status for each relay channel.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits easily into standard annunciator enclosures or control panel cabinets.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Certified: Meets all relevant standards for control and annunciation modules.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed for use with select Notifier intelligent control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ACM-8R delivers the reliability and precision required for output control and automation in intelligent fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105149853952,"sku":"ACM-8R","price":865.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ACM-8R.jpg?v=1785541353"},{"product_id":"fci-chg-120-notifier-battery-charging-system-for-25-120-ah-standby-batteries","title":"FCI-CHG-120 | Notifier Battery Charging System for 25–120 A\/H Standby Batteries","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier FCI-CHG-120 Battery Charging System is a high-capacity, regulated charger designed to maintain and recharge standby batteries used in fire alarm and life-safety control systems. It supports battery capacities from 25 to 120 amp-hours and provides automatic float charging at 27.6 VDC for optimal battery maintenance.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eFCI-CHG-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eBattery Charging System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003ePrimary Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003e115 VAC, 60 Hz, 2 A \/ 230 VAC, 50 Hz, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eOutput Voltage (Float Charge)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003e27.6 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eMaximum Charging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003e4.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eRelay Output (TB3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eForm-C, 5 A @ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eFuse Ratings (F1-F3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003e15 A each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eBattery Capacity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003e25 A\/H to 120 A\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eCharging Time (25 A\/H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eApprox. 9 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eCharging Time (55 A\/H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eApprox. 20 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eCharging Time (120 A\/H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eApprox. 38 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eNumber of Batteries Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eTwo 24 VDC batteries (in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eMonitors line, battery, and charging status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eWall or cabinet mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eUL Listed; NFPA 72 power supply compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003eApprox. 13\" H × 11\" W × 4\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2262%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5545%;\"\u003e12.5 lb (5.67 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FCI-CHG-120\u003c\/h4\u003e\n\u003cp\u003eThe FCI-CHG-120 is a Notifier battery charging system engineered for use with fire alarm control panels and emergency power applications. It accepts primary input power at either 115 VAC, 60 Hz or 230 VAC, 50 Hz and delivers up to 4.5 amps of regulated charging current. This unit maintains two connected batteries in a fully charged, ready state while monitoring line and charging conditions. Equipped with Form-C relay contacts for status signaling and internal protection fuses, the FCI-CHG-120 provides safe, reliable charging performance in accordance with UL and NFPA power supply standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual AC Input Support: Operates on 115 VAC, 60 Hz or 230 VAC, 50 Hz input power.\u003c\/li\u003e\n\u003cli\u003eHigh Charging Capacity: Provides up to 4.5 amps of regulated charging current.\u003c\/li\u003e\n\u003cli\u003eWide Battery Range: Supports sealed lead-acid batteries from 25 A\/H to 120 A\/H capacity.\u003c\/li\u003e\n\u003cli\u003eAutomatic Float Charging: Maintains battery voltage at 27.6 VDC for extended battery life.\u003c\/li\u003e\n\u003cli\u003eRelay Output Monitoring: Includes Form-C relay rated at 5 A @ 30 VDC for status indication.\u003c\/li\u003e\n\u003cli\u003eFuse Protection: Three 15 A fuses safeguard against overload and fault conditions.\u003c\/li\u003e\n\u003cli\u003eEfficient Charging Cycle: Recharges fully discharged batteries in 9 to 38 hours depending on capacity.\u003c\/li\u003e\n\u003cli\u003eNotifier System Compatibility: Designed for use with Notifier fire alarm and auxiliary power systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FCI-CHG-120 delivers the reliability and precision required for maintaining standby power readiness in critical fire alarm and life-safety systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105151721728,"sku":"FCI-CHG-120","price":1468.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_4751c05a-a1f8-4b74-ae28-7bc1239fc7f4.webp?v=1785541393"},{"product_id":"nfn-gw-pc-hnmf-notifier-high-speed-nfn-gateway-pc-card-for-multi-mode-fiber-communication","title":"NFN-GW-PC-HNMF | Notifier High-Speed NFN Gateway PC Card for Multi-Mode Fiber Communication","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier NFN-GW-PC-HNMF High-Speed NFN Gateway PC Card is a network interface module designed to enable multi-mode fiber-optic connectivity for Notifier fire alarm networks. It facilitates high-speed communication between networked control panels, annunciators, and monitoring systems.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eNFN-GW-PC-HNMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eNetwork Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eHigh-speed NFN gateway card for multi-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eMulti-mode optical fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eNFN network communication via fiber link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eNotifier NFN-GW-PC chassis and ONYX Series panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eHigh-speed data transfer (NFN protocol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eSupplied by NFN-GW-PC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eFiber-optic connectors (multi-mode compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eIsolation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eOptical isolation for EMI\/RFI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003ePlug-in module for NFN-GW-PC enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eFiberglass PCB with optical connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eTypical Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eUp to 1.2 miles (2 km) using standard multi-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003eLED status indicators for link and activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6704%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.1103%;\"\u003e0.6 lb (0.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About NFN-GW-PC-HNMF\u003c\/h4\u003e\n\u003cp\u003eThe NFN-GW-PC-HNMF is a multi-mode fiber gateway card developed by Notifier for use within NFN (Notifier Fire Network) systems. Installed in an NFN-GW-PC chassis, it provides fiber-optic network communication between multiple fire alarm control panels, supporting high bandwidth and long-distance connectivity. The module enhances system integrity and signal speed, allowing critical alarm and supervisory data to transmit quickly and securely. Its multi-mode fiber configuration is ideal for medium-range installations where low latency and electrical isolation are required, such as campuses, large facilities, and industrial complexes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Speed Network Interface: Provides fast and reliable communication between NFN fire alarm devices.\u003c\/li\u003e\n\u003cli\u003eMulti-Mode Fiber Support: Designed for multi-mode fiber-optic cabling to reduce interference and maintain signal quality.\u003c\/li\u003e\n\u003cli\u003eNotifier NFN Compatibility: Works with Notifier ONYX Series panels and NFN-GW gateways.\u003c\/li\u003e\n\u003cli\u003eSecure Communication: Ensures data integrity with optical isolation and supervised connectivity.\u003c\/li\u003e\n\u003cli\u003eExtended Distance Capability: Supports medium-range fiber links across large facilities or multi-building sites.\u003c\/li\u003e\n\u003cli\u003eModular Design: Plugs into NFN-GW-PC chassis for streamlined installation and maintenance.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets all fire network communication requirements for life-safety systems.\u003c\/li\u003e\n\u003cli\u003eDisaster-Resilient Design: Immune to EMI\/RFI interference due to fiber-based transmission.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NFN-GW-PC-HNMF delivers the reliability and precision required for high-speed fiber-optic communication in advanced Notifier networked fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105151820032,"sku":"NFN-GW-PC-HNMF","price":8634.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/nfn-gw-pc-hnmf-489087.jpg?v=1785541397"},{"product_id":"fco-951-bp-notifier-advanced-multi-criteria-sensor-with-photoelectric-thermal-and-co-detection","title":"FCO-951-BP | Notifier Advanced Multi-Criteria Sensor with Photoelectric, Thermal, and CO Detection","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier FCO-951-BP Advanced Multi-Criteria Sensor is an intelligent addressable detector that combines multiple sensing technologies to provide fast and accurate fire detection. It integrates photoelectric, carbon monoxide, and thermal sensors to differentiate between real fire events and non-threatening conditions.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eFCO-951-BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eMulti-Criteria Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003ePhotoelectric, thermal, and carbon monoxide sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eFlashScan® intelligent addressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003e15–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003e300 µA (average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003e6.5 mA (LED on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eCO Sensing Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eDetects CO levels per UL 2075 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003e32°F to 100°F (0°C to 38°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eUp to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eMounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eB210LP or equivalent plug-in base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eDual color (green for normal, red for alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eFlame-retardant plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003e2.1\" (5.3 cm) height × 6.1\" (15.5 cm) diameter (with base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.6512%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1296%;\"\u003e0.3 lb (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FCO-951-BP\u003c\/h4\u003e\n\u003cp\u003eThe FCO-951-BP is part of Notifier’s ONYX intelligent sensor line, engineered to enhance fire detection accuracy by using a multi-criteria approach. It continuously analyzes data from photoelectric, heat, and CO sensing elements through Notifier’s FlashScan® protocol, enabling early warning of both flaming and smoldering fires while minimizing false alarms. The detector communicates detailed status and environmental data to the fire alarm control panel for intelligent decision-making. With its low-profile design and plug-in base mounting, the FCO-951-BP offers ease of installation and superior detection performance across diverse applications such as commercial, healthcare, and industrial facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-Criteria Detection: Combines photoelectric, heat, and CO sensing for comprehensive fire detection.\u003c\/li\u003e\n\u003cli\u003eIntelligent Addressable Communication: Operates on Notifier’s FlashScan® protocol for rapid and reliable data exchange.\u003c\/li\u003e\n\u003cli\u003eAdvanced Algorithms: Distinguishes between true fire signatures and nuisance sources to reduce false alarms.\u003c\/li\u003e\n\u003cli\u003eIntegrated CO Detection: Provides life-safety monitoring for carbon monoxide levels in addition to fire detection.\u003c\/li\u003e\n\u003cli\u003eLow-Profile Design: Compact housing enhances appearance and simplifies ceiling installation.\u003c\/li\u003e\n\u003cli\u003ePlug-In Mounting Base: Allows easy installation, replacement, and maintenance without rewiring.\u003c\/li\u003e\n\u003cli\u003eVisual Indicators: Dual-color LED for power, alarm, and fault status indication.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Certified: Fully compliant with life-safety and fire protection standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FCO-951-BP delivers the reliability and precision required for intelligent, multi-criteria fire detection in advanced life-safety systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105151918336,"sku":"FCO-951-BP","price":2644.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FCO-951.jpg?v=1785541399"},{"product_id":"acm-16at-notifier-16-point-annunciator-control-module-for-fire-alarm-systems","title":"ACM-16AT | Notifier 16-Point Annunciator Control Module for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier ACM-16AT Annunciator Control Module is a 16-point alarm and trouble annunciator interface designed for use with compatible Notifier fire alarm control panels. It provides clear visual indication and control for up to sixteen system points, enhancing local monitoring and response capabilities.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eACM-16AT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eAnnunciator Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003e16-point alarm\/trouble annunciator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003e16 supervised inputs\/outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eHardwired connection to compatible Notifier panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eIndividual LEDs for alarm, trouble, and normal states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eAcknowledge, reset, and silence options (panel-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eFully supervised wiring and signal integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003ePanel, rack, or cabinet installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003ePCB with protective coating and labeled terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eUL Listed; NFPA 72 compliant (legacy systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003eApprox. 8.5\" L × 5.5\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.9218%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.859%;\"\u003e0.9 lb (0.41 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About ACM-16AT\u003c\/h4\u003e\n\u003cp\u003eThe ACM-16AT is a modular annunciator control board developed by Notifier to display alarm, trouble, and supervisory status for up to sixteen zones or devices. Each point is equipped with dedicated LED indicators and control switches for acknowledgment, silence, or reset functions, depending on configuration. The module communicates directly with the control panel through supervised connections, ensuring accurate status reporting and operator interaction. Though discontinued by the manufacturer, the ACM-16AT remains a valuable component for maintaining and servicing existing Notifier annunciator installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16-Point Annunciation: Monitors up to sixteen alarm or trouble zones simultaneously.\u003c\/li\u003e\n\u003cli\u003eLED Status Indicators: Provides dedicated LEDs for each point to display alarm, trouble, or normal conditions.\u003c\/li\u003e\n\u003cli\u003eNotifier System Integration: Designed for use with compatible legacy Notifier fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003e24 VDC Operation: Low-voltage power ensures efficient and stable performance.\u003c\/li\u003e\n\u003cli\u003eModular Design: Can be mounted within an annunciator enclosure or rack assembly.\u003c\/li\u003e\n\u003cli\u003eOperator Controls: Supports acknowledgment and reset functions for enhanced user interaction.\u003c\/li\u003e\n\u003cli\u003eSupervised Communication: Detects wiring faults to maintain system reliability.\u003c\/li\u003e\n\u003cli\u003eLegacy Support: Ideal for upgrading or replacing annunciator modules in existing systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ACM-16AT delivers the reliability and precision required for annunciation and zone status indication in legacy fire alarm control systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105151951104,"sku":"ACM-16AT","price":4401.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ACM-16AT.jpg?v=1785541399"},{"product_id":"xp10-ma-notifier-ten-input-intelligent-monitor-module-for-fire-alarm-control-systems","title":"XP10-MA | Notifier Ten Input Intelligent Monitor Module for Fire Alarm Control Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier XP10-MA Ten Input Monitor Module is an intelligent interface device that enables connection of multiple initiating circuits to a Notifier intelligent fire alarm control panel. It provides ten supervised input channels for monitoring contact devices such as pull stations, waterflow switches, and conventional detectors.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eXP10-MA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eInput Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e10 supervised initiating device circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e15–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e3.8 mA (average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e68 mA (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eClass A (Style D) or Class B (Style B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eSLC loop – Notifier intelligent protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eLED status for communication, alarm, and trouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eUp to 93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eCabinet or chassis mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003ePlastic enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e6.8” H × 5.8” W × 1.0” D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e0.6 lb (0.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About XP10-MA\u003c\/h4\u003e\n\u003cp\u003eThe XP10-MA is part of Notifier’s intelligent module line, designed to expand the input capacity of ONYX Series and other compatible fire alarm control panels. It monitors up to ten independent initiating device circuits, each individually addressable through the system’s SLC (Signaling Line Circuit). Supporting both Class A (Style D) and Class B (Style B) wiring, the XP10-MA ensures flexible installation in a variety of system layouts. Compact and easily mountable, this module maintains consistent communication with the panel for real-time status updates, enhancing system reliability and fault tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTen Supervised Inputs: Monitors up to ten independent initiating device circuits.\u003c\/li\u003e\n\u003cli\u003eIntelligent Addressing: Each input is individually addressable for precise zone identification.\u003c\/li\u003e\n\u003cli\u003eClass A\/B Wiring Support: Compatible with both Style D and Style B circuits.\u003c\/li\u003e\n\u003cli\u003eNotifier System Integration: Works seamlessly with ONYX Series intelligent control panels.\u003c\/li\u003e\n\u003cli\u003eLED Indicators: Provides visible feedback for communication, alarm, and fault conditions.\u003c\/li\u003e\n\u003cli\u003eLow Power Consumption: Operates efficiently with 3.8 mA standby and 68 mA alarm current.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits neatly within standard electrical enclosures for easy installation.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets recognized standards for intelligent fire detection systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XP10-MA delivers the reliability and precision required for advanced input monitoring in addressable fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152049408,"sku":"XP10-MA","price":1971.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/NewProject_c985c53a-91ef-405a-bfec-b511d276c6d7.jpg?v=1785541403"},{"product_id":"ds-bda-notifier-125w-backup-audio-amplifier-for-ds-amp-systems-convertible-to-70v-100w","title":"DS-BDA | Notifier 125W Backup Audio Amplifier for DS-AMP Systems (Convertible to 70V 100W)","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier DS-BDA Backup Amplifier is a high-performance 125-watt, 25-volt audio amplifier designed as a redundant backup unit for the DS-AMP main amplifier. It ensures uninterrupted audio output during voice evacuation and paging operations in fire alarm and emergency communication systems.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eDS-BDA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eBackup Audio Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003e125W at 25V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eOptional Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003e70V, 100W (with DS-XF70V module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eAmplifier Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eBackup \/ redundant audio amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eBalanced audio input from DS-AMP system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eSupervised speaker circuit output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eNotifier DS-AMP and DVC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003e400 Hz – 4 kHz (voice band optimized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eAutomatic Switching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eEngages upon primary amplifier fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eSupplied from DS-AMP system power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eRack-mount or cabinet-mount configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003eApprox. 3.5\" H × 17\" W × 13\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7365%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.0442%;\"\u003e16.5 lb (7.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About DS-BDA\u003c\/h4\u003e\n\u003cp\u003eThe DS-BDA is a dedicated backup amplifier designed to work in conjunction with Notifier’s DS-AMP primary audio amplifiers within fire alarm and emergency voice evacuation systems. This amplifier automatically activates when the main amplifier fails or requires redundancy support, maintaining full system functionality and intelligible voice communication. Factory-rated at 125W at 25V, the DS-BDA can be field-converted to a 70V, 100W output when paired with the DS-XF70V conversion module. Its design meets UL requirements for emergency communication systems and is compatible with Notifier’s Digital Voice Command (DVC) and related distributed audio platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e125W Output Power: Provides 125 watts at 25V RMS for powerful and clear audio output.\u003c\/li\u003e\n\u003cli\u003eOptional 70V Conversion: Can be converted to 70V, 100W operation using the DS-XF70V module.\u003c\/li\u003e\n\u003cli\u003eAutomatic Backup Operation: Activates seamlessly when the main DS-AMP amplifier fails.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed for DS-AMP and DVC audio systems in fire alarm networks.\u003c\/li\u003e\n\u003cli\u003eHigh Audio Fidelity: Maintains clear, distortion-free emergency and paging communication.\u003c\/li\u003e\n\u003cli\u003eRugged Design: Built for reliable, continuous-duty operation in critical life-safety applications.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Certified for use in emergency voice\/alarm communication systems.\u003c\/li\u003e\n\u003cli\u003eRack Mountable: Compact form factor allows easy installation in standard equipment racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DS-BDA delivers the reliability and precision required for redundant audio amplification in emergency voice communication and fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152114944,"sku":"DS-BDA","price":1212.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ds-bda-592923.jpg?v=1785541404"},{"product_id":"4xarb-1-notifier-system-control-unit-motherboard-for-rp-1001-fire-alarm-panels","title":"4XARB-1 | Notifier System Control Unit Motherboard for RP-1001 Fire Alarm Panels","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier 4XARB-1 System Control Unit is a motherboard assembly designed for use with Notifier RP-1001 and related fire alarm control panels. It functions as the central signaling and processing board, managing system inputs, outputs, and alarm communications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003e4XARB-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eSystem Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eMain control motherboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eNotifier RP-1001 fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eSystem signaling, power distribution, and supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eInput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eMultiple supervised initiating zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eOutput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eNotification appliance and relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eInternal control bus and field wiring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eLED status for power, alarm, and fault conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eInternal control cabinet mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eMulti-layer fiberglass PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eUL Listed; NFPA 72 (legacy compliance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003eApprox. 11\" L × 8\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.0117%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.769%;\"\u003e1.1 lb (0.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 4XARB-1\u003c\/h4\u003e\n\u003cp\u003eThe 4XARB-1 is a system control motherboard developed by Notifier to serve as the core logic and communication interface within the RP-1001 fire alarm control panel series. It manages alarm detection circuits, notification appliance outputs, and system supervision, ensuring coordinated response to fire and fault conditions. This board provides the essential interconnections for power distribution, signal routing, and system control functions. Although discontinued by the manufacturer, the 4XARB-1 remains a key replacement component for maintaining and servicing existing Notifier legacy systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCentral Control Board: Serves as the main processing and signaling motherboard for RP-1001 systems.\u003c\/li\u003e\n\u003cli\u003eMulti-Zone Management: Handles multiple initiating and notification circuits for system coordination.\u003c\/li\u003e\n\u003cli\u003ePower Distribution Interface: Manages regulated DC power routing across connected modules.\u003c\/li\u003e\n\u003cli\u003eSystem Supervision: Monitors for open, short, and ground fault conditions on connected circuits.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed specifically for RP-1001 fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eLegacy Support: Essential for repairing or maintaining discontinued Notifier system configurations.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Indicators: Includes LED status lights for power, alarm, and trouble conditions.\u003c\/li\u003e\n\u003cli\u003eDurable PCB Construction: Built for long-term reliability in professional fire alarm systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4XARB-1 delivers the reliability and precision required for control and supervision in legacy Notifier signaling systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152475392,"sku":"4XARB-1","price":1065.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/c0e4c0f401354756aac3ef6b41c4bbcc.jpg?v=1785541407"},{"product_id":"izm-8-notifier-eight-zone-initiating-expander-module-for-fire-alarm-systems","title":"IZM-8 | Notifier Eight-Zone Initiating Expander Module for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier IZM-8 Initiating Zone Expander Module is an eight-zone expansion board designed to increase the detection capacity of compatible Notifier fire alarm control panels. It provides eight supervised initiating device circuits for connection to smoke detectors, heat sensors, and manual pull stations.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eIZM-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eInitiating Zone Expander Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eZone expansion interface board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eNumber of Zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003e8 supervised initiating device circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eDevice Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eTwo- and four-wire detectors, heat sensors, pull stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eCircuit Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eEnd-of-line resistor supervision for open\/short fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eCompatible with select Notifier legacy control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eLED status indication for each zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003ePanel-mounted or internal cabinet installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eFiberglass PCB with protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eUL Listed; NFPA 72 compliant (legacy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003eApprox. 8\" L × 5\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.4532%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.3275%;\"\u003e0.9 lb (0.41 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About IZM-8\u003c\/h4\u003e\n\u003cp\u003eThe IZM-8 is an expansion module developed by Notifier to add additional initiating zones to select conventional and addressable fire alarm control panels. Each of its eight supervised zones supports two-wire or four-wire devices and includes end-of-line supervision for fault detection. This module enables system designers to expand detection coverage in large or multi-area facilities without replacing the main control unit. Though discontinued by the manufacturer, the IZM-8 remains a trusted and essential component for maintaining and servicing existing Notifier fire alarm systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEight Initiating Circuits: Expands compatible panels with eight additional supervised input zones.\u003c\/li\u003e\n\u003cli\u003eSupervised Zones: Detects open, short, and ground fault conditions for each circuit.\u003c\/li\u003e\n\u003cli\u003eFlexible Compatibility: Works with a range of legacy Notifier fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eTwo- or Four-Wire Device Support: Accepts standard smoke detectors, heat sensors, and manual pull stations.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits within control panel enclosures or expansion bays for efficient use of space.\u003c\/li\u003e\n\u003cli\u003eReliable Operation: Provides consistent signal integrity and fault isolation per zone.\u003c\/li\u003e\n\u003cli\u003eDurable PCB Construction: Engineered for long-term service in demanding environments.\u003c\/li\u003e\n\u003cli\u003eLegacy Support: Ideal for maintaining discontinued or upgraded Notifier system installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe IZM-8 delivers the reliability and precision required for supervised zone expansion in fire alarm detection systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152540928,"sku":"IZM-8","price":992.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/eca5c6954f3546d080458a1b4d375c37.jpg?v=1785541410"},{"product_id":"afaws-telc-notifier-telephone-chassis-with-coil-cord-for-firefighter-communication-systems","title":"AFAWS-TELC | Notifier Telephone Chassis with Coil Cord for Firefighter Communication Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier AFAWS-TELC Telephone Chassis with Coil Cord is a dedicated communication interface designed for use in firefighter telephone and emergency communication systems. This chassis provides a secure mounting platform and integrated coiled handset cord for dependable voice communication during fire and emergency operations.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eAFAWS-TELC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 10px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 10px;\"\u003eTelephone Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eFirefighter\/emergency telephone interface chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eNotifier AFAWS firefighter telephone systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eChassis with attached coiled handset cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003ePanel or enclosure mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eCord Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eHeavy-duty, retractable coil cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eMetal housing with reinforced connection hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eAudio Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eLow-distortion voice transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eIndoor, dry location use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eColor\/Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eRed or gray (depending on system configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003eApprox. 5\" H × 4\" W × 2.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.5599%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.2208%; height: 19.5938px;\"\u003e1.2 lb (0.54 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About AFAWS-TELC\u003c\/h4\u003e\n\u003cp\u003eThe AFAWS-TELC is a telephone chassis assembly developed by Notifier for use with firefighter emergency communication systems and command stations. It serves as a housing and connection interface for a firefighter handset, featuring a pre-attached coiled cord that allows flexible operation and convenient storage. Built from heavy-duty materials, the AFAWS-TELC is designed to mount within Notifier AFAWS panels or related control enclosures. Its construction supports reliable two-way voice communication between emergency responders and control operators, meeting NFPA and UL requirements for firefighter telephone installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Coil Cord: Provides extended reach and flexibility for handset operation.\u003c\/li\u003e\n\u003cli\u003eRugged Chassis Design: Heavy-duty construction ensures long-term reliability under frequent use.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed for use with AFAWS and related firefighter telephone systems.\u003c\/li\u003e\n\u003cli\u003eClear Communication: Supports direct, noise-free voice transmission during emergency operations.\u003c\/li\u003e\n\u003cli\u003ePanel Mounting: Fits securely within compatible Notifier control or command station panels.\u003c\/li\u003e\n\u003cli\u003eServiceable Assembly: Coil cord and handset connection are easily replaceable for maintenance.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets standards for firefighter telephone system components.\u003c\/li\u003e\n\u003cli\u003eCompact Configuration: Optimized design for efficient enclosure integration and space management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AFAWS-TELC delivers the reliability and precision required for firefighter communication and emergency response systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152606464,"sku":"AFAWS-TELC","price":610.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/AFAWS-TELC-1.jpg?v=1785541411"},{"product_id":"notifier-rp-2001e-six-zone-deluge-preaction-fire-alarm-control-panel-with-flps-7-power-supply","title":"Notifier RP-2001E Six-Zone Deluge-Preaction Fire Alarm Control Panel with FLPS-7 Power Supply","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier RP-2001E Deluge-Preaction Control Panel is a six-zone, microprocessor-based fire alarm control unit designed for single and dual-hazard water-based suppression systems. Equipped with an FLPS-7 power supply rated at 240 VAC, 50 Hz, 2.085 amps, this panel provides precise detection and control for deluge and preaction fire suppression applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eRP-2001E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eDeluge-Preaction Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSix-zone fire alarm and releasing control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eSupported Hazards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSingle or dual hazard (deluge\/preaction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eFLPS-7 integrated power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e240 VAC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e2.085 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eDetection Zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSix supervised zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eNotification Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eTwo supervised outputs (NACs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eProgrammable relays for alarm and trouble functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eNotifier-compatible modules and accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCircuit Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eOpen, short, and ground fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eUp to 93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCabinet Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eSteel enclosure, red powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eUL Listed; NFPA 72 and releasing service compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003eApprox. 26\" H × 18\" W × 5.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.9167%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.864%;\"\u003e29 lb (13.15 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About RP-2001E\u003c\/h4\u003e\n\u003cp\u003eThe RP-2001E is a Notifier six-zone control panel engineered to manage deluge and preaction sprinkler systems in industrial, commercial, and special hazard facilities. It supports both single and dual-hazard configurations, offering flexibility for complex fire protection layouts. The integrated FLPS-7 power supply provides stable 24 VDC system power and supervision for connected detection and release circuits. Designed for compatibility with Notifier detectors, modules, and notification appliances, the RP-2001E meets UL and NFPA requirements for releasing service and fire suppression control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix Detection Zones: Supports multiple supervised input circuits for system flexibility.\u003c\/li\u003e\n\u003cli\u003eDual-Hazard Capability: Configurable for single or dual-hazard deluge or preaction systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated Power Supply: Includes FLPS-7 module rated at 240 VAC, 50 Hz, 2.085 A.\u003c\/li\u003e\n\u003cli\u003eReleasing Service Approved: Designed and listed for use with deluge and preaction suppression applications.\u003c\/li\u003e\n\u003cli\u003eNotifier System Integration: Compatible with a wide range of Notifier detectors and notification devices.\u003c\/li\u003e\n\u003cli\u003eSupervised Circuits: Ensures fault detection for open, short, and ground conditions.\u003c\/li\u003e\n\u003cli\u003eUser-Friendly Interface: LED indicators and zone controls simplify monitoring and operation.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Compliant: Meets requirements for fire alarm and releasing service panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RP-2001E delivers the reliability and precision required for deluge and preaction fire suppression control in demanding industrial and commercial applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152803072,"sku":"RP-2001E","price":1634.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/RP-2001E.webp?v=1785541418"},{"product_id":"abs-4d-notifier-annunciator-surface-box-for-acs-and-scs-modules-black-finish","title":"ABS-4D | Notifier Annunciator Surface Box for ACS and SCS Modules (Black Finish)","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier ABS-4D Annunciator Surface Box is a durable enclosure designed to house Notifier ACS and SCS series annunciator modules. It provides a secure, professional mounting solution for surface or semi-flush installations. Finished in black, the ABS-4D ensures a clean, consistent appearance while protecting internal components in fire alarm system applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 417.082px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eABS-4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eAnnunciator Surface Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.8px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 34.8px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 34.8px;\"\u003eSurface or semi-flush wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eNotifier ACS and SCS annunciator modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eHeavy-duty steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eBlack powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eAccess Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eFront access for annunciator installation and service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003ePre-drilled mounting holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eIndoor use; dry environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 10px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 10px;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eUL Listed; NFPA 72 compatible construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003eApprox. 10.5\" H × 14.5\" W × 2.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.9708%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8099%; height: 19.5938px;\"\u003e4.2 lb (1.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About ABS-4D\u003c\/h4\u003e\n\u003cp\u003eThe ABS-4D is an annunciator surface box developed by Notifier to support ACS (Annunciator Control System) and SCS (Serial Control System) display modules. This enclosure can be installed either on the surface of a wall or recessed for a semi-flush finish, providing flexibility in new or retrofit fire alarm projects. Constructed from high-quality steel and finished in durable black powder coating, the ABS-4D ensures long-lasting protection for annunciator electronics. It is part of Notifier’s standard mounting hardware lineup and is designed to maintain a uniform appearance across multi-panel installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Mounting Options: Supports both surface and semi-flush wall installations.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed for ACS and SCS annunciator modules.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Heavy-duty steel housing provides protection and rigidity.\u003c\/li\u003e\n\u003cli\u003eProfessional Appearance: Black powder-coated finish ensures a clean, modern look.\u003c\/li\u003e\n\u003cli\u003eFlexible Installation: Suitable for new builds or retrofit fire alarm applications.\u003c\/li\u003e\n\u003cli\u003eSecure Mounting: Includes pre-drilled mounting points for stable installation.\u003c\/li\u003e\n\u003cli\u003eProtective Design: Shields annunciator components from dust and physical impact.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets enclosure requirements for fire alarm annunciation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ABS-4D delivers the reliability and precision required for professional annunciator installation in commercial fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152835840,"sku":"ABS-4D","price":1152.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ABS-4D.jpg?v=1785541418"},{"product_id":"dr-c4b-notifier-door-assembly-for-fire-alarm-control-panel-enclosures","title":"DR-C4B | Notifier Door Assembly for Fire Alarm Control Panel Enclosures","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier DR-C4B Door Assembly is a robust front access panel designed for use with Notifier fire alarm control cabinets. This door assembly provides a secure, professional-grade enclosure cover that protects internal components while allowing convenient access for service and maintenance.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eDR-C4B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eDoor Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eHeavy-gauge steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eRed powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 39.1875px;\"\u003e\u003cstrong\u003eCabinet Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 39.1875px;\"\u003eNotifier control panel enclosures (e.g., ONYX Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eIncluded (hinges, screws, and fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eAccess Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eHinged front access panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 39.1875px;\"\u003e\u003cstrong\u003eLocking Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 39.1875px;\"\u003eKeyed or latch option depending on model configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eVentilation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eSolid door (non-vented design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eSurface-mounted door for cabinet enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eIndoor, dry locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eUL and NFPA 72 compatible construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eFire alarm red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003eApprox. 20\" H × 16\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%; height: 19.5938px;\"\u003e8.6 lb (3.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About DR-C4B\u003c\/h4\u003e\n\u003cp\u003eThe DR-C4B is a door assembly developed by Notifier for use with compatible control panel enclosures in the ONYX Series and related fire alarm systems. Constructed from heavy-duty steel, it features a precision-fit design that ensures a secure seal and protection for internal electronic assemblies. The door includes pre-installed hinges and hardware, simplifying field installation or replacement in multi-module system configurations. With its durable finish and standardized dimensions, the DR-C4B provides reliable enclosure protection and a professional appearance for fire alarm installations in commercial and industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDurable Construction: Made from heavy-gauge steel for maximum rigidity and protection.\u003c\/li\u003e\n\u003cli\u003eSecure Fit: Designed specifically for compatible Notifier control cabinets for precise installation.\u003c\/li\u003e\n\u003cli\u003eEasy Access: Hinged design allows convenient service and inspection of system components.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Fits ONYX Series and other Notifier control panel enclosures.\u003c\/li\u003e\n\u003cli\u003eProfessional Finish: Powder-coated red surface maintains system uniformity and fire safety visibility.\u003c\/li\u003e\n\u003cli\u003eIncluded Hardware: Comes with pre-mounted hinges and required mounting hardware.\u003c\/li\u003e\n\u003cli\u003eReliable Protection: Shields system electronics from dust, impact, and accidental contact.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets safety standards for fire alarm cabinet assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DR-C4B delivers the reliability and precision required for secure and professional fire alarm system enclosure applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152770304,"sku":"DR-C4B","price":674.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/DR-C4B.jpg?v=1785541418"},{"product_id":"n-ann-rly-notifier-relay-module-for-ann-bus-fire-alarm-systems-with-programmable-outputs","title":"N-ANN-RLY | Notifier Relay Module for ANN-BUS Fire Alarm Systems with Programmable Outputs","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier N-ANN-RLY Relay Module is an addressable annunciator accessory designed to provide programmable relay outputs for Notifier fire alarm control panels. It allows activation of external devices such as fans, doors, or auxiliary signaling circuits in response to specific system conditions.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eN-ANN-RLY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eRelay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e24 VDC (ANN-BUS connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eRelay Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eThree Form-C relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eContact Rating (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e2 Amps @ 30 VDC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eContact Rating (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e0.5 Amps @ 30 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eANN-BUS (Notifier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003ePower-limited and supervised connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e93% ± 2% RH (non-condensing at 90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eSurface or enclosure mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eUsage Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eIndoor, dry environments only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eStatus LEDs for power and relay activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.4839%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.2968%;\"\u003e0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About N-ANN-RLY\u003c\/h4\u003e\n\u003cp\u003eThe N-ANN-RLY is a supervised relay module developed by Notifier for use with compatible fire alarm control panels that utilize the ANN-BUS communication interface. This module provides three programmable Form-C relays that can be configured for system status signals such as alarm, trouble, or supervisory events. The compact design allows mounting within or near the main fire alarm panel enclosure, simplifying installation and wiring. Operating at 24 VDC, the N-ANN-RLY ensures dependable control and monitoring in commercial, industrial, and institutional fire protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProgrammable Relays: Three Form-C relays configurable for alarm, trouble, or supervisory conditions.\u003c\/li\u003e\n\u003cli\u003eSupervised ANN-BUS Connection: Ensures reliable communication and fault detection with the control panel.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits within or near the main enclosure for flexible installation.\u003c\/li\u003e\n\u003cli\u003ePower-Limited Circuits: Meets safety standards for supervised fire alarm wiring.\u003c\/li\u003e\n\u003cli\u003eRobust Contact Ratings: Supports up to 2A @ 30VDC or 0.5A @ 30VAC resistive loads.\u003c\/li\u003e\n\u003cli\u003eLow Power Consumption: 15 mA standby and 75 mA in alarm for efficient operation.\u003c\/li\u003e\n\u003cli\u003eEnvironmental Resilience: Operates reliably in temperatures from 32°F to 120°F (0°C to 49°C).\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Integrates seamlessly with ONYX and other Notifier fire alarm systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe N-ANN-RLY delivers the reliability and precision required for auxiliary control and relay signaling in professional fire alarm installations.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105153130752,"sku":"N-ANN-RLY","price":524.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/n-ann-rly_edited_1.jpg?v=1785541421"},{"product_id":"eqdr-b4-notifier-two-tier-vented-door-assembly-for-onyx-series-fire-alarm-control-panels","title":"EQDR-B4 | Notifier Two-Tier Vented Door Assembly for Onyx Series Fire Alarm Control Panels","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier EQDR-B4 Two-Tier Vented Door Assembly is a precision-engineered enclosure component designed for Onyx Series fire alarm control panels. This door assembly provides a secure, ventilated front cover for two-tier cabinet configurations, ensuring optimal airflow and system protection.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eEQDR-B4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eDoor Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eTwo-tier vented door panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eNotifier Onyx Series control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eCabinet Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eEQ-series backboxes (e.g., EQB-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eHeavy-gauge steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eRed powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eVentilation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eIntegrated louvered vents for airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eAccess Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eKeyed lock mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eMounting Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eIncluded with assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eHinge Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003ePre-mounted steel hinges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eUL and NFPA 72 compatible construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eIndoor, dry location installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003eApprox. 28\" H × 24\" W × 2\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1944%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.5863%;\"\u003e14.8 lb (6.71 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About EQDR-B4\u003c\/h4\u003e\n\u003cp\u003eThe EQDR-B4 is a two-tier vented door assembly developed by Notifier for use with its Onyx Series fire alarm system enclosures. It is designed to fit compatible EQ-series backboxes, offering ventilation slots to maintain proper heat dissipation for internal modules and electronics. The door assembly includes mounting hardware, hinges, and a keyed lock mechanism for authorized access. Built from heavy-gauge steel and finished in Notifier’s standard red powder coating, the EQDR-B4 ensures both functionality and a consistent appearance in professional fire alarm control installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Tier Design: Provides full coverage for dual-level panel configurations in Onyx systems.\u003c\/li\u003e\n\u003cli\u003eVented Construction: Integrated ventilation slots support thermal management of control electronics.\u003c\/li\u003e\n\u003cli\u003eHeavy-Gauge Steel: Ensures long-term durability and structural rigidity.\u003c\/li\u003e\n\u003cli\u003eSecure Access: Equipped with a keyed lock mechanism for authorized entry only.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed specifically for EQ-series backboxes and Onyx control panels.\u003c\/li\u003e\n\u003cli\u003eProfessional Finish: Red powder-coated surface maintains consistent fire alarm system aesthetics.\u003c\/li\u003e\n\u003cli\u003eEasy Installation: Pre-aligned hinges and hardware simplify mounting and maintenance.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets industry standards for enclosure safety and reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EQDR-B4 delivers the reliability and precision required for protective and ventilated housing of Notifier Onyx Series control systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105153196288,"sku":"EQDR-B4","price":712.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/EQDR-B4.jpg?v=1785541422"},{"product_id":"fst-951-bp-notifier-intelligent-addressable-heat-detector-for-onyx-fire-alarm-systems","title":"FST-951-BP | Notifier Intelligent Addressable Heat Detector for ONYX Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier FST-951-BP Heat Detector is a high-sensitivity thermal detection device engineered for commercial and industrial fire alarm systems. This intelligent addressable detector monitors temperature changes to provide rapid response to fire conditions.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eFST-951-BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eHeat Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eIntelligent addressable heat detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eFixed temperature and rate-of-rise sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003e15–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003e300 µA (average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003e6.5 mA (LED on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eAlarm Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003e135°F (57°C) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eNotifier FlashScan® intelligent protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eMounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eB210LP or equivalent plug-in base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eDual color (green for normal, red for alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003e32°F to 100°F (0°C to 38°C); up to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003eFire-resistant plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003e2.1\" (5.3 cm) height × 6.1\" (15.5 cm) diameter (with base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4328%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.348%;\"\u003e0.3 lb (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FST-951-BP\u003c\/h4\u003e\n\u003cp\u003eThe FST-951-BP is an intelligent addressable heat detector from Notifier’s ONYX series, designed for use with compatible Notifier control panels. It employs advanced thermal sensing technology to detect fixed-temperature and rate-of-rise conditions, ensuring early fire detection in a wide range of environments. The detector communicates with the control panel via a digital protocol, providing accurate status feedback and diagnostic data. With a sleek low-profile housing and plug-in base design, the FST-951-BP simplifies installation and maintenance while maintaining compliance with UL and NFPA fire protection standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntelligent Addressable Design: Communicates directly with Notifier ONYX control panels for accurate system integration.\u003c\/li\u003e\n\u003cli\u003eFixed and Rate-of-Rise Detection: Monitors both sudden temperature increases and threshold exceedance for comprehensive coverage.\u003c\/li\u003e\n\u003cli\u003eAdvanced Thermal Sensor: Ensures fast, precise detection in high-risk fire environments.\u003c\/li\u003e\n\u003cli\u003eLow-Profile Housing: Compact design blends seamlessly into modern building aesthetics.\u003c\/li\u003e\n\u003cli\u003ePlug-In Mounting Base: Allows easy installation, replacement, and service without rewiring.\u003c\/li\u003e\n\u003cli\u003eEnvironmental Compensation: Maintains stability and accuracy across varying temperature ranges.\u003c\/li\u003e\n\u003cli\u003eLED Status Indicator: Provides visual confirmation of power, alarm, and fault conditions.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Certified: Fully compliant with recognized safety and fire protection standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FST-951-BP delivers the reliability and precision required for intelligent heat detection in commercial and industrial fire protection systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105153261824,"sku":"FST-951-BP","price":1262.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_73d9e5c7-6da5-4e09-b15d-01b00c91adf7.webp?v=1785541425"},{"product_id":"xpc-8-notifier-eight-circuit-supervised-control-module-for-fire-alarm-systems","title":"XPC-8 | Notifier Eight Circuit Supervised Control Module for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier XPC-8 Eight Circuit Supervised Control Module is a multi-zone control board designed for integration with Notifier fire alarm and voice evacuation systems. It provides eight independently supervised output circuits for control and monitoring of external devices.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eXPC-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eSupervised Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eEight-circuit supervised control board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e8 independently supervised outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eCircuit Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eOpen and short circuit fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eOutput Current (per circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e2.0 A maximum (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eNotifier system compatible (legacy control panels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003ePower and circuit status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003ePanel or enclosure mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eBoard Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eFiberglass PCB with protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eUL recognized; NFPA 72 compliant (legacy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eApprox. 10\" L × 6\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e1.4 lb (0.64 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About XPC-8\u003c\/h4\u003e\n\u003cp\u003eThe XPC-8 is an eight-circuit supervised control module developed by Notifier for use in complex fire alarm and notification systems. It functions as a control board to manage auxiliary outputs such as relays, strobes, door holders, or signaling devices, with supervision on each circuit for fault detection. Each of the eight channels operates independently, allowing customized zone control or grouped device operation. Though discontinued by the manufacturer, the XPC-8 remains a dependable solution for maintaining or upgrading legacy Notifier fire alarm installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEight Supervised Circuits: Provides control for up to eight individually supervised output channels.\u003c\/li\u003e\n\u003cli\u003eIndependent Operation: Each circuit can be configured for separate or grouped device control.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Designed for use with Notifier control and voice evacuation systems.\u003c\/li\u003e\n\u003cli\u003eFault Supervision: Monitors for open and short circuit conditions to ensure line integrity.\u003c\/li\u003e\n\u003cli\u003eCompact Control Board: Efficient design allows easy installation within control enclosures.\u003c\/li\u003e\n\u003cli\u003eStatus Indication: Includes diagnostic LEDs for channel and power status monitoring.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: High-quality PCB design for long-term reliability in fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eLegacy Support: Ideal for maintaining or replacing components in existing Notifier systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XPC-8 delivers the reliability and precision required for supervised circuit control in advanced fire alarm and notification applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105153327360,"sku":"XPC-8","price":1112.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_9d62fa5c-efdb-4f94-9444-b3414a3117bb.webp?v=1785541427"},{"product_id":"cmic-1-notifier-fire-alarm-chassis-with-integrated-paging-microphone-for-voice-evacuation-systems","title":"CMIC-1 | Notifier Fire Alarm Chassis with Integrated Paging Microphone for Voice Evacuation Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier CMIC-1 Fire Alarm System Chassis with Paging Microphone is a compact audio control and communication module designed for Notifier voice evacuation systems. It integrates a high-quality paging microphone with essential audio circuitry for live announcements and emergency communication.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eCMIC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eMicrophone Chassis Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eRack or cabinet mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eMicrophone Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003ePush-to-talk dynamic microphone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eSteel chassis with mounting hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eSupplied from Notifier control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eAudio Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eBalanced, preamplified signal to system input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eNotifier DVC and compatible voice evacuation systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eCommunication Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eLive voice paging and announcements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eControl Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eKeyed enable and status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003eApprox. 14\" W × 8\" H × 3\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.2807%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.5%;\"\u003e7.2 lb (3.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About CMIC-1\u003c\/h4\u003e\n\u003cp\u003eThe CMIC-1 is an integrated microphone chassis assembly used within Notifier’s fire alarm and emergency voice evacuation systems. It combines a paging microphone, preamplifier, and control interface within a single metal housing for efficient installation. Designed to operate as part of the Digital Voice Command (DVC) or equivalent Notifier audio systems, the CMIC-1 supports live voice paging and system-wide announcements. Its durable construction and standardized mounting make it suitable for installation in commercial, institutional, and industrial fire alarm systems where reliability and clarity are essential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Design: Combines microphone, amplifier, and control circuitry in a single chassis.\u003c\/li\u003e\n\u003cli\u003eHigh-Quality Paging: Provides clear, intelligible live voice paging across connected fire alarm zones.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Fully compatible with Notifier DVC and other voice evacuation components.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Steel chassis ensures long-term reliability in demanding environments.\u003c\/li\u003e\n\u003cli\u003eEasy Installation: Standard rack or cabinet mounting simplifies setup and maintenance.\u003c\/li\u003e\n\u003cli\u003eSecure Operation: Includes push-to-talk microphone with keyed activation for authorized use.\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Supports both local and system-wide paging capabilities.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Compliance: Meets regulatory standards for fire alarm and emergency communication systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CMIC-1 delivers the reliability and precision required for critical fire alarm voice paging and system communication.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105153392896,"sku":"CMIC-1","price":799.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/hbt-fire-cmic-1-cmic-1-fire-alarm-system-chassis-with-paging-microphone-primaryimage.jpg?v=1785541428"},{"product_id":"nfc-rm-notifier-first-command-remote-microphone-with-all-call-paging-and-secure-keypad-lock","title":"NFC-RM | Notifier First Command Remote Microphone with All-Call Paging and Secure Keypad Lock","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier NFC-RM First Command Remote Microphone is a standalone voice communication accessory designed for use with Notifier’s First Command emergency voice evacuation systems. This remote microphone unit enables live all-call paging across connected zones with a built-in push-to-talk microphone.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eNFC-RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eRemote Microphone Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eMicrophone Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eBuilt-in dynamic microphone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003e24 VDC non-resettable power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eApproximately 0.3 A (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eAudio Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eAll-call paging and live announcements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eControl Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003ePush-to-talk button with LED status indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eSecurity Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eKeypad lock and secure cabinet door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eNotifier First Command voice communication systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eSteel cabinet with powder-coated finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eCommunication Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eRemote operation up to 1,000 ft (dependent on system wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003eApprox. 14\" H × 12\" W × 3.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.057%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7237%;\"\u003e7.0 lb (3.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About NFC-RM\u003c\/h4\u003e\n\u003cp\u003eThe NFC-RM is a remote microphone panel designed specifically for use with the Notifier First Command (FCPS and FC-2000) series systems. It allows authorized personnel to broadcast live voice messages to all paging zones during fire, emergency, or evacuation conditions. The unit includes a built-in microphone, illuminated push-to-talk control, and a lockable cabinet with keypad access for security. Operating on 24 VDC non-resettable power, the NFC-RM provides dependable system extension capability for remote or centralized paging locations in commercial and institutional buildings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll-Call Paging: Enables live voice announcements to all system zones simultaneously.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Microphone: Integrated high-quality microphone for clear voice communication.\u003c\/li\u003e\n\u003cli\u003ePush-to-Talk Control: Simple and intuitive activation ensures quick emergency paging.\u003c\/li\u003e\n\u003cli\u003eSecure Access Design: Keypad lock prevents unauthorized operation or tampering.\u003c\/li\u003e\n\u003cli\u003e24 VDC Operation: Uses non-resettable power input for continuous readiness.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed for seamless integration with Notifier First Command systems.\u003c\/li\u003e\n\u003cli\u003eCabinet Construction: Durable metal enclosure for wall-mount installation and protection.\u003c\/li\u003e\n\u003cli\u003eEmergency Use Ready: Compliant with UL and NFPA standards for life safety systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NFC-RM delivers the reliability and precision required for emergency paging and evacuation voice communication applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105153491200,"sku":"NFC-RM","price":1421.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/NFC-RM.png?v=1785541430"},{"product_id":"rm-1sa-notifier-remote-microphone-assembly-for-fire-alarm-voice-paging-systems","title":"RM-1SA | Notifier Remote Microphone Assembly for Fire Alarm Voice Paging Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier RM-1SA Microphone Assembly is a high-performance remote microphone designed for use with fire alarm and emergency voice communication systems. This unit provides reliable live voice paging capability, ensuring clear audio transmission during critical situations.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eRM-1SA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eMicrophone Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eWall-mounted (surface or semi-flush)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eMicrophone Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eDynamic push-to-talk microphone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eLockable metal door with key access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eSupplied by connected control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eNotifier fire alarm voice evacuation systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eAudio Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eBalanced audio signal to system input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eColor\/Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eRed with white emergency labeling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eCommunication Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eManual voice paging and announcements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003eApprox. 14\" H × 12\" W × 3.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3703%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4104%;\"\u003e6.5 lb (2.95 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About RM-1SA\u003c\/h4\u003e\n\u003cp\u003eThe RM-1SA is a remote microphone assembly developed for use with Notifier voice evacuation and paging systems. It features a durable, wall-mounted design with a secure key-lock cover to prevent unauthorized use. This unit interfaces directly with compatible Notifier fire alarm control panels to enable manual voice paging in specific zones or throughout the system. Designed to meet fire code requirements, the RM-1SA ensures clear voice communication in emergency environments such as commercial, industrial, and institutional buildings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged Construction: Built with a protective locking enclosure for durability and security in high-traffic areas.\u003c\/li\u003e\n\u003cli\u003eClear Audio Transmission: High-quality microphone ensures intelligible live paging announcements during emergencies.\u003c\/li\u003e\n\u003cli\u003ePanel Integration: Fully compatible with Notifier fire alarm and voice evacuation systems for seamless communication.\u003c\/li\u003e\n\u003cli\u003eZone Paging Capability: Enables selective or all-call paging across multiple audio zones.\u003c\/li\u003e\n\u003cli\u003eEasy Operation: Simple interface with push-to-talk functionality for quick activation.\u003c\/li\u003e\n\u003cli\u003eSecure Access: Key-operated door prevents tampering and unauthorized paging use.\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting: Designed for surface or semi-flush wall mounting configurations.\u003c\/li\u003e\n\u003cli\u003eRegulatory Compliance: Meets applicable UL and NFPA standards for emergency communication equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RM-1SA delivers the reliability and precision required for critical fire alarm voice paging and emergency communication systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105153523968,"sku":"RM-1SA","price":911.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/not_rm-1sa.jpg?v=1785541430"},{"product_id":"jcpu2-640-notifier-central-processing-unit-for-nfs2-640-fire-alarm-system-120v-ac-5060hz","title":"JCPU2-640 | Notifier Central Processing Unit for NFS2-640 Fire Alarm System, 120V AC, 50\/60Hz","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier JCPU2-640 is a central processing unit (CPU) designed for use with the NFS2-640 intelligent fire alarm control panel. Operating on 120 VAC power at 50\/60 Hz, it provides control, monitoring, and communication functions for both stand-alone and networked fire alarm systems requiring a main display interface.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eNotifier (by Honeywell)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eJCPU2-640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eCentral Processing Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eNFS2-640 Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003e120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eOccupies three chassis positions in the main layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eDisplay Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eSupports JNCA-2 Primary Display (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003e640-character backlit LCD when paired with display unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eOne built-in Signaling Line Circuit (expandable to two)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eOperation Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eStand-alone or networked (with network control options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eProcessor Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eManages detection, control, and event logging for fire systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eNetworking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eSupports Notifier fire system network configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003ePrimary control and monitoring module for NFS2-640 systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eFactory-mounted on chassis; includes installation and programming manuals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003e8.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eJCPU2-640\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe JCPU2-640 is the primary control and processing component for the Notifier NFS2-640 intelligent fire alarm system. It integrates central logic processing, system communication, and loop control within a single chassis-mounted assembly. The unit includes one factory-installed Signaling Line Circuit (SLC) that can be expanded to two, supporting large-scale detection and monitoring networks. It manages system events, alarm processing, and supervision, ensuring fast and reliable fire detection performance. When used with the JNCA-2 display module, it provides a 640-character backlit interface for real-time system information. Designed for both standalone and networked configurations, the JCPU2-640 offers high performance and flexibility for advanced fire protection installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated CPU Assembly: Combines processing, loop control, and power supply in a single, factory-mounted chassis module.\u003c\/li\u003e\n\u003cli\u003eFlexible System Configuration: Supports both stand-alone and networked operation for scalable fire alarm installations.\u003c\/li\u003e\n\u003cli\u003eExpandable SLC Capability: Comes with one Signaling Line Circuit, expandable to two for extended device capacity.\u003c\/li\u003e\n\u003cli\u003eDisplay Compatibility: Interfaces with the JNCA-2 optional primary display providing a 640-character backlit LCD readout.\u003c\/li\u003e\n\u003cli\u003eReliable Power Architecture: Operates on 120 VAC input, with an integral power supply for consistent performance.\u003c\/li\u003e\n\u003cli\u003eCompact Mounting Design: Occupies three chassis positions in the first layer, optimizing panel space utilization.\u003c\/li\u003e\n\u003cli\u003eAdvanced System Control: Executes alarm logic, monitoring, and event management functions for full fire system supervision.\u003c\/li\u003e\n\u003cli\u003eNotifier Network Support: Integrates seamlessly into networked NFS2-640 systems, enabling multi-panel coordination and data sharing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe JCPU2-640 delivers the reliability and precision required for centralized control and monitoring in Notifier’s NFS2-640 intelligent fire detection systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105154441472,"sku":"JCPU2-640","price":8665.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/75f2add81d304e0d9b8b3ca0f5afe430.jpg?v=1785541459"},{"product_id":"pse-6e-notifier-6a-24v-remote-charger-power-supply-with-240vac-input","title":"PSE-6E | Notifier 6A 24V Remote Charger Power Supply with 240VAC Input","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier PSE-6E is a 6-amp, 24VDC remote charger power supply designed for use in fire alarm and life safety systems. Operating at 240 VAC and housed in a lockable metal enclosure, it provides regulated power output, battery charging, and supervision for auxiliary and notification circuits.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 578.22px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003ePower Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003ePSE-6E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eRemote Charger Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e24VDC regulated power supply and battery charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e240 VAC, 50\/60 Hz, 6.0A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eTotal Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e6.0A continuous (regulated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 39.1875px;\"\u003e\u003cstrong\u003eOutput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 39.1875px;\"\u003eTB8–TB9: 1A regulated\/3A special; TB10–TB12: 0.3A regulated\/3A special\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 10px;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 10px;\"\u003e24VDC filtered and regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eAuxiliary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e24VDC for notification and auxiliary devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrigger Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e9–32VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrigger Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e2.0mA (16–32VDC); 1.0mA (9–16VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrouble Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e4A @ 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 39.1875px;\"\u003e\u003cstrong\u003eBattery Charging Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 39.1875px;\"\u003e27.6VDC float\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Charge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e1.5A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 39.1875px;\"\u003e\u003cstrong\u003eInternal Battery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 39.1875px;\"\u003eUp to two 18AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 39.1875px;\"\u003e\u003cstrong\u003eExternal Battery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 39.1875px;\"\u003eUp to 33AH (using external cabinet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eLead-acid, sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCabinet Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eLockable metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e20.0\" H × 14.5\" W × 3.5\" D (50.8 × 36.83 × 8.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e24 lbs (with 7AH batteries), 39 lbs (with 18AH batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e32°F–120°F (0°C–49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003e10%–93% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eRemote power and battery charging for fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.2295%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.5512%; height: 19.5938px;\"\u003eUL listed (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About PSE-6E\u003c\/h4\u003e\n\u003cp\u003eThe PSE-6E is part of Notifier’s PSE Series of fire alarm power supplies, engineered to expand system power capacity or serve as a standalone regulated supply. It provides 6.0 amps of total output current across multiple filtered and regulated circuits, supporting both continuous and special-application loads. Equipped with a supervised charging circuit, it maintains lead-acid batteries up to 18 AH internally or up to 33 AH externally for extended standby capability. Designed for 240 VAC, 50\/60 Hz operation, the PSE-6E features built-in trouble relays, programmable trigger inputs, and secure cabinet mounting—making it ideal for commercial, institutional, and industrial fire protection applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Output Capacity: Provides 6.0A total regulated 24VDC output for fire alarm devices.\u003c\/li\u003e\n\u003cli\u003e240 VAC Input: Operates on 240 VAC, 50\/60 Hz for global installations.\u003c\/li\u003e\n\u003cli\u003eBattery Charging: Float-charges lead-acid batteries up to 18 AH internal or 33 AH external.\u003c\/li\u003e\n\u003cli\u003eRegulated Output Circuits: Includes multiple 24VDC filtered and special-application outputs.\u003c\/li\u003e\n\u003cli\u003eTrigger Inputs: Accepts 9–32VDC activation signals for supervised operation.\u003c\/li\u003e\n\u003cli\u003eTrouble Relay: Rated at 4A, 24VDC for reporting power or supervision faults.\u003c\/li\u003e\n\u003cli\u003eLockable Enclosure: Provides secure installation in a durable metal cabinet.\u003c\/li\u003e\n\u003cli\u003eVersatile Applications: Supports notification, auxiliary, and system expansion circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PSE-6E delivers the reliability and precision required for remote power and battery charging in Notifier fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105156473088,"sku":"PSE-6E","price":929.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_0d7ba2da-f1bb-4205-a99f-90f8358d2095.webp?v=1785541521"},{"product_id":"notifier-hpff12cm-12a-24v-fire-rated-power-supply-for-nac-and-auxiliary-circuits","title":"Notifier HPFF12CM 12A 24V Fire Rated Power Supply for NAC and Auxiliary Circuits","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier HPFF12CM is a 12-amp, 24VDC fire-rated power supply designed for use with Notifier fire alarm and emergency communication systems. It provides regulated output for notification appliance circuits (NACs) and auxiliary power, ensuring reliable system operation and supervision.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 539.032px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eHPFF12CM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eFire Alarm Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eNAC Expander \/ Fire-Rated Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e24 VDC Regulated and Filtered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 39.1875px;\"\u003e12.0 A Combined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eNAC Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e4 Supervised Outputs, 3.0 A Each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e24 VDC, 2.0 A Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003ePrimary Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 39.1875px;\"\u003e\u003cstrong\u003eBattery Charger Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 39.1875px;\"\u003eUp to Two 12 V, 26 Ah Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eCircuit Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eClass B (Style Y) or Class A (Style Z)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 39.1875px;\"\u003e\u003cstrong\u003eSynchronization Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 39.1875px;\"\u003eSystem Sensor, Gentex, Cooper-Wheelock, Faraday, Amseco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eChassis Mount for Notifier Equipment Enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 10px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 10px;\"\u003eApprox. 7.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About HPFF12CM\u003c\/h4\u003e\n\u003cp\u003eThe HPFF12CM is part of Notifier’s HPFF12 Series of notification appliance circuit expanders and auxiliary power supplies, built for high-performance fire alarm and life safety systems. It delivers a total output current of 12 amps across four Class B or two Class A NACs, each rated for up to 3 amps. Operating from 120VAC or 240VAC input, it features a fully regulated 24VDC output and includes battery charging capacity for up to two 12AH sealed lead-acid batteries within the cabinet. The HPFF12CM can operate as a standalone power supply or as a NAC expander under panel supervision, providing dependable power distribution in commercial, institutional, and industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Output Power: Provides up to 12A total output at 24VDC for notification appliances.\u003c\/li\u003e\n\u003cli\u003eMultiple NAC Circuits: Four 3A circuits configurable as Class A or Class B.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Power Output: 2A continuous regulated output under all conditions.\u003c\/li\u003e\n\u003cli\u003eBattery Charging: Supports up to two 12AH batteries internally; charges up to 26AH externally.\u003c\/li\u003e\n\u003cli\u003eDual Input Options: Operates on 120VAC\/60Hz or 240VAC\/50Hz input.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: Monitors AC failure, battery trouble, and NAC faults.\u003c\/li\u003e\n\u003cli\u003eCompact Cabinet Design: Red enclosure sized to hold internal batteries.\u003c\/li\u003e\n\u003cli\u003eTemperature Range: Operates from 32°F to 120°F (0°C to 49°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HPFF12CM delivers the reliability and precision required for powering fire alarm notification circuits and auxiliary devices.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105156571392,"sku":"HPFF12CM","price":2019.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/GW-F1P4-9626_450x450_7008c331-f430-493d-b529-d037d001a69e.jpg?v=1785541525"},{"product_id":"mps-24aepca-notifier-24vdc-fire-alarm-power-supply-and-battery-charger","title":"MPS-24AEPCA | Notifier 24VDC Fire Alarm Power Supply and Battery Charger","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier MPS-24AEPCA is a regulated 24V DC power supply designed for use in Notifier fire alarm control systems. It provides reliable system power and battery charging capabilities for auxiliary circuits, control modules, and system electronics.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 499.845px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003ePower Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eMPS-24AEPCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eFire Alarm Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eRegulated power supply and battery charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e24VDC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e120\/240VAC (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eFactory-rated for Notifier panel application (typically 6–8A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eIntegrated, automatic charge supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 39.1875px;\"\u003e\u003cstrong\u003eBackup Battery Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 39.1875px;\"\u003eSealed lead-acid batteries (up to 26AH, model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eFault Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eAC loss, battery fault, ground fault, overcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eNotifier fire alarm control panels and expanders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eProvides main or auxiliary power for system operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003ePanel-integrated power module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 10px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 10px;\"\u003eCommercial, institutional, and industrial fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e32°F–120°F (0°C–49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e10%–93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eUL listed, NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003eStandard Notifier module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.2398%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.5409%; height: 19.5938px;\"\u003e5 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About MPS-24AEPCA\u003c\/h4\u003e\n\u003cp\u003eThe MPS-24AEPCA is part of Notifier’s MPS Series power supplies, engineered to support a range of Notifier fire alarm and emergency communication panels. It delivers 24VDC regulated output for system operation and notification circuits, while simultaneously charging backup batteries to maintain uninterrupted power. Built for long-term reliability, the MPS-24AEPCA features automatic battery supervision, AC fail detection, and fault reporting through the panel. Its compact, field-replaceable design ensures simplified servicing and integration across compatible Notifier systems in commercial, institutional, and industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRegulated 24VDC Output: Provides clean, stable power for system electronics and NACs.\u003c\/li\u003e\n\u003cli\u003eIntegrated Battery Charger: Maintains and supervises standby batteries for reliable backup.\u003c\/li\u003e\n\u003cli\u003eNotifier Compatibility: Designed for use with Notifier control panels and power expanders.\u003c\/li\u003e\n\u003cli\u003eFault Monitoring: Supervises AC loss, battery trouble, and output conditions.\u003c\/li\u003e\n\u003cli\u003eHigh Reliability: Delivers dependable power in fire alarm and life safety applications.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Simplifies installation and replacement within compatible panels.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Complies with industry standards for life safety power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MPS-24AEPCA delivers the reliability and precision required for powering and maintaining Notifier fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105156604160,"sku":"MPS-24AEPCA","price":3317.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_6c0e0434-b259-41ed-b181-99a659a4d8d2.webp?v=1785541526"}],"url":"https:\/\/alotechparts.com\/collections\/notifier-parts.oembed","provider":"Alo Tech Solutions","version":"1.0","type":"link"}