{"title":"General Electric PDUs \u0026 UPS","description":"\u003cp\u003eGeneral Electric PDUs \u0026amp; UPS from Alo Tech: 48 products — rack PDUs, UPS systems and replacement batteries, circuit breakers, contactors and power distribution. Popular families include THHQB2150, TFK236175, EZSFHA36AT0250, THED136045WL, TEC36015. Every unit ships worldwide DDP (Delivered Duty Paid) — duties and taxes are included, so there are no surprises at customs. B2B buyers get a formal quote within 24 hours and can pay by purchase order.\u003c\/p\u003e\u003cp\u003eNeed a part that is not listed? We source across the full General Electric PDUs \u0026amp; UPS catalogue — \u003ca href=\"\/pages\/contact-us\"\u003esend us the part number\u003c\/a\u003e and we will confirm availability and lead time.\u003c\/p\u003e\u003cp class=\"seo-links\"\u003eBrowse: \u003ca href=\"\/collections\/general-electric-parts\"\u003eAll General Electric parts\u003c\/a\u003e · \u003ca href=\"\/collections\/pdu-ups-power-distribution\"\u003eAll PDUs \u0026amp; UPS\u003c\/a\u003e · \u003ca href=\"\/collections\/ge-speedtronic-turbine-control-boards\"\u003eGeneral Electric turbine control boards\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"general-electric-ads36060hdfp-3-pole-panel-board-switch-60a-600v-spectra-series","title":"General Electric ADS36060HDFP 3 Pole Panel Board Switch 60A 600V Spectra Series","description":"\u003ch4 data-end=\"74\" data-start=\"57\"\u003eDescription\u003c\/h4\u003e\n\u003cp data-end=\"508\" data-start=\"75\"\u003eThe General Electric ADS36060HDFP panel board switch is a 3-pole switching device designed for feeder and branch circuit protection in commercial and industrial electrical systems. It supports 3-phase applications with a 600 V rating, 60 A capacity, and a 200kA interrupt rating at 480V for high fault-current environments. Designed for use with Spectra Series switchboards, the switch features a panel-mounted dual\/twin configuration for reliable power distribution control.\u003c\/p\u003e\n\u003cp data-end=\"508\" data-start=\"75\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"508\" data-start=\"75\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"508\" data-start=\"75\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eADS36060HDFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003ePanel Board Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eSpectra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eADS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eADS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003e200kA@480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eDual\/Twin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eSpectra Series Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eNEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003eFeeder and Branch Circuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003e5 x 10 x 8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.1184%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6623%;\"\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-end=\"508\" data-start=\"75\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"533\" data-start=\"510\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eADS36060HDFP\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1165\" data-start=\"534\"\u003eThe ADS36060HDFP is a Spectra Series panel board switch manufactured by General Electric and designed for high-performance circuit switching and protection applications. This ADS frame switch features a 3-pole configuration with support for 3-phase electrical systems operating up to 600 V. Engineered for integration with Spectra Series switchboards, the unit is commonly used in commercial facilities, industrial plants, and service entrance installations where dependable feeder and branch circuit isolation is required. The switch includes a 200kA interrupt rating at 480V and is certified to UL and CSA standards for safe operation in panel-mounted electrical distribution assemblies.\u003c\/p\u003e\n\u003cp data-end=\"1185\" data-start=\"1167\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2186\" data-start=\"1186\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1195\" data-end=\"1982\"\u003e\n\u003cli data-section-id=\"f4m2bw\" data-start=\"1195\" data-end=\"1297\"\u003eHigh Interrupt Capacity: Rated at 200kA at 480V for protection in high fault-current environments.\u003c\/li\u003e\n\u003cli data-section-id=\"9dv660\" data-start=\"1298\" data-end=\"1391\"\u003e3-Pole Configuration: Supports balanced switching and isolation in 3-phase power systems.\u003c\/li\u003e\n\u003cli data-section-id=\"q8yeci\" data-start=\"1392\" data-end=\"1490\"\u003e600 V Rating: Designed for medium-voltage commercial and industrial distribution applications.\u003c\/li\u003e\n\u003cli data-section-id=\"14ckrcn\" data-start=\"1491\" data-end=\"1592\"\u003eSpectra Series Compatibility: Suitable for use with General Electric Spectra Series switchboards.\u003c\/li\u003e\n\u003cli data-section-id=\"haa2bp\" data-start=\"1593\" data-end=\"1687\"\u003eDual\/Twin Configuration: Provides flexible installation and switching arrangement options.\u003c\/li\u003e\n\u003cli data-section-id=\"1hh7y0n\" data-start=\"1688\" data-end=\"1774\"\u003ePanel Mount Design: Engineered for secure integration into panel board assemblies.\u003c\/li\u003e\n\u003cli data-section-id=\"12vqgxh\" data-start=\"1775\" data-end=\"1860\"\u003eUL and CSA Approved: Meets recognized North American electrical safety standards.\u003c\/li\u003e\n\u003cli data-section-id=\"mlhu5e\" data-start=\"1861\" data-end=\"1982\"\u003eCommercial and Industrial Application: Intended for feeder and branch circuit protection in service entrance systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1984\" data-end=\"2129\"\u003eThe ADS36060HDFP delivers the reliability and precision required for commercial and industrial power distribution and circuit protection systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104732389632,"sku":"ADS36060HDFP","price":5878.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_cb588842-d453-426f-9a50-f1b754fbd1a3.webp?v=1785531584"},{"product_id":"general-electric-thhqb2150-50-amp-2-pole-q-line-circuit-breaker-22ka-interrupting-rating","title":"General Electric THHQB2150 50 Amp 2-Pole Q-Line Circuit Breaker, 22kA Interrupting Rating","description":"\u003ch4 data-start=\"52\" data-end=\"71\"\u003e\u003cspan role=\"text\"\u003eDescription\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-start=\"72\" data-end=\"496\"\u003eThe THHQB2150 is a 50 Amp, 2-pole Q-Line circuit breaker from General Electric, engineered for reliable electrical protection in both residential and commercial settings. It provides robust protection with a 22kA interrupting rating, ensuring safety against short circuits and overloads. Designed for use in load centers and lighting panels, it features a compact, thermal-magnetic construction for superior performance.\u003c\/p\u003e\n\u003cp data-start=\"72\" data-end=\"496\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"72\" data-end=\"496\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"72\" data-end=\"496\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eTHHQB2150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eQ-Line Miniature Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003e120\/240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003e22 kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eNon-Interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eLong-time Fixed, Instantaneous Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eReverse Feed Compatible\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eHACR Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eCurrent Metering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003eQ-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.5182%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1692%; height: 19.5938px;\"\u003e0.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"72\" data-end=\"496\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"72\" data-end=\"496\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"498\" data-end=\"523\"\u003e\u003cspan role=\"text\"\u003eInformation About THHQB2150\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-start=\"524\" data-end=\"1120\"\u003eThe THHQB2150 is a bolt-on circuit breaker from the Q-Line series by General Electric, specifically designed to protect electrical circuits in both residential and commercial environments. With its non-interchangeable trip style and fixed long-time and instantaneous trip functions, it offers stable and reliable operation. This breaker is compatible with 120V and 240V AC systems, and supports reverse feed for greater installation flexibility. The THHQB2150 is ideal for applications requiring high interruption capacity, such as lighting panels, HVAC systems, and general load centers.\u003c\/p\u003e\n\u003cp data-start=\"1122\" data-end=\"1142\"\u003e\u003cstrong\u003e\u003cspan role=\"text\"\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1143\" data-end=\"2506\"\u003e\n\u003cli data-start=\"1143\" data-end=\"1256\"\u003eAmperage Rating: 50 Amps: Provides reliable protection for circuits with a maximum current draw of 50 amps.\u003c\/li\u003e\n\u003cli data-start=\"1257\" data-end=\"1335\"\u003ePoles: 2: Offers a 2-pole configuration, suitable for 240V applications.\u003c\/li\u003e\n\u003cli data-start=\"1336\" data-end=\"1493\"\u003eInterrupting Rating: 22kAIC: Capable of interrupting high fault currents of up to 22,000 amps, ensuring safe operation in the event of a short circuit.\u003c\/li\u003e\n\u003cli data-start=\"1494\" data-end=\"1595\"\u003eVoltage Compatibility: 120\/240V AC: Works with both 120V and 240V AC systems for versatile use.\u003c\/li\u003e\n\u003cli data-start=\"1596\" data-end=\"1725\"\u003eNon-Interchangeable Trip Style: The breaker features a fixed trip style for reliable performance and consistent protection.\u003c\/li\u003e\n\u003cli data-start=\"1726\" data-end=\"1869\"\u003eTrip Function: Long-time Fixed, Instantaneous Fixed: Provides fixed long-time delay and instantaneous trip functions for enhanced safety.\u003c\/li\u003e\n\u003cli data-start=\"1870\" data-end=\"1974\"\u003eReverse Feed Compatible: Supports reverse feed applications for added flexibility in installation.\u003c\/li\u003e\n\u003cli data-start=\"1975\" data-end=\"2070\"\u003eHACR Marking: Rated for heating, air conditioning, and refrigeration (HACR) applications.\u003c\/li\u003e\n\u003cli data-start=\"2071\" data-end=\"2176\"\u003eQuick-make \/ Quick-break Mechanism: Ensures rapid and efficient disconnection during a fault event.\u003c\/li\u003e\n\u003cli data-start=\"2177\" data-end=\"2290\"\u003eCompact Design: The one-inch wide per pole design fits easily into most electrical panels and load centers.\u003c\/li\u003e\n\u003cli data-start=\"2291\" data-end=\"2393\"\u003eNo Protective Relays: Simple and efficient design with no need for additional protective relays.\u003c\/li\u003e\n\u003cli data-start=\"2394\" data-end=\"2506\"\u003eNo Current Metering: This breaker does not provide current metering but ensures reliable fault protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2508\" data-end=\"2641\"\u003eThe THHQB2150 delivers the reliability and precision required for high-performance residential and commercial electrical systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104734159104,"sku":"THHQB2150","price":171.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_b11b47be-e4a4-459f-81ec-83c7c958aa00.webp?v=1785531622"},{"product_id":"general-electric-ads32400hbfp-400-a-240-v-3-phase-fused-panelboard-disconnect","title":"General Electric ADS32400HBFP 400 A 240 V 3-Phase Fused Panelboard Disconnect","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"429\"\u003eThe General Electric ADS32400HBFP is a 400 A, 240 V 3‑pole fused panelboard disconnect switch designed for commercial and industrial electrical distribution. This unit provides reliable overcurrent protection and manual circuit disconnection. It is suitable for use with Spectra™ series switchboards and other electrical control applications.\u003c\/p\u003e\n\u003cp data-start=\"21\" data-end=\"429\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"21\" data-end=\"429\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable height=\"434\" style=\"width: 90.7609%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eADS32400HBFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003ePanelboard Disconnect Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eADS \/ Spectra™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003ePanel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 39.1875px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 39.1875px;\"\u003e200 kA @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eNEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Wires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eSpectra™ Switchboards, Electrical Distribution and Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003e10 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003eType ADS Fused\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.6022%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.156%; height: 19.5938px;\"\u003e85 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eADS32400HBFP\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1025\" data-start=\"531\"\u003eThe ADS32400HBFP is part of GE’s ADS series, engineered for safe and dependable operation in high-current environments. It features a 3-pole, single-configuration design with a 200 kA interrupting rating at 480 V. The panelboard disconnect is designed for panel mounting and includes NEMA 1 enclosures for indoor installations. Key technologies include fused protection, robust construction, and compatibility with Spectra™ series switchboards for commercial electrical distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1052\" data-end=\"1841\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"997\" data-end=\"1535\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1008\" data-end=\"1696\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1042\" data-end=\"1540\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"941\" data-end=\"1455\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"969\" data-end=\"1446\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1100\" data-end=\"1748\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1045\" data-end=\"1678\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1460\" data-start=\"947\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1412\" data-start=\"934\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1450\" data-start=\"958\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1598\" data-start=\"1021\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1014\" data-end=\"1662\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1741\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"976\" data-end=\"1776\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1055\" data-end=\"1769\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1013\" data-end=\"1532\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1401\" data-start=\"924\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1548\" data-start=\"1040\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1665\" data-start=\"1061\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1659\" data-start=\"1077\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1597\" data-start=\"1077\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1603\" data-start=\"1037\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1668\" data-start=\"1061\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1523\" data-start=\"980\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1625\" data-start=\"1085\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1674\" data-start=\"1052\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1468\" data-start=\"973\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1483\" data-start=\"968\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1551\" data-start=\"1019\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1556\" data-start=\"1063\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1669\" data-start=\"1108\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1087\" data-end=\"1671\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1012\" data-end=\"1522\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1114\" data-end=\"1676\"\u003e\n\u003cli data-section-id=\"xqkwqm\" data-start=\"1114\" data-end=\"1206\"\u003eSeries ADS: Part of GE’s Spectra™ series for industrial and commercial applications.\u003c\/li\u003e\n\u003cli data-section-id=\"2dgbsr\" data-start=\"1207\" data-end=\"1266\"\u003eAmperage Rating: 400 A for high-current protection.\u003c\/li\u003e\n\u003cli data-section-id=\"1jzpiha\" data-start=\"1267\" data-end=\"1333\"\u003eVoltage Rating: 240 V AC for standard three-phase systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1r32esi\" data-start=\"1334\" data-end=\"1399\"\u003ePoles: 3-pole configuration for full three-phase control.\u003c\/li\u003e\n\u003cli data-section-id=\"1k64d78\" data-start=\"1400\" data-end=\"1478\"\u003eInterrupting Rating: 200 kA @ 480 V for high short-circuit protection.\u003c\/li\u003e\n\u003cli data-section-id=\"6vqhik\" data-start=\"1479\" data-end=\"1539\"\u003eMounting Type: Panel-mounted for secure integration.\u003c\/li\u003e\n\u003cli data-section-id=\"19pxclz\" data-start=\"1540\" data-end=\"1607\"\u003eFused Protection: Type ADS fused design for circuit safety.\u003c\/li\u003e\n\u003cli data-section-id=\"1azrxew\" data-start=\"1608\" data-end=\"1676\"\u003eNEMA 1 Enclosure: Provides indoor protection and durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1678\" data-end=\"1800\"\u003eThe ADS32400HBFP delivers reliable overcurrent protection and safe manual disconnection for industrial electrical systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104740057344,"sku":"ADS32400HBFP","price":11023.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ADS32400HBFP-new-1.jpg?v=1785531735"},{"product_id":"general-electric-tfk236175-175a-3-pole-600v-molded-case-circuit-breaker","title":"General Electric TFK236175 175A 3-Pole 600V Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"429\" data-start=\"21\"\u003eThe General Electric TFK236175 is a 175 Amp, 3-pole molded case circuit breaker designed for three-phase electrical systems. It provides reliable protection for circuits up to 600 VAC or 250 VDC. This breaker is compatible with GE A-Series panelboards, switchboards, motor control centers, and enclosures.\u003c\/p\u003e\n\u003ch2 data-end=\"457\" data-start=\"431\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 90.7609%; height: 293.907px;\" height=\"434\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eGeneral Electric \/ ABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eTFK236175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eTFK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e175 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e240VAC, 480VAC, 600VAC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eThree-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eFixed Thermal, Adjustable Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e4 AWG – 300 kcmil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eOptional Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eCSA C22.2 No. 5, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eCSA, HACR, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eConstruction Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003eHACR Rated, Interchangeable Trip Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.819%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9391%;\"\u003e10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eTFK236175\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1028\" data-start=\"458\"\u003eThe TFK236175 is part of GE’s TFK series of molded case circuit breakers, engineered for industrial and commercial applications. It features bolt-on mounting with lug terminals for secure installation. The breaker uses a thermal-magnetic trip mechanism with long-time and instantaneous functionality and supports wire sizes from 4 AWG to 300 kcmil. Optional accessories include shunt trip, auxiliary switch, undervoltage release, and alarm switch for flexible installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1841\" data-start=\"1052\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1535\" data-start=\"997\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1696\" data-start=\"1008\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1540\" data-start=\"1042\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1455\" data-start=\"941\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1446\" data-start=\"969\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1748\" data-start=\"1100\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1678\" data-start=\"1045\"\u003e\n\u003cli data-end=\"1126\" data-start=\"1045\" data-section-id=\"1sm9vy2\"\u003e\n\u003cstrong data-end=\"1057\" data-start=\"1047\"\u003eSeries\u003c\/strong\u003e: TFK Series molded case breaker for industrial and commercial use.\u003c\/li\u003e\n\u003cli data-end=\"1187\" data-start=\"1127\" data-section-id=\"13ms4e8\"\u003e\n\u003cstrong data-end=\"1138\" data-start=\"1129\"\u003ePoles\u003c\/strong\u003e: 3-pole configuration for three-phase systems.\u003c\/li\u003e\n\u003cli data-end=\"1245\" data-start=\"1188\" data-section-id=\"1mx07tu\"\u003e\n\u003cstrong data-end=\"1208\" data-start=\"1190\"\u003eCurrent Rating\u003c\/strong\u003e: 175 Amp continuous load capacity.\u003c\/li\u003e\n\u003cli data-end=\"1312\" data-start=\"1246\" data-section-id=\"11qx38d\"\u003e\n\u003cstrong data-end=\"1266\" data-start=\"1248\"\u003eVoltage Rating\u003c\/strong\u003e: 240VAC, 480VAC, 600VAC, 250VDC compatible.\u003c\/li\u003e\n\u003cli data-end=\"1375\" data-start=\"1313\" data-section-id=\"1tzhr21\"\u003e\n\u003cstrong data-end=\"1333\" data-start=\"1315\"\u003eMounting Style\u003c\/strong\u003e: Bolt-on for secure panel installation.\u003c\/li\u003e\n\u003cli data-end=\"1459\" data-start=\"1376\" data-section-id=\"1r2b2rb\"\u003e\n\u003cstrong data-end=\"1396\" data-start=\"1378\"\u003eTrip Mechanism\u003c\/strong\u003e: Thermal-magnetic for overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-end=\"1546\" data-start=\"1460\" data-section-id=\"1bujkk0\"\u003e\n\u003cstrong data-end=\"1479\" data-start=\"1462\"\u003eTrip Function\u003c\/strong\u003e: Long-time and instantaneous (LI) with adjustable magnetic trip.\u003c\/li\u003e\n\u003cli data-end=\"1585\" data-start=\"1547\" data-section-id=\"ry2hxr\"\u003e\n\u003cstrong data-end=\"1563\" data-start=\"1549\"\u003eWire Range\u003c\/strong\u003e: 4 AWG – 300 kcmil.\u003c\/li\u003e\n\u003cli data-end=\"1678\" data-start=\"1586\" data-section-id=\"io1krs\"\u003e\n\u003cstrong data-end=\"1609\" data-start=\"1588\"\u003eOptional Features\u003c\/strong\u003e: Shunt trip, auxiliary switch, undervoltage release, alarm switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1804\" data-start=\"1680\"\u003eThe TFK236175 delivers the reliability and precision required for high-current industrial and commercial circuit protection.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104743006464,"sku":"TFK236175","price":995.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_af7029b2-c4bc-4a3f-9cc8-bd9a30344525.webp?v=1785531812"},{"product_id":"general-electric-ted136yt150-150a-3-pole-600v-molded-case-switch","title":"General Electric TED136YT150 150A 3-Pole 600V Molded Case Switch","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"429\"\u003eThe General Electric TED136YT150 is a 150 Amp, 3-pole molded case switch designed for three-phase electrical systems. It provides non-automatic protection for circuits operating up to 600 VAC or 500 VDC. This switch is compatible with GE A-Series and Spectra Series panelboards, ensuring secure and reliable installation.\u003c\/p\u003e\n\u003ch2 data-start=\"431\" data-end=\"457\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable height=\"434\" style=\"width: 90.7609%; height: 293.907px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eMolded Case Circuit Breakers \/ 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eTED136YT150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eMolded Case Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e150 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e240VAC, 480VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eThree-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eMagnetic Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e3 AWG – 3\/0 AWG (Cu), 1 AWG – 3\/0 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e18kA @ 480V, 18kA @ 240\/480VAC, 14kA @ 600VAC, 10kA @ 250\/500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eOptional Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator, Padlock Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eUL 489, NEMA AB 1, CSA C22.2 No. 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eConstruction Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003eNon-Automatic, Molded Case Switch, Feed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e6.75 x 4.25 x 4.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.7961%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9621%;\"\u003e5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eTED136YT150\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"458\" data-end=\"1028\"\u003eThe TED136YT150 is part of GE’s TED series of molded case switches, built for industrial and commercial applications. It features a bolt-on mounting style with lug terminals for feed-thru connections. The switch uses a magnetic-only trip mechanism with fixed settings and accommodates wire sizes from 3 AWG to 3\/0 AWG for copper and 1 AWG to 3\/0 AWG for aluminum. Optional features include shunt trip, auxiliary switch, undervoltage release, bell alarm, motor operator, and padlock attachment for flexible installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1052\" data-end=\"1841\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"997\" data-end=\"1535\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1008\" data-end=\"1696\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1042\" data-end=\"1540\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"941\" data-end=\"1455\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"969\" data-end=\"1446\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1100\" data-end=\"1748\"\u003e\n\u003cli data-section-id=\"11o9dcr\" data-start=\"1100\" data-end=\"1165\"\u003e\n\u003cstrong data-start=\"1102\" data-end=\"1112\"\u003eSeries\u003c\/strong\u003e: TED Series molded case switch for industrial use.\u003c\/li\u003e\n\u003cli data-section-id=\"13ms4e8\" data-start=\"1166\" data-end=\"1226\"\u003e\n\u003cstrong data-start=\"1168\" data-end=\"1177\"\u003ePoles\u003c\/strong\u003e: 3-pole configuration for three-phase systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1gik6xx\" data-start=\"1227\" data-end=\"1284\"\u003e\n\u003cstrong data-start=\"1229\" data-end=\"1247\"\u003eCurrent Rating\u003c\/strong\u003e: 150 Amp continuous load capacity.\u003c\/li\u003e\n\u003cli data-section-id=\"1qemod1\" data-start=\"1285\" data-end=\"1359\"\u003e\n\u003cstrong data-start=\"1287\" data-end=\"1305\"\u003eVoltage Rating\u003c\/strong\u003e: 240VAC, 480VAC, 600VAC, 250VDC, 500VDC compatible.\u003c\/li\u003e\n\u003cli data-section-id=\"1tzhr21\" data-start=\"1360\" data-end=\"1422\"\u003e\n\u003cstrong data-start=\"1362\" data-end=\"1380\"\u003eMounting Style\u003c\/strong\u003e: Bolt-on for secure panel installation.\u003c\/li\u003e\n\u003cli data-section-id=\"12l3uw2\" data-start=\"1423\" data-end=\"1485\"\u003e\n\u003cstrong data-start=\"1425\" data-end=\"1443\"\u003eTrip Mechanism\u003c\/strong\u003e: Magnetic-only with fixed trip setting.\u003c\/li\u003e\n\u003cli data-section-id=\"1rvuj9b\" data-start=\"1486\" data-end=\"1549\"\u003e\n\u003cstrong data-start=\"1488\" data-end=\"1502\"\u003eWire Range\u003c\/strong\u003e: 3 AWG – 3\/0 AWG (Cu), 1 AWG – 3\/0 AWG (Al).\u003c\/li\u003e\n\u003cli data-section-id=\"aepe5e\" data-start=\"1550\" data-end=\"1621\"\u003e\n\u003cstrong data-start=\"1552\" data-end=\"1569\"\u003eCompatibility\u003c\/strong\u003e: Fits GE A-Series and Spectra Series panelboards.\u003c\/li\u003e\n\u003cli data-section-id=\"icqk41\" data-start=\"1622\" data-end=\"1748\"\u003e\n\u003cstrong data-start=\"1624\" data-end=\"1645\"\u003eOptional Features\u003c\/strong\u003e: Shunt trip, auxiliary switch, undervoltage release, bell alarm, motor operator, padlock attachment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1750\" data-end=\"1860\"\u003eThe TED136YT150 delivers the reliability and precision required for industrial and commercial circuit control.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104743039232,"sku":"TED136YT150","price":4261.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/general-electric-ge-ted136yt150-3-pole-150-amp-600v-circuit-breaker-front-600.jpg?v=1785531812"},{"product_id":"general-electric-ezsfha36at0250-250a-3-pole-circuit-breaker-600vac-spectra-rms-solid-state","title":"General Electric EZSFHA36AT0250 250A 3-Pole Circuit Breaker 600VAC Spectra RMS Solid-State","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"442\"\u003eThe General Electric EZSFHA36AT0250 is a solid-state molded case circuit breaker designed for advanced protection in industrial and commercial power distribution systems. Rated at 250 amps and 600 VAC, it provides precise overcurrent protection using RMS sensing technology. This breaker is engineered for reliable operation in three-phase applications requiring accurate fault detection and adjustable trip functionality.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZSFHA36AT0250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra RMS (SFHA Frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35kA @ 480V \/ 22kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-State RMS Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Short-Time, Instantaneous (LSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, CE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial and commercial distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About EZSFHA36AT0250\u003c\/h4\u003e\n\u003cp data-start=\"475\" data-end=\"1062\"\u003eThe EZSFHA36AT0250 is part of General Electric’s Spectra RMS series, known for its digital solid-state trip systems and high-performance protection capabilities. It features a rugged molded case construction combined with electronic trip technology that accurately responds to both sinusoidal and non-sinusoidal currents. The breaker supports field-installable rating plugs, allowing flexible current adjustment without replacing the unit. Designed for bolt-on mounting, it integrates seamlessly into Spectra panelboards and switchgear for demanding electrical distribution environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1090\" data-end=\"1841\"\u003e\n\u003cli data-start=\"1090\" data-end=\"1193\"\u003eSolid-State Trip System: Uses RMS sensing technology for precise current monitoring and protection.\u003c\/li\u003e\n\u003cli data-start=\"1194\" data-end=\"1282\"\u003e250 Amp Rating: Suitable for medium to high-load industrial and commercial circuits.\u003c\/li\u003e\n\u003cli data-start=\"1283\" data-end=\"1364\"\u003e600 VAC Capacity: Designed for high-voltage three-phase distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1365\" data-end=\"1457\"\u003e3-Pole Configuration: Provides full protection for three-phase electrical installations.\u003c\/li\u003e\n\u003cli data-start=\"1458\" data-end=\"1559\"\u003eAdjustable Protection Functions: Includes long-time, short-time, and instantaneous trip settings.\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1640\"\u003eHigh Interrupt Rating: Rated up to 35kA at 480V for safe fault interruption.\u003c\/li\u003e\n\u003cli data-start=\"1641\" data-end=\"1729\"\u003eBolt-On Mounting: Ensures secure installation in panelboards and switchgear systems.\u003c\/li\u003e\n\u003cli data-start=\"1730\" data-end=\"1841\"\u003eField-Replaceable Rating Plug: Allows flexible adjustment of current ratings without replacing the breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1843\" data-end=\"1998\"\u003eThe EZSFHA36AT0250 delivers the reliability and precision required for advanced circuit protection in industrial and commercial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104743694592,"sku":"EZSFHA36AT0250","price":1774.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-17_23.15.09.png?v=1785531831"},{"product_id":"general-electric-thed136045wl-45a-3-pole-molded-case-circuit-breaker-600vac-e-150-series","title":"General Electric THED136045WL 45A 3-Pole Molded Case Circuit Breaker 600VAC E-150 Series","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"409\"\u003eThe General Electric THED136045WL is a molded case circuit breaker designed to provide reliable overcurrent protection in commercial and industrial electrical systems. Rated at 45 amps and 600 volts AC, it ensures safe interruption of overload and short-circuit conditions in three-phase circuits. This breaker is built for consistent performance in panelboards and distribution equipment.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED136045WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru (Line \u0026amp; Load Lugs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13°F to 158°F (-25°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial and commercial distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THED136045WL\u003c\/h4\u003e\n\u003cp data-start=\"442\" data-end=\"974\"\u003eThe THED136045WL is part of General Electric’s E-150 series, engineered for medium-duty power distribution and control applications. It features a molded insulated case construction that enhances durability and electrical safety under demanding operating conditions. The breaker utilizes a thermal-magnetic trip unit, combining long-time overload protection with instantaneous short-circuit response. Designed with feed-thru capability and lug terminals, it integrates easily into industrial switchgear and panelboard installations.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1002\" data-end=\"1656\"\u003e\n\u003cli data-start=\"1002\" data-end=\"1089\"\u003e45 Amp Rating: Suitable for moderate-load circuit protection in industrial systems.\u003c\/li\u003e\n\u003cli data-start=\"1090\" data-end=\"1167\"\u003e600 VAC Operation: Designed for higher-voltage distribution applications.\u003c\/li\u003e\n\u003cli data-start=\"1168\" data-end=\"1239\"\u003e3-Pole Configuration: Provides protection for three-phase circuits.\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1325\"\u003eThermal-Magnetic Trip: Combines long-time and instantaneous protection functions.\u003c\/li\u003e\n\u003cli data-start=\"1326\" data-end=\"1410\"\u003e25kA Interrupt Rating: Ensures safe interruption of high fault currents at 480V.\u003c\/li\u003e\n\u003cli data-start=\"1411\" data-end=\"1490\"\u003eFeed-Thru Design: Supports flexible wiring and reverse-feed configurations.\u003c\/li\u003e\n\u003cli data-start=\"1491\" data-end=\"1570\"\u003eLug Terminal Connections: Enables secure line and load wiring installation.\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1656\"\u003eE-150 Series Construction: Compatible with GE panelboards and switchgear systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1658\" data-end=\"1807\"\u003eThe THED136045WL delivers the reliability and precision required for circuit protection in industrial and commercial power distribution environments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104743923968,"sku":"THED136045WL","price":693.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-17_23.08.39.png?v=1785531832"},{"product_id":"general-electric-tec36015-15a-3-pole-molded-case-circuit-breaker-600vac-magnetic-trip","title":"General Electric TEC36015 15A 3-Pole Molded Case Circuit Breaker 600VAC Magnetic Trip","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"399\"\u003eThe General Electric TEC36015 is a molded case circuit breaker designed for motor protection and short-circuit interruption in industrial electrical systems. Rated at 15 amps and 600 volts AC, it provides instantaneous magnetic-only trip protection for three-phase applications. This breaker is engineered for fast fault response and reliable operation in motor control circuits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9251%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eTEC36015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eTEC (Mag-Break)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003e10kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eMagnetic Only (Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eFeed-Thru (Line \u0026amp; Load Lugs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eMotor circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.9259%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7296%;\"\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TEC36015\u003c\/h4\u003e\n\u003cp data-start=\"432\" data-end=\"1010\"\u003eThe TEC36015 is part of General Electric’s TEC series, also known as the Mag-Break line, designed specifically for motor circuit protection. It features a magnetic-only trip mechanism that responds instantly to short-circuit conditions without thermal delay. The breaker is built with a durable molded case and supports feed-thru connections, allowing flexible installation including reverse-feed applications. Commonly used in industrial and commercial environments, it integrates with GE distribution systems to protect motors and equipment requiring rapid fault interruption.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1038\" data-end=\"1644\"\u003e\n\u003cli data-start=\"1038\" data-end=\"1113\"\u003e15 Amp Rating: Designed for low-current motor and equipment protection.\u003c\/li\u003e\n\u003cli data-start=\"1114\" data-end=\"1187\"\u003e600 VAC Operation: Suitable for high-voltage industrial applications.\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1259\"\u003e3-Pole Configuration: Provides protection for three-phase circuits.\u003c\/li\u003e\n\u003cli data-start=\"1260\" data-end=\"1358\"\u003eMagnetic-Only Trip: Instantaneous response to short-circuit conditions without overload delay.\u003c\/li\u003e\n\u003cli data-start=\"1359\" data-end=\"1430\"\u003e10kA Interrupt Rating: Safely interrupts fault currents at 480 VAC.\u003c\/li\u003e\n\u003cli data-start=\"1431\" data-end=\"1509\"\u003eFeed-Thru Design: Supports reverse-fed and flexible wiring configurations.\u003c\/li\u003e\n\u003cli data-start=\"1510\" data-end=\"1569\"\u003eLug Terminals: Allows secure line and load connections.\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003eMag-Break Series: Optimized for motor circuit protection applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1646\" data-end=\"1776\"\u003eThe TEC36015 delivers the reliability and precision required for fast-acting motor circuit protection in industrial power systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104743989504,"sku":"TEC36015","price":1027.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-17_23.01.24.png?v=1785531835"},{"product_id":"general-electric-tfj236200wl-200a-3-pole-molded-case-circuit-breaker-600vac-f225-frame","title":"General Electric TFJ236200WL 200A 3-Pole Molded Case Circuit Breaker 600VAC F225 Frame","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"424\"\u003eThe General Electric TFJ236200WL is a molded case circuit breaker designed for reliable overcurrent protection in industrial and commercial power distribution systems. Rated at 200 amps and 600 volts AC, it ensures safe interruption of overload and fault conditions in three-phase circuits. This breaker is engineered for high-capacity applications requiring stable and consistent protection performance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFJ236200WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF225 Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable Thermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru (Line \u0026amp; Load Lugs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial and commercial distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TFJ236200WL\u003c\/h4\u003e\n\u003cp data-start=\"457\" data-end=\"1036\"\u003eThe TFJ236200WL is part of General Electric’s TFJ series within the F225 frame line, developed for heavy-duty electrical distribution systems. It features a molded case design with robust insulation and mechanical strength for long-term operational reliability. The breaker incorporates an adjustable thermal-magnetic trip unit, allowing fine-tuning of protection characteristics for specific load requirements. Designed for feed-thru connection with line and load lugs, it integrates easily into switchgear and panelboard systems used in industrial and commercial installations.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1064\" data-end=\"1750\"\u003e\n\u003cli data-start=\"1064\" data-end=\"1142\"\u003e200 Amp Rating: Suitable for high-load industrial and commercial circuits.\u003c\/li\u003e\n\u003cli data-start=\"1143\" data-end=\"1217\"\u003e600 VAC Operation: Supports higher-voltage power distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1218\" data-end=\"1300\"\u003e3-Pole Configuration: Provides protection for three-phase electrical networks.\u003c\/li\u003e\n\u003cli data-start=\"1301\" data-end=\"1411\"\u003eAdjustable Thermal-Magnetic Trip: Enables customization of overload and short-circuit protection settings.\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1490\"\u003eHigh Interrupt Capacity: Rated up to 22kA at 480 VAC for fault protection.\u003c\/li\u003e\n\u003cli data-start=\"1491\" data-end=\"1580\"\u003eFeed-Thru Connection: Includes line and load lugs for flexible wiring configurations.\u003c\/li\u003e\n\u003cli data-start=\"1581\" data-end=\"1663\"\u003eF225 Frame Design: Ensures compatibility with GE switchgear and panel systems.\u003c\/li\u003e\n\u003cli data-start=\"1664\" data-end=\"1750\"\u003eDurable Molded Case: Provides insulation and protection in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1752\" data-end=\"1894\"\u003eThe TFJ236200WL delivers the reliability and precision required for high-capacity circuit protection in industrial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744055040,"sku":"TFJ236200WL","price":939.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-17_22.56.28.png?v=1785531839"},{"product_id":"general-electric-thed136110-110a-3-pole-molded-case-circuit-breaker-600vac-e-150-series","title":"General Electric THED136110 110A 3-Pole Molded Case Circuit Breaker 600VAC E-150 Series","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"432\"\u003eThe General Electric THED136110 is a molded case circuit breaker designed to provide dependable overcurrent protection in commercial and industrial electrical systems. Rated at 110 amps and 600 volts AC, it ensures safe interruption of overloads and short-circuit conditions in three-phase applications. This breaker is engineered for consistent performance and secure installation in panelboards and switchgear.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED136110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489, ANSI C37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13°F to 158°F (-25°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THED136110\u003c\/h4\u003e\n\u003cp data-start=\"465\" data-end=\"995\"\u003eThe THED136110 is part of General Electric’s E-150 series, built for high-capacity power distribution systems requiring reliable protection. It features a rugged molded case design that supports long-term durability under electrical and thermal stress. The breaker uses a thermal-magnetic trip unit, combining inverse-time overload protection with instantaneous short-circuit interruption. Designed for bolt-on mounting, it integrates easily into GE panelboards and switchgear systems used in commercial and industrial facilities.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1023\" data-end=\"1660\"\u003e\n\u003cli data-start=\"1023\" data-end=\"1113\"\u003e110 Amp Rating: Supports medium-load protection in industrial and commercial circuits.\u003c\/li\u003e\n\u003cli data-start=\"1114\" data-end=\"1186\"\u003e600 VAC Operation: Suitable for higher-voltage distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1187\" data-end=\"1262\"\u003e3-Pole Configuration: Designed for three-phase electrical applications.\u003c\/li\u003e\n\u003cli data-start=\"1263\" data-end=\"1342\"\u003eThermal-Magnetic Trip: Provides both overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"1343\" data-end=\"1419\"\u003eBolt-On Mounting: Ensures secure and stable installation in panelboards.\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1496\"\u003e25kA Interrupt Rating: Safely interrupts high fault currents at 480 VAC.\u003c\/li\u003e\n\u003cli data-start=\"1497\" data-end=\"1579\"\u003eE-150 Series Design: Compatible with GE distribution equipment and switchgear.\u003c\/li\u003e\n\u003cli data-start=\"1580\" data-end=\"1660\"\u003eDurable Molded Case: Enhances electrical insulation and mechanical strength.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1662\" data-end=\"1819\"\u003eThe THED136110 delivers the reliability and precision required for circuit protection in demanding industrial and commercial power distribution environments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744153344,"sku":"THED136110","price":1043.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TED134_381b14ea-9bb6-4554-8213-654803adb2a8.jpg?v=1785531840"},{"product_id":"general-electric-teyd3030b-30a-3-pole-molded-case-circuit-breaker-480277vac-bolt-on","title":"General Electric TEYD3030B 30A 3-Pole Molded Case Circuit Breaker 480\/277VAC Bolt-On","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"436\"\u003eThe General Electric TEYD3030B is a three-pole molded case circuit breaker designed to provide reliable overcurrent protection in commercial and industrial electrical systems. Rated at 30 amps and suitable for 480\/277 VAC applications, it ensures safe interruption of overloads and short circuits. This breaker is engineered for secure bolt-on installation in panelboards requiring compact and dependable protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEYD3030B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEYD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEY (125A Frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480\/277 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA @ 480V \/ 65kA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TEYD3030B\u003c\/h4\u003e\n\u003cp data-start=\"469\" data-end=\"1023\"\u003eThe TEYD3030B is part of General Electric’s TEYD series, built on the TEY frame platform for use in lighting and distribution panelboards. It features a thermal-magnetic trip mechanism that combines long-time overload protection with instantaneous fault response. The breaker is constructed with a molded insulated case and incorporates a quick-make\/quick-break switching system for efficient circuit interruption. Designed for compatibility with GE panelboards, it is commonly deployed in three-phase systems across commercial and industrial facilities.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1051\" data-end=\"1720\"\u003e\n\u003cli data-start=\"1051\" data-end=\"1145\"\u003e30 Amp Rating: Designed for low to medium-load circuit protection in distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1146\" data-end=\"1228\"\u003e3-Pole Configuration: Provides protection for three-phase electrical circuits.\u003c\/li\u003e\n\u003cli data-start=\"1229\" data-end=\"1317\"\u003eThermal-Magnetic Trip: Combines overload and instantaneous short-circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1397\"\u003eBolt-On Mounting: Ensures secure installation in compatible GE panelboards.\u003c\/li\u003e\n\u003cli data-start=\"1398\" data-end=\"1476\"\u003eHigh Interrupt Capacity: Rated up to 25kA at 480 VAC for fault protection.\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1556\"\u003eCompact TEY Frame: Space-efficient design with one-inch per pole footprint.\u003c\/li\u003e\n\u003cli data-start=\"1557\" data-end=\"1637\"\u003eQuick-Make\/Break Mechanism: Enables rapid and reliable circuit interruption.\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1720\"\u003eVisible Trip Indicator: Allows easy status identification and troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1722\" data-end=\"1868\"\u003eThe TEYD3030B delivers the reliability and precision required for safe circuit protection in commercial and industrial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744317184,"sku":"TEYD3030B","price":521.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TEYD3030B-All-New-1_0ce91d9e-7e95-4330-886b-1dd0ead3ed23.jpg?v=1785531842"},{"product_id":"general-electric-fds36td100gd-100a-3-pole-molded-case-circuit-breaker-690vac-36ka","title":"General Electric FDS36TD100GD 100A 3-Pole Molded Case Circuit Breaker 690VAC 36kA","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"452\"\u003eThe General Electric FDS36TD100GD is a molded case circuit breaker designed to provide dependable overcurrent protection in industrial and commercial power distribution systems. Rated at 100 amps and capable of operating up to 690 VAC, it ensures safe interruption of fault currents in three-phase applications. This breaker is engineered for high interrupting capacity and reliable performance in demanding electrical environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFDS36TD100GD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFDS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 690 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial and commercial power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel \/ switchgear mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.73 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FDS36TD100GD\u003c\/h4\u003e\n\u003cp data-start=\"485\" data-end=\"1107\"\u003eThe FDS36TD100GD is part of General Electric’s FDS series of molded case circuit breakers, built for high-performance protection in low-voltage distribution systems. It features a robust insulated case design that supports safe operation under high fault conditions and elevated voltages. The breaker incorporates a thermal-magnetic trip unit, providing both inverse-time overload protection and instantaneous short-circuit interruption. Designed for compatibility with industrial switchgear and panelboard installations, it is commonly used in applications requiring high interrupt ratings and reliable circuit isolation.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1135\" data-end=\"1816\"\u003e\n\u003cli data-start=\"1135\" data-end=\"1222\"\u003e100 Amp Rating: Supports medium-load circuits in industrial and commercial systems.\u003c\/li\u003e\n\u003cli data-start=\"1223\" data-end=\"1312\"\u003eHigh Voltage Capability: Operates up to 690 VAC for expanded application flexibility.\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1394\"\u003e3-Pole Configuration: Provides protection for three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1488\"\u003eThermal-Magnetic Trip Unit: Combines overload and instantaneous short-circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"1489\" data-end=\"1570\"\u003eHigh Interrupt Rating: Rated up to 36 kA for safe fault current interruption.\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1640\"\u003eInsulated Molded Case: Enhances durability and electrical safety.\u003c\/li\u003e\n\u003cli data-start=\"1641\" data-end=\"1734\"\u003eIndustrial Compatibility: Suitable for switchgear, panelboards, and distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1816\"\u003eCompact Design: Optimized for space-efficient installation in control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1818\" data-end=\"1961\"\u003eThe FDS36TD100GD delivers the reliability and precision required for high-capacity circuit protection in industrial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744415488,"sku":"FDS36TD100GD","price":321.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_7ff8bacd-e410-4135-8c2f-e75378c4d262.webp?v=1785531846"},{"product_id":"general-electric-tqdl32125-125a-3-pole-molded-case-circuit-breaker-240vac-q-line","title":"General Electric TQDL32125 125A 3-Pole Molded Case Circuit Breaker 240VAC Q-Line","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"390\"\u003eThe General Electric TQDL32125 is a molded case circuit breaker designed to provide reliable overcurrent protection in commercial and industrial electrical systems. Rated at 125 amps and 240 volts AC, it ensures safe interruption of fault currents in three-phase applications. This breaker is engineered for dependable performance in panelboard and distribution systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTQDL32125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial and industrial distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003eTQDL32125\u003c\/h4\u003e\n\u003cp data-start=\"423\" data-end=\"1011\"\u003eThe TQDL32125 is part of General Electric’s Q-Line series of circuit breakers, known for compact design and consistent protection characteristics. It features a durable molded case construction that supports long-term operation under electrical and thermal stress conditions. The breaker utilizes a thermal-magnetic trip mechanism, combining inverse-time overload protection with instantaneous short-circuit response. Designed for compatibility with GE panelboards and load centers, it is commonly used in commercial distribution systems requiring stable and efficient circuit protection.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1039\" data-end=\"1651\"\u003e\n\u003cli data-start=\"1039\" data-end=\"1117\"\u003e125 Amp Rating: Suitable for medium-load electrical distribution circuits.\u003c\/li\u003e\n\u003cli data-start=\"1118\" data-end=\"1200\"\u003e240 VAC Operation: Designed for low-voltage commercial and industrial systems.\u003c\/li\u003e\n\u003cli data-start=\"1201\" data-end=\"1280\"\u003eThermal-Magnetic Trip: Provides both overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"1281\" data-end=\"1347\"\u003e3-Pole Configuration: Supports three-phase circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"1348\" data-end=\"1433\"\u003eQ-Line Series Design: Ensures compatibility with GE panelboards and load centers.\u003c\/li\u003e\n\u003cli data-start=\"1434\" data-end=\"1508\"\u003eMolded Case Construction: Offers durability and electrical insulation.\u003c\/li\u003e\n\u003cli data-start=\"1509\" data-end=\"1589\"\u003eReliable Fault Interruption: Protects circuits from damaging current surges.\u003c\/li\u003e\n\u003cli data-start=\"1590\" data-end=\"1651\"\u003eCompact Form Factor: Allows efficient use of panel space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1653\" data-end=\"1800\"\u003eThe TQDL32125 delivers the reliability and precision required for circuit protection in commercial and light industrial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744481024,"sku":"TQDL32125","price":1833.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_592dcf89-a4d8-4b95-8be0-42e9dd026014.webp?v=1785531848"},{"product_id":"general-electric-tfj236150wl-150a-3-pole-molded-case-circuit-breaker-600v-f225-line","title":"General Electric TFJ236150WL 150A 3-Pole Molded Case Circuit Breaker 600V F225 Line","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"417\" data-start=\"20\"\u003eThe General Electric TFJ236150WL is a molded case circuit breaker designed for dependable protection in industrial and commercial power distribution systems. Rated at 150 amps and 600 volts, it provides effective interruption of overload and short-circuit conditions in three-phase applications. This breaker incorporates a thermal-magnetic trip unit to ensure consistent and reliable performance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9251%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eTFJ236150WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eTFJ (F225 Line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003e22 kA @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eThermal-Magnetic (Long Time \u0026amp; Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003ePanel \/ Switchgear Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3608%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.2947%;\"\u003e9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TFJ236150WL\u003c\/h4\u003e\n\u003cp data-end=\"1002\" data-start=\"450\"\u003eThe TFJ236150WL is part of General Electric’s F225 Line within the TFJ series of molded case circuit breakers. It is engineered with a robust frame design to support medium-to-high current applications in panelboards and switchgear systems. The breaker utilizes thermal-magnetic protection technology, combining long-time and instantaneous trip functions for accurate fault response. Designed for compatibility with GE distribution equipment, it is widely used in commercial and industrial installations requiring stable and durable circuit protection.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1679\" data-start=\"1030\"\u003e\n\u003cli data-end=\"1117\" data-start=\"1030\"\u003e150 Amp Rating: Supports medium-load circuits in industrial and commercial systems.\u003c\/li\u003e\n\u003cli data-end=\"1204\" data-start=\"1118\"\u003e600 Volt Capacity: Suitable for high-voltage electrical distribution environments.\u003c\/li\u003e\n\u003cli data-end=\"1293\" data-start=\"1205\"\u003eThermal-Magnetic Trip Unit: Provides reliable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-end=\"1361\" data-start=\"1294\"\u003e3-Pole Design: Enables protection of three-phase power systems.\u003c\/li\u003e\n\u003cli data-end=\"1431\" data-start=\"1362\"\u003eHigh Interrupt Rating: Handles fault currents up to 22kA at 480V.\u003c\/li\u003e\n\u003cli data-end=\"1510\" data-start=\"1432\"\u003eF225 Line Frame: Built for durability and compatibility within GE systems.\u003c\/li\u003e\n\u003cli data-end=\"1588\" data-start=\"1511\"\u003eFeed-Thru Connection: Simplifies installation and electrical integration.\u003c\/li\u003e\n\u003cli data-end=\"1679\" data-start=\"1589\"\u003eIndustrial Construction: Designed for long-term performance in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1824\" data-start=\"1681\"\u003eThe TFJ236150WL delivers the reliability and precision required for circuit protection in industrial and commercial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744546560,"sku":"TFJ236150WL","price":1825.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-16_23.27.21.png?v=1785531849"},{"product_id":"general-electric-ted136015-15a-3-pole-molded-case-circuit-breaker-600v-bolt-on-ted-series","title":"General Electric TED136015 15A 3-Pole Molded Case Circuit Breaker 600V Bolt-On TED Series","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"405\"\u003eThe General Electric TED136015 is a molded case circuit breaker designed to provide reliable protection for three-phase electrical systems in industrial and commercial applications. Rated at 15 amps and 600 volts, it ensures effective interruption of overloads and short circuits. This breaker utilizes thermal-magnetic trip technology for consistent and dependable circuit protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9251%; height: 372.413px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eTED136015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eTED (E150 Line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003e18 kA @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eThermal-Magnetic (Long Time \u0026amp; Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eLoad Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 26.6593%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.7007%; height: 19.6007px;\"\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TED136015\u003c\/h4\u003e\n\u003cp data-start=\"438\" data-end=\"965\"\u003eThe TED136015 is part of General Electric’s E150 Line within the TED series of molded case circuit breakers. It features a compact and durable design with bolt-on mounting, allowing secure installation in panelboards and switchgear systems. Equipped with a thermal-magnetic trip unit, it provides both long-time and instantaneous protection functions for enhanced system safety. This breaker is commonly used in commercial and industrial environments where dependable low-current protection in three-phase circuits is required.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"993\" data-end=\"1606\"\u003e\n\u003cli data-start=\"993\" data-end=\"1072\"\u003e15 Amp Rating: Designed for low-current protection in three-phase circuits.\u003c\/li\u003e\n\u003cli data-start=\"1073\" data-end=\"1143\"\u003e600 Volt Capacity: Suitable for high-voltage distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1227\"\u003eThermal-Magnetic Trip: Provides combined overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"1228\" data-end=\"1303\"\u003e3-Pole Configuration: Supports balanced three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-start=\"1304\" data-end=\"1380\"\u003e18kA Interrupt Rating: Safely interrupts fault currents at 480V systems.\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1457\"\u003eBolt-On Mounting: Ensures secure and stable installation in panelboards.\u003c\/li\u003e\n\u003cli data-start=\"1458\" data-end=\"1527\"\u003eLoad Lug Terminals: Simplifies wiring and electrical connections.\u003c\/li\u003e\n\u003cli data-start=\"1528\" data-end=\"1606\"\u003eUL Listed Certification: Meets recognized safety and compliance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1608\" data-end=\"1749\"\u003eThe TED136015 delivers the reliability and precision required for circuit protection in industrial and commercial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744644864,"sku":"TED136015","price":313.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/general-electric-ge-ted136015-3-pole-15-amp-600v-circuit-breaker-iso-600.jpg?v=1785531852"},{"product_id":"general-electric-amc3km-1200a-3-pole-circuit-breaker-module-for-spectra-series-panelboards","title":"General Electric AMC3KM 1200A 3-Pole Circuit Breaker Module for Spectra Series Panelboards","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"421\"\u003eThe General Electric AMC3KM is a 3-pole circuit breaker module designed for use in Spectra Series panelboards in industrial and commercial power distribution systems. Rated for up to 1200 amps and 600 VAC, it provides a reliable connection interface for high-capacity breaker installations. This module ensures secure mounting and efficient current distribution in GE-compatible panelboard assemblies.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAMC3KM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreaker Module \/ Mounting Mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Branch \/ Main Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panelboards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra Series APN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breaker Frames\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTKM, THKM, TKMA, THKMA, SKHA, SKLA, SKPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial and Commercial Power Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About AMC3KM\u003c\/h4\u003e\n\u003cp data-start=\"454\" data-end=\"1006\"\u003eThe AMC3KM is a circuit breaker module from General Electric’s Spectra Series, engineered for use with APN plug-in style panelboards. It is constructed with durable copper components to support high-current applications and ensure efficient electrical conductivity. Designed for compatibility with breaker frames such as TKM, THKM, TKMA, THKMA, SKHA, SKLA, and SKPA, it enables flexible system configuration. This module is typically used in industrial and commercial switchboard systems where high-capacity branch or main breaker mounting is required.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1034\" data-end=\"1725\"\u003e\n\u003cli data-start=\"1034\" data-end=\"1124\"\u003eHigh Current Capacity: Supports up to 1200A for heavy-duty power distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1125\" data-end=\"1210\"\u003e600 VAC Rating: Suitable for high-voltage industrial and commercial applications.\u003c\/li\u003e\n\u003cli data-start=\"1211\" data-end=\"1281\"\u003e3-Pole Configuration: Designed for three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-start=\"1282\" data-end=\"1365\"\u003eSpectra Series Compatibility: Works with GE\/ABB Spectra Series APN panelboards.\u003c\/li\u003e\n\u003cli data-start=\"1366\" data-end=\"1461\"\u003eMulti-Frame Support: Compatible with TKM, THKM, TKMA, THKMA, SKHA, SKLA, and SKPA breakers.\u003c\/li\u003e\n\u003cli data-start=\"1462\" data-end=\"1544\"\u003eCopper Construction: Provides excellent conductivity and long-term durability.\u003c\/li\u003e\n\u003cli data-start=\"1545\" data-end=\"1637\"\u003ePlug-In Module Design: Allows efficient installation and replacement within panelboards.\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1725\"\u003eBranch\/Main Mounting: Supports both branch circuit and main breaker configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1727\" data-end=\"1877\"\u003eThe AMC3KM delivers the reliability and precision required for high-capacity breaker mounting and distribution in industrial power panelboard systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104744808704,"sku":"AMC3KM","price":1983.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-16_18.33.57.png?v=1785531858"},{"product_id":"general-electric-sghh36at0400-400a-3-pole-molded-case-circuit-breaker-600vac-spectra-series","title":"General Electric SGHH36AT0400 400A 3-Pole Molded Case Circuit Breaker 600VAC Spectra Series","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"410\"\u003eThe General Electric SGHH36AT0400 is a high-capacity molded case circuit breaker designed for industrial and commercial power distribution systems. Rated at 400 amps and 600 VAC, it provides reliable protection against overloads and short circuits in three-phase applications. This breaker incorporates solid-state trip technology for accurate and consistent circuit protection performance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSGHH36AT0400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra Series (SGHA Frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 kA @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-State RMS Sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong Time, Short Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel \/ Switchboard Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SGHH36AT0400\u003c\/h4\u003e\n\u003cp data-start=\"443\" data-end=\"1038\"\u003eThe SGHH36AT0400 is part of General Electric’s Spectra Series SGHA family of molded case circuit breakers, engineered for heavy-duty electrical distribution environments. It features a robust frame construction with bolt-on mounting, ensuring secure installation in switchboards and panelboards. Equipped with a solid-state RMS sensing trip system, it delivers precise long-time, short-time, and instantaneous protection functions. This breaker is widely used in industrial facilities and commercial infrastructures where dependable high-current protection and system coordination are essential.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1066\" data-end=\"1818\"\u003e\n\u003cli data-start=\"1066\" data-end=\"1174\"\u003e400 Amp Current Rating: Supports high-load electrical systems in industrial and commercial environments.\u003c\/li\u003e\n\u003cli data-start=\"1175\" data-end=\"1271\"\u003eSolid-State Trip Unit: Provides accurate RMS sensing for consistent and reliable protection.\u003c\/li\u003e\n\u003cli data-start=\"1272\" data-end=\"1363\"\u003eThree-Pole Configuration: Designed for balanced three-phase power distribution systems.\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1459\"\u003e600 VAC Voltage Rating: Suitable for high-voltage applications in heavy-duty installations.\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1546\"\u003e35kA Interrupting Capacity: Safely interrupts high fault currents at 480V systems.\u003c\/li\u003e\n\u003cli data-start=\"1547\" data-end=\"1638\"\u003eBolt-On Mounting Design: Ensures stable and secure installation in distribution panels.\u003c\/li\u003e\n\u003cli data-start=\"1639\" data-end=\"1738\"\u003eMultiple Trip Functions: Includes long-time, short-time, and instantaneous protection settings.\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1818\"\u003eUL Listed Certification: Meets recognized safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1820\" data-end=\"1978\"\u003eThe SGHH36AT0400 delivers the reliability and precision required for high-capacity circuit protection in industrial and commercial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104745005312,"sku":"SGHH36AT0400","price":3085.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-15_21.30.18.png?v=1785531862"},{"product_id":"general-electric-thql1115paf2-15a-1-pole-afci-circuit-breaker-q-line-plug-on-neutral","title":"General Electric THQL1115PAF2 15A 1-Pole AFCI Circuit Breaker Q-Line Plug-On Neutral","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"431\"\u003eThe General Electric THQL1115PAF2 is a Q-Line combination arc fault circuit breaker designed to provide advanced protection in residential and light commercial electrical systems. This 1-pole, 15 amp breaker operates at 120\/240V AC and integrates both thermal-magnetic overload protection and arc fault detection. It is engineered for safe, code-compliant installation in load centers requiring AFCI protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHQL1115PAF2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ-Line (THQL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination Arc Fault Circuit Breaker (AFCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic (Long Time \u0026amp; Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidential and Light Commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THQL1115PAF2\u003c\/h4\u003e\n\u003cp data-start=\"464\" data-end=\"1037\"\u003eThe THQL1115PAF2 is part of General Electric’s Q-Line series of plug-on circuit breakers, known for their reliability and ease of installation. It features a combination Arc Fault Circuit Interrupter (AFCI) design that detects hazardous arc conditions while maintaining standard overload and short-circuit protection. Built with a plug-on neutral connection, it simplifies wiring and reduces installation time in compatible GE load centers. This breaker is widely used in residential and light commercial panelboards to meet NEC requirements for enhanced electrical safety.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1065\" data-end=\"1766\"\u003e\n\u003cli data-start=\"1065\" data-end=\"1162\"\u003eCombination AFCI Protection: Detects both parallel and series arc faults to reduce fire risk.\u003c\/li\u003e\n\u003cli data-start=\"1163\" data-end=\"1251\"\u003eThermal Magnetic Trip Unit: Provides reliable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-start=\"1252\" data-end=\"1338\"\u003ePlug-On Neutral Design: Enables faster installation with fewer wiring connections.\u003c\/li\u003e\n\u003cli data-start=\"1339\" data-end=\"1429\"\u003e15 Amp Rating: Suitable for standard branch circuit protection in residential systems.\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1517\"\u003e10kA Interrupt Rating: Handles high fault currents safely in typical installations.\u003c\/li\u003e\n\u003cli data-start=\"1518\" data-end=\"1605\"\u003eQ-Line Compatibility: Designed for use with GE Q-Line load centers and panelboards.\u003c\/li\u003e\n\u003cli data-start=\"1606\" data-end=\"1682\"\u003eUL Listed Certification: Meets industry safety and compliance standards.\u003c\/li\u003e\n\u003cli data-start=\"1683\" data-end=\"1766\"\u003eCompact 1-Pole Design: Saves space while delivering full protection capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1768\" data-end=\"1940\"\u003eThe THQL1115PAF2 delivers the reliability and precision required for safe and code-compliant electrical circuit protection in residential and light commercial applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104745070848,"sku":"THQL1115PAF2","price":380.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-04-15_21.17.35.png?v=1785531864"},{"product_id":"general-electric-fdn36td160gd-3-pole-160a-molded-case-circuit-breaker-50ka","title":"General Electric FDN36TD160GD 3-Pole 160A Molded Case Circuit Breaker 50kA","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"484\"\u003eThe General Electric FDN36TD160GD is a molded case circuit breaker designed to provide overcurrent and short-circuit protection in industrial electrical distribution systems. It features a 3-pole configuration with a 160A rating and high interrupting capacity, making it suitable for demanding applications requiring reliable fault protection. This breaker is commonly used in panelboards and switchgear assemblies to ensure safe and controlled power distribution.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFDN36TD160GD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFD Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvercurrent and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded case industrial design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE panelboards and switchgear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00 lb (1.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FDN36TD160GD\u003c\/h4\u003e\n\u003cp data-start=\"517\" data-end=\"1112\"\u003eThe FDN36TD160GD is part of General Electric’s FD series of molded case circuit breakers, engineered for industrial and commercial power systems. It incorporates a thermal magnetic trip mechanism that delivers both long-time overload protection and instantaneous short-circuit interruption. The unit is built with a compact molded case housing and is designed for integration into panelboards, switchgear, and distribution assemblies. Its construction supports high interrupting capacity performance, making it suitable for applications where system reliability and fault tolerance are critical.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1140\" data-end=\"1803\"\u003e\n\u003cli data-start=\"1140\" data-end=\"1224\"\u003e3-Pole Configuration: Designed for protection of three-phase electrical circuits\u003c\/li\u003e\n\u003cli data-start=\"1225\" data-end=\"1302\"\u003e160 Amp Rating: Supports circuits requiring up to 160A continuous current\u003c\/li\u003e\n\u003cli data-start=\"1303\" data-end=\"1391\"\u003eThermal Magnetic Trip: Provides combined overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli data-start=\"1392\" data-end=\"1472\"\u003eHigh Interrupting Capacity: Rated up to 50kA for reliable fault interruption\u003c\/li\u003e\n\u003cli data-start=\"1473\" data-end=\"1562\"\u003eFD Series Design: Built for use in GE industrial panelboards and distribution systems\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1651\"\u003eMolded Case Construction: Durable enclosure for electrical and mechanical protection\u003c\/li\u003e\n\u003cli data-start=\"1652\" data-end=\"1741\"\u003ePanel Mount Installation: Suitable for integration into switchgear and control panels\u003c\/li\u003e\n\u003cli data-start=\"1742\" data-end=\"1803\"\u003eCompact Form Factor: Enables efficient use of panel space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1805\" data-end=\"1958\"\u003eThe FDN36TD160GD delivers the reliability and precision required for overcurrent protection in industrial and commercial electrical distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104748544256,"sku":"FDN36TD160GD","price":730.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_6d25ea48-edde-42db-9c16-fa2420305677.webp?v=1785531953"},{"product_id":"general-electric-thed136015wl-3-pole-15a-molded-case-circuit-breaker-600v","title":"General Electric THED136015WL 3-Pole 15A Molded Case Circuit Breaker 600V","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"451\"\u003eThe General Electric THED136015WL is a molded case circuit breaker designed for overcurrent protection in high-voltage three-phase electrical systems. It features a 3-pole configuration rated at 15A and supports operation up to 600V, making it suitable for industrial distribution and control panel applications. This breaker provides dependable circuit interruption to protect equipment from overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED136015WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvercurrent and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded case industrial design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE panelboards and switchgear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.80 lb (1.72 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THED136015WL\u003c\/h4\u003e\n\u003cp data-start=\"484\" data-end=\"1111\"\u003eThe THED136015WL is part of General Electric’s E-Line series of molded case circuit breakers, engineered for use in commercial and industrial power distribution systems. It incorporates a thermal magnetic trip mechanism that combines long-time overload protection with instantaneous fault interruption for reliable circuit safety. Designed with a compact frame and durable housing, it integrates into panelboards and switchgear assemblies requiring 3-pole protection. Although discontinued by the manufacturer, it remains compatible with legacy GE installations and is commonly used in maintenance and replacement applications.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1139\" data-end=\"1749\"\u003e\n\u003cli data-start=\"1139\" data-end=\"1220\"\u003e3-Pole Configuration: Provides protection for three-phase electrical circuits\u003c\/li\u003e\n\u003cli data-start=\"1221\" data-end=\"1296\"\u003e15 Amp Rating: Suitable for low-current circuit protection applications\u003c\/li\u003e\n\u003cli data-start=\"1297\" data-end=\"1361\"\u003e600V Operation: Designed for high-voltage industrial systems\u003c\/li\u003e\n\u003cli data-start=\"1362\" data-end=\"1445\"\u003eThermal Magnetic Trip: Combines overload and short-circuit protection functions\u003c\/li\u003e\n\u003cli data-start=\"1446\" data-end=\"1526\"\u003eMolded Case Design: Durable enclosure for industrial electrical environments\u003c\/li\u003e\n\u003cli data-start=\"1527\" data-end=\"1605\"\u003ePanel Integration: Compatible with GE panelboards and distribution systems\u003c\/li\u003e\n\u003cli data-start=\"1606\" data-end=\"1681\"\u003eDiscontinued Model: Available for replacement and legacy system support\u003c\/li\u003e\n\u003cli data-start=\"1682\" data-end=\"1749\"\u003eCompact Construction: Designed for efficient use of panel space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1751\" data-end=\"1901\"\u003eThe THED136015WL delivers the reliability and precision required for protecting electrical circuits in industrial and commercial distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104748642560,"sku":"THED136015WL","price":939.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/general-electric-ge-thed136015wl-3-pole-15-amp-600v-circuit-breaker-iso-600.jpg?v=1785531954"},{"product_id":"general-electric-ssf16b216-circuit-breaker-frame-stationary-panel-mount-unit","title":"General Electric SSF16B216 Circuit Breaker Frame Stationary Panel Mount Unit","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"435\"\u003eThe General Electric SSF16B216 is a stationary molded case circuit breaker frame designed for use in industrial and commercial electrical distribution systems. It serves as a base unit that requires a separately installed trip unit to provide overcurrent protection functionality. This frame is engineered for panel-mounted applications where high-capacity circuit protection and modular configuration are required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSSF16B216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame only (trip unit sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStationary \/ Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE trip units (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitchgear \/ Panelboard integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty industrial frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase unit for circuit breaker assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eServiceability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReplaceable trip unit design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 lb (27.22 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SSF16B216\u003c\/h4\u003e\n\u003cp data-start=\"468\" data-end=\"1066\"\u003eThe SSF16B216 is a circuit breaker frame from General Electric intended for use within larger power distribution assemblies. It is constructed as a stationary unit and is designed to accept a compatible trip unit, allowing customization of protection characteristics based on application requirements. The frame supports integration into switchgear and panelboard systems, offering flexibility in configuring protection schemes for industrial environments. Its heavy-duty construction and modular design make it suitable for high-current systems where adaptability and serviceability are essential.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1094\" data-end=\"1711\"\u003e\n\u003cli data-start=\"1094\" data-end=\"1191\"\u003eFrame-Only Design: Supplied without a trip unit, allowing customized protection configuration\u003c\/li\u003e\n\u003cli data-start=\"1192\" data-end=\"1288\"\u003eStationary Mounting: Designed for fixed installation within electrical panels and switchgear\u003c\/li\u003e\n\u003cli data-start=\"1289\" data-end=\"1375\"\u003eModular Compatibility: Accepts compatible GE trip units for flexible system design\u003c\/li\u003e\n\u003cli data-start=\"1376\" data-end=\"1473\"\u003eHigh-Capacity Construction: Built for use in heavy-duty industrial power distribution systems\u003c\/li\u003e\n\u003cli data-start=\"1474\" data-end=\"1548\"\u003ePanel Integration: Suitable for panelboard and switchgear applications\u003c\/li\u003e\n\u003cli data-start=\"1549\" data-end=\"1629\"\u003eServiceable Design: Enables easier maintenance and replacement of trip units\u003c\/li\u003e\n\u003cli data-start=\"1630\" data-end=\"1711\"\u003eDurable Build: Engineered for long-term reliability in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1713\" data-end=\"1860\"\u003eThe SSF16B216 delivers the reliability and precision required for configurable circuit protection in high-capacity electrical distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104748740864,"sku":"SSF16B216","price":6760.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/GE_STD_Power_Break_001__49688.1453917108.1280.1280.jpg?v=1785531961"},{"product_id":"general-electric-tqd32125-3-pole-125a-molded-case-circuit-breaker-240v-q-line","title":"General Electric TQD32125 3-Pole 125A Molded Case Circuit Breaker 240V Q-Line","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"476\"\u003eThe General Electric TQD32125 is a Q-Line molded case circuit breaker designed to provide reliable overcurrent protection in three-phase electrical distribution systems. It is a 3-pole, 125A breaker rated for 240V applications, utilizing thermal magnetic trip technology for both long-time and instantaneous protection. This breaker is commonly used in commercial and industrial panels to safeguard circuits and equipment from overloads and short circuits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTQD32125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI (Long-Time and Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine and Load Lug Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.56 x 4.13 x 2.67 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.02 lb (1.82 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TQD32125\u003c\/h4\u003e\n\u003cp data-start=\"509\" data-end=\"1203\"\u003eThe TQD32125 is part of General Electric’s Q-Line series, specifically built as a Type TQD molded case circuit breaker for panelboard and distribution applications. It features a fixed, non-interchangeable thermal magnetic trip unit that combines long-time and instantaneous protection to ensure reliable circuit interruption under fault conditions. Designed with feed-thru connection capability and line\/load side lug terminals, it supports straightforward installation in three-phase electrical systems. Its construction meets CSA standards and is optimized for operation in environments up to 40°C, making it suitable for commercial, industrial, and infrastructure power distribution setups.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1231\" data-end=\"1884\"\u003e\n\u003cli data-start=\"1231\" data-end=\"1312\"\u003e3-Pole Configuration: Provides protection for three-phase electrical circuits\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1394\"\u003e125 Amp Rating: Designed for circuits requiring up to 125A continuous current\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1479\"\u003eThermal Magnetic Trip: Combines long-time and instantaneous protection functions\u003c\/li\u003e\n\u003cli data-start=\"1480\" data-end=\"1556\"\u003e240V Operation: Suitable for low-voltage distribution systems up to 240V\u003c\/li\u003e\n\u003cli data-start=\"1557\" data-end=\"1641\"\u003e10kA Interrupt Rating: Capable of interrupting fault currents up to 10kA at 240V\u003c\/li\u003e\n\u003cli data-start=\"1642\" data-end=\"1717\"\u003eFeed-Thru Design: Allows flexible wiring with line and load connections\u003c\/li\u003e\n\u003cli data-start=\"1718\" data-end=\"1797\"\u003eQ-Line Compatibility: Designed for use in GE Q-Line panelboards and systems\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1884\"\u003eLug Terminal Connections: Includes line and load side lugs for secure installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1886\" data-end=\"2035\"\u003eThe TQD32125 delivers the reliability and precision required for overcurrent protection in commercial and industrial electrical distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49104749003008,"sku":"TQD32125","price":388.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/tqd32125-new-new-1.jpg?v=1785531964"},{"product_id":"sfla24at0250-general-electric-spectra-series-250a-2-pole-molded-case-circuit-breaker","title":"SFLA24AT0250 | General Electric Spectra Series 250A 2-Pole Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"230\" data-end=\"712\"\u003eThe General Electric SFLA24AT0250 is a molded case circuit breaker engineered for high-capacity power distribution and system protection in industrial and commercial environments. This 2-pole, 250 amp breaker utilizes an electronic solid-state trip unit with LSI protection to ensure accurate response to overloads and fault conditions. Designed with a compact, current-limiting Spectra Series construction, the SFLA24AT0250 delivers dependable performance at higher voltage levels.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFLA24AT0250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 VAC \/ 600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Solid State\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLSI – Long-Time, Short-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kA @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.12 in × 3.81 in × 10.12 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003eSFLA24AT0250\u003c\/h4\u003e\n\u003cp data-start=\"744\" data-end=\"1350\"\u003eThe SFLA24AT0250 is a General Electric Spectra Series molded case circuit breaker built on the SF frame platform for robust electrical protection. It incorporates an RMS electronic solid-state trip unit that provides long-time, short-time, and instantaneous protection for enhanced coordination and system reliability. Designed for bolt-on mounting, this breaker supports installation in switchgear and panelboards operating at 480V and 600V systems. Its UL and CSA certifications confirm suitability for regulated industrial applications requiring high interrupt capacity and current-limiting performance.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e250 Amp Current Rating: Supports high-load distribution circuits in demanding environments\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Provides coordinated protection across two conductors\u003c\/li\u003e\n\u003cli\u003eElectronic Solid-State Trip Unit: Delivers precise LSI (long-time, short-time, instantaneous) protection\u003c\/li\u003e\n\u003cli\u003eHigh Interrupt Rating: Rated at 65kA at 480V for superior short-circuit protection\u003c\/li\u003e\n\u003cli\u003eCurrent-Limiting Design: Reduces peak fault energy to protect downstream equipment\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Enables secure installation in panelboards and switchgear\u003c\/li\u003e\n\u003cli\u003eSpectra Series Construction: Compact and durable design for industrial power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SFLA24AT0250 delivers the reliability and precision required for high-capacity industrial power distribution and circuit protection systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105042178304,"sku":"SFLA24AT0250","price":1321.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2026-01-10_20.23.44.png?v=1785538681"},{"product_id":"thed124025-general-electric-25a-2-pole-480v-thermal-magnetic-molded-case-circuit-breaker","title":"THED124025 | General Electric 25A 2-Pole 480V Thermal-Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric THED124025 is a 2-pole molded case circuit breaker designed to provide dependable overcurrent protection in 480-volt systems. With a 25-amp rating and a thermal-magnetic trip unit, it delivers accurate response to overload and fault conditions. This breaker is suited for commercial and industrial distribution equipment requiring a compact, bolt-on protective device with high interrupting capacity.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED124025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE-150 Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHE \/ TED Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time \u0026amp; Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine and Load Side Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489, ANSI C37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About THED124025\u003c\/h4\u003e\n\u003cp\u003eThe THED124025 is part of GE’s E-150 Line series, built on the THE\/TED frame platform for compatibility with a wide range of GE panelboards and switchboards. Its molded case design ensures durability, while the thermal-magnetic trip unit provides long-time and instantaneous protection tailored for demanding electrical environments. The breaker supports bolt-on mounting, making it suitable for installations where secure mechanical fastening is required. Its 25kA interrupting rating at 480 volts allows it to perform reliably in high-fault industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e25A Thermal-Magnetic Trip: Ensures precise overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Protects two conductors in single-phase 480V systems.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Rating: Rated at 25kA at 480V for robust fault-handling capability.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Provides secure mechanical installation in compatible GE distribution panels.\u003c\/li\u003e\n\u003cli\u003eE-150 Line \/ THE Frame Construction: Ensures compatibility with GE’s industrial circuit protection platforms.\u003c\/li\u003e\n\u003cli\u003eUL 489 and ANSI Certified: Meets industry standards for electrical safety and performance.\u003c\/li\u003e\n\u003cli\u003eWide Temperature Operating Range: Suitable for environments from –25°C to 70°C.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Terminal Design: Supports straightforward line and load lug connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THED124025 delivers the reliability and precision required for dependable molded case circuit protection in commercial and industrial power systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105068359936,"sku":"THED124025","price":1027.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-19_15.57.42.png?v=1785539337"},{"product_id":"thqd22200wl-general-electric-200a-2-pole-240v-thermal-magnetic-molded-case-circuit-breaker","title":"THQD22200WL | General Electric 200A 2-Pole 240V Thermal-Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric THQD22200WL is a 2-pole molded case circuit breaker designed to provide dependable overcurrent protection in 240-volt systems. With a 200-amp rating and thermal-magnetic trip technology, it ensures accurate response to overloads and faults. This breaker is suitable for residential, commercial, and light-industrial electrical distribution applications requiring high interrupting performance.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 392.014px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eTHQD22200WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eTHQD \/ Q-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003e22kA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eLong-Time \u0026amp; Instantaneous (LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003e6.56\" × 2.75\" × 2.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 40.3179%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5434%; height: 19.6007px;\"\u003e2.76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eTHQD22200WL\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe THQD22200WL is part of GE’s Q-Line THQD series, engineered for compatibility with panelboards and switchboards that accept THQD-frame breakers. It features a molded case housing and a non-interchangeable thermal-magnetic trip unit that provides long-time and instantaneous functions. Designed for feed-thru installations, it supports single-phase, 240-volt systems that require reliable circuit protection. Its UL listing and compact dimensions make it suitable for both new installations and replacement of existing Q-Line components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200A Thermal-Magnetic Trip: Provides accurate overcurrent protection with long-time and instantaneous response.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Supports protection of two conductors in single-phase 240V circuits.\u003c\/li\u003e\n\u003cli\u003e22 kA Interrupt Rating: Handles high fault currents for enhanced system safety.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Connection: Simplifies installation into compatible GE distribution equipment.\u003c\/li\u003e\n\u003cli\u003eTHQD\/Q-Line Series Compatibility: Ensures fit and performance consistency with GE THQD panelboard systems.\u003c\/li\u003e\n\u003cli\u003eUL Listed Construction: Meets established safety and performance standards for electrical protection devices.\u003c\/li\u003e\n\u003cli\u003eDurable Molded Case: Provides mechanical strength and stability in demanding environments.\u003c\/li\u003e\n\u003cli\u003eCompact Form Factor: Allows installation where panel space is limited.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THQD22200WL delivers the reliability and precision required for safe and stable overcurrent protection in power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105068491008,"sku":"THQD22200WL","price":2306.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/CB-THQD22200WL-1.jpg?v=1785539342"},{"product_id":"thqd22200-general-electric-200a-2-pole-240v-thermal-magnetic-molded-case-circuit-breaker","title":"THQD22200 | General Electric 200A 2-Pole 240V Thermal-Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric THQD22200 is a 2-pole molded case circuit breaker engineered to provide reliable overcurrent protection in 240-volt systems. This breaker uses a thermal-magnetic trip mechanism to ensure accurate response to overloads and short-circuit conditions. Its 200-amp rating makes it suitable for demanding residential, commercial, and light industrial applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHQD22200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHQD \/ Q-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22kA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Instantaneous (LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHQD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.56\" × 2.75\" × 2.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THQD22200\u003c\/h4\u003e\n\u003cp\u003eThe THQD22200 is part of GE’s Q-Line THQD series, built for dependable performance in panelboard and switchboard installations. It features a molded case construction with a non-interchangeable thermal-magnetic trip unit designed for long-time and instantaneous functions. This model is compatible with feed-thru installations in single-phase 240V systems, supporting standard electrical distribution layouts. Its compact footprint and UL\/CSA compliance make it suitable for both new assemblies and replacement use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200A Thermal-Magnetic Protection: Provides combined long-time overload and instantaneous short-circuit response.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Supports protection of two conductors in 240V single-phase systems.\u003c\/li\u003e\n\u003cli\u003e22 kA Interrupt Rating: Handles high fault currents for enhanced circuit safety.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Connection: Allows straightforward installation into compatible GE panelboards.\u003c\/li\u003e\n\u003cli\u003eQ-Line THQD Series Design: Ensures dimensional compatibility with GE THQD frame equipment.\u003c\/li\u003e\n\u003cli\u003eNon-Interchangeable Trip Unit: Factory-calibrated trip settings for consistent performance.\u003c\/li\u003e\n\u003cli\u003eMolded Case Housing: Durable enclosure designed to withstand mechanical and thermal stress.\u003c\/li\u003e\n\u003cli\u003eCompact Dimensions: Fits in space-limited electrical distribution environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THQD22200 delivers the reliability and precision required for robust overcurrent protection in residential, commercial, and light-industrial systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105068753152,"sku":"THQD22200","price":1674.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/CB-THQD22200WL-1_cc8b26cc-c642-4c7b-8732-dd2342896710.jpg?v=1785539349"},{"product_id":"tmqd22125-general-electric-125a-2-pole-240v-bolt-on-molded-case-circuit-breaker","title":"TMQD22125 | General Electric 125A 2-Pole 240V Bolt-On Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric TMQD22125 is a 2-pole molded case circuit breaker designed to provide dependable protection for 240VAC electrical distribution systems. This breaker offers stable thermal-magnetic performance with a 125-amp rating suitable for both branch and main applications. The TMQD22125 is built for installations requiring high interrupting capacity and secure bolt-on connectivity.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD22125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100kAIC at 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad-Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Ibs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TMQD22125\u003c\/h4\u003e\n\u003cp\u003eThe TMQD22125 is part of GE’s TMQD series, engineered for high-demand commercial and light-industrial distribution panels. It features a durable molded case design and bolt-on mounting for secure installation and consistent contact integrity. This breaker supports long-time and instantaneous trip functions, making it suitable for overcurrent and short-circuit protection in single-phase systems. Its high 100kAIC interrupting rating at 240V provides expanded compatibility with environments requiring elevated fault-current tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e125A Current Rating: Supports medium-capacity circuits in commercial and industrial systems.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated at 100kAIC at 240V for demanding fault-current conditions.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Protection: Provides long-time and instantaneous trip functions for accurate overload response.\u003c\/li\u003e\n\u003cli\u003eDurable Molded Case: Ensures reliable operation and prolonged mechanical life.\u003c\/li\u003e\n\u003cli\u003eBolt-On Connection: Offers secure panel integration and stable electrical contact.\u003c\/li\u003e\n\u003cli\u003eLoad-Side Lug Terminal: Supports straightforward and dependable conductor termination.\u003c\/li\u003e\n\u003cli\u003eTMQD Frame Design: Matches GE distribution equipment for consistent performance and compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TMQD22125 delivers the reliability and precision required for safe and stable power distribution in 240VAC systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105069506816,"sku":"TMQD22125","price":668.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TMQD22125_5619__97672.1633888585.jpg?v=1785539371"},{"product_id":"tqd22150wl-general-electric-150a-2-pole-thermal-magnetic-molded-case-circuit-breaker","title":"TQD22150WL | General Electric 150A 2-Pole Thermal-Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric TQD22150WL is a 2-pole molded case circuit breaker engineered to provide dependable thermal-magnetic protection in residential, commercial, and light industrial installations. With a 150-amp rating and support for 120\/240 VAC systems, it ensures stable circuit interruption under both overload and fault conditions. The TQD22150WL is designed for applications requiring reliable performance, straightforward installation, and compatibility with GE Q-Line systems.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTQD22150WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTQD \/ Q-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kAIC @ 277\/480 VAC; 10 kAIC @ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI – Long-Time \u0026amp; Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad-Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 AWG to 300 MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.56 × 2.75 × 2.63 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Molded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.75 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e TQD22150WL\u003c\/h4\u003e\n\u003cp\u003eThe TQD22150WL is part of GE’s TQD series, built with a molded case design that offers high dielectric strength and durable mechanical construction. It is compatible with lighting panels, modular metering equipment, and other systems utilizing feed-thru mounting. This breaker uses LI trip technology, providing long-time overload response along with instantaneous protection for short-circuit events. Its thermal-magnetic trip unit and standardized toggle actuator make it suitable for a wide range of single-phase power distribution applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e150 A Circuit Protection: Provides stable overload and fault handling for single-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip Unit: Combines long-time and instantaneous protection for accurate circuit response.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Configuration: Enables linear wiring with straightforward integration into Q-Line panel systems.\u003c\/li\u003e\n\u003cli\u003eHigh Mechanical Strength Case: Molded housing ensures durability and strong dielectric performance.\u003c\/li\u003e\n\u003cli\u003eWide Wire Compatibility: Supports wire sizes from 4 AWG to 300 MCM for flexible installation conditions.\u003c\/li\u003e\n\u003cli\u003eStandard Interrupt Rating: Rated 14 kAIC at 277\/480 VAC and 10 kAIC at 240 VAC for general power distribution.\u003c\/li\u003e\n\u003cli\u003eToggle Actuator: Provides quick-make, quick-break operation and clear trip indication.\u003c\/li\u003e\n\u003cli\u003eUL and CSA Listed: Complies with recognized safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TQD22150WL delivers the reliability and precision required for molded case circuit protection in commercial and residential power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105069572352,"sku":"TQD22150WL","price":1174.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TQD-2-Pole_1252f37a-4fc6-4dd8-9667-6cf1e2aa8d4a.jpg?v=1785539375"},{"product_id":"thed124100wl-general-electric-100a-2-pole-480v-thermal-magnetic-molded-case-circuit-breaker","title":"THED124100WL | General Electric 100A 2-Pole 480V Thermal-Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric THED124100WL is a 2-pole molded case circuit breaker engineered to provide thermal-magnetic protection for 480 VAC systems. Designed for dependable interruption of overloads and short-circuits, it supports 100-amp applications in commercial and industrial environments. The THED124100WL ensures stable performance with a high interrupting rating suitable for demanding power distribution systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED124100WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE150 Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 VAC \/ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kAIC @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine and Load Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.31 × 4.13 × 4.09 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THED124100WL\u003c\/h4\u003e\n\u003cp\u003eThe THED124100WL is part of GE’s E150 Line, built with a durable molded case design and configured for feed-thru installation. It features a THED-type frame that offers robust electrical endurance and compatibility with GE distribution panels and bolt-on mounting systems. The breaker uses LI trip technology, providing both long-time overload protection and instantaneous short-circuit response. Its construction and terminal layout support secure integration into single-phase circuits requiring reliable 480V protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 A Rating: Supports medium-capacity electrical loads in commercial and industrial systems.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Protection: Ensures accurate overload and short-circuit response under varying electrical conditions.\u003c\/li\u003e\n\u003cli\u003e25 kAIC Interrupt Capacity: Handles higher fault levels common in 480V power distribution networks.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Provides secure mechanical fastening for panelboard and switchboard applications.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Connection: Allows straightforward integration into linear wiring layouts.\u003c\/li\u003e\n\u003cli\u003eLI Trip Functions: Combines long-time and instantaneous action for comprehensive circuit protection.\u003c\/li\u003e\n\u003cli\u003eLine and Load Lugs Included: Ensures quick installation with compatible copper or aluminum conductors.\u003c\/li\u003e\n\u003cli\u003eE150 Line Construction: Offers a rugged molded case frame designed for environments requiring enhanced durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THED124100WL delivers the reliability and precision required for molded case circuit protection in commercial and industrial power systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105069637888,"sku":"THED124100WL","price":1374.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-17_23.10.08.png?v=1785539377"},{"product_id":"tg3223r-general-electric-100-a-fusible-general-duty-safety-switch-nema-3r-240-vac","title":"TG3223R | General Electric 100 A Fusible General-Duty Safety Switch, NEMA 3R, 240 VAC","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe GE TG3223R is a 100 A general-duty fusible safety switch designed for reliable disconnect and overcurrent protection in residential and light commercial installations. Built with a NEMA 3R outdoor-rated enclosure, it provides dependable switching performance for 240 VAC single-phase systems requiring secure isolation and fuse protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Safety \u0026amp; Disconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTG3223R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral-Duty Fusible Safety Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpec-Setter™ TG Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFusible, General Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 VAC, 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Wires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R (Outdoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHandle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHorsepower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 hp (standard fuse), 15 hp (time delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFusible; supports Class H, K, J, R fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA standard; up to 100 kA with Class R kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Range (Cu\/Al)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–1\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\/75°C conductor rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGSA Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, cUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.05 in H × 9.32 in W × 5.04 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.0 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TG3223R\u003c\/h4\u003e\n\u003cp\u003eThe TG3223R belongs to GE’s Spec-Setter™ TG Series, a line of general-duty safety switches engineered for straightforward installation and long-term serviceability. This model supports two-pole, three-wire configurations and accommodates Class H, K, J, or R fuses depending on application needs. Its quick-make, quick-break mechanism ensures consistent switching action, while the steel enclosure and cover interlock enhance safety during operation. Designed to meet UL and cUL requirements, the switch is suitable for service entrance use when installed according to NEC guidelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 A Fusible Disconnect: Provides reliable overcurrent protection for single-phase 240 VAC circuits.\u003c\/li\u003e\n\u003cli\u003eQuick-Make\/Quick-Break Mechanism: Ensures positive switching action with clear ON\/OFF indication.\u003c\/li\u003e\n\u003cli\u003eNEMA 3R Enclosure: Outdoor-rated steel housing designed for weather-resistant surface mounting.\u003c\/li\u003e\n\u003cli\u003eSupport for Multiple Fuse Classes: Compatible with H, K, J, and R fuses to match application demands.\u003c\/li\u003e\n\u003cli\u003eIntegrated Cover Interlock: Prevents access when the switch is in the ON position for added operator safety.\u003c\/li\u003e\n\u003cli\u003eVisible Blade Contacts: Allows quick confirmation of switch status during maintenance.\u003c\/li\u003e\n\u003cli\u003eHigh SCCR Capability: Standard 10 kA rating, up to 100 kA when paired with Class R fuse kits.\u003c\/li\u003e\n\u003cli\u003eSelf-Leveling Mounting System: Simplifies installation and improves alignment on uneven surfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TG3223R delivers the reliability and precision required for safe electrical isolation and overcurrent protection in general-duty applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105075273984,"sku":"TG3223R","price":407.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/GE_TG3223R.jpg?v=1785539506"},{"product_id":"srpe60a45-ge-spectra-45a-rating-plug-for-se150-circuit-breakers-600-vac","title":"SRPE60A45 | GE Spectra 45A Rating Plug for SE150 Circuit Breakers, 600 VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe General Electric SRPE60A45 is a 45-amp rating plug accessory designed for GE Spectra Series circuit breakers. It establishes the breaker’s trip rating for proper current protection in industrial, commercial, and residential electrical systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 345.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eSRPE60A45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eCircuit Breaker Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eRating plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eSpectra Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003e480\/600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003ePoles Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003e3-pole breaker frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Frames\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eSE150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eSets long-time trip rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eSuitable for 60-amp sensor assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003ePlug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 19.5938px;\"\u003eElectrical panel protection and calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.5938px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 21.5938px;\"\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 21.5938px;\"\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 32.282%; height: 10px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.4054%; height: 10px;\"\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eSRPE60A45\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SRPE60A45 rating plug is part of GE’s Spectra Series accessory family, used to set the long-time trip current of compatible breakers. Built for 600 V AC applications, it supports SE150 frame breakers and select legacy Spectra models. As a plug-in accessory, it allows field adjustment and replacement without removing the breaker from service. Since it is discontinued by the manufacturer, this unit is used primarily for maintenance of older electrical panels requiring precise trip calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e45 Amp Rating Plug: Defines the breaker’s continuous trip rating for accurate circuit protection.\u003c\/li\u003e\n\u003cli\u003eCompatible with Spectra Series: Fits GE Spectra SE150 frame and other approved Spectra models.\u003c\/li\u003e\n\u003cli\u003e600 V AC Rated: Suitable for high-voltage distribution systems up to 480\/600 VAC.\u003c\/li\u003e\n\u003cli\u003ePlug-In Accessory: Installs directly into the breaker without rewiring or removing the device.\u003c\/li\u003e\n\u003cli\u003eSupports 60 Amp Sensor Rating: Calibrates the breaker for a 45-amp operational rating when paired with the correct sensor.\u003c\/li\u003e\n\u003cli\u003eUL Recognized Component: Meets industry compliance requirements for safety and reliability.\u003c\/li\u003e\n\u003cli\u003eSuitable for Multiple Environments: Designed for use in residential, commercial, and industrial distribution panels.\u003c\/li\u003e\n\u003cli\u003eDurable GE Construction: Engineered for long-term performance under demanding electrical loads.\u003c\/li\u003e\n\u003cli\u003eEssential for Breaker Adjustment: Allows field configuration of GE breakers after installation or sensor replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SRPE60A45 delivers the reliability and precision required for maintaining accurate protection levels in GE Spectra Series breaker systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105077207296,"sku":"SRPE60A45","price":326.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_3ae1f52c-162f-459c-ab20-be15cf1830a8.webp?v=1785539561"},{"product_id":"teyl2070b-general-electric-70a-2-pole-480v-thermal-magnetic-bolt-on-molded-case-circuit-breaker","title":"TEYL2070B | General Electric 70A 2-Pole 480V Thermal Magnetic Bolt-On Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TEYL2070B is a 2-pole thermal magnetic molded case circuit breaker designed for reliable overcurrent and short-circuit protection in grounded 480Y\/277 VAC systems. With a current rating of 70 amps and an interrupting capacity of 65kA at 480V, this unit provides dependable performance in commercial and industrial electrical panels. The TEYL2070B features a compact, bolt-on design ideal for panelboard installations where space efficiency and high fault protection are critical.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEYL2070B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEYL \/ Q-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480Y\/277 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65kAIC @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI – Long-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanelboard, Bolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEYL Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#4–2\/0 AWG Cu\/Al\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous Trip Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong Time Trip Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Feed Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed (E11592), CUL Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLighting and Power Distribution Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eTEYL2070B\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe TEYL2070B is part of General Electric’s TEY\/Q-Line bolt-on circuit breaker family, built for precision protection in lighting and distribution panels. It features a thermal magnetic trip mechanism with fixed long-time and instantaneous trip functions, ensuring consistent performance across a wide range of operating conditions. The breaker supports installation in 480Y\/277 VAC systems and can also be used in 120\/240 VAC or 250 VDC applications, offering exceptional flexibility. With quick-make\/quick-break mechanisms, common trip bars, and clear trip indication, the TEYL2070B ensures safe, efficient operation in both new installations and retrofit applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated 65kAIC at 480V for dependable short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Trip: Combines long-time thermal and instantaneous magnetic trip functions for accurate overload and fault response.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Designed for secure and durable installation in GE panelboards.\u003c\/li\u003e\n\u003cli\u003eWide Voltage Range: Supports operation at 120\/240V, 277V, and 480Y\/277V systems.\u003c\/li\u003e\n\u003cli\u003eCompact One-Inch Frame: Space-efficient design ideal for lighting and distribution panels.\u003c\/li\u003e\n\u003cli\u003eQuick-Make\/Quick-Break Mechanism: Provides fast and reliable circuit interruption for enhanced safety.\u003c\/li\u003e\n\u003cli\u003eReverse Feed Capability: Allows installation flexibility in various electrical configurations.\u003c\/li\u003e\n\u003cli\u003eUL and CUL Approved: Compliant with major safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TEYL2070B delivers the reliability and precision required for modern commercial and industrial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082089728,"sku":"TEYL2070B","price":1321.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-09_23.01.07.png?v=1785539703"},{"product_id":"tmqd22150-general-electric-150a-2-pole-240v-thermal-magnetic-molded-case-circuit-breaker","title":"TMQD22150 | General Electric 150A 2-Pole 240V Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric TMQD22150 is a 2-pole thermal magnetic molded case circuit breaker designed for reliable protection of electrical systems operating at 240VAC. With a current rating of 150A and a high interrupting capacity of 100kAIC, it provides dependable overload and short-circuit protection. The TMQD22150 is ideal for commercial and industrial power distribution applications requiring secure and consistent circuit control.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD22150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD Q-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100kAIC @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial and Industrial Power Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.93 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eTMQD22150\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe TMQD22150 is part of General Electric’s TMQD Q-Line series, engineered for robust circuit protection and long-term performance. It features a bolt-on connection type for secure installation in panelboards and switchboards, offering LI (long-time and instantaneous) trip functionality for precise current regulation. This breaker operates efficiently in single-phase systems rated up to 240VAC and is built for use in demanding load environments. Its thermal magnetic mechanism combines temperature-based overload protection with instantaneous magnetic response for fault conditions, ensuring reliable operation under standard 40°C ambient conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated at 100kAIC at 240V for dependable short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Mechanism: Provides both overload (thermal) and short-circuit (magnetic) protection.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Ensures a stable and vibration-resistant installation.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Suitable for single-phase applications requiring double-pole circuit protection.\u003c\/li\u003e\n\u003cli\u003eLI Trip Function: Long-time and instantaneous trip functions for accurate circuit management.\u003c\/li\u003e\n\u003cli\u003eCompact Molded Case: Space-saving design compatible with GE Q-Line systems.\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: Calibrated for operation in 40°C environments.\u003c\/li\u003e\n\u003cli\u003eUL and CSA Certified: Complies with key safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TMQD22150 delivers the reliability and precision required for commercial and industrial circuit protection systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082155264,"sku":"TMQD22150","price":1345.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-09_20.14.08.png?v=1785539706"},{"product_id":"tqd22100wl-general-electric-100a-2-pole-120240v-thermal-magnetic-molded-case-circuit-breaker","title":"TQD22100WL | General Electric 100A 2-Pole 120\/240V Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TQD22100WL is a 2-pole molded case circuit breaker designed for dependable overcurrent and short-circuit protection in residential, commercial, and light industrial installations. With a current rating of 100 amps and a voltage rating of 120\/240 VAC, this breaker ensures safe circuit performance in both main and branch applications. Its feed-thru connection and thermal magnetic trip mechanism provide reliable, long-term operation in demanding electrical systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 470.417px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eTQD22100WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eQ-Line TQD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e100 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e10 kAIC @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eLine \u0026amp; Load Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eBolt-On \/ Feed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e6.56\" x 2.75\" x 2.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eFor Use With\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eLighting Panels, Modular Metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e4 AWG to 300 MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e2.85 lbs (1.29 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TQD22100WL\u003c\/h4\u003e\n\u003cp\u003eThe TQD22100WL is part of General Electric’s Q-Line TQD Series, engineered for high performance and durability across multiple electrical applications. It features a thermal magnetic protection system that combines long-time and instantaneous trip functions for efficient fault interruption. Designed with a feed-thru connection, it supports quick integration into GE panelboards, including AQ Series panels. Built to meet UL and CSA standards, the TQD22100WL is ideal for use in lighting panels, modular metering systems, and branch circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal Magnetic Trip System: Protects against both overload and short-circuit conditions.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Provides full circuit protection for single-phase applications.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Connection: Enables easy installation and secure wiring termination.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Rating: Rated 10 kAIC at 240V for enhanced electrical safety.\u003c\/li\u003e\n\u003cli\u003eNon-Interchangeable Trip Unit: Ensures consistent and factory-calibrated performance.\u003c\/li\u003e\n\u003cli\u003eCompact Dimensions: Saves space in tight panel installations with a slim 2.75\" width.\u003c\/li\u003e\n\u003cli\u003eRugged Molded Case Design: Built for long-lasting operation in harsh environments.\u003c\/li\u003e\n\u003cli\u003eUL and CSA Certified: Tested and approved for safety and reliability compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TQD22100WL delivers the reliability and precision required for effective circuit protection in residential, commercial, and industrial power systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082253568,"sku":"TQD22100WL","price":1359.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TQD22100_7671_clipped_rev_1__46020.1538841925.jpg?v=1785539709"},{"product_id":"tmqd22200-general-electric-200a-2-pole-240v-thermal-magnetic-molded-case-circuit-breaker","title":"TMQD22200 | General Electric 200A 2-Pole 240V Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TMQD22200 is a 2-pole thermal magnetic molded case circuit breaker engineered for dependable electrical protection in commercial and industrial installations. Designed to operate at 240VAC with a 200A current rating, it combines robust performance with high interrupting capacity. The TMQD22200 ensures safe operation and efficient overload and short-circuit protection for distribution systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD22200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD Q-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100kAIC @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMQD Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen (None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.25 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TMQD22200\u003c\/h4\u003e\n\u003cp\u003eThe TMQD22200 is part of General Electric’s TMQD Q-Line series, known for its durable molded case design and reliable protection characteristics. It features a bolt-on connection for secure panel mounting and integrates LI (long-time and instantaneous) trip functions for precise current management. Suitable for use in tenant main applications and lighting panels, the breaker is rated at 100kAIC at 240V, making it ideal for demanding load environments. The device operates within a 40°C ambient temperature and is built to meet UL and CSA standards for electrical safety and performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated at 100kAIC at 240V for robust protection against high fault currents.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Protection: Provides both overload (thermal) and short-circuit (magnetic) protection.\u003c\/li\u003e\n\u003cli\u003eBolt-On Connection: Ensures a secure and stable mounting for panelboard installations.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Supports single-phase applications requiring double-pole circuit protection.\u003c\/li\u003e\n\u003cli\u003eNon-Interchangeable Trip Unit: Factory-calibrated for consistent and reliable performance.\u003c\/li\u003e\n\u003cli\u003eCompact Molded Case: Designed for space-efficient installation without sacrificing strength.\u003c\/li\u003e\n\u003cli\u003eCSA and UL Certified: Meets recognized safety and quality standards.\u003c\/li\u003e\n\u003cli\u003eTemperature Rated at 40°C: Maintains reliable performance under standard ambient conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TMQD22200 delivers the reliability and precision required for commercial and industrial circuit protection applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082286336,"sku":"TMQD22200","price":1741.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TMQD22200-new-1.jpg?v=1785539709"},{"product_id":"tqdl21150-general-electric-150a-2-pole-120240v-thermal-magnetic-molded-case-circuit-breaker","title":"TQDL21150 | General Electric 150A 2-Pole 120\/240V Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TQDL21150 is a molded case circuit breaker designed for dependable circuit protection in residential, commercial, and light industrial electrical systems. This breaker features a 150 Amp current rating and supports 120\/240 VAC operation, ensuring stable protection for branch and feeder circuits. Its plug-in design and thermal magnetic protection provide both convenience and safety in installation and operation.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTQDL21150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ-Line TQDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kAIC @ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTQDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eTQDL21150\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe TQDL21150 is part of General Electric’s Q-Line TQDL Series, known for its compact molded case construction and robust performance. This 2-pole breaker utilizes thermal magnetic trip technology for accurate overload and short-circuit protection. It is compatible with plug-in panelboards and load centers, allowing quick replacement or installation without additional wiring. Designed for both residential and commercial use, it meets UL and CSA standards for safety and performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable Protection: Thermal magnetic trip provides consistent response to overloads and faults.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits easily into plug-in Q-Line panelboards for space-efficient installations.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Offers dual protection for single-phase systems up to 240 VAC.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated at 10 kAIC at 120V for enhanced safety during fault conditions.\u003c\/li\u003e\n\u003cli\u003eEasy Installation: Plug-in connection type allows fast setup and maintenance.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Molded case housing ensures long-term mechanical and electrical integrity.\u003c\/li\u003e\n\u003cli\u003eStandards Compliance: UL and CSA approved for verified reliability and quality assurance.\u003c\/li\u003e\n\u003cli\u003eCommon Trip Feature: Internal mechanism ensures simultaneous disconnection of both poles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TQDL21150 delivers the reliability and precision required for dependable circuit protection in both commercial and residential power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082450176,"sku":"TQDL21150","price":2938.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-09_17.58.38.png?v=1785539714"},{"product_id":"tqdl21175-general-electric-175a-2-pole-120240v-thermal-magnetic-molded-case-circuit-breaker","title":"TQDL21175 | General Electric 175A 2-Pole 120\/240V Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TQDL21175 is a molded case circuit breaker designed to provide dependable overcurrent and short-circuit protection in residential, commercial, and light industrial applications. Rated at 175 Amps and 120\/240 VAC, this 2-pole breaker ensures consistent circuit safety and performance. Its plug-in design and thermal magnetic trip mechanism make it both efficient and easy to install in compatible panel systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 431.215px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eTQDL21175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eQ-Line TQDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e175 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e10 kAIC @ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eTQDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e0.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TQDL21175\u003c\/h4\u003e\n\u003cp\u003eThe TQDL21175 is part of General Electric’s Q-Line TQDL Series, a line of molded case circuit breakers engineered for precision and durability. It features a thermal magnetic protection system that combines overload and instantaneous trip functions for complete circuit safety. The unit’s plug-in configuration allows fast installation into GE Q-Line load centers without additional wiring. Built to meet UL and CSA standards, the TQDL21175 is ideal for use in single-phase systems requiring reliable performance and straightforward maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal Magnetic Trip Unit: Provides reliable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003e2-Pole Design: Offers simultaneous protection for both conductors in single-phase systems.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated 10 kAIC at 120V for enhanced fault protection.\u003c\/li\u003e\n\u003cli\u003ePlug-In Connection: Enables quick installation and secure panelboard integration.\u003c\/li\u003e\n\u003cli\u003eCommon Trip Mechanism: Ensures both poles disconnect together during a fault event.\u003c\/li\u003e\n\u003cli\u003eCompact Form Factor: Fits easily into GE Q-Line load centers for efficient use of space.\u003c\/li\u003e\n\u003cli\u003eCompliance and Safety: UL and CSA approved for verified quality and operational reliability.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Molded case ensures long-lasting mechanical and electrical integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TQDL21175 delivers the reliability and precision required for effective circuit protection in demanding electrical distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082515712,"sku":"TQDL21175","price":3251.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-09_18.07.06.png?v=1785539715"},{"product_id":"sela24at0150-general-electric-150a-2-pole-480v-spectra-series-solid-state-circuit-breaker","title":"SELA24AT0150 | General Electric 150A 2-Pole 480V Spectra Series Solid-State Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric SELA24AT0150 is a 2-pole solid-state molded case circuit breaker from the Spectra Series, designed for high-performance power protection in commercial and industrial electrical systems. Rated for 150 amps and 480 VAC, this breaker offers a 65 kA interrupting capacity, ensuring dependable short-circuit and overload protection. Its advanced LSI (Long-Time, Short-Time, and Instantaneous) trip functions provide accurate and customizable circuit management for a range of load conditions.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSELA24AT0150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSELA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kAIC at 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-State Electronic (LSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Short-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable Solid-State\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution and Power Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.25 x 7.75 x 7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 lb (2.49 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eSELA24AT0150\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SELA24AT0150 is part of GE’s Spectra RMS Series, a robust line of molded case circuit breakers engineered for precision and reliability in demanding environments. It features a solid-state electronic trip unit housed in a compact SELA frame, providing superior control and system coordination. The breaker’s bolt-on mounting design supports secure and straightforward installation within Spectra panelboards and switchgear. Built to meet UL and international standards, the SELA24AT0150 is ideal for industrial facilities requiring efficient, high-capacity circuit protection with electronic trip accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Interrupting Capacity: Delivers 65 kAIC at 480 VAC for superior fault current protection.\u003c\/li\u003e\n\u003cli\u003eSolid-State Trip Unit: Provides electronic precision and adjustable time-current characteristics.\u003c\/li\u003e\n\u003cli\u003eLSI Trip Functions: Integrates Long-Time, Short-Time, and Instantaneous protection modes.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Simplifies installation and ensures firm, reliable panel connections.\u003c\/li\u003e\n\u003cli\u003eCompact SELA Frame: Optimized for high-density electrical systems with limited space.\u003c\/li\u003e\n\u003cli\u003eUL Certified: Meets key safety and performance standards for industrial use.\u003c\/li\u003e\n\u003cli\u003eThermal and Magnetic Sensing: Enhances response accuracy under overload or fault conditions.\u003c\/li\u003e\n\u003cli\u003eDurable Industrial Design: Built to withstand rigorous operational demands and environmental stresses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SELA24AT0150 delivers the reliability and precision required for industrial-grade circuit protection and power distribution applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105090674944,"sku":"SELA24AT0150","price":1702.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-04_01.13.35.png?v=1785539960"},{"product_id":"seha24at0150-general-electric-150a-2-pole-480v-spectra-series-solid-state-circuit-breaker","title":"SEHA24AT0150 | General Electric 150A 2-Pole 480V Spectra Series Solid-State Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric SEHA24AT0150 is a 2-pole solid-state molded case circuit breaker from the Spectra Series, engineered for dependable power distribution and circuit protection in industrial and commercial systems. Rated for 150 amps and 480 VAC, it provides 25 kA interrupting capacity at 480V, ensuring effective protection against overloads and short circuits. Its solid-state electronic trip unit with LSI (Long-Time, Short-Time, and Instantaneous) functions offers precise, adjustable protection for a variety of applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSEHA24AT0150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-State (LSI: Long-Time, Short-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLug (Load Side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CE, CSA, HACR, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Reverse Feed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.25 x 7.75 x 7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.89 kg (4.17 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eSEHA24AT0150\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SEHA24AT0150 is part of General Electric’s Spectra RMS Series, a line of molded case circuit breakers known for advanced solid-state trip technology and high system reliability. Built with a compact E-frame design, it provides flexible bolt-on connections for secure installation in panelboards and switchgear. This model’s solid-state trip unit enhances coordination and reduces nuisance tripping through precise time-current characteristics. Designed to meet UL, CE, HACR, CSA, and RoHS standards, the SEHA24AT0150 is suitable for demanding environments requiring consistent and efficient circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolid-State Protection: Utilizes an electronic trip unit for accurate time-current coordination.\u003c\/li\u003e\n\u003cli\u003eLSI Trip Functions: Provides Long-Time, Short-Time, and Instantaneous trip settings for adaptable protection.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Rating: Delivers 25 kAIC at 480 VAC for reliable short-circuit interruption.\u003c\/li\u003e\n\u003cli\u003eCompact E-Frame Design: Enables space-efficient installation in modern distribution systems.\u003c\/li\u003e\n\u003cli\u003eBolt-On Connection: Ensures secure mechanical and electrical connections for stability and safety.\u003c\/li\u003e\n\u003cli\u003eReverse Feed Suitable: Designed for installation flexibility in various system orientations.\u003c\/li\u003e\n\u003cli\u003eUL and CE Certified: Complies with major international safety and performance standards.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Engineered to withstand heavy industrial usage with consistent performance.\u003c\/li\u003e\n\u003cli\u003eThe SEHA24AT0150 delivers the reliability and precision required for industrial, commercial, and utility-grade circuit protection systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105090740480,"sku":"SEHA24AT0150","price":1762.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-04_01.02.53.png?v=1785539961"},{"product_id":"skha26at0800-ge-800a-2-pole-600v-bolt-on-solid-state-molded-case-circuit-breaker","title":"SKHA26AT0800 | GE 800A 2-Pole 600V Bolt-On Solid-State Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric SKHA26AT0800 is a 2-pole molded case circuit breaker designed to provide high-capacity protection for heavy-duty electrical systems. Rated at 800 amps and 600 volts AC, it offers solid-state trip protection for precise long-time, short-time, and instantaneous fault interruption. This bolt-on breaker is part of GE’s Spectra Series, engineered for industrial applications requiring dependable overcurrent protection and advanced trip functions.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSKHA26AT0800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpectra RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSKHA Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-State RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLSI – Long-Time, Short-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kAIC @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic\/Solid State\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Approved, RoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 x 11.75 x 11.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eSKHA26AT0800\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SKHA26AT0800 is part of the GE Spectra Series molded case circuit breaker line, known for reliability and flexibility in power distribution systems. It features a solid-state RMS trip unit with LSI (Long-Time, Short-Time, Instantaneous) protection, offering accurate and repeatable trip performance under varying load conditions. Its bolt-on connection design allows secure installation in Spectra panels and switchboards, supporting high-power industrial environments. Built for 600V AC single-phase operation, this breaker meets UL and CSA standards, ensuring safe and code-compliant operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Current Capacity: 800A rating — Supports demanding power distribution systems.\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 600 VAC — Suitable for heavy-duty industrial and commercial applications.\u003c\/li\u003e\n\u003cli\u003eSolid-State Trip Unit: Provides precise and consistent LSI trip protection.\u003c\/li\u003e\n\u003cli\u003eInterrupting Rating: 50kAIC at 480V — Delivers high short-circuit protection for critical installations.\u003c\/li\u003e\n\u003cli\u003eConnection Type: Bolt-On — Ensures secure, vibration-resistant mounting.\u003c\/li\u003e\n\u003cli\u003eSeries: Spectra RMS — Compatible with GE Spectra panels and accessories.\u003c\/li\u003e\n\u003cli\u003eTrip Functions: LSI — Combines long-time, short-time, and instantaneous protection in one unit.\u003c\/li\u003e\n\u003cli\u003eUL and CSA Approved: Meets industry standards for safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SKHA26AT0800 delivers the reliability and precision required for industrial-grade power management and fault protection.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105099391232,"sku":"SKHA26AT0800","price":5731.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/SKHA26AT0800_Illustration_Front_Original.jpg?v=1785540170"},{"product_id":"thhqb1120af2-ge-20a-1-pole-120240v-arc-fault-bolt-on-circuit-breaker-22kaic","title":"THHQB1120AF2 | GE 20A 1-Pole 120\/240V Arc-Fault Bolt-On Circuit Breaker 22kAIC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe GE THHQB1120AF2 is a 1-pole, 20-amp arc-fault circuit breaker designed for 120\/240 VAC residential and light commercial applications. It combines thermal-magnetic protection with arc-fault detection to prevent overloads, short circuits, and hazardous electrical arcs that can cause fires. Its bolt-on mounting and durable thermoset housing ensure reliable installation and long-lasting performance in GE Q-Line panelboards.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTHHQB1120AF2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArc-Fault Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI – Long-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc-Fault Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFCI – Arc-Fault Circuit Interrupter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlastic, Heat-Resistant Thermoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14–10 Cu\/Al\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.28 x 1.00 x 2.38 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, RoHS, Buy American Act Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.50 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eTHHQB1120AF2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe THHQB1120AF2 is part of GE’s Q-Line Series, built for superior circuit protection in modern electrical systems. Featuring a fixed thermal-magnetic trip unit, it provides precise response to overload and fault conditions. This model includes AFCI (Arc-Fault Circuit Interruption) technology that detects dangerous arc conditions and automatically de-energizes the circuit for safety. Compatible with GE load centers and panelboards, it is ideal for residential branch circuit protection and compliance with current electrical codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated Current: 20 Amps — Provides stable and reliable performance for standard branch circuits.\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 120\/240 VAC — Supports both residential and light commercial single-phase applications.\u003c\/li\u003e\n\u003cli\u003eArc-Fault Protection: Detects and interrupts dangerous electrical arcs to reduce fire risk.\u003c\/li\u003e\n\u003cli\u003eInterrupting Capacity: 22kAIC — High fault-current tolerance for dependable short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eTrip Function: LI (Long-Time \u0026amp; Instantaneous) — Ensures rapid response to both overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eMounting Type: Bolt-On — Secure and vibration-resistant installation in GE Q-Line panelboards.\u003c\/li\u003e\n\u003cli\u003eMaterial: Heat-Resistant Thermoset Case — Provides enhanced structural rigidity and long-term durability.\u003c\/li\u003e\n\u003cli\u003eCompliance: UL Listed, RoHS, and Buy American Act Compliant — Meets key industry and safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THHQB1120AF2 delivers the reliability and precision required for safe, efficient residential and light commercial electrical circuit protection.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105099555072,"sku":"THHQB1120AF2","price":374.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/general-electric-ge-thhqb1120af2-1-pole-20-amp-240v-circuit-breaker-iso-600.jpg?v=1785540174"},{"product_id":"fbn16te040rv-ge-1-pole-40a-600v-bolt-on-molded-case-circuit-breaker","title":"FBN16TE040RV | GE 1-Pole 40A 600V Bolt-On Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"439\" data-start=\"171\"\u003eThe General Electric FBN16TE040RV is a 1-pole, 40-amp, 600V thermal magnetic molded case circuit breaker designed for industrial and commercial electrical protection. It features a 65kA interrupting rating at 480V, providing reliable interruption of high fault currents. The FBN16TE040RV uses a bolt-on mounting style and includes long-time and instantaneous trip functions to safeguard circuits against overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFBN16TE040RV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFB100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHBLF2 \/ Record Plus½\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13–158 °F (-25–70 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, NOM, IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.615 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eFBN16TE040RV\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FBN16TE040RV is part of GE’s FB100 Series, specifically designed for robust performance in industrial and commercial systems. Its construction incorporates double-break rotary contact structures and advanced ablative materials to improve interruption capabilities and reduce arc flash energy. The breaker is compatible with standard panelboards and AD-type GE panels, featuring bolt-on load and line connections for secure installation. Certified to UL, CSA, NOM, and IEC standards, it ensures compliance with international safety requirements while offering consistent, high-performance protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent Rating: 40 Amps – Supports moderate to high-load circuits in commercial and industrial applications.\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 600V AC – Designed for single-phase 600V electrical systems.\u003c\/li\u003e\n\u003cli\u003eInterrupting Capacity: 65kA – Safely interrupts short-circuit currents at 480V.\u003c\/li\u003e\n\u003cli\u003eProtection Type: Thermal Magnetic – Provides responsive overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eTrip Functions: Long-Time and Instantaneous – Ensures precise protection for branch circuits.\u003c\/li\u003e\n\u003cli\u003eMounting Type: Bolt-On – Securely mounts to compatible panelboards.\u003c\/li\u003e\n\u003cli\u003eFrame Type: FB – Compatible with standard internal accessories and panel configurations.\u003c\/li\u003e\n\u003cli\u003eStandards: UL, CSA, NOM, IEC – Meets recognized international safety and performance requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FBN16TE040RV delivers the reliability and precision required for industrial and commercial circuit protection applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105106993408,"sku":"FBN16TE040RV","price":657.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-10-28_00.23.02.png?v=1785540380"},{"product_id":"tfc36225a-general-electric-molded-case-circuit-breaker-225a-600v-3-pole","title":"TFC36225A | General Electric Molded Case Circuit Breaker, 225A, 600V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"171\" data-end=\"439\"\u003eThe General Electric TFC36225A is a molded case circuit breaker designed for three-phase power distribution systems. Rated at 225 amps and 600 VAC, it provides reliable overload and short-circuit protection in industrial and commercial applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 382.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eTFC36225A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eTFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e600 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eHigh fault current capacity (series dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eTFC frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003ePanelboard or switchboard installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 10px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 10px;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eIndustrial, commercial, and utility distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eApprox. 9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TFC36225A\u003c\/h4\u003e\n\u003cp\u003eThe TFC36225A is part of GE’s TFC Series molded case circuit breakers, built for dependable electrical protection in medium-capacity systems. With a 3-pole configuration and thermal-magnetic trip unit, it ensures accurate fault detection and interruption. This breaker is UL-listed and ANSI compliant, making it suitable for use in switchboards, panelboards, and motor control centers. Its rugged molded housing supports long-term durability and consistent performance in demanding environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTFC Series: GE molded case breaker family for reliable system protection.\u003c\/li\u003e\n\u003cli\u003e225A Rating: Supports medium-duty electrical distribution loads.\u003c\/li\u003e\n\u003cli\u003e3-Pole Design: Provides balanced protection for three-phase systems.\u003c\/li\u003e\n\u003cli\u003e600 VAC Maximum: Rated for industrial and commercial distribution applications.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip: Ensures accurate overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eDurable Housing: Molded case construction for long service life.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets industry safety and compliance standards.\u003c\/li\u003e\n\u003cli\u003eVersatile Applications: Suitable for panelboards, switchboards, and MCCs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TFC36225A delivers the reliability and protection required for safe and efficient power distribution in demanding environments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105205657856,"sku":"TFC36225A","price":4255.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TFC36225A-new-1.jpg?v=1785542526"},{"product_id":"sgha36at0600-general-electric-spectra-series-molded-case-circuit-breaker-600a-600v-3-pole","title":"SGHA36AT0600 | General Electric Spectra Series Molded Case Circuit Breaker, 600A, 600V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"171\" data-end=\"439\"\u003eThe General Electric SGHA36AT0600 is a molded case circuit breaker designed for three-phase power distribution systems. Rated at 600 amps and 600 VAC, it provides dependable overload and short-circuit protection for industrial and commercial electrical applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eSGHA36AT0600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eSpectra Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e600 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eHigh fault current capacity (series dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eSGHA frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003ePanelboard or switchboard installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eIndustrial, commercial, and utility distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.1239%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7067%; height: 19.6px;\"\u003eApprox. 18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SGHA36AT0600\u003c\/h4\u003e\n\u003cp\u003eThe SGHA36AT0600 is part of GE’s Spectra Series molded case circuit breakers, engineered for heavy-duty power distribution and protection. This breaker features a 3-pole design with a thermal-magnetic trip unit for accurate fault interruption. It is UL listed and ANSI compliant, ensuring safety and performance in demanding environments. Built with a rugged molded housing, the SGHA36AT0600 is ideal for use in panelboards, switchboards, and motor control centers where reliable high-capacity protection is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpectra Series: GE molded case breaker family designed for reliable distribution.\u003c\/li\u003e\n\u003cli\u003e3-Pole Design: Protects three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e600A Rating: Supports high-capacity power distribution.\u003c\/li\u003e\n\u003cli\u003e600 VAC Maximum Voltage: Handles demanding industrial loads.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip: Provides precise overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eDurable Molded Case: Rugged housing ensures long service life.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets industry safety and performance standards.\u003c\/li\u003e\n\u003cli\u003eVersatile Applications: Suitable for panelboards, switchboards, and MCCs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SGHA36AT0600 delivers the reliability and protection required for heavy-duty commercial and industrial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105206018304,"sku":"SGHA36AT0600","price":2203.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/SGHA36AT0600_Illustration.jpg?v=1785542532"},{"product_id":"tbc43400f14g-general-electric-molded-case-circuit-breaker-400a-600v-3-pole","title":"TBC43400F14G | General Electric Molded Case Circuit Breaker, 400A, 600V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric TBC43400F14G is a molded case circuit breaker designed for dependable protection of electrical distribution systems. Rated at 400 amps with a 3-pole configuration, it provides overload and short-circuit protection for industrial and commercial power applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eTBC43400F14G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eTBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003e600 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eSeries dependent – high fault interruption capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eTBC frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003ePanelboard or switchboard installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eRequires installation in approved housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eIndustrial, commercial, and utility distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7643%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0663%;\"\u003eApprox. 14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TBC43400F14G\u003c\/h4\u003e\n\u003cp\u003eThe TBC43400F14G is part of GE’s TBC series of molded case circuit breakers, engineered for high reliability in power distribution networks. Built with a rugged molded housing, this breaker supports continuous-duty operation and fault protection in three-phase systems. It is designed for panelboard and switchboard mounting, with compliance to UL and ANSI standards. The TBC43400F14G is widely applied in manufacturing facilities, commercial buildings, and utility systems requiring medium-capacity circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTBC Series Breaker: Part of GE’s molded case breaker family for power distribution.\u003c\/li\u003e\n\u003cli\u003e3-Pole Design: Provides balanced protection for three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e400A Rating: Supports medium-to-high capacity distribution circuits.\u003c\/li\u003e\n\u003cli\u003e600 VAC Maximum: Handles industrial and commercial system voltages.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip: Ensures precise overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eDurable Molded Case: Built for rugged and continuous operation.\u003c\/li\u003e\n\u003cli\u003eUL and ANSI Certified: Meets industry electrical protection standards.\u003c\/li\u003e\n\u003cli\u003eVersatile Use: Suitable for panelboards, switchboards, and MCC applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TBC43400F14G delivers the reliability and protection required for industrial and commercial power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105206247680,"sku":"TBC43400F14G","price":2124.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/1348735684__98481.1459310759.jpg?v=1785542539"},{"product_id":"teyl3060b-general-electric-molded-case-circuit-breaker-60a-480v-3-pole","title":"TEYL3060B | General Electric Molded Case Circuit Breaker, 60A, 480V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TEYL3060B is a molded case circuit breaker designed for reliable circuit protection in commercial and industrial electrical systems. With a 3-pole, 60-amp configuration, it provides dependable overload and short-circuit protection for low-voltage distribution networks.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eTEYL3060B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eTEYL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003e480 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eSeries dependent – high fault interruption capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eTEYL frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003ePanelboard \/ load center installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eCommercial and industrial low-voltage distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.2197%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6108%; height: 19.6px;\"\u003eApprox. 2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TEYL3060B\u003c\/h4\u003e\n\u003cp\u003eThe TEYL3060B is part of GE’s TEYL Series molded case circuit breakers, built for compact and efficient power distribution. Rated for up to 480 VAC, this breaker features a thermal-magnetic trip unit to ensure accurate protection against overloads and faults. Designed for panelboard and load center applications, it is UL-listed and meets ANSI\/IEEE standards. Its rugged molded housing ensures long service life, making it suitable for a wide range of building and facility power systems.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTEYL Series: General Electric’s molded case breakers for panelboard applications.\u003c\/li\u003e\n\u003cli\u003e3-Pole Design: Protects three-phase distribution systems.\u003c\/li\u003e\n\u003cli\u003e60A Rating: Provides medium-capacity electrical circuit protection.\u003c\/li\u003e\n\u003cli\u003eVoltage Capability: Rated for up to 480 VAC operation.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip: Ensures precise overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eCompact Construction: Fits easily into load centers and panelboards.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets industry safety and performance standards.\u003c\/li\u003e\n\u003cli\u003eDurable Housing: Molded case design ensures long-term reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TEYL3060B delivers the reliability and precision required for safe and efficient power distribution in commercial and industrial environments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105206313216,"sku":"TEYL3060B","price":755.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_3e918d86-22a8-4fbb-aa73-ae97f3ab6a59.webp?v=1785542541"},{"product_id":"thed136150-general-electric-thed-series-circuit-breaker-150a-600v-3-pole","title":"THED136150 | General Electric THED Series Circuit Breaker, 150A, 600V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric THED136150 is a 3-pole molded case circuit breaker rated for 150 amps and up to 600 VAC. It provides dependable overload and short-circuit protection, making it suitable for industrial, commercial, and utility distribution systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eTHED136150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003e600 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eHigh fault current withstand capability (series dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eTHED frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003ePanelboard or switchboard installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eIndustrial, commercial, and utility distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.2231%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6075%; height: 19.6px;\"\u003eApprox. 5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THED136150\u003c\/h4\u003e\n\u003cp\u003eThe THED136150 is part of GE’s THED Series of molded case circuit breakers, designed for safe and efficient power distribution. It features a compact molded housing with a thermal-magnetic trip unit for reliable fault interruption. Built for three-phase applications, the breaker is UL-listed and meets ANSI\/IEEE standards for industrial performance. Its robust design makes it ideal for use in panelboards, switchboards, and motor control centers requiring medium-duty circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTHED Series: GE molded case breaker designed for commercial and industrial use.\u003c\/li\u003e\n\u003cli\u003e3-Pole Configuration: Protects three-phase power distribution systems.\u003c\/li\u003e\n\u003cli\u003e150A Rating: Provides reliable protection for medium-load circuits.\u003c\/li\u003e\n\u003cli\u003e600 VAC Maximum Voltage: Suitable for a wide range of distribution systems.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip: Ensures precise overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eDurable Molded Case: Compact and rugged housing for harsh environments.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets industry safety and compliance standards.\u003c\/li\u003e\n\u003cli\u003eVersatile Applications: Commonly used in panelboards, switchboards, and MCCs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THED136150 delivers the reliability and protection required for safe and efficient three-phase electrical distribution.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105208410368,"sku":"THED136150","price":3160.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/general-electric-ge-thed136150-3-pole-150-amp-600v-circuit-breaker-front-600.jpg?v=1785542550"},{"product_id":"sfda36an0250-general-electric-spectra-series-circuit-breaker-250a-600v-3-pole","title":"SFDA36AN0250 | General Electric Spectra Series Circuit Breaker, 250A, 600V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric SFDA36AN0250 is a 3-pole molded case circuit breaker designed for safe and reliable protection of electrical systems. With a 250-amp rating, it provides dependable overload and short-circuit protection for commercial and industrial power distribution applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 394.467px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eSFDA36AN0250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eSpectra Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003e600 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.0667px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 22.0667px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 22.0667px;\"\u003eThermal-magnetic trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eSeries-dependent, high fault withstand capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003ePanelboard or switchboard installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eSFDA frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eIndustrial, commercial, and utility distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.4903%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1588%; height: 19.6px;\"\u003eApprox. 6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SFDA36AN0250\u003c\/h4\u003e\n\u003cp\u003eThe SFDA36AN0250 is part of GE’s Spectra Series circuit breaker family, engineered for durability and consistent performance in electrical distribution systems. This molded case breaker offers a 600 VAC rating and is designed to protect three-phase circuits from faults and overloads. It is UL-listed, ensuring compliance with industry safety standards. With its compact molded housing and robust design, the SFDA36AN0250 is well-suited for use in switchboards, panelboards, and motor control centers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpectra Series Breaker: Belongs to GE’s family of molded case breakers for reliable distribution.\u003c\/li\u003e\n\u003cli\u003e3-Pole Protection: Provides balanced coverage for three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e250A Rating: Suitable for medium-capacity power distribution.\u003c\/li\u003e\n\u003cli\u003eHigh Voltage Capability: Rated for systems up to 600 VAC.\u003c\/li\u003e\n\u003cli\u003eMolded Case Design: Ensures rugged durability and compact form factor.\u003c\/li\u003e\n\u003cli\u003eOverload and Short-Circuit Protection: Safeguards equipment and circuits from electrical faults.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Complies with safety and performance standards.\u003c\/li\u003e\n\u003cli\u003eWide Application Use: Ideal for commercial, industrial, and utility distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SFDA36AN0250 delivers the reliability and protection required for medium-duty power distribution in demanding environments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105208541440,"sku":"SFDA36AN0250","price":3467.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/sfda36an0250-1_8cd56a82-b52d-4bf2-8e67-cb23410754fc.jpg?v=1785542553"},{"product_id":"skhb36bb1200-general-electric-molded-case-circuit-breaker-1200a-600v-3-pole","title":"SKHB36BB1200 | General Electric Molded Case Circuit Breaker, 1200A, 600V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric SKHB36BB1200 is a molded case circuit breaker designed for high-capacity electrical distribution systems. With a 3-pole, 1200-amp rating, it provides dependable protection against overloads and short circuits in industrial and commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSKHB36BB1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSKHB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e600 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e1200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSolid-state or thermal-magnetic (series dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eHigh fault current withstand capability (per UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003ePanelboard or switchboard installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSKHB frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eIndustrial, utility, and large commercial distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eApprox. 36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SKHB36BB1200\u003c\/h4\u003e\n\u003cp\u003eThe SKHB36BB1200 is part of GE’s SKHB series of molded case circuit breakers, engineered for reliable power distribution and fault protection. Built with a heavy-duty housing and advanced trip technology, it ensures safe interruption of high fault currents. The breaker is designed for use in switchboards, panelboards, and power distribution units where high amperage protection is required. With UL compliance and robust performance, it is well-suited for utilities, manufacturing plants, and large commercial facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Amperage Protection: Rated for 1200A, suitable for heavy-duty power systems.\u003c\/li\u003e\n\u003cli\u003eSKHB Series: Part of GE’s molded case breaker family for industrial distribution.\u003c\/li\u003e\n\u003cli\u003e3-Pole Design: Provides balanced protection across three-phase systems.\u003c\/li\u003e\n\u003cli\u003eReliable Interruption: Protects circuits from overloads and short-circuits.\u003c\/li\u003e\n\u003cli\u003eDurable Housing: Molded case construction ensures rugged performance.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Complies with safety and performance standards.\u003c\/li\u003e\n\u003cli\u003eFlexible Applications: Designed for switchboards, panelboards, and distribution units.\u003c\/li\u003e\n\u003cli\u003eIndustrial-Grade Reliability: Built for continuous operation in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SKHB36BB1200 delivers the reliability and protection required for large-scale electrical distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105208639744,"sku":"SKHB36BB1200","price":7463.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Photoroom_20240524_103055.jpg?v=1785542555"},{"product_id":"sepa36at0150-general-electric-molded-case-circuit-breaker","title":"SEPA36AT0150 | General Electric Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe General Electric SEPA36AT0150 is a Spectra RMS™ molded case circuit breaker featuring solid-state electronic trip protection. Rated at 150 A, 600 VAC, and 3‑pole\/3‑phase, it delivers reliable current limiting and overcurrent protection.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 274.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e\u003cspan\u003eCircuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eSEPA36AT0150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e\u003cspan\u003eBusway Switch\/Plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eFamily\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003eSpectra Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003eSEPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003eMolded Case \/ 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eAmp Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003e100 kA @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003eSolid State, Current Limiting, Very High Interrupting Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003e6.31\" × 4.12\" × 3.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6684%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%;\"\u003e5.97 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SEPA36AT0150\u003c\/h4\u003e\n\u003cp\u003eThe General Electric SEPA36AT0150 is a molded case circuit breaker from the Spectra Series, engineered for dependable protection of commercial and industrial electrical systems. Rated at 150 A and up to 600 VAC, it features a 3-pole, 3-phase configuration with bolt-on connections for secure installation. With a very high interrupting capacity of 100 kA at 480 V and solid-state trip technology, it delivers precise overcurrent protection and current limiting performance. Built to handle demanding environments, the SEPA36AT0150 combines advanced protection with the rugged reliability of GE’s Spectra line.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Capacity Protection: 100 kA @ 480 V interrupting rating for robust fault handling.\u003c\/li\u003e\n\u003cli\u003eSolid-State Trip: Provides precise, adjustable overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eCurrent Limiting Design: Reduces fault energy for enhanced equipment safety.\u003c\/li\u003e\n\u003cli\u003eHeavy-Duty Build: Molded case construction ensures durability in industrial use.\u003c\/li\u003e\n\u003cli\u003eBolt-On Connection: Secure, reliable installation in panelboards or switchboards.\u003c\/li\u003e\n\u003cli\u003eSpectra Series Reliability: Trusted GE design for consistent, long-term performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SEPA36AT0150 offers high-performance circuit protection with advanced trip technology, making it an ideal choice for safeguarding critical electrical infrastructure in demanding applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105250386176,"sku":"SEPA36AT0150","price":2732.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/SEPA36AT0150.jpg?v=1785543490"}],"url":"https:\/\/alotechparts.com\/collections\/general-electric-pdu-ups-power-distribution.oembed?page=2","provider":"Alo Tech Solutions","version":"1.0","type":"link"}