{"title":"Fluke Parts","description":"\u003cp\u003eAlo Tech stocks 110 Fluke products across medical parts, PLC \u0026amp; I\/O, chassis \u0026amp; rail kits, software \u0026amp; licenses. Popular Fluke families: FLUKE-15B, FLUKE-1577, FLUKE-A3000FC, FLUKE-289-FVF, FLUKE-279-FC-IFL, FLUKE-28II. Every order ships worldwide DDP with duties and taxes included; B2B customers receive a formal quote within 24 hours and can pay by purchase order.\u003c\/p\u003e","products":[{"product_id":"fluke-754-documenting-process-calibrator-hart","title":"754 Fluke Documenting Process Calibrator with HART Communication","description":"\u003cp\u003eGenuine Fluke 754 documenting process calibrator with integrated HART communication for calibrating and maintaining smart transmitters and instrumentation in industrial and process environments. Sources, simulates, and measures pressure, temperature, and electrical signals in one handheld device.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 3405771\u003c\/li\u003e\n\u003cli\u003eFunctions: Voltage (AC\/DC), mA loop with 24V loop power, pressure (via Fluke 750P modules), thermocouples \u0026amp; RTDs, frequency, resistance\u003c\/li\u003e\n\u003cli\u003eBattery: Li-ion 7.2V, 4400mAh, 30Wh, over 8 hours typical\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003eIngress Protection: IP52\u003c\/li\u003e\n\u003cli\u003eDimensions: 136 x 245 x 63 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1.2 kg\u003c\/li\u003e\n\u003cli\u003eAgency Approvals: CAN\/CSA C22.2 No 1010.1-92, ANSI\/ISA S82.01-1994, UL3111, EN61010-1:1993\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOrdering \u0026amp; Availability\u003c\/h3\u003e\u003cp\u003eBulk and DDP pricing available for resellers, integrators, and maintenance teams. Request a quote (RFQ) for volume orders.\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":48962401730816,"sku":"3405771","price":11688.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/3_856a51e1-977e-4355-8a86-558df74d28e2.png?v=1783523083"},{"product_id":"fluke-376-fc-true-rms-clamp-meter-with-iflex","title":"376 FC Fluke True-RMS Clamp Meter with iFlex, 1000A\/2500A AC","description":"\u003cp\u003eGenuine Fluke 376 FC true-RMS clamp meter with iFlex flexible current probe for industrial and commercial electrical troubleshooting. Wireless Fluke Connect logging and VFD low-pass filter for accurate non-linear signal measurement, plus inrush current capture.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 5065965\u003c\/li\u003e\n\u003cli\u003eAC Current (Jaw): 999.9 A, accuracy 2% ±5 digits (10-100Hz)\u003c\/li\u003e\n\u003cli\u003eAC Current (iFlex Probe): 2500 A, accuracy 3% ±5 digits (5-500Hz)\u003c\/li\u003e\n\u003cli\u003eAC\/DC Voltage: 1000 V, accuracy 1% ±5 digits\u003c\/li\u003e\n\u003cli\u003eResistance: 60 kΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance: 1000 µF\u003c\/li\u003e\n\u003cli\u003eSafety Rating: CAT III 1000V \/ CAT IV 600V\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003eDimensions: 249 x 85 x 45 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 395 g\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOrdering \u0026amp; Availability\u003c\/h3\u003e\u003cp\u003eBulk and DDP pricing available for resellers, integrators, and maintenance teams. Request a quote (RFQ) for volume orders.\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":48962401992960,"sku":"5065965","price":580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2_9c34bb7d-a2b7-44eb-a71c-84c09a04d938.png?v=1783523085"},{"product_id":"fluke-1587-fc-insulation-multimeter-h57xi","title":"1587 FC Fluke Insulation Multimeter, 2GΩ Insulation Test","description":"\u003cp\u003eGenuine Fluke 1587 FC insulation multimeter with Fluke Connect wireless capability for insulation resistance testing, troubleshooting, and diagnostics on electrical equipment. Measures AC\/DC voltage, resistance, capacitance, frequency, and temperature with PI\/DAR timed ratio tests.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 4691215\u003c\/li\u003e\n\u003cli\u003eInsulation Resistance Range: 0.01 MΩ to 2 GΩ\u003c\/li\u003e\n\u003cli\u003eTest Voltages: 50, 100, 250, 500, 1000 V\u003c\/li\u003e\n\u003cli\u003eDC\/AC Voltage: 1000 V\u003c\/li\u003e\n\u003cli\u003eTemperature Measurement: -40°C to 537°C\u003c\/li\u003e\n\u003cli\u003eSafety Rating: CAT IV 600V \/ CAT III 1000V\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20°C to 55°C\u003c\/li\u003e\n\u003cli\u003eDimensions: 5.0 x 10.0 x 20.3 cm\u003c\/li\u003e\n\u003cli\u003eWeight: 550 g\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOrdering \u0026amp; Availability\u003c\/h3\u003e\u003cp\u003eBulk and DDP pricing available for resellers, integrators, and maintenance teams. Request a quote (RFQ) for volume orders.\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":48962402189568,"sku":"4691215","price":1255.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/LR150_11.png?v=1783523086"},{"product_id":"fluke-117-digital-multimeterswith-non-contact-voltage","title":"117 Fluke Electrician's Digital Multimeter with Non-Contact Voltage","description":"\u003cp\u003eGenuine Fluke 117 compact true-RMS digital multimeter designed for electricians, featuring integrated non-contact voltage detection (VoltAlert) and automatic AC\/DC voltage selection for commercial, industrial, and institutional electrical work.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 2538815\u003c\/li\u003e\n\u003cli\u003eDC\/AC Voltage: 600 V\u003c\/li\u003e\n\u003cli\u003eAC\/DC Current: 10 A\u003c\/li\u003e\n\u003cli\u003eResistance: 40 MΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance: 9999 µF\u003c\/li\u003e\n\u003cli\u003eSafety Rating: CAT III 600V\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003eDimensions: 167 x 84 x 46 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 550 g\u003c\/li\u003e\n\u003cli\u003eWarranty: 3 years\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOrdering \u0026amp; Availability\u003c\/h3\u003e\u003cp\u003eBulk and DDP pricing available for resellers, integrators, and maintenance teams. Request a quote (RFQ) for volume orders.\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":48962402353408,"sku":"2538815","price":362.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/LR150_8.png?v=1783523089"},{"product_id":"fluke-375-fc-true-rms-acdc-clamp-meter-qufle","title":"375 FC Fluke True-RMS AC\/DC Clamp Meter, 600A\/1000V","description":"\u003cp\u003eGenuine Fluke 375 FC true-RMS AC\/DC clamp meter with wireless Fluke Connect capability for industrial and commercial electrical troubleshooting. Compatible with the optional iFlex flexible current probe for expanded measurement range up to 2500 A.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 5065976\u003c\/li\u003e\n\u003cli\u003eAC\/DC Current (Jaw): 600 A, accuracy 2% ±5 digits\u003c\/li\u003e\n\u003cli\u003eAC Current (iFlex Probe, optional): 2500 A\u003c\/li\u003e\n\u003cli\u003eAC\/DC Voltage: 1000 V\u003c\/li\u003e\n\u003cli\u003eResistance: 60 kΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance: 1000 µF\u003c\/li\u003e\n\u003cli\u003eSafety Rating: CAT III 1000V \/ CAT IV 600V\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003eDimensions: 249 x 85 x 45 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 395 g\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOrdering \u0026amp; Availability\u003c\/h3\u003e\u003cp\u003eBulk and DDP pricing available for resellers, integrators, and maintenance teams. Request a quote (RFQ) for volume orders.\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":48962402550016,"sku":"5065976","price":638.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/LR150_7.png?v=1783523091"},{"product_id":"fluke-805-fc-vibration-meter-with-cf-bearing-assessment-and-ir-temperature-de8iq","title":"Fluke 805 FC Vibration Meter with CF+ Bearing Assessment and IR Temperature","description":"\u003cp\u003e[shortdesc] Vibration screening, bearing condition, IR temperature, CF+ assessment, and handheld design [\/shortdesc]\u003c\/p\u003e\n\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eOverall machine health and bearing condition checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Frequency Range\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Frequency Range\u003c\/td\u003e\n\u003ctd\u003e4,000 Hz to 20,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeverity Levels\u003c\/td\u003e\n\u003ctd\u003eGood, Satisfactory, Unsatisfactory, Unacceptable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Vibration Measurement\u003c\/td\u003e\n\u003ctd\u003eAcceleration, velocity and displacement units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing Assessment\u003c\/td\u003e\n\u003ctd\u003eCrest Factor+ using direct sensor tip measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd\u003eSpot IR Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Categories\u003c\/td\u003e\n\u003ctd\u003eChillers, fans, cooling towers, centrifugal pumps, positive displacement pumps, air compressors, blowers, and machine tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eUp to 3,500 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eTwo AA alkaline or lithium-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e250 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e25.72 × 16.19 × 9.84 cm (10.13 × 6.38 × 3.875 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.16 kg (2.55 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 50 °C (-4 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 °C to 80 °C (-22 °F to 176 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating \/ Storage Altitude\u003c\/td\u003e\n\u003ctd\u003eSea level to 3,048 m (10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Meter\u003c\/td\u003e\n\u003ctd\u003eLow frequency range 10 Hz to 1,000 Hz; High frequency range 4,000 Hz to 20,000 Hz; Vibration limit 50 g peak (100 g peak-peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D converter; Signal to noise ratio 80 dB; Low frequency sampling rate 20,000 Hz; High frequency sampling rate 80,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01 g to 50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Accuracy\u003c\/td\u003e\n\u003ctd\u003eAt 100 Hz ±5% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Units\u003c\/td\u003e\n\u003ctd\u003eAcceleration: g, m\/sec²; Velocity: in\/sec, mm\/sec; Displacement: mils, mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Thermometer\u003c\/td\u003e\n\u003ctd\u003eRange -20 °C to 200 °C (-4 °F to 392 °F); Accuracy ±2 °C (4 °F); Fixed focal length at approximately 3.8 cm (1.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Sensor Support\u003c\/td\u003e\n\u003ctd\u003eFrequency range 10 Hz to 1,000 Hz; Bias voltage 20 V DC to 22 V DC; Bias current maximum 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware \/ Data\u003c\/td\u003e\n\u003ctd\u003eFactory calibration required; Database on internal flash memory; Upgrade through USB; Memory up to 3,500 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Interfaces\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 full speed communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B 7-pin, stereo audio output jack (3.5 mm audio plug), external sensor jack (SMB connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated Emission\u003c\/td\u003e\n\u003ctd\u003eElectrostatic discharge: EN 61000-4-2; Electromagnetic interference: EN 61000-4-3; RE: CISPR 11, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor+\u003c\/td\u003e\n\u003ctd\u003eCF+ values range from 1 to 16 and increase as bearing condition worsens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Indication\u003c\/td\u003e\n\u003ctd\u003eGreen and red lighting system with on-screen comments indicates how much pressure to apply during measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Health Use\u003c\/td\u003e\n\u003ctd\u003eDesigned for frontline go or no-go vibration screening of bearings and overall machine health\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop Test\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Vibration Limit\u003c\/td\u003e\n\u003ctd\u003e500 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003e805 Vibration Meter; USB cable; Storage case; Belt holster; Quick reference guide; Two AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Sensor\u003c\/td\u003e\n\u003ctd\u003eExternal sensors are supported, but not provided by Fluke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\n\u003ch2\u003eMake Confident Maintenance Decisions Before Failure Happens\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 805 Vibration Meter gives frontline maintenance teams a reliable way to check overall machine health, bearing condition and temperature without complex vibration analysis. Designed for repeatable screening, it helps technicians make fast go or no-go decisions and safely record measurement data when working in the field.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRepeatable vibration screening:\u003c\/strong\u003e Innovative sensor and sensor tip design help reduce measurement variation caused by angle or contact pressure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBearing condition assessment:\u003c\/strong\u003e Crest Factor+ technology supports reliable bearing evaluation using direct sensor tip measurements from 4,000 Hz to 20,000 Hz.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFour-level severity scale:\u003c\/strong\u003e Good, Satisfactory, Unsatisfactory and Unacceptable ratings help teams quickly prioritize maintenance action.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpanded diagnostic visibility:\u003c\/strong\u003e Spot IR temperature measurement adds thermal context to vibration and bearing readings for improved troubleshooting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData Tracking:\u003c\/strong\u003e Excel templates allow operators to transfer values over USB to easily trend diagnostic metrics and evaluate performance over time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eFrontline mechanical troubleshooting teams needing quick machine health checks.\u003c\/li\u003e\n  \u003cli\u003ePredictive maintenance programs tracking vibration trends over time.\u003c\/li\u003e\n  \u003cli\u003eIndustrial plants monitoring bearings, pumps, fans, compressors and blowers.\u003c\/li\u003e\n  \u003cli\u003eFacilities teams making go or no-go maintenance decisions in the field.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Handheld vibration meter\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverall Vibration Range:\u003c\/strong\u003e 10 Hz to 1,000 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBearing CF+ Range:\u003c\/strong\u003e 4,000 Hz to 20,000 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeverity Levels:\u003c\/strong\u003e Good, Satisfactory, Unsatisfactory, Unacceptable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0.01 g to 50 g\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmplitude Units:\u003c\/strong\u003e Acceleration, velocity and displacement\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIR Temperature Range:\u003c\/strong\u003e -20 °C to 200 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory Capacity:\u003c\/strong\u003e Up to 3,500 measurements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e USB 2.0 full speed communication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP54\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eStrengthen Your Predictive Maintenance Workflow\u003c\/h2\u003e\n\u003cp\u003eChoose the Fluke 805 Vibration Meter to identify machine health issues earlier, improve maintenance confidence and support smarter asset decisions. \u003cstrong\u003eOrder today\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49023697518848,"sku":"FLUKE-805FC-NEW","price":3234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-805FC_1_7e7ac582-3897-40a3-af68-5a53536acf37.webp?v=1784296457"},{"product_id":"fluke-116-hvac-true-rms-multimeter-with-temperature-and-microamps-ofdsm","title":"Fluke 116 HVAC True-RMS Multimeter with Temperature and Microamps","description":"\u003cp\u003e[shortdesc] True-RMS HVAC multimeter featuring built-in thermometer, microamp flame sensor testing, LoZ ghost voltage prevention, and CAT III 600V safety rating. [\/shortdesc]\u003c\/p\u003e\n\n\u003cp\u003e[properties]\u003c\/p\u003e \n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e \n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e \n\u003ctbody\u003e \n\u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eFluke 116\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eProduct Type\u003c\/td\u003e \u003ctd\u003eHVAC Digital Multimeter\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eMeasurement Type\u003c\/td\u003e \u003ctd\u003eTrue-RMS\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eVoltage Range\u003c\/td\u003e \u003ctd\u003eUp to 600 V AC\/DC\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eMicroamps Measurement\u003c\/td\u003e \u003ctd\u003eUp to 600 microamps\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eTemperature Range\u003c\/td\u003e \u003ctd\u003e-40 degrees C to 400 degrees C\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eResistance Range\u003c\/td\u003e \u003ctd\u003eUp to 40 Megohms\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eCapacitance Range\u003c\/td\u003e \u003ctd\u003eUp to 9999 microfarads\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eFrequency Range\u003c\/td\u003e \u003ctd\u003eUp to 50 kHz\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eDisplay\u003c\/td\u003e \u003ctd\u003e6000 counts digital display with 33-segment bar graph\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eSafety Rating\u003c\/td\u003e \u003ctd\u003eCAT III 600 V\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eBattery\u003c\/td\u003e \u003ctd\u003e9 V Alkaline (IEC 6LR61)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eBattery Life\u003c\/td\u003e \u003ctd\u003eApprox. 400 hours (without backlight)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eOperating Temperature\u003c\/td\u003e \u003ctd\u003e-10 degrees C to +50 degrees C\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eStorage Temperature\u003c\/td\u003e \u003ctd\u003e-40 degrees C to +60 degrees C\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eStandards\u003c\/td\u003e \u003ctd\u003eIEC 61010-1; IEC 61010-2-033; IEC 61326-1\u003c\/td\u003e \u003c\/tr\u003e \n\u003c\/tbody\u003e \u003c\/table\u003e \n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\n\u003cp\u003e[specifications]\u003c\/p\u003e \n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e \n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e \n\u003ctbody\u003e \n\u003ctr\u003e \u003ctd\u003eDC Voltage\u003c\/td\u003e \u003ctd\u003e6.000 V \/ 60.00 V \/ 600.0 V; Accuracy plus\/minus (0.5% + 2)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eAC Voltage (True-RMS)\u003c\/td\u003e \u003ctd\u003e6.000 V \/ 60.00 V \/ 600.0 V; Accuracy plus\/minus (1.0% + 3)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eDC Millivolts\u003c\/td\u003e \u003ctd\u003e600.0 mV; Accuracy plus\/minus (7.5% + 2)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eAC Millivolts (True-RMS)\u003c\/td\u003e \u003ctd\u003e600.0 mV; Accuracy plus\/minus (1.0% + 3)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eResistance\u003c\/td\u003e \u003ctd\u003e600.0 Ohms to 40.00 Megohms; Accuracy plus\/minus (0.9% + 1)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eContinuity\u003c\/td\u003e \u003ctd\u003eBeeper on less than 20 Ohms; off greater than 250 Ohms\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eCapacitance\u003c\/td\u003e \u003ctd\u003e1000 nF to 9999 microfarads; Accuracy up to plus\/minus (1.9% + 2)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eTemperature (Type-K)\u003c\/td\u003e \u003ctd\u003e-40 degrees C to 400 degrees C; Accuracy plus\/minus (1% + 10)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eAC Microamps (True-RMS)\u003c\/td\u003e \u003ctd\u003e600.0 microamps; Accuracy plus\/minus (1.5% + 3)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eDC Microamps\u003c\/td\u003e \u003ctd\u003e600.0 microamps; Accuracy plus\/minus (1.0% + 2)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eFrequency\u003c\/td\u003e \u003ctd\u003e99.99 Hz to 50.00 kHz; Accuracy plus\/minus (0.1% + 2)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eDiode Test\u003c\/td\u003e \u003ctd\u003e2.000 V; Accuracy plus\/minus (0.9% + 2)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eDisplay Update Rate\u003c\/td\u003e \u003ctd\u003eDigital: 4\/sec; Bar graph: 32\/sec\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eMaximum Voltage\u003c\/td\u003e \u003ctd\u003e600 V between any terminal and ground\u003c\/td\u003e \u003c\/tr\u003e \n\u003c\/tbody\u003e \u003c\/table\u003e \n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\n\u003cp\u003e[accesories]\u003c\/p\u003e \n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e \n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e \n\u003ctbody\u003e \n\u003ctr\u003e \u003ctd\u003eIncluded\u003c\/td\u003e \u003ctd\u003eTL75 Test Leads; 80BK-A Integrated Temperature Probe; Holster; User documentation; 9 V battery (installed)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eOptional Accessories\u003c\/td\u003e \u003ctd\u003eMagnetic hanger (ToolPak compatible)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\n\u003ch2\u003ePrecision HVAC Diagnostics in a Compact Tool\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 116 HVAC True-RMS Multimeter\u003c\/strong\u003e is purpose-built for HVAC professionals who demand accuracy, speed, and reliability in the field. Designed specifically for troubleshooting heating, ventilation, and air conditioning systems, it integrates temperature and microamp measurement capabilities to quickly identify faults and optimize performance. With Fluke trusted engineering, this meter delivers consistent results even in complex electrical environments.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Temperature Measurement:\u003c\/strong\u003e Integrated thermometer supports precise HVAC diagnostics from -40 degrees C to 400 degrees C, eliminating the need for separate tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroamp Flame Sensor Testing:\u003c\/strong\u003e Accurately measure microamps to test flame rods and ensure safe burner operation in HVAC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Accuracy:\u003c\/strong\u003e Reliable readings on non-linear signals, ensuring accurate diagnostics across modern electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Input Impedance (LoZ):\u003c\/strong\u003e Helps prevent false readings caused by ghost voltage, improving troubleshooting confidence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Visibility \u0026amp; Usability:\u003c\/strong\u003e Large white LED backlight and ergonomic design enable one-handed operation in low-light or tight spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC system troubleshooting and maintenance\u003c\/li\u003e\n\u003cli\u003eFlame sensor testing in heating systems\u003c\/li\u003e\n\u003cli\u003eElectrical diagnostics in commercial and residential environments\u003c\/li\u003e\n\u003cli\u003eField service technicians requiring compact, accurate tools\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance and system performance verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e Up to 600V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40 degrees C to 400 degrees C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroamp Measurement:\u003c\/strong\u003e Up to 600 microamps AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Range:\u003c\/strong\u003e Up to 40 Megohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 9999 microfarads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000-count digital display with bar graph\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Up to 400 hours typical without backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10 degrees C to +50 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eUpgrade Your HVAC Toolkit Today\u003c\/h2\u003e\n\u003cp\u003eEquip your team with the \u003cstrong\u003eFluke 116\u003c\/strong\u003e for faster, more accurate diagnostics. \u003cstrong\u003eOrder today\u003c\/strong\u003e and improve service efficiency.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49023698632960,"sku":"FLUKE-116-NEW","price":323.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-116_1_1f30d34f-1710-4126-a100-cfcd23f56dcc.webp?v=1784296486"},{"product_id":"fluke-i30-acdc-current-clamp-30a-hall-effect-probe-jamhu","title":"Fluke i30 AC\/DC Current Clamp 30A Hall Effect Probe","description":"\u003cp\u003e[shortdesc] Professional Hall effect AC\/DC current clamp with 30A DC \/ 20A AC range, 100mV\/A output sensitivity, and CAT III 300V safety rating for non-intrusive circuit testing.[\/shortdesc]\u003c\/p\u003e\n\n\u003cp\u003e[properties]\u003c\/p\u003e \n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e \n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e \n\u003ctbody\u003e \n\u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eFluke i30\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eProduct Type\u003c\/td\u003e \u003ctd\u003eAC\/DC Current Clamp\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eMeasurement Technology\u003c\/td\u003e \u003ctd\u003eHall Effect\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eCurrent Range (DC)\u003c\/td\u003e \u003ctd\u003e30 mA to 30 A\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eCurrent Range (AC)\u003c\/td\u003e \u003ctd\u003e30 mA to 20 A rms\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eUsable Current Range\u003c\/td\u003e \u003ctd\u003e5 mA to 30 A DC; 30 mA to 20 A AC rms\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eFrequency Range\u003c\/td\u003e \u003ctd\u003eDC to 20 kHz (0.5 dB)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eOutput Sensitivity\u003c\/td\u003e \u003ctd\u003e100 mV\/A\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eOutput Connection\u003c\/td\u003e \u003ctd\u003e4 mm safety banana connector\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eMaximum Conductor Size\u003c\/td\u003e \u003ctd\u003e19 mm diameter\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eSafety Rating\u003c\/td\u003e \u003ctd\u003eCAT III 300 V\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e9 V Alkaline battery (IEC 6LR61)\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eBattery Life\u003c\/td\u003e \u003ctd\u003e30 hours with low battery indicator\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eCable Length\u003c\/td\u003e \u003ctd\u003e1.5 m\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e \u003ctd\u003e183 mm x 71 mm x 25 mm\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e250 g\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eOperating Temperature\u003c\/td\u003e \u003ctd\u003e0 °C to +50 °C\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eStorage Temperature\u003c\/td\u003e \u003ctd\u003e-20 °C to +85 °C\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eOperating Humidity\u003c\/td\u003e \u003ctd\u003e15% to 85% (non-condensing)\u003c\/td\u003e \u003c\/tr\u003e \n\u003c\/tbody\u003e \u003c\/table\u003e \n\u003cp\u003e[\/properties]\u003c\/p\u003e \n\n\u003cp\u003e[specifications]\u003c\/p\u003e \n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e \n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e \n\u003ctbody\u003e \n\u003ctr\u003e \u003ctd\u003eAccuracy (at +25 °C)\u003c\/td\u003e \u003ctd\u003eDC: +\/-1% of reading +\/- 2 mA; AC: +\/-0.5% of reading +\/- 2 mA\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eResolution\u003c\/td\u003e \u003ctd\u003e+\/-1 mA\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eCrest Factor\u003c\/td\u003e \u003ctd\u003e1.4\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eLoad Impedance\u003c\/td\u003e \u003ctd\u003e\u0026gt; 100 k Ohms and ≤ 100 pF\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eConductor Position Sensitivity\u003c\/td\u003e \u003ctd\u003e+\/-1% relative to center reading\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eTemperature Coefficient\u003c\/td\u003e \u003ctd\u003e+\/-0.01% of reading per °C\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eWorking Voltage\u003c\/td\u003e \u003ctd\u003e300 V AC rms or DC\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eSafety Standards\u003c\/td\u003e \u003ctd\u003eBS EN 61010-1: 2001; BS EN 61010-2-032: 2002; BS EN 61010-031: 2002\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eEMC Standards\u003c\/td\u003e \u003ctd\u003eEN 61326: 1998 +A1, A2, and A3\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003eOutput Zero Adjustment\u003c\/td\u003e \u003ctd\u003eManual adjust via thumbwheel\u003c\/td\u003e \u003c\/tr\u003e \n\u003ctr\u003e \u003ctd\u003ePollution Degree\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \n\u003c\/tbody\u003e \u003c\/table\u003e \n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\n\u003ch2\u003ePrecision AC\/DC Current Measurement Without Circuit Interruption\u003c\/h2\u003e\n\u003cp\u003eThe Fluke i30 AC\/DC Current Clamp is engineered for professionals who require accurate, non-intrusive current measurement in demanding environments. Utilizing advanced Hall effect technology, this clamp enables precise readings of both AC and DC currents without breaking the circuit. Designed for seamless integration with digital multimeters and recording instruments, it delivers reliable performance for electrical diagnostics, maintenance, and troubleshooting tasks.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHall Effect Sensing Technology:\u003c\/strong\u003e Accurately measures both AC and DC current with high sensitivity, ensuring reliable diagnostics across a wide range of electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Supports 30 mA to 30 A DC and 30 mA to 20 A AC rms, making it suitable for low and high current applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Intrusive Operation:\u003c\/strong\u003e Clamp design allows safe current measurement without interrupting circuits, reducing downtime and risk during testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Frequency Response:\u003c\/strong\u003e Covers DC to 20 kHz bandwidth, enabling accurate analysis of both steady-state and dynamic signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Equipped with 4 mm banana plug connectors for direct use with multimeters, recorders, and other recording devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical maintenance and troubleshooting in commercial facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial equipment diagnostics and current monitoring\u003c\/li\u003e\n\u003cli\u003eHVAC system testing and performance verification\u003c\/li\u003e\n\u003cli\u003eField service engineers requiring portable measurement tools\u003c\/li\u003e\n\u003cli\u003eLaboratory and test bench current analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMeasure Current Safely and Accurately Today\u003c\/h2\u003e\n\u003cp\u003eUpgrade your diagnostic toolkit with the Fluke i30 for precise, reliable current measurements. \u003cstrong\u003eOrder today\u003c\/strong\u003e and improve your testing efficiency.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49023698731264,"sku":"FLUKE-I30-AC\/DC-NEW","price":751.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-I30-AC-DC_1_c4def35d-f2cc-4f82-bab6-a226fb32d216.webp?v=1784296487"},{"product_id":"fluke-i1010-acdc-current-clamp-1000a-hall-effect-probe-owv4n","title":"Fluke i1010 AC\/DC Current Clamp 1000A Hall Effect Probe","description":"\u003cp\u003e[shortdesc] Professional AC\/DC current clamp with Hall-effect sensor. Measures DC current up to 1000A and AC up to 600A. CAT III 600V safety rated with 1 mV\/A output.[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px; height: 411.524px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eFluke i1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eAC\/DC Current Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eHall sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003e1 A to 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eDC Current Range\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003e1 A to 1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eOutput Level\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003e1 mV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eDC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eSafety Rating\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eMaximum Conductor Diameter\u003c\/td\u003e\n\u003ctd style=\"height: 39.1927px;\"\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd style=\"height: 19.5964px;\"\u003e9 V, 60 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Current Range\u003c\/td\u003e\n\u003ctd\u003e600 A AC; 1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current Range\u003c\/td\u003e\n\u003ctd\u003e1 A to 600 A AC; 1 A to 1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Non-destructive Current\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLowest Measurable Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Accuracy\u003c\/td\u003e\n\u003ctd\u003e2% + 0.5 A (% reading + floorspec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable Frequency\u003c\/td\u003e\n\u003ctd\u003eDC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e1 mV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Adjustment\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Conductor Diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm; 2 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eShrouded banana plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\n\u003ch2\u003eMeasure High Currents Safely Without Breaking the Circuit\u003c\/h2\u003e\n\u003cp\u003eThe Fluke i1010 AC\/DC Current Clamp is designed for professionals who need precise, non-intrusive current measurements in demanding environments. Built with Hall-effect technology, this clamp extends the capabilities of Fluke multimeters, enabling accurate AC and DC current readings up to 1000A without interrupting the circuit. Its robust design and wide measurement range make it an essential diagnostic tool for electrical maintenance and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Current Measurement Range:\u003c\/strong\u003e Measures from 1A up to 1000A DC and 600A AC, making it suitable for both low and high current applications across industrial systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHall-Effect Sensor Technology:\u003c\/strong\u003e Ensures accurate AC and DC readings with a stable 1 mV\/A output for precise analysis and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Intrusive Testing:\u003c\/strong\u003e Allows current measurement without breaking the circuit, improving safety and minimizing downtime during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Works seamlessly with most Fluke digital multimeters, extending their measurement capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Jaw Design:\u003c\/strong\u003e Accommodates conductors up to 30 mm diameter, enabling access to cables in tight or hard-to-reach areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical maintenance and troubleshooting in industrial facilities\u003c\/li\u003e\n\u003cli\u003ePower distribution system diagnostics\u003c\/li\u003e\n\u003cli\u003eHVAC system current monitoring\u003c\/li\u003e\n\u003cli\u003eField service testing with Fluke multimeters\u003c\/li\u003e\n\u003cli\u003eInspection of high-current circuits without system shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e Hall sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current Range:\u003c\/strong\u003e 1A to 600A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current Range:\u003c\/strong\u003e 1A to 1000A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e 1000A non-destructive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 2% + 0.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e DC to 10 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 1 mV\/A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Conductor Diameter:\u003c\/strong\u003e 30 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Cable Length:\u003c\/strong\u003e 1.6 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpgrade Your Electrical Testing Precision Today\u003c\/h2\u003e\n\u003cp\u003eEnhance your measurement capabilities with the Fluke i1010 current clamp. \u003cstrong\u003eOrder today\u003c\/strong\u003e for reliable, high-accuracy current diagnostics.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49023698764032,"sku":"FLUKE-i1010-NEW","price":574.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-i1010_1_e5bbd7ee-867b-419a-98b5-baff1868773a.webp?v=1784296487"},{"product_id":"fluke-15b-digital-multimeter-cat-iii-600v-kwxgr","title":"FLUKE-15B+ Digital Multimeter CAT III 600V","description":"\u003cp\u003e[shortdesc] Professional digital multimeter featuring CAT III 600V safety rating, 1000V AC\/DC measurement, and 10A current testing. [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 15B+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eFLUKE-15B+-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4000 counts, updates 3\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement\u003c\/td\u003e\n\u003ctd\u003eAC\/DC up to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003eAC\/DC up to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003eUp to 40 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003eVoltage, Resistance, Continuity, Capacitance, Diode Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V, CAT II 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V (Terminal to Earth Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e2 AA batteries (NEDA 15A IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e500 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (HxWxL)\u003c\/td\u003e\n\u003ctd\u003e183 x 91 x 49.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e455 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 C to 40 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange: 4.000 V to 1000 V; Accuracy: plus\/minus(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange: 4.000 V to 1000 V; Accuracy: plus\/minus(0.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/DC Millivolts\u003c\/td\u003e\n\u003ctd\u003e400.0 mV range; Resolution: 0.1 mV; Accuracy: AC plus\/minus(3.0% + 3), DC plus\/minus(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400 ohm to 40 Mohm; Accuracy: plus\/minus(0.5% + 2) typical, plus\/minus(1.5% + 3) at 40 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e40.00 nF to 1000 uF; Accuracy: plus\/minus(2% + 5) to plus\/minus(5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e400.0 uA to 10 A; Accuracy: plus\/minus(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e400.0 uA to 10 A; Accuracy: plus\/minus(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e2.000 V range; Resolution: 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003eAudible continuity test with data hold function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eMore than 10 Mohm, Less than 100 pF (voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, IEC 61010-2-030, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eTest leads with caps; 2 AA batteries; User manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eTPAK Meter Hanging Kit; TL175 TwistGuard Test Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eReliable Electrical Testing with Trusted Fluke Precision\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 15B+ Digital Multimeter is engineered for professionals who demand accuracy, safety, and durability in everyday electrical diagnostics. Designed by Fluke, a global leader in test and measurement tools, this compact multimeter delivers precise readings across voltage, current, and resistance applications while maintaining rugged reliability in demanding environments. With CAT III 600V safety compliance and intuitive usability, it is ideal for field technicians and electrical professionals.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Voltage Measurement Capability:\u003c\/strong\u003e Accurately measure AC and DC voltage up to 1000V, supporting a wide range of electrical troubleshooting tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurement Functions:\u003c\/strong\u003e Includes voltage, resistance, continuity, capacitance, and diode testing for versatile diagnostics across electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10A Current Measurement:\u003c\/strong\u003e Supports AC\/DC current measurement up to 10A, enabling reliable analysis of circuits and load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety Design:\u003c\/strong\u003e CAT III 600V and CAT II 1000V ratings ensure safe operation in industrial and commercial electrical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Backlit Display:\u003c\/strong\u003e Features a 50% larger LCD with bright white backlight for clear visibility in low-light conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical maintenance and troubleshooting in commercial buildings\u003c\/li\u003e\n\u003cli\u003eField service diagnostics for industrial equipment\u003c\/li\u003e\n\u003cli\u003eTesting circuits, wiring, and power distribution systems\u003c\/li\u003e\n\u003cli\u003eFacility maintenance and HVAC applications\u003c\/li\u003e\n\u003cli\u003eProfessional electricians and technical service teams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Measurement:\u003c\/strong\u003e AC\/DC up to 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement:\u003c\/strong\u003e AC\/DC up to 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Range:\u003c\/strong\u003e Up to 40 Mohm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Range:\u003c\/strong\u003e Up to 1000 uF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 4000-count LCD, 3 updates\/sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 600V, CAT II 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e 2 x AA with 500 hours minimum life\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 183 x 91 x 49.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 455 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpgrade Your Measurement Accuracy Today\u003c\/h2\u003e\n\u003cp\u003eEquip your toolkit with Fluke reliability and precision. \u003cstrong\u003eOrder today\u003c\/strong\u003e and measure with confidence.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49023698829568,"sku":"FLUKE-15B+-R-NEW","price":138.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-15B_-R_1_9e5867ee-a722-4633-b4c7-673078977f7a.webp?v=1784296489"},{"product_id":"fluke-87-ve2-kit-industrial-combo-kit-with-digital-multimeter-1znb7","title":"FLUKE-87-V\/E2-KIT Industrial Combo Kit with Digital Multimeter","description":"\u003cp\u003e[shortdesc] True RMS industrial multimeter kit, 1000V AC\/DC, 20A current (short duration), built-in thermometer, and CAT IV safety rating. Includes magnetic hanger and premium accessories. [\/shortdesc]\u003c\/p\u003e\n\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 87V\/E2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Digital Multimeter Combo Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6,000 counts (3-3\/4 digit) or 20,000 counts (4-1\/2 digit); analog bar graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003eYes (AC Voltage and Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eUp to 50 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eUp to 200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-200 °C to 1090 °C (Meter capability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eUp to 99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e9V Battery (Included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~400 hours typical (Alkaline, without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e201 x 98 x 52 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e624 g (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAssembled in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1); Max Resolution 10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 2) True RMS; Bandwidth 20 kHz (with low pass filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2); Max Resolution 0.01 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2) True RMS; Max Resolution 0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1); Max Resolution 0.1 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2); Max Resolution 0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1); Max Resolution 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% per kHz + 0.1%); Max Resolution 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80BK-A Probe Range\u003c\/td\u003e\n\u003ctd\u003e-40.0 °C to 260 °C (-40.0 °F to 500 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductance\u003c\/td\u003e\n\u003ctd\u003eMax 60.00 nS; Accuracy ±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e3 V Range; 1 mV Resolution; ±(2% + 1) Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Capture\u003c\/td\u003e\n\u003ctd\u003eCaptures intermittent signals as short as 250 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0%–90% (0 °C–35 °C); 0%–70% (35 °C–55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\/Vibration\u003c\/td\u003e\n\u003ctd\u003e1 Meter drop (IEC 61010-1); MIL-PRF-28800 Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certifications\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, TÜV, VDE listed; EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Items\u003c\/td\u003e\n\u003ctd\u003eFluke 87V Industrial Multimeter, TL224 SureGrip Insulated Test Leads, AC220 SureGrip Alligator Clips, TL238 SureGrip Test Probes, ToolPak Magnetic Meter Hanging Kit, 80BK-A DMM Temperature Probe, C35 Soft Carrying Case, 9V Battery (installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\n\u003ch2\u003ePrecision Measurement Power for Industrial Environments\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 87V\/E2 Industrial Electrician Combo Kit is engineered for professionals who demand accuracy, reliability, and safety in high-energy environments. Built around the industry-leading Fluke 87V digital multimeter, this kit delivers advanced diagnostic capabilities and essential accessories to streamline troubleshooting and improve productivity in complex electrical systems.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Accuracy:\u003c\/strong\u003e Ensures precise AC voltage and current measurements on non-linear signals, critical for VFDs and industrial loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measurement Capability:\u003c\/strong\u003e Measures up to 1000V AC\/DC and 10A current with high resolution, enabling accurate diagnostics across diverse applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Troubleshooting Tools:\u003c\/strong\u003e Peak capture, Min\/Max\/Avg recording, and glitch detection down to 250 µs help identify intermittent signals and spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Temperature Measurement:\u003c\/strong\u003e Includes a dedicated thermocouple probe, making it ideal for monitoring electrical components and motor temperatures without a separate thermometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Accessory Kit:\u003c\/strong\u003e Features fully insulated 3 mm exposed metal test probes, magnetic hanging strap for hands-free use, and a durable soft carrying case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial electrical troubleshooting and plant automation maintenance\u003c\/li\u003e\n\u003cli\u003eVSD\/VFD output side measurements at drive or motor terminals\u003c\/li\u003e\n\u003cli\u003ePower distribution analysis and electromechanical equipment repair\u003c\/li\u003e\n\u003cli\u003eField service technicians requiring high-resolution (20,000 count) data\u003c\/li\u003e\n\u003cli\u003eChecking power quality and capturing fast 250 µs glitches\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e Up to 1000V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 10A (20A for 30 seconds max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Accuracy:\u003c\/strong\u003e 0.05% DC accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000 counts or 20,000 counts in high-resolution mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -200 °C to 1090 °C (Meter); -40 °C to 260 °C (Probe)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 10,000 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Up to 200 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 1000V, CAT IV 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20 °C to +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Approx. 400 hours (Alkaline)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEquip Your Toolkit with Industry-Leading Precision\u003c\/h2\u003e\n\u003cp\u003eBoost accuracy and efficiency with the trusted Fluke 87V\/E2 kit. \u003cstrong\u003eOrder today\u003c\/strong\u003e and upgrade your measurement capabilities with the world’s most trusted industrial multimeter.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49023715770624,"sku":"FLUKE-87-V\/E2-KIT-NEW","price":790.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-87-V-E2-KIT_1_dc992823-a3c8-4a9a-98df-08d9e949a000.webp?v=1784296504"},{"product_id":"fluke-1577-insulation-multimeter-oenw1","title":"FLUKE-1577 Insulation Multimeter","description":"\u003cp\u003e[shortdesc]  Insulation tester and True RMS multimeter, 500 V and 1000 V insulation test voltages, up to 600 MΩ insulation resistance, CAT IV 600 V safety rating, handheld diagnostic tool [\/shortdesc]\u003c\/p\u003e\n\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 1577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInsulation Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.1 MOhm to 600 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/DC Current Range\u003c\/td\u003e\n\u003ctd\u003eUp to 400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0.1 Ohm to 50 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eFour AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eMeter use: 1000 hours; at least 1000 insulation tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e203 x 100 x 50 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e624 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 C to +55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 C to +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003eMaximum voltage 1000 V; Accuracy (0.2% + 2); Maximum resolution 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003eMaximum voltage 1000 V; Accuracy (2% + 3); Maximum resolution 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003eMaximum 400 mA; Accuracy (1.0% + 2); Maximum resolution 0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003eMaximum 400 mA; Accuracy (2.0% + 2); Maximum resolution 0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eMaximum resistance 50 MOhm; Accuracy (1.2% + 2); Maximum resolution 0.1 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Current\u003c\/td\u003e\n\u003ctd\u003eMinimum test current @ 1 kOhm\/V: 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistance per Test Voltage\u003c\/td\u003e\n\u003ctd\u003e600 MOhm (1000 V test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution per Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V: 0.01 MOhm; 100 V: 0.01 MOhm; 250 V: 0.1 MOhm; 500 V: 0.1 MOhm; 1000 V: 0.1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy per Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V (3% + 5); 100 V (3% + 5); 250 V (1.5% + 5); 500 V (2.0% + 5); 1000 V (2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0-95% (10 C to 30 C); 0-75% (30 C to 40 C); 0-40% (40 C to 55 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 Pollution Degree 2; IEC 61010-2-033: CAT IV 600V\/CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eRemote probe; Test leads; Alligator clips; Hard case; Four AA alkaline batteries; Quick reference guide; CD ROM with manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eFluke TPAK magnetic hanging system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\n\u003ch2\u003eDual-Function Electrical Testing for Advanced Diagnostics\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 1577 Insulation Multimeter combines a professional insulation resistance tester with a full-featured True RMS digital multimeter in a single, compact handheld instrument. Designed for electricians and maintenance professionals, this versatile device enables both troubleshooting and preventative maintenance across motors, cables, generators, and switchgear.\u003c\/p\u003e\n\u003cp\u003eWith insulation test voltages of 500 V and 1000 V and resistance measurement up to 600 MOhm, the Fluke 1577 provides accurate diagnostics while maintaining high safety standards. Its rugged design, large backlit display, and live circuit detection make it an essential tool for demanding industrial environments.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Tools in One:\u003c\/strong\u003e Integrates a digital insulation tester and a True RMS multimeter, eliminating the need for multiple instruments and improving efficiency.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eHigh-Voltage Insulation Testing:\u003c\/strong\u003e Provides selectable test voltages of 500 V and 1000 V with measurement capabilities from 0.1 MOhm to 600 MOhm.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Measurement Accuracy:\u003c\/strong\u003e Ensures precise AC voltage and current readings even in noisy electrical environments with non-linear signals.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eAdvanced User Protection:\u003c\/strong\u003e Built-in live circuit detection prevents insulation tests if voltage greater than 30 V is detected, increasing field safety.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eField-Ready Design:\u003c\/strong\u003e Features a rugged utility hard case, auto power-off to save battery, and compatibility with the optional Fluke TPAK magnetic hanging system for hands-free use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial motor and generator insulation diagnostics\u003c\/li\u003e\n\u003cli\u003eElectrical installation and cable troubleshooting\u003c\/li\u003e\n\u003cli\u003ePreventative maintenance of power distribution systems\u003c\/li\u003e\n\u003cli\u003eSwitchgear testing and electrical safety inspections\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Test Voltages:\u003c\/strong\u003e 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance Range:\u003c\/strong\u003e 0.1 MOhm to 600 MOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage Measurement:\u003c\/strong\u003e Up to 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Up to 400 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Measurement:\u003c\/strong\u003e 0.1 Ohm to 50 MOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20 C to +55 C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 203 x 100 x 50 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 624 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eUpgrade Your Electrical Testing Toolkit Today\u003c\/h2\u003e\n\u003cp\u003eChoose the Fluke 1577 insulation multimeter for dependable diagnostics and professional-grade electrical testing. \u003cstrong\u003eOrder today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024176521472,"sku":"FLUKE-1577-NEW","price":1115.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-1577_b05bb35a-06a2-4639-8ecb-c4a77a7d887a.webp?v=1784297986"},{"product_id":"fluke-a3000fc-wireless-ac-current-clamp-module-bq6gy","title":"FLUKE-A3000FC Wireless AC Current Clamp Module","description":"\u003cp\u003e[shortdesc] True-RMS AC clamp module, 0.5 A to 400 A range, wireless 2.4 GHz communication, logs 65,000 readings, and captures inrush current. [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke a3000 FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eWireless AC Current Clamp Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS AC Current Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Function\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inrush Display\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Function\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eRecord up to 65,000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Communications\u003c\/td\u003e\n\u003ctd\u003e2.4 GHZ ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Communication Range (Open Air)\u003c\/td\u003e\n\u003ctd\u003eUp to 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Communication Range (Sheetrock Wall)\u003c\/td\u003e\n\u003ctd\u003eUp to 6.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Communication Range (Concrete Wall \/ Steel Enclosure)\u003c\/td\u003e\n\u003ctd\u003eUp to 3.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Master Units\u003c\/td\u003e\n\u003ctd\u003eFluke 3000 FC DMM; Fluke Ti200\/300\/400 Infrared Camera; PC via optional pc3000 FC Adapter; Fluke Connect Mobile app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot Compatible With\u003c\/td\u003e\n\u003ctd\u003eFluke CNX test tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e34 mm (1.33 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD w\/backlight, 3.5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Rate \/ Interval\u003c\/td\u003e\n\u003ctd\u003e1 sec minimum (adjustable by PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e2 AA, NEDA 15 A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 C to +50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 C to +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e90% at 35 C; 75% at 40 C; 45% at 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude (Operating)\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude (Storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) Rating\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg (8 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (10 Hz to 100 Hz)\u003c\/td\u003e\n\u003ctd\u003e2% +\/- 5 digits (at 400.0 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (100 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5% +\/- 5 digits (at 400.0 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush\u003c\/td\u003e\n\u003ctd\u003eMax displayed reading 999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50 Hz \/ 60 Hz)\u003c\/td\u003e\n\u003ctd\u003e3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Rate \/ Interval\u003c\/td\u003e\n\u003ctd\u003e1 sec minimum (adjustable by PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x (specified accuracy) \/ C (\u0026lt; 18 C or \u0026gt; 28 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, 600 V CAT III, 3rd edition, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS AC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003epc3000 FC Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eWireless True-RMS Current Measurement with Safer Remote Monitoring\u003c\/h2\u003e\n\u003cp\u003eThe Fluke a3000 FC Wireless AC Current Clamp Module delivers precise True-RMS current measurements up to 400 A while allowing technicians to monitor readings remotely through the Fluke Connect system. Designed for industrial electricians and maintenance professionals, it enhances safety by enabling measurement collection outside hazardous panels. With wireless data transfer, logging, and inrush capture, it streamlines troubleshooting and preventive maintenance workflows.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS AC Measurement:\u003c\/strong\u003e Accurately measures non-linear loads from 0.5 A to 400 A, ensuring reliable readings in real-world industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Fluke Connect Integration:\u003c\/strong\u003e Transmits live measurements via 2.4 GHz ISM band to compatible Fluke Connect devices, PCs, and mobile apps for remote visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Logging Capability:\u003c\/strong\u003e Records and stores up to 65,000 time-stamped readings with adjustable intervals starting at 1 second for long-term trend analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Function:\u003c\/strong\u003e Captures startup surge currents up to 999.9 A to diagnose motor and transformer performance issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandalone or System Operation:\u003c\/strong\u003e Operates independently as a clamp meter or as part of a scalable Fluke Connect wireless test system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase panel diagnostics with remote viewing\u003c\/li\u003e\n\u003cli\u003eMotor startup and inrush current analysis\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance logging and load trending\u003c\/li\u003e\n\u003cli\u003eElectrical troubleshooting in industrial facilities\u003c\/li\u003e\n\u003cli\u003eArc flash risk reduction environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 0.5 A to 400.0 A AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 2% +\/- 5 digits (10 Hz to 100 Hz), 2.5% +\/- 5 digits (100 Hz to 500 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush:\u003c\/strong\u003e Max displayed reading 999.9 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Up to 65,000 readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Frequency:\u003c\/strong\u003e 2.4 GHz ISM band\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Range:\u003c\/strong\u003e Up to 20 m unobstructed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 34 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e 2 AA, up to 400 hours operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eImprove Safety and Speed in Electrical Diagnostics\u003c\/h2\u003e\n\u003cp\u003eReduce exposure to live panels while capturing precise AC current data with the Fluke a3000 FC. Designed for connected maintenance environments. Order today to upgrade your electrical troubleshooting workflow.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024188612864,"sku":"FLUKE-A3000FC-NEW","price":330.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-A3000FC_1_234d6fa5-59d3-420d-b5f2-8f92be80a5e2.webp?v=1784298013"},{"product_id":"fluke-289-fvf-true-rms-industrial-logging-multimeter-with-trendcapture-97ubs","title":"FLUKE-289-FVF True-RMS Industrial Logging Multimeter with TrendCapture","description":"\u003cp\u003e[shortdesc] True-RMS industrial logging DMM kit, 1000 V AC\/DC measurement, 10 A current range, 50,000-count 1\/4 VGA display, 100 kHz bandwidth, TrendCapture and FlukeView Forms software included. [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 289\/FVF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTrue-rms Industrial Logging Multimeter with TrendCapture and FlukeView Forms software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Type\u003c\/td\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd\u003eAC\/DC voltage, AC\/DC current, resistance, continuity, capacitance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e50,000-count, 1\/4 VGA dot matrix display with white backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue-rms AC Bandwidth\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current Range\u003c\/td\u003e\n\u003ctd\u003e500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Range\u003c\/td\u003e\n\u003ctd\u003e500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e1.000 nF, 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) (excluding probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage to Earth Ground\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eSix AA alkaline batteries (NEDA 15A IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e100 hours minimum; 200 hours in logging mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e22.2 × 10.2 × 6 cm (8.75 × 4.03 × 2.38 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e870.9 g (28 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges 50.000 mV to 1000.0 V; basic accuracy ±0.025%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges 50.000 mV to 1000.0 V; basic accuracy ±0.4% (true-rms).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges 500.00 µA to 10.000 A; basic accuracy ±0.15%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges 500.00 µA to 10.000 A; basic accuracy ±0.7% (true-rms).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd\u003eRange -200.0°C to 1350.0°C (-328.0°F to 2462.0°F), excluding probe; accuracy ±1.0%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges 50.000 Ω to 500.0 MΩ; basic accuracy ±0.05%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges 1.000 nF to 100 mF; basic accuracy ±1.0%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges 99.999 Hz to 999.99 kHz; basic accuracy 0.005%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductance\u003c\/td\u003e\n\u003ctd\u003e50.00 nS.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003eContinuity beeper with relative mode to remove test lead resistance from low ohms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging \/ Recording\u003c\/td\u003e\n\u003ctd\u003eOn-board logging with up to 15,000 recorded events; interval and event logging; log to PC via isolated optical interface; real-time clock for time-stamped readings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrendCapture \/ Display\u003c\/td\u003e\n\u003ctd\u003eTrendCapture graphical display of logged sessions with up to 14x zoom; multiple on-screen displays on large 50,000-count 1\/4 VGA white-backlit screen.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilters \u0026amp; Measurement Modes\u003c\/td\u003e\n\u003ctd\u003eSelectable AC filter (smoothing mode); low pass filter for adjustable-speed motor drives; LoZ low-impedance volts function for ghost voltage elimination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Statistics\u003c\/td\u003e\n\u003ctd\u003eMin\/Max\/Avg recording, duty cycle, pulse width, peak capture to 250 µs, auto\/touch hold, reading memory.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0-90% (0-37°C); 0-65% (37°C-45°C); 0-45% (45°C-55°C).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN61326-1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock\u003c\/td\u003e\n\u003ctd\u003eRandom vibration per MIL-PRF-28800F Class 2; 1 m drop per IEC\/EN 61010-1 2nd Edition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003e289 Multimeter; FlukeView Forms Software with cable; AC175 Alligator Clips; 80BK-A Thermocouple Probe; TL71 Silicon Test Lead Set; TPAK Magnetic Hanging Kit; C280 Soft Case; Amp Jack Plug Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eFVF-SC2 FlukeView Forms Software with Cable; TLK289 Industrial Test Lead Set; i400 AC Current Clamp; i410 AC\/DC Current Clamp; 80BK Integrated DMM Temperature Probe; TPAK Magnetic Hanging Kit; C280 Soft Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eLog Critical Measurements and Diagnose Faults Faster with the Fluke 289\/FVF\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 289\/FVF True-RMS Industrial Logging Multimeter kit combines the high-performance Fluke 289 handheld meter with FlukeView Forms software and essential accessories. This powerful tool is designed to help engineers and technicians capture elusive, intermittent electrical events, visualize data trends directly on the meter or PC, and document results professionally for reliable predictive and preventive maintenance in demanding electrical and industrial environments.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Logging with TrendCapture:\u003c\/strong\u003e Log up to 15,000 recorded events (readings) and review them graphically on the large display using TrendCapture to quickly locate intermittent problems and anomalies without needing a PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Coverage:\u003c\/strong\u003e Perform true-RMS measurements up to\u003cstrong\u003e \u003c\/strong\u003e1000 V AC\/DC, 10 A current (20 A for 30 seconds), resistance to 500 MΩ, capacitance to 100 mF, and frequency up to 999.99 kHz for comprehensive plant, lab, and field work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Troubleshooting Tools:\u003c\/strong\u003e Features include a\u003cstrong\u003e \u003c\/strong\u003eLow-Pass filter for accurate voltage\/frequency measurements on adjustable-speed drives, LoZ low-impedance volts mode to eliminate ghost voltages, and Min\/Max\/Avg recording with 250 µs peak capture to expose fast transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Visibility Display:\u003c\/strong\u003e The large\u003cstrong\u003e \u003c\/strong\u003e50,000-count 1\/4 VGA dot matrix display with white backlight clearly shows multiple on-screen readings and trend graphs, enhancing visibility in low-light environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProductive Combo Kit:\u003c\/strong\u003e Includes the 289 meter, FlukeView Forms software and cable, TL71 silicon test leads, AC175 alligator clips, 80BK-A thermocouple probe, TPAK magnetic hanging kit, C280 soft case, and amp jack plug set.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation and Control Panels:\u003c\/strong\u003e Use the logging function and TrendCapture to verify process stability, detect signal drift, and diagnose complex electrical issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution and Facility Maintenance:\u003c\/strong\u003e Critical for diagnosing overloads, harmonics, and intermittent voltage\/current events on power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Service on Electro-Mechanical Equipment:\u003c\/strong\u003e The rugged design and TPAK Magnetic Hanging Kit improve safety and provide hands-free operation for working on motors and other machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC\/AC Voltage Range:\u003c\/strong\u003e 50 mV to 1000 V, basic DC accuracy ±0.025%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC\/AC Current Range:\u003c\/strong\u003e 500 µA to 10 A (with 20 A for 30 seconds capability).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Range:\u003c\/strong\u003e 50 Ω to 500 MΩ. Features a 50 Ω range with\u003cstrong\u003e \u003c\/strong\u003e1 mΩ resolution and 10 mA source current for motor winding and contact resistance measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Range:\u003c\/strong\u003e 1 nF to 100 mF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 99.999 Hz to 999.99 kHz, supported by a 100 kHz true-RMS AC bandwidth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range (Excluding Probe):\u003c\/strong\u003e -200.0°C to 1350.0°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogging Memory:\u003c\/strong\u003e Up to 15,000 recorded events with adjustable recording and auto hold thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and Size:\u003c\/strong\u003e Operates on six AA alkaline batteries, with a size of approx. 22.2 cm x 10.2 cm x 6 cm, and a weight of 870.9 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit SKU:\u003c\/strong\u003e \u003cstrong\u003eFLUKE-289\/FVF\u003c\/strong\u003e True-RMS Industrial Logging DMM with FlukeView Forms combo.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDeploy Trusted Fluke Logging Capability Across Sites\u003c\/h2\u003e\n\u003cp\u003eEquip your maintenance team with the\u003cstrong\u003e \u003c\/strong\u003eFluke 289\/FVF kit to capture crucial electrical data, visualize performance trends, and confidently support evidence-based maintenance decisions. Order the Fluke 289\/FVF Industrial Logging Multimeter kit today.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024242581760,"sku":"FLUKE-289-FVF-NEW","price":1122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/1935_1_b84a36d3-95bc-4f78-b9ee-5b2d45fa8343.jpg?v=1784298289"},{"product_id":"fluke-279-fc-iflex-true-rms-thermal-multimeter-bi9vt","title":"FLUKE-279-FC-iflex True RMS Thermal Multimeter","description":"\u003cp\u003e[shortdesc] True-RMS thermal multimeter, built-in IR camera, iFlex probe to 2500 A AC, wireless Fluke Connect, CAT III 1000 V \/ CAT IV 600 V [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 279 FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTrue-rms Thermal Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Imager\u003c\/td\u003e\n\u003ctd\u003eBuilt-in infrared camera, 102 × 77 resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 200 °C (14 °F to 392 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Sensitivity (NETD)\u003c\/td\u003e\n\u003ctd\u003e≤ 200 mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e36° (w) × 27° (h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance to Spot\u003c\/td\u003e\n\u003ctd\u003e162:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3.5 in (8.9 cm) color LCD; 6000 counts volts, amps, ohms; 10000 counts frequency; 1000 counts capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd\u003e15 functions: AC voltage with low-pass filter, DC voltage, resistance, continuity, capacitance, diode test, min\/max\/avg, AC current (with iFlex), frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e600.0 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e600.0 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω to 50.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e1000 nF to 9999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Range\u003c\/td\u003e\n\u003ctd\u003e999.9 A; up to 2500 A AC with iFlex flexible current probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz and 999.9 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage to Earth\u003c\/td\u003e\n\u003ctd\u003e1000 V between any terminal and earth ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eFluke BP500 lithium ion battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e10 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Communications\u003c\/td\u003e\n\u003ctd\u003e2.4 GHz ISM band; up to 20 m open air, up to 6.5 m through sheetrock wall, up to 3.5 m through concrete wall or steel electrical enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 50 °C (14 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 60 °C (-4 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0% to 90% (0 °C to 35 °C); 0% to 75% (35 °C to 40 °C); 0% to 45% (40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H × W × L)\u003c\/td\u003e\n\u003ctd\u003e5.7 cm × 9.4 cm × 21.6 cm (2.3 in × 3.7 in × 8.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.80 kg (1.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCSA, FCC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eRanges 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V; Resolution 0.1 mV to 1 V; Accuracy 45 Hz to 65 Hz: ±(1.0% + 3); 65 Hz to 200 Hz: ±(4.0% + 3); 200 Hz to 500 Hz: ±(15% + 3); crest factor ≤ 3 at full scale up to 500 V; full time low pass filter; do not exceed 107 V-Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC mV\u003c\/td\u003e\n\u003ctd\u003eRange 600.0 mV; Resolution 0.1 mV; Accuracy 45 Hz to 500 Hz: ±(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eRanges 6.000 V, 60.00 V, 600.0 V, 1000 V; Resolution 0.001 V to 1 V; Accuracy 6 V to 600 V: ±(0.09% + 2); 1000 V: ±(0.15% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC mV\u003c\/td\u003e\n\u003ctd\u003eRange 600.0 mV; Resolution 0.1 mV; Accuracy ±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRanges 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ, 50.00 MΩ; Resolution 0.1 Ω to 0.01 MΩ; Accuracy 600 Ω: ±(0.5% + 2); 6 kΩ to 600 kΩ: ±(0.5% + 1); 50 MΩ: ±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003eRange 600 Ω; Resolution 1 Ω; Beeper on at \u0026lt; 25 Ω; detects opens or shorts of 600 µs or longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003eRange 2.000 V; Resolution 0.001 V; Accuracy ±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRanges 1000 nF, 10.00 µF, 100.0 µF, 9999 µF; Resolution 1 nF to 1 µF; Accuracy 1000 nF to 100 µF: ±(1.2% + 2); 9999 µF: ±10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (with iFlex)\u003c\/td\u003e\n\u003ctd\u003eRanges 999.9 A, 2500 A; Resolution 0.1 A and 1 A; Accuracy 45 Hz to 500 Hz: ±(3.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eRanges 99.99 Hz and 999.9 Hz; Resolution 0.01 Hz and 0.1 Hz; Accuracy ±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Characteristics\u003c\/td\u003e\n\u003ctd\u003eAC, DC, mV inputs: nominal input impedance \u0026gt; 10 MΩ, \u0026lt; 100 pF; common mode rejection ratio \u0026gt; 60 dB DC to 60 Hz (AC volts), \u0026gt; 120 dB at DC, 50 Hz or 60 Hz (DC volts and mV); normal mode rejection \u0026gt; 60 dB at 50 Hz or 60 Hz; overload protection 1100 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance \/ Capacitance Input\u003c\/td\u003e\n\u003ctd\u003eOpen circuit test voltage \u0026lt; 2.7 V DC; full scale voltage to 6 MΩ \u0026lt; 0.7 V DC; full scale voltage 50 MΩ \u0026lt; 0.9 V DC; typical short circuit current \u0026lt; 350 mA; overload protection 1100 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity \/ Diode Input\u003c\/td\u003e\n\u003ctd\u003eOpen circuit test voltage \u0026lt; 2.7 V DC; full scale voltage 2.000 V DC; typical short circuit current \u0026lt; 1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMIN\/MAX Recording\u003c\/td\u003e\n\u003ctd\u003eAC functions: captures changes \u0026gt; 900 ms, 40 counts; DC functions: captures changes \u0026gt; 350 ms, 12 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Camera Temperature\u003c\/td\u003e\n\u003ctd\u003eRange -10 °C to 200 °C; resolution 0.1 °C; centerpoint temperature measurement; accuracy ±5 °C or ±5%, whichever is greater, at 25 °C ambient; emissivity 0.95 fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Camera Optics\u003c\/td\u003e\n\u003ctd\u003eResolution 102 × 77; image capture frequency 8 Hz; detector type uncooled vanadium oxide; infrared spectral band 7.5 µm to 14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Capture \/ Storage\u003c\/td\u003e\n\u003ctd\u003eImage review before save; internal memory stores up to 100 images; image transfer via Fluke Connect or SmartView software; file format .is2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Update Rate\u003c\/td\u003e\n\u003ctd\u003e4 readings per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.1 × specified accuracy per °C for temperatures below 18 °C or above 28 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Conditions\u003c\/td\u003e\n\u003ctd\u003eOperating temperature -10 °C to 50 °C; storage temperature -20 °C to 60 °C; relative humidity 0% to 90% (0 °C to 35 °C), 0% to 75% (35 °C to 40 °C), 0% to 45% (40 °C to 50 °C); operating altitude 2000 m; storage altitude 12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety \/ Compliance\u003c\/td\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground 1000 V; measurement category CAT III 1000 V, CAT IV 600 V; certifications CSA, FCC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (279 FC\/iFlex)\u003c\/td\u003e\n\u003ctd\u003eFluke 279 FC True-rms Thermal Multimeter; 18 in (45.72 cm) iFlex flexible current probe; TL175 test leads; rechargeable lithium ion battery; battery charger; soft carrying case; hanging strap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (FLUKE-279FC I\/B)\u003c\/td\u003e\n\u003ctd\u003eFluke 279 FC True-rms Thermal Multimeter; 18 in (45.72 cm) iFlex flexible current probe; TL175 test leads; two rechargeable lithium ion batteries; one charger; soft carrying case; hanging strap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Current Probes\u003c\/td\u003e\n\u003ctd\u003eFluke i2500-10 iFlex Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Power\u003c\/td\u003e\n\u003ctd\u003eFluke BC500 AC Power Charger; Fluke BP500 Lithium Ion Battery 3000 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Cases\u003c\/td\u003e\n\u003ctd\u003eFluke C280 Carrying Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eSee Hot Spots And Electrical Values In One Trusted Fluke Instrument\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 279 FC iFlex True-RMS Thermal Multimeter combines a full digital multimeter with a built-in thermal imager so technicians can find, verify, and document electrical problems faster and safer. Scan for hot spots with the 102 × 77 IR camera, capture load measurements up to 2500 A AC using the included iFlex probe, and send results wirelessly through Fluke Connect to reduce time in front of live panels and improve troubleshooting efficiency.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated thermal imaging:\u003c\/strong\u003e Built-in 102 × 77 infrared camera quickly reveals hot connections, overloaded components, and insulation issues so you can see exactly where to measure from a safe distance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-function True-RMS DMM:\u003c\/strong\u003e Includes 15 measurement functions such as AC\/DC voltage, resistance, continuity, capacitance, frequency, diode test, and min\/max\/avg, all housed in a safety-rated CAT IV 600 V \/ CAT III 1000 V instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex flexible current probe:\u003c\/strong\u003e The included 18 in iFlex probe lets you work in tight, hard-to-reach spaces, measuring up to 2500 A AC without breaking the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Fluke Connect:\u003c\/strong\u003e Transmit readings and images wirelessly to a smartphone up to 20 feet (6.1 m) away (unobstructed), compare against historical data, and create reports without returning to the office.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged all-day tool:\u003c\/strong\u003e Features a large 3.5 in color LCD, 6000-count DMM display, and a rechargeable lithium-ion battery that allows for 10+ hours of operation under normal conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial and commercial electrical maintenance teams diagnosing overloaded circuits, breakers, and feeders.\u003c\/li\u003e\n\u003cli\u003ePanel builders and switchgear technicians verifying terminations, bus bars, and control wiring under load.\u003c\/li\u003e\n\u003cli\u003eHVAC and facility engineers checking motors, drives, contactors, and distribution boards for early failure signs.\u003c\/li\u003e\n\u003cli\u003eField service engineers supporting remote plants who need to capture images and readings for offsite review.\u003c\/li\u003e\n\u003cli\u003eElectrical safety and reliability programs that require documented thermal and electrical inspection data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement functions:\u003c\/strong\u003e AC\/DC voltage, AC current with iFlex, resistance, continuity, capacitance, frequency, diode test, min\/max\/avg, True-RMS (total 15 functions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC voltage range:\u003c\/strong\u003e 600.0 mV to 1000 V, with full-time low-pass filter for variable-speed drive signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC voltage range:\u003c\/strong\u003e 600.0 mV to 1000 V with up to 0.09% basic accuracy on main ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC current range:\u003c\/strong\u003e 999.9 A direct and up to 2500 A AC using the included iFlex flexible current probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance and continuity:\u003c\/strong\u003e Up to 50 MΩ resistance with audible continuity beeper below 25 Ω.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance range:\u003c\/strong\u003e Up to 9999 µF for testing motors, filters, and control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared camera:\u003c\/strong\u003e -10 °C to 200 °C temperature range, 0.1 °C resolution, and ≤ 200 mK sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 3.5 in (8.9 cm) color LCD with 6000-count DMM and 10000-count frequency display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety rating:\u003c\/strong\u003e CAT III 1000 V, CAT IV 600 V for work on distribution panels and feeders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and dimensions:\u003c\/strong\u003e Fluke BP500 rechargeable lithium-ion battery (10+ hours life), approx. 5.7 × 9.4 × 21.6 cm and 0.80 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpgrade Your Thermal And Electrical Troubleshooting In One Step\u003c\/h2\u003e\n\u003cp\u003eEquip your team with the \u003cstrong\u003eFLUKE-279-FC-iFlex\u003c\/strong\u003e to capture both thermal images and precise electrical measurements in a single trip and \u003cstrong\u003eorder today\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024242647296,"sku":"FLUKE-279-FC-iflex-NEW","price":1452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/279fc-iflex_40663496-85b4-4f49-9ae8-aa30d7c493cf.webp?v=1784298290"},{"product_id":"fluke-tl71-premium-test-lead-set-mwv2i","title":"Fluke TL71 Premium Test Lead Set","description":"\u003cp\u003e[shortdesc] 1.2 m length, 4 mm shrouded banana, 2 mm probe tip, silicone insulation, CAT III 1000 V CAT IV 600 V, 10 A max [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke TL71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePremium Test Lead Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Length\u003c\/td\u003e\n\u003ctd\u003e1.2 m (4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eStandard 4 mm (0.16 in) shrouded banana\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory Rating\u003c\/td\u003e\n\u003ctd\u003eCAT II 1000 V; with protective caps: CAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e10 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to 55 °C (−4 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (6,562 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Insulation\u003c\/td\u003e\n\u003ctd\u003eSilicone-insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\/Lead Style\u003c\/td\u003e\n\u003ctd\u003eComfort grip probes; right-angle test leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWearGuard™ Indicator\u003c\/td\u003e\n\u003ctd\u003eYes (shows contrasting color when worn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eWorks with instruments that accept standard 4 mm shrouded banana connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eOne pair: red \u0026amp; black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Length \/ Tip\u003c\/td\u003e\n\u003ctd\u003e1.2 m (4 ft); 2 mm probe tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Size\u003c\/td\u003e\n\u003ctd\u003e4 mm (0.16 in) shrouded banana\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Categories\u003c\/td\u003e\n\u003ctd\u003eCAT II 1000 V, 10 A; with protective caps: CAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e−20 °C to 55 °C (−4 °F to 131 °F); up to 90% RH; altitude 2000 m (6,562 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eSilicone-insulated leads for superior cold-flexibility and high-temperature resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWear Indication\u003c\/td\u003e\n\u003ctd\u003eWearGuard™ exposes contrasting color when lead insulation is damaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Note\u003c\/td\u003e\n\u003ctd\u003eRecommended for µV measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eOne pair (red, black) comfort grip probes with silicone-insulated, right-angle test leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003ePremium Test Leads Built for Safe, Accurate Measurements\u003c\/h2\u003e\n\u003cp\u003eThe Fluke TL71 pairs comfort-grip probes with flexible, silicone-insulated right-angle test leads to deliver reliable contact and safety in demanding environments. Rated up to CAT III 1000 V and CAT IV 600 V with protective caps, the TL71 helps technicians measure confidently while the WearGuard™ indicator makes insulation damage easy to spot.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWearGuard™ indicator:\u003c\/strong\u003e Contrasting color reveals insulation wear so you can replace leads before a safety risk develops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilicone-insulated leads:\u003c\/strong\u003e Superior flexibility in cold conditions and resistance to high temperatures for year-round field use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh safety ratings:\u003c\/strong\u003e Base rating of \u003cstrong\u003eCAT II 1000 V, 10 A\u003c\/strong\u003e; reaches \u003cstrong\u003eCAT III 1000 V\u003c\/strong\u003e and \u003cstrong\u003eCAT IV 600 V\u003c\/strong\u003e when protective caps are used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRight-angle connectors:\u003c\/strong\u003e Reduce strain at the meter and improve lead routing in tight panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision probe tips:\u003c\/strong\u003e \u003cstrong\u003e2 mm\u003c\/strong\u003e tips provide secure contact for stable, repeatable readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eField service and HVAC diagnostics requiring flexible, cold-resistant leads.\u003c\/li\u003e\n\u003cli\u003eIndustrial maintenance where CAT III\/CAT IV environments are common.\u003c\/li\u003e\n\u003cli\u003eElectronics troubleshooting and microvolt measurements (Recommended for µV measurements).\u003c\/li\u003e\n\u003cli\u003eGeneral DMM work with instruments accepting 4 mm shrouded banana connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead length:\u003c\/strong\u003e 1.2 m (4 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe tip:\u003c\/strong\u003e 2 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e Standard 4 mm shrouded banana\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating:\u003c\/strong\u003e 10 A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory ratings:\u003c\/strong\u003e CAT II 1000 V; CAT III 1000 V and CAT IV 600 V with protective caps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e −20°C to 55°C (−4°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 90% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m (6,562 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e Comfort-grip probes with right-angle leads; silicone insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Instruments that accept 4 mm shrouded banana connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eGet Trusted Fluke Accuracy\u003c\/h2\u003e\n\u003cp\u003eEquip your DMM with durable, safety-rated leads that stay flexible and readable in any season. \u003cstrong\u003eOrder today\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024253231360,"sku":"FLUKE-TL71-NEW","price":51.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/41cf05fe-3a89-4a1b-8210-b108002f5107_original__size_ac027551-cf96-4422-be24-8e342b4d9c18.webp?v=1784298337"},{"product_id":"fluke-28ii-trms-rugged-ip67-digital-multimeter-wuuek","title":"FLUKE-28II TRMS Rugged IP67 Digital Multimeter","description":"\u003cp\u003e[shortdesc] True-RMS, IP67 and 3 m drop, 1000 V\/10 A range, CAT IV 600 V, -15 to 55C operation, 800 h battery [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 28 II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTRMS Rugged IP67 Digital Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP67 (dustproof and waterproof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop Test\u003c\/td\u003e\n\u003ctd\u003e3 m (10 ft) with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/DC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/DC Current Range\u003c\/td\u003e\n\u003ctd\u003e0.1 uA to 10 A (20 A for 30 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0.1 Ohm to 50 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e1 nF to 9999 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 199.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-200 C to +1090 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Counts\u003c\/td\u003e\n\u003ctd\u003e6000 (20,000-count Hi-Res mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-Pass Filter (VSD)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003e8,000 V transients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 C to +55 C (-40 C up to 20 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eThree AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~800 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e6.35 x 10.0 x 19.81 cm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e698.5 g (1.54 lb) (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eMSHA Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange 0.1 mV to 1000 V; Accuracy +\/- (0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange 0.1 mV to 1000 V; Accuracy +\/- (0.7% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003eRange 0.1 uA to 10 A; Accuracy +\/- (0.2% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003eRange 0.1 uA to 10 A; Accuracy +\/- (1.0% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e0.1 Ohm to 50 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1 nF to 9999 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 199.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-200 C to +1090 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 counts; Hi-Res 20,000-count mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capture\u003c\/td\u003e\n\u003ctd\u003ePeak transient capture 250 us; Min\/Max\/Avg; Reading Hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Mode\u003c\/td\u003e\n\u003ctd\u003eYes (zero)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight \/ Bar Graph\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Bandwidth (Extended)\u003c\/td\u003e\n\u003ctd\u003e15 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eTL75 test leads; AC175 alligator clips; 80BK-A type-K thermocouple leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eMagnetic hanger (optional accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eBuilt for Harsh Sites, Accurate in Noisy Panels\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 28 II TRMS Digital Multimeter delivers lab-grade accuracy in tough field conditions. With IP67 sealing, a 3 m drop rating, and CAT IV 600 V\/CAT III 1000 V safety, it keeps you productive around VFDs (Variable Frequency Drives), switchgear, and outdoor installations. A dedicated low-pass filter and True-RMS measurements ensure stability on electrically noisy signals, while a built-in thermometer reduces the tools you carry.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuggedized IP67 design:\u003c\/strong\u003e Fully sealed (waterproof and dustproof) and drop tested to\u003cstrong\u003e \u003c\/strong\u003e3 m (10 ft) for reliable use in harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS with VFD low-pass filter:\u003c\/strong\u003e Get accurate voltage and current readings on non-linear loads and adjustable-speed motor drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide measurement ranges:\u003c\/strong\u003e Measure up to 1000 V AC\/DC, 10 A continuous (20 A for 30 s), resistance to 50 MOhm, capacitance up to 9999 uF, and frequency to 199.99 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermometer built in:\u003c\/strong\u003e Conveniently log temperature from -200 C to +1090 C with the included Type-K probe without carrying a separate instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong runtime and visibility:\u003c\/strong\u003e Up to 800 hours on three AA batteries, with large digits and a two-level bright white backlight for dark panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial maintenance on VFD-driven motors and pumps\u003c\/li\u003e\n\u003cli\u003eElectrical troubleshooting in plants, mining (MSHA approved), and utilities\u003c\/li\u003e\n\u003cli\u003eField service in outdoor or wet locations\u003c\/li\u003e\n\u003cli\u003eCommissioning and acceptance testing for control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT IV 600 V, CAT III 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 0.1 mV to 1000 V AC\/DC (True-RMS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 0.1 uA to 10 A (20 A for 30 s)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 1 nF to 9999 uF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 0.5 Hz to 199.99 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 0.1 Ohm to 50 MOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000 counts (20,000-count high-resolution mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection \u0026amp; Drop:\u003c\/strong\u003e IP67, 3 m (with holster)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp\/Humidity:\u003c\/strong\u003e -15 C to +55 C, 95% RH (down to -40 C for 20 min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Life:\u003c\/strong\u003e Three AA batteries, up to 800 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded:\u003c\/strong\u003e TL75 test leads, AC175 alligator clips, 80BK-A Type-K thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMake every reading count with Fluke\u003c\/h2\u003e\n\u003cp\u003eEquip your team with a meter built for industrial reality and compliant safety. Order the Fluke 28 II TRMS Multimeter today.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024253395200,"sku":"FLUKE-28II-NEW","price":790.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/69e99b5a-a40e-4fb3-94f4-b1080044c238_original__size_d0831aac-de6b-4acb-ae73-fa8d6f291511.webp?v=1784298338"},{"product_id":"fluke-tlk-225-suregrip-master-accessory-set-y0n0f","title":"Fluke TLK-225 SureGrip Master Accessory Set","description":"\u003cp\u003e[shortdesc] 13-piece SureGrip kit, TL224 leads \u0026amp; TP175 probes, AC220\/AC285\/AC280\/AC283 clips, six-pocket roll-up pouch, CAT II 1000 V, CAT III 1000 V, CAT IV 600 V [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke TLK-225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSureGrip Master Accessory Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Items\u003c\/td\u003e\n\u003ctd\u003e13-piece SureGrip™ test accessory set with six-pocket roll-up pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT II 1000 V, CAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eReplacement and expansion kit for all Fluke SureGrip™ leads and probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuild Quality\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade construction for reliable and accurate testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible with Fluke multimeters and test instruments supporting SureGrip™ accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eDurable silicone and insulated SureGrip™ materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrying Case\u003c\/td\u003e\n\u003ctd\u003eSix-pocket roll-up pouch for organized storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eComplies with IEC\/EN 61010 safety standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Pieces\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eCAT II 1000 V \/ CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Type\u003c\/td\u003e\n\u003ctd\u003eSureGrip™ silicone insulated leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eIndustrial and laboratory testing environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Case\u003c\/td\u003e\n\u003ctd\u003eFlexible six-pocket roll-up pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead and Probe Insulation\u003c\/td\u003e\n\u003ctd\u003eSilicone for improved flexibility and safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting Compatibility\u003c\/td\u003e\n\u003ctd\u003eAll SureGrip™ compatible test meters and adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Function\u003c\/td\u003e\n\u003ctd\u003eProvides versatility for electrical and electronic testing with secure grip and reliable contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded in the Box\u003c\/td\u003e\n\u003ctd\u003eTL224 SureGrip Silicone Test Lead Set; TP175 TwistGuard Test Probe Set; AC220 SureGrip Alligator Clip Set; AC285 SureGrip Large Jaw Alligator Clip Set; AC280 SureGrip Hook Clip Set; AC283 SureGrip Pincer Clip Set; Six-pocket roll-up pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eCompatible with Fluke digital multimeters, adapters, and specialty test leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eEquip Your Meter with the Complete SureGrip™ Accessory Set\u003c\/h2\u003e\n\u003cp\u003eThe Fluke TLK-225 SureGrip™ Master Accessory Set consolidates the most-used leads, probes, and clips into one durable roll-up pouch. It’s designed to help technicians maintain accurate, safe measurements and replace worn accessories across industrial test environments.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive 13-piece kit:\u003c\/strong\u003e Consolidates essential leads, probes, and clips to refresh or replace aging accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSureGrip™ comfort \u0026amp; control:\u003c\/strong\u003e Textured, ergonomic accessories improve handling and reduce slippage during measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial safety ratings:\u003c\/strong\u003e CAT II 1000 V, CAT III 1000 V, CAT IV 600 V classifications support safe use on a wide range of electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrganized portability:\u003c\/strong\u003e Six-pocket roll-up pouch keeps each component protected and easy to access on the job.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePlant maintenance and industrial electrical troubleshooting\u003c\/li\u003e\n\u003cli\u003eField service teams standardizing meter accessories\u003c\/li\u003e\n\u003cli\u003eCalibration and repair benches needing reliable replacement parts\u003c\/li\u003e\n\u003cli\u003eTraining labs and technical programs stocking complete test kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit contents:\u003c\/strong\u003e TL224 test lead set; TP175 TwistGuard™ probe set; AC220 alligator clip set; AC285 large-jaw alligator clip set; AC280 hook clip set; AC283 pincer clip set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePieces:\u003c\/strong\u003e 13 items total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety ratings:\u003c\/strong\u003e CAT II 1000 V; CAT III 1000 V; CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePouch:\u003c\/strong\u003e Six-pocket roll-up storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem compatibility:\u003c\/strong\u003e For Fluke SureGrip™ leads and probes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended environment:\u003c\/strong\u003e Industrial and professional electrical testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eReady to kit out your meter?\u003c\/h2\u003e\n\u003cp\u003eUpgrade your test setup with a complete, safety-rated accessory pack—\u003cstrong\u003eorder the TLK-225 today\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024254247168,"sku":"FLUKE-TLK-225-NEW","price":244.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/cd52f6c9-dfad-42c1-82d1-b108002f5442_original__size_1b309644-15b5-4b1b-b80f-c549449a8793.webp?v=1784298358"},{"product_id":"fluke-101-pocket-battery-powered-digital-multimeter-cat-iii-600-v-sqbn4","title":"FLUKE-101 Pocket Battery Powered Digital Multimeter, CAT III 600 V","description":"\u003cp\u003e[shortdesc] 0.5% DC accuracy, CAT III 600 V, continuity buzzer, auto shutdown, IP40, 130 x 65 x 27 mm [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e600.0 mV; 6.000 V; 60.00 V; 600.0 V (40–500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6.000 V; 60.00 V; 600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω; 4.000 kΩ; 40.00 kΩ; 400.0 kΩ; 4.000 MΩ; 40.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e50.00 nF; 500.0 nF; 5.000 μF; 50.00 μF; 100.0 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e50.00 Hz; 500.0 Hz; 5.000 kHz; 50.00 kHz; 100.0 kHz (10 Hz–100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1% to 99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity (Audible)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shutoff\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eTwo AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H × W × L)\u003c\/td\u003e\n\u003ctd\u003e130 mm × 65 mm × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−30 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges: 600.0 mV \/ 6.000 V \/ 60.00 V \/ 600.0 V; Resolutions: 0.1 mV \/ 0.001 V \/ 0.01 V \/ 0.1 V; Accuracy: 3.0% ± 3 digits (600 mV); 1.0% ± 3 digits (6 V, 60 V, 600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Measurement\u003c\/td\u003e\n\u003ctd\u003eRanges: 6.000 V \/ 60.00 V \/ 600.0 V; Resolutions: 0.001 V \/ 0.01 V \/ 0.1 V; Accuracy: 0.5% ± 3 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRanges: 400.0 Ω \/ 4.000 kΩ \/ 40.00 kΩ \/ 400.0 kΩ \/ 4.000 MΩ \/ 40.00 MΩ; Resolutions: 0.1 Ω \/ 0.001 kΩ \/ 0.01 kΩ \/ 0.1 kΩ \/ 0.001 MΩ \/ 0.01 MΩ; Accuracy: 0.5% ± 3 digits (400 Ω); 0.5% ± 2 digits (4 kΩ–4 MΩ); 1.5% ± 3 digits (40 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRanges: 50.00 nF \/ 500.0 nF \/ 5.000 μF \/ 50.00 μF \/ 100.0 μF; Resolutions: 0.01 nF \/ 0.1 nF \/ 0.001 μF \/ 0.01 μF \/ 0.1 μF; Accuracy: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eRanges: 50.00 Hz \/ 500.0 Hz \/ 5.000 kHz \/ 50.00 kHz \/ 100.0 kHz (10 Hz–100 kHz); Resolutions: 0.01 Hz \/ 0.1 Hz \/ 0.001 kHz \/ 0.01 kHz \/ 0.1 kHz; Accuracy: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eRange: 0.1% to 99.9%; Resolution: 0.1%; Accuracy: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop Test\u003c\/td\u003e\n\u003ctd\u003e1 m to surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eTL75 Test leads; 2 × AAA Batteries (installed); User’s manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eCases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eTest Lead Kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eReliable Everyday Testing in a Compact, Professional Meter\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 101 Digital Multimeter delivers dependable measurements for routine electrical checks in residential and commercial environments. Its small, lightweight design supports one-handed operation while a rugged build stands up to daily use. With CAT III 600 V safety, 0.5% basic DC accuracy, and fast continuity with buzzer, it’s a practical, professional-grade tool for electricians and HVAC technicians who need trustworthy readings without bulk.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT III 600 V safety:\u003c\/strong\u003e Safe for measurements on distribution-level circuits in residential and commercial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate DC measurements:\u003c\/strong\u003e 0.5% basic DC voltage accuracy helps validate circuits and troubleshoot confidently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential test coverage:\u003c\/strong\u003e AC\/DC voltage, resistance, capacitance, frequency, and duty cycle for broad daily diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast continuity with buzzer:\u003c\/strong\u003e Audible feedback speeds wire, fuse, and connection checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable and durable:\u003c\/strong\u003e 130 x 65 x 27 mm, 160 g, engineered to withstand a 1 m drop with IP40 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eField service and quick checks for residential or commercial electricians.\u003c\/li\u003e\n\u003cli\u003eHVAC troubleshooting and maintenance tasks.\u003c\/li\u003e\n\u003cli\u003ePanel, outlet, and appliance voltage verification.\u003c\/li\u003e\n\u003cli\u003eBench or toolbox meter for procurement-standard basic testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Ranges:\u003c\/strong\u003e 6.000 V \/ 60.00 V \/ 600.0 V (0.5% ± 3 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage Ranges (40–500 Hz):\u003c\/strong\u003e 600.0 mV \/ 6.000 V \/ 60.00 V \/ 600.0 V (3.0% ± 3 digits at 600 mV; 1.0% ± 3 digits at 6\/60\/600 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 400.0 Ω to 40.00 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 50.00 nF to 100.0 μF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50.00 Hz to 100.0 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e 0.1% to 99.9%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity\/Diode:\u003c\/strong\u003e Audible continuity and diode test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Two AAA batteries; automatic shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e 130 x 65 x 27 mm; 160 g; IP40; 1 m drop test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to 40 °C (storage −30 °C to 60 °C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eGet dependable measurements in a compact tool\u003c\/h2\u003e\n\u003cp\u003eEquip your team with a trusted, easy-to-carry meter that covers essential tests—order today.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024254443776,"sku":"FLUKE-101-NEW","price":114.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/d230fa52-dc8a-4517-99c3-b10800300020_original__size_157add4d-65ba-469c-91a2-c179431ccb93.webp?v=1784298360"},{"product_id":"fluke-ms2-100-microscanner2-ms2-100-cable-verifier-wq0hg","title":"FLUKE-MS2-100 MicroScanner2 MS2-100 Cable Verifier","description":"\u003cp\u003e[shortdesc] Wiremap, pair length and distance to fault, IntelliTone digital and analog, 10\/100\/1G port detect, coax testing via adapter, backlit LCD [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke Networks MicroScanner² \/ MicroScanner PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCable Verifier (Copper; PoE diagnostics on MicroScanner PoE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMonochrome LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Connectors\u003c\/td\u003e\n\u003ctd\u003e8-pin modular jack (RJ45) and 4-pin modular (RJ11); MicroScanner² also supports F-connector for coax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e2× AA (NEDA 15A, IEC LR6) alkaline; also supports 2× AA photo lithium, NiMH, NiCad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~20 hours (typical use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e3 × 6.4 × 1.4 in (7.6 × 16.3 × 3.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMicroScanner²: 13.5 oz (385 g); MicroScanner PoE: 10.6 oz (247 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32 °F to 113 °F (0 °C to 45 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−4 °F to 140 °F (−20 °C to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e90% (50 °F to 95 °F \/ 10 °C to 35 °C); 75% (95 °F to 113 °F \/ 35 °C to 45 °C) non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock \u0026amp; Vibration\u003c\/td\u003e\n\u003ctd\u003eRandom 2 g, 5 Hz–500 Hz (Class 2); 1 m drop test (with or without wiremap adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, 3rd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperation: 4,000 m; Storage: 12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Types Tested\u003c\/td\u003e\n\u003ctd\u003eTwisted pair: UTP, FTP, STP; Coax (MicroScanner² only): 75 Ω, 50 Ω, 93 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Test\u003c\/td\u003e\n\u003ctd\u003eRange 460 m (1500 ft); Resolution 0.3 m (1 ft); Typical accuracy ±(1% + 0.6 m \/ 2 ft) whichever is greater; NVP uncertainty is an additional error; User-settable NVP (twisted pair \u0026amp; coax)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiremap\u003c\/td\u003e\n\u003ctd\u003eDetects opens, shorts, miswires, split pairs; shows proportional length to fault; identifies up to seven far-end adapter IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port Detection\u003c\/td\u003e\n\u003ctd\u003eMicroScanner²: Advertised speeds of 10\/100\/1000BASE-T; MicroScanner PoE: Advertised speeds of 10 Mbps, 100 Mbps, 1 Gbps, 2.5 Gbps, 5 Gbps, 10 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE \/ Power over Ethernet\u003c\/td\u003e\n\u003ctd\u003eMicroScanner²: Detects 802.3af presence; MicroScanner PoE: Reports class \u0026amp; power for 802.3af\/at\/bt and shows voltage from passive PoE sources\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTone Generator\u003c\/td\u003e\n\u003ctd\u003eSupports digital IntelliTone™ and analog tones; SmartTone™ for positive cable identification; compatible with typical analog probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes (displayed)\u003c\/td\u003e\n\u003ctd\u003eLength, distance-to-fault, wiremap, pair lengths, Ethernet port detection; MicroScanner PoE additionally indicates HIGH Ω on cable resistance \u0026amp; PoE details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 512px;\" width=\"512\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"172\"\u003e \u003ccol style=\"width: 340px;\" width=\"340\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eMicroScanner² or MicroScanner PoE main unit; Main wiremap adapter; AA alkaline batteries; Getting Started Guide; Soft carrying case (included in the box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional – Remote Identifiers\u003c\/td\u003e\n\u003ctd\u003eMS2-IDK27 (Remote Identifier Kit #2–7); REMOTED-KIT (Remote ID kits for MicroScanner PoE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional – Probes\u003c\/td\u003e\n\u003ctd\u003eMT-8200-63A IntelliTone™ Pro 200 Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional – Adapters\u003c\/td\u003e\n\u003ctd\u003eCIQ-RJA RJ45\/11 Modular Adapter; CIQ-COAX Coax Adapter Kit (RCA, BNC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional – Cases \/ Mounts\u003c\/td\u003e\n\u003ctd\u003eMICRO-DIT Soft Carry Duffel; MS2-MAG-KIT Magnetic Strap Attachment \u0026amp; Spare Holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional – Kits\u003c\/td\u003e\n\u003ctd\u003eMS-POE-KIT; MS2-KIT; MS2-TTK; MS2-FTK (see kit contents in datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eFind Cable Faults Faster with MicroScanner2 Accuracy\u003c\/h2\u003e\n\u003cp\u003eFluke Networks’ MicroScanner2 MS2-100 speeds copper troubleshooting by showing wiremap, pair lengths, distance to fault, service presence, and far-end IDs on one screen. Built-in IntelliTone provides both digital and analog toning to locate cables precisely, while the unit verifies Ethernet port speeds up to 1 Gbps to confirm service availability. Rugged design and a soft case keep the tester ready for the toughest jobs.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-screen results:\u003c\/strong\u003e View wiremap, pair length, distance to fault, cable ID, and services simultaneously to cut test time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliTone toning:\u003c\/strong\u003e Digital and analog tone modes help pinpoint active data cables and trace voice or coax runs in noisy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGigabit service identification:\u003c\/strong\u003e Detects advertised 10\/100\/1000 Mbps Ethernet port speeds to validate links before handoff.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoax and voice support:\u003c\/strong\u003e Test RJ45, RJ11, and coax with the MicroScanner2 F-connector adapter for broader site coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged, field-ready:\u003c\/strong\u003e Backlit LCD, rubber holster, and soft carry case improve visibility and durability on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork installers verifying twisted-pair terminations and service availability\u003c\/li\u003e\n\u003cli\u003eDesk moves, adds, and changes across campus or branch networks\u003c\/li\u003e\n\u003cli\u003eField technicians tracing and labeling unknown copper drops\u003c\/li\u003e\n\u003cli\u003eFacilities teams maintaining voice, data, and coax distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable types:\u003c\/strong\u003e Twisted pair UTP\/FTP\/STP; coax with adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength test:\u003c\/strong\u003e Range 460 m (1500 ft), resolution 0.3 m (1 ft), accuracy ±(1% + 0.6 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiremap:\u003c\/strong\u003e Detects opens, shorts, splits, and up to seven far-end IDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet port detect:\u003c\/strong\u003e Advertised speeds of 10\/100\/1000 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTone generator:\u003c\/strong\u003e IntelliTone digital and compatible analog tones\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Monochrome LCD with backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 2 × AA alkaline, about 20 hours typical use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\/Weight:\u003c\/strong\u003e ~3 in × 6.4 in × 1.4 in; ~13 oz with batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eReady to troubleshoot like a pro\u003c\/h2\u003e\n\u003cp\u003eEquip your team with MicroScanner2 MS2-100 for faster, clearer copper diagnostics. \u003cstrong\u003eOrder today\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024279576832,"sku":"FLUKE-MS2-100-NEW","price":851.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/823_1_d096fb26-5d0b-4764-af61-f2a209431026.jpg?v=1784298462"},{"product_id":"fluke-1507-insulation-resistance-tester-xtsvz","title":"FLUKE-1507 Insulation Resistance Tester","description":"\u003cp\u003e[shortdesc] Fluke 1507 insulation tester with 50–1000 V test voltages, PI\/DAR calculations, AC\/DC measurement to 600 V, and resistance range 0.01 MΩ–10 GΩ. CAT IV 600 V rated. [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 1507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInsulation Resistance Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltages\u003c\/td\u003e\n\u003ctd\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/DC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0.1 V to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Test Current\u003c\/td\u003e\n\u003ctd\u003e200 mA (lo-ohms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e≥1000 insulation tests; ≥2500 continuity tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H × W × L)\u003c\/td\u003e\n\u003ctd\u003e5.0 × 10.0 × 20.3 cm (1.97 × 3.94 × 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to 55 °C (−4 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to 60 °C (−40 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (CAT IV 600 V), 3000 m (CAT III 600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003ctd\u003eRange 600 V; Resolution 0.1 V; 50–400 Hz; Accuracy ±(2% + 3); Input impedance 3 MΩ (\u0026lt;100 pF); CMRR \u0026gt; 60 dB; Overload protection 600 V rms\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity \/ Resistance\u003c\/td\u003e\n\u003ctd\u003e20.00 Ω \/ 0.01 Ω; 200.0 Ω \/ 0.1 Ω; 2000 Ω \/ 1.0 Ω; 20.00 kΩ \/ 0.01 kΩ; Accuracy ±(1.5% + 3); Short-circuit current \u0026gt;200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Current\/Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V, 100 V, 250 V, 500 V, 1000 V; Short-circuit current 1 mA nominal; Accuracy +20%, −0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Accuracy\u003c\/td\u003e\n\u003ctd\u003e50 V ±(3% + 5); 100 V ±(3% + 5); 250 V ±(1.5% + 5); 500 V ±(1.5% + 5); 1000 V ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive Circuit Indicator\u003c\/td\u003e\n\u003ctd\u003eTest inhibited if voltage \u0026gt;30 V detected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Discharge\u003c\/td\u003e\n\u003ctd\u003eDischarge \u0026lt;0.5 s for C ≤ 1 µF; operable up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–95% @ 10–30 °C; 0–75% @ 30–40 °C; 0–40% @ 40–55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock\u003c\/td\u003e\n\u003ctd\u003eRandom 2 g, 5–500 Hz (MIL-PRF-28800F Class 2); 1 m drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eAccuracy maintained in 3 V\/m RF field (EN 61326-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety \/ Certifications\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA 82.02.01, CAN\/CSA-C22.2 No. 61010-1, IEC\/EN 61010-1 2nd Ed; CAT IV 600 V; CSA \u0026amp; TUV certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range Capability\u003c\/td\u003e\n\u003ctd\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eTL224 Test Leads; TP74 Test Probes; Alligator clips PN 1958654 (red) \u0026amp; PN 1958646 (black); Holster; Remote probe; User documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional – Cases\u003c\/td\u003e\n\u003ctd\u003eFluke C101 Hard Case; Fluke C25 Large Soft Case; Fluke CAMO-C25 Camouflage Case; Fluke CXT170 Extreme Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional – Test Lead Kits\u003c\/td\u003e\n\u003ctd\u003eFluke TL81A Deluxe Electronic Test Lead Kit; Fluke TL225 SureGrip™ Stray Voltage Adapter Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch1\u003eFluke 1507 Insulation Resistance Tester\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 1507 is a compact, rugged insulation resistance tester designed for electrical contractors, industrial maintenance, and commercial electricians. With multiple test voltages (50–1000 V), PI\/DAR calculations, and built-in safety functions, it ensures reliable diagnostics in commissioning, troubleshooting, and preventive maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Insulation resistance 0.01 MΩ to 10 GΩ, with selectable test voltages from 50 V to 1000 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Built-in:\u003c\/strong\u003e Live circuit detection inhibits tests above 30 V; auto-discharge protects users from residual voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Function Tester:\u003c\/strong\u003e Measures AC\/DC voltage to 600 V, resistance 0.01 Ω–20 kΩ, and continuity with 200 mA test current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Remote probe simplifies repetitive or hard-to-reach testing; large backlit display improves visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable \u0026amp; Durable:\u003c\/strong\u003e Lightweight (550 g), IP40 rated, and delivers over 1000 insulation tests per set of AA batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRoutine insulation verification for electrical contractors\u003c\/li\u003e\n\u003cli\u003eMotor, cable, and switchgear testing in industrial maintenance\u003c\/li\u003e\n\u003cli\u003eCommissioning compliance testing in new installations\u003c\/li\u003e\n\u003cli\u003eSolar and renewable energy insulation safety checks\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance in commercial facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrder with Confidence\u003c\/h2\u003e\n\u003cp\u003eEngineered for professionals who demand accuracy, safety, and reliability, the Fluke 1507 is the trusted choice for insulation testing. Buy today to upgrade your testing capability.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024358121728,"sku":"FLUKE-1507-NEW","price":917.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Fluke1507_a472678a-a9a6-4168-8d7a-2ce290737b2a.webp?v=1784298756"},{"product_id":"fluke-302-cat-iii-digital-clamp-meter-xu6dv","title":"FLUKE-302+ CAT III Digital Clamp Meter","description":"\u003cp\u003e[shortdesc]\u003cbr\u003e\u003cbr\u003eCompact, 400A AC, 30 mm jaw, CAT III 600V\/CAT IV 300V, 1.8% accuracy, Backlit display\u003cbr\u003e\u003cbr\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch2\u003eTrusted Accuracy for Fast Electrical Diagnostics\u003c\/h2\u003e\n\u003cp\u003eElectrical technicians need tools that are compact, durable, and deliver dependable readings in real-world environments. The \u003cstrong data-end=\"932\" data-start=\"918\"\u003eFluke 302+\u003c\/strong\u003e answers the call with a practical, no-frills design that streamlines everyday current measurement. With the ability to measure AC current up to \u003cstrong data-end=\"1086\" data-start=\"1077\"\u003e400 A\u003c\/strong\u003e, a wide 30 mm jaw, and a high accuracy of \u003cstrong data-end=\"1137\" data-start=\"1129\"\u003e1.8%\u003c\/strong\u003e, this clamp meter is the technician's go-to for quick, effective maintenance checks — all in a tool small enough to carry every day.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current Measurement:\u003c\/strong\u003e Measures AC current up to 400 A, handling your everyday electrical maintenance needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Flexible Design:\u003c\/strong\u003e The clamp meter is more compact, making the use of a clamp-type ammeter more flexible and simpler. It features a large 30 mm jaw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Delivers a high accuracy of 1.8%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rated:\u003c\/strong\u003e Meets a CAT IV 300V\/CAT III 600V safety rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit Display:\u003c\/strong\u003e Includes a backlit display for improved visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e Comes with the TL75 Hard Point™ Test Lead Set, offering the convenience of a test lead and probe in one unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current Range: \u003c\/strong\u003eUp to 400 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Size:\u003c\/strong\u003e 30 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy: \u003c\/strong\u003e±1.8%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT IV 300 V \/ CAT III 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Backlit LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e TL75 Test Leads, 2x AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Lead Rating: \u003c\/strong\u003eCAT II 1000 V, 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpgrade Your Electrical Toolkit Today\u003c\/h2\u003e\n\u003cp\u003eGet compact performance and proven Fluke reliability with the 302+ Digital Clamp Meter. It's a rugged, easy-to-use tool designed to deliver reliable measurements time after time. Order today and equip your toolkit with reliable performance!\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024359366912,"sku":"FLUKE-302+-NEW","price":151.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/front-302-clamp-meter_c15977e3-39d7-4f04-b672-2a6b5a238677.webp?v=1784298772"},{"product_id":"fluke-971-temperaturehumidity-meter-imngr","title":"Fluke 971 Temperature\/Humidity Meter","description":"\u003cp\u003e[shortdesc]\u003cbr\u003e\u003cbr\u003eMonitor indoor air quality effectively with the FLUKE-971, a compact temperature and humidity meter with dual backlit display, fast response time, and 99-record memory.\u003cbr\u003e\u003cbr\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 971 Temperature\/Humidity Meter\u003c\/h1\u003e\n\u003cp\u003eThe FLUKE-971 Temperature\/Humidity Meter is a reliable handheld device designed to measure and log ambient temperature and relative humidity quickly and accurately. Ideal for HVAC professionals, IAQ specialists, and facility technicians, this rugged tool features a dual backlit display, compact design, and ergonomic handling with belt clip and protective holster. It also calculates dew point and wet bulb measurements, making it essential for maintaining indoor comfort and safety in professional environments.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual backlit display for temperature and humidity readings\u003c\/li\u003e\n\u003cli\u003eTemperature range from -20 °C to 60 °C (-4 °F to 140 °F)\u003c\/li\u003e\n\u003cli\u003eRelative humidity range from 5% to 95% R.H.\u003c\/li\u003e\n\u003cli\u003eQuick-response capacitance sensor with protective cover\u003c\/li\u003e\n\u003cli\u003eStores up to 99 data records\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Avg data hold functionality\u003c\/li\u003e\n\u003cli\u003eMeasures dew point and wet bulb values\u003c\/li\u003e\n\u003cli\u003eLow battery indicator and fast 500 ms temperature update rate\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight design (190 g \/ 6.7 oz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20 °C to 60 °C (-4 °F to 140 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy:\u003c\/strong\u003e ±0.5 °C (0 °C to 45 °C), ±1.0 °C for other ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% R.H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Accuracy:\u003c\/strong\u003e ±2.5% R.H. (10% to 90%), ±5.0% outside that range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Sensor:\u003c\/strong\u003e Electronic capacitance polymer film sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (Humidity):\u003c\/strong\u003e 60 seconds with 1 m\/s airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Storage:\u003c\/strong\u003e 99 points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e 4 x AAA alkaline (200 hours typical battery life)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (HxWxD):\u003c\/strong\u003e 194 mm x 60 mm x 34 mm (7.6 in x 2.4 in x 1.3 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 190 g (6.7 oz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -20 °C to 60 °C (humidity operation up to 55 °C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temp:\u003c\/strong\u003e -20 °C to 60 °C (with battery removed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Approval:\u003c\/strong\u003e EN 61326-1 compliant for electromagnetic compatibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024380469504,"sku":"FLUKE-971-NEW","price":368.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/f-971-01b-1500x1000_4dd5eeac-092b-4590-9c7f-ddee65e9fea1.webp?v=1784298899"},{"product_id":"fluke-87vmax-true-rms-digital-multimeter-396i7","title":"FLUKE-87VMAX True-RMS Digital Multimeter","description":"\u003cp\u003e[shortdesc]\u003cbr\u003e\u003cbr\u003eThe FLUKE-87VMAX is an industrial-grade True-RMS digital multimeter engineered to withstand harsh environments. It offers IP67 waterproofing, drop protection from up to 4 meters, extended temperature tolerance, and up to 800 hours of battery life.\u003cbr\u003e\u003cbr\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-87VMAX True-RMS Digital Multimeter\u003c\/h1\u003e\n\u003cp\u003eDesigned for use in extreme conditions, the FLUKE-87VMAX True-RMS Digital Multimeter combines trusted precision with rugged durability. With its IP67 rating for water and dust resistance, and a robust housing that survives 4-meter drops, it’s ideal for industrial and field environments. It provides accurate True-RMS readings for AC\/DC voltage and current, plus frequency, temperature, resistance, continuity, and diode checks. A built-in thermometer, high-resolution 19,999 count display, and large, backlit keypad improve usability in low-light and electrically noisy conditions.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC\/DC voltage and current measurements\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000 V and 10 A (20 A for 30 seconds)\u003c\/li\u003e\n\u003cli\u003eFrequency measurements up to 200 kHz\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature function with included thermocouple\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average recording and 250 μs Peak capture\u003c\/li\u003e\n\u003cli\u003eVariable frequency drive (VFD) filtering for accurate motor readings\u003c\/li\u003e\n\u003cli\u003eLarge dual-level backlit display and keypad lighting\u003c\/li\u003e\n\u003cli\u003eIP67 rated waterproof and dustproof housing\u003c\/li\u003e\n\u003cli\u003eWithstands 4-meter (13 ft) drops\u003c\/li\u003e\n\u003cli\u003eBattery life up to 800 hours on three AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Accuracy:\u003c\/strong\u003e ±(0.05% + 1), Range: 0.1 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage Accuracy:\u003c\/strong\u003e ±(0.7% + 4), Range: 0.1 mV to 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e ±(0.2% + 2), up to 10 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current:\u003c\/strong\u003e ±(1.0% + 2), up to 10 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 0.1 Ω to 50 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 0.01 nF to 9999 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 0.5 Hz to 199.99 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e -200 °C to +1090 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 19,999 count high-resolution mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT IV 600 V, CAT III 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP67 (waterproof and dustproof)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop Protection:\u003c\/strong\u003e Up to 4 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 3x AA batteries (800-hour life)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 6.0 cm x 10.1 cm x 21.5 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 698.5 g (with holster)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024392528128,"sku":"FLUKE-87VMAX-NEW","price":759.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fluke-87-v-max-true-rms-multimeter_58db8206-dbfb-47bc-885f-af4c1658f1ac.png?v=1784298942"},{"product_id":"fluke-175-true-rms-digital-multimeter-anhq4","title":"FLUKE-175 True-RMS Digital Multimeter","description":"\u003cp\u003e[shortdesc]\u003cbr\u003e\u003cbr\u003eThe FLUKE-175 True-RMS Digital Multimeter delivers precision and durability for everyday electrical troubleshooting. Designed for professionals, it features accurate true-RMS readings, 6000-count display, and rugged construction to ensure reliability on the job.\u003cbr\u003e\u003cbr\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-175 True-RMS Digital Multimeter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 175 is a dependable multimeter designed for general-purpose electrical and electronic diagnostics. It offers accurate True-RMS measurements, a 6000-count digital display, analog bar graph, and both auto\/manual ranging modes. With CAT III 1000V and CAT IV 600V safety ratings, it’s suitable for demanding environments. \u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS for precise AC voltage and current measurement\u003c\/li\u003e\n\u003cli\u003e6000-count digital display with analog bar graph\u003c\/li\u003e\n\u003cli\u003eBasic DC accuracy of 0.09%\u003c\/li\u003e\n\u003cli\u003eAuto and manual ranging\u003c\/li\u003e\n\u003cli\u003eVoltage measurement up to 1000 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent measurement up to 10 A AC\/DC\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 50 MΩ\u003c\/li\u003e\n\u003cli\u003eFrequency measurement up to 100 kHz\u003c\/li\u003e\n\u003cli\u003eCapacitance measurement up to 10,000 µF\u003c\/li\u003e\n\u003cli\u003eContinuity and diode testing included\u003c\/li\u003e\n\u003cli\u003eBacklit screen for low-light conditions\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average recording with display hold and AutoHOLD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay Count: 6000\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -10 °C to +50 °C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -30 °C to +60 °C\u003c\/li\u003e\n\u003cli\u003eHumidity: 0%–90% (0–35 °C), 0%–70% (35–50 °C)\u003c\/li\u003e\n\u003cli\u003eDimensions: 185 x 90 x 43 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 420 g\u003c\/li\u003e\n\u003cli\u003eBattery Life: Approx. 200 hours (alkaline, no backlight)\u003c\/li\u003e\n\u003cli\u003eOvervoltage Protection: CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003eCertifications: UL, CSA, TÜV, CE\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024392659200,"sku":"FLUKE-175-NEW","price":460.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fluke-175-multimeter_300dpi_251x350mm-1500x1000_ba22a373-56cc-48d9-94b3-fe7f11aa3b43.webp?v=1784298944"},{"product_id":"fluke-902fc-true-rms-hvac-clamp-meter-xpezx","title":"FLUKE-902FC True-RMS HVAC Clamp Meter","description":"\u003cp\u003e[shortdesc]\u003cbr\u003e\u003cbr\u003eThe FLUKE-902FC is a robust, true-RMS wireless HVAC clamp meter designed for professionals who need safe, accurate, and efficient diagnostics in electrical and HVAC systems. With wireless data logging via Fluke Connect®, it simplifies measurement, reporting, and collaboration in demanding field conditions.\u003cbr\u003e\u003cbr\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-902FC True-RMS HVAC Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 902 FC is a compact and durable clamp meter that provides accurate true-RMS measurements for troubleshooting HVAC and electrical systems. With wireless connectivity via Fluke Connect®, professionals can log data, generate reports, and share readings in real time, improving productivity and safety. Its wide measurement range includes AC\/DC voltage, current, capacitance, resistance, microamps, and temperature, which makes it an all-in-one solution for HVAC maintenance tasks.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC voltage and current for precise measurement on non-linear loads\u003c\/li\u003e\n\u003cli\u003e600 A AC current and 600 V AC\/DC voltage measurement capacity\u003c\/li\u003e\n\u003cli\u003eTemperature measurement from -10 °C to 400 °C (14 °F to 752 °F)\u003c\/li\u003e\n\u003cli\u003e200 µA DC current range ideal for flame sensor diagnostics\u003c\/li\u003e\n\u003cli\u003e1000 µF capacitance measurement for HVAC capacitor testing\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 60 kΩ\u003c\/li\u003e\n\u003cli\u003eMin\/Max recording to capture fluctuations automatically\u003c\/li\u003e\n\u003cli\u003eBacklit display for visibility in dim environments\u003c\/li\u003e\n\u003cli\u003eCAT III 600V \/ CAT IV 300V safety rated\u003c\/li\u003e\n\u003cli\u003eWireless data sharing and logging with Fluke Connect® app\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current:\u003c\/strong\u003e 60\/600 A, ±2.0% accuracy (45–65 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e AC\/DC up to 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 60,000 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 1000 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroamps:\u003c\/strong\u003e 200 µA DC, ideal for flame sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -10 °C to 400 °C (14 °F to 752 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity Beeper:\u003c\/strong\u003e 75 dBA @ 15 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Large backlit LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2 AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e -10 °C to +50 °C, up to 90% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 230 × 83.7 × 45.4 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 419 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e IEC 61010 CAT III 600 V \/ CAT IV 300 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024392888576,"sku":"FLUKE-902FC-NEW","price":423.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/58_3e7708ca-34a2-41db-9989-364460934445.webp?v=1784298947"},{"product_id":"fluke-179eda2-kit-digital-multimeter-and-eda2-accessories-kit-31qgh","title":"FLUKE-179\/EDA2-KIT Digital Multimeter and EDA2 Accessories Kit","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cp\u003eFluke 179\/EDA2 Kit delivers precision measurement for professional technicians with True-RMS readings, built-in thermometer, and comprehensive accessories for advanced electrical troubleshooting\u003c\/p\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-179\/EDA2-KIT Digital Multimeter and EDA2 Accessories Kit\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 179\/EDA2 Kit is a high-performance solution for professionals who require dependable and accurate digital measurement. This kit includes the Fluke 179 True-RMS Digital Multimeter along with the EDA2 accessories bundle, featuring SureGrip™ test leads, probes, alligator clips, and a ToolPak magnetic hanger for hands-free operation. Designed for both electrical and electronic systems, the Fluke 179 provides reliable True-RMS measurements, temperature sensing, and diagnostics.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC voltage and current for precise readings\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermometer with -40°C to +400°C range (Fluke 179 only)\u003c\/li\u003e\n\u003cli\u003eMeasures voltage (AC\/DC) up to 1000 V, current up to 10 A\u003c\/li\u003e\n\u003cli\u003eSupports frequency, resistance, continuity, capacitance, and diode testing\u003c\/li\u003e\n\u003cli\u003eAnalog bargraph, backlight display, and MIN\/MAX\/AVG recording\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection: CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003eIncludes TL75 test leads, 80BK-A temperature probe, user manual, and installed 9V battery\u003c\/li\u003e\n\u003cli\u003eToolPak magnetic hanger for easy and secure placement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e ±(0.09% + 2), max 1000 V, resolution 0.1 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e ±(1.0% + 3), max 1000 V, True-RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e ±(1.0% + 3), max 10 A, resolution 0.01 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current:\u003c\/strong\u003e ±(1.5% + 3), max 10 A, True-RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e ±(0.9% + 1), up to 50 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e ±(1.2% + 2), max 10,000 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e ±(0.1% + 1), max 100 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e ±(1.0% + 10), range -40°C to +400°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -30°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity (non-condensing):\u003c\/strong\u003e 0–90% (≤35°C), 0–70% (≤50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e ~200 hours (alkaline, no backlight)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 43 x 90 x 185 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 420 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024394330368,"sku":"FLUKE-179\/EDA2-KIT-NEW","price":526.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/3504858BE311F3053D5D0B10E9B285DEBEFBF23F36300AF8D2F8D10CE0643472_5934b9cb-d1cd-48eb-b137-2f26191bf1c7.jpg?v=1784298968"},{"product_id":"fluke-9062-motor-and-phase-rotation-indicator-tpgy7","title":"FLUKE-9062 Motor and Phase Rotation Indicator","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe FLUKE-9062 is a compact and reliable motor and phase rotation tester supporting 3-phase detection and non-contact motor rotation direction checks, ideal for maintenance and troubleshooting in commercial and industrial systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-9062 Motor and Phase Rotation Indicator\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 9062 Motor and Phase Rotation Indicator is a versatile, handheld diagnostic tool designed for detecting phase sequence and motor rotation direction. It enables contact-free detection of the running direction of motors and features clearly labeled LED indicators for fast and intuitive operation. Operating across a wide voltage range up to 400V and frequencies between 2 to 400 Hz, it’s ideal for HVAC, electrical, and automation technicians. Its compact build, safety certifications, and IP40 rating make it suitable for demanding environments.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-Phase Indication:\u003c\/strong\u003e Displays all three phases with clear LED feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Rotation Detection:\u003c\/strong\u003e Determines the correct phase sequence to prevent wiring faults\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Motor Direction Testing:\u003c\/strong\u003e Identifies motor shaft direction without connecting directly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage \u0026amp; Frequency Range:\u003c\/strong\u003e Supports 120–400 V AC and 2–400 Hz systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e Operates reliably between 0°C to 40°C and up to 2000m altitude\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified Safety:\u003c\/strong\u003e EN 61010, EN 61557-7, CAT III 300 V rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Portable:\u003c\/strong\u003e Lightweight form factor with one 9V battery operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Fluke 9062\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Display Range:\u003c\/strong\u003e 120 to 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e Up to 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 2 to 400 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Timer:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e Up to 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 15% to 80% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Category:\u003c\/strong\u003e CAT III, 300 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 61010, EN 61557-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 1 x 9V battery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 124 x 61 x 27 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 130 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024400392448,"sku":"FLUKE-9062-NEW","price":394.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/1072_1_6fd98800-de06-42d1-9137-1a1d650de761.jpg?v=1784298977"},{"product_id":"fluke-378-fc-true-rms-clamp-meter-with-iflex-aifvp","title":"FLUKE-378-FC True-RMS Clamp Meter with iFlex","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 378 FC is a True-RMS clamp meter with FieldSense™ technology for safe, non-contact AC\/DC voltage and current measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-378-FC True-RMS Clamp Meter with iFlex\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 378 FC delivers fast and safe voltage and current measurements without making contact with live wires, thanks to FieldSense™ technology. It supports AC\/DC voltage up to 1000 V and current up to 2500 A with the iFlex® flexible current probe, allowing enhanced access in tight spaces. Designed for electricians and maintenance professionals, this clamp meter also provides a visual power quality indicator to identify voltage, current, or power anomalies, streamlining diagnostics in three-phase systems. Fully compatible with the Fluke Connect® app, it enables remote logging and data sharing, improving field efficiency and safety.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldSense™ Technology:\u003c\/strong\u003e Measure voltage and current without test leads, enabling safe, contactless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex Flexible Probe:\u003c\/strong\u003e Includes iFlex® probe to measure up to 2500 A AC current in tight or crowded panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Accuracy:\u003c\/strong\u003e Provides precise readings on non-linear signals in industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Quality Indicator:\u003c\/strong\u003e LED-based alerts for quick diagnostics of faults in the power system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Display:\u003c\/strong\u003e Simultaneous voltage and current readouts for comprehensive measurements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluke Connect® Compatible:\u003c\/strong\u003e Wireless data logging, storage, and team collaboration via mobile devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT Ratings:\u003c\/strong\u003e Safety rated for CAT III 1000 V \/ CAT IV 600 V applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (Clamp Jaw):\u003c\/strong\u003e Up to 999.9 A, accuracy ±2% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (iFlex):\u003c\/strong\u003e Up to 2500 A, accuracy ±3% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e Up to 999.9 A, accuracy ±2% ±10 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage (Test Leads):\u003c\/strong\u003e Up to 1000 V, accuracy ±1% ±5 digits (AC), ±1% ±10 digits (DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 60 kΩ, accuracy ±1% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 1000 µF, accuracy ±1% ±4 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency (Jaw \u0026amp; iFlex):\u003c\/strong\u003e 45 Hz – 66 Hz (jaw), 5 Hz – 500 Hz (iFlex)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Dual-readout digital LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 34 mm; iFlex cable length: 1.8 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP30 (jaw closed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Approx. 200 hours with 2x AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 274 x 86 x 47 mm; Weight: 463 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Frequency:\u003c\/strong\u003e 2405–2480 MHz (BLE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e IEC 61010 CAT III 1000 V \/ CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024404816128,"sku":"FLUKE-378-FC-NEW","price":924.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Z60NX7k1LzbuzgQ0H9OXVC50KAqXMSJhoIbOENT6_624ec9d2-4ffa-41a3-a53a-4a97f9db8084.jpg?v=1784298982"},{"product_id":"fluke-1630-2-fc-earth-ground-clamp-37cn6","title":"Fluke-1630-2-FC Earth Ground Clamp","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Fluke 1630-2 FC is a stakeless earth ground clamp that performs safe, fast indoor\/outdoor ground resistance and AC leakage tests without disconnecting grounding electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 1630-2 FC Earth Ground Clamp\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Earth Ground Clamp offers an advanced, stakeless solution for ground loop resistance and AC leakage current testing, making it ideal for both indoor and outdoor installations where auxiliary test stakes are not practical. This rugged tool allows measurements on multi-grounded systems without disconnecting the grounding electrode. Featuring Fluke Connect® wireless technology, the clamp enables technicians to view, record, and share measurements from their smartphone or tablet. Its heavy-duty jaw ensures long-term alignment and calibration, and the built-in memory logs up to 32,760 readings. With selectable filters, alarm thresholds, and high accuracy, the 1630-2 FC is a powerful diagnostic tool for maintenance professionals.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStakeless Measurement:\u003c\/strong\u003e Test grounding without auxiliary stakes or disconnection. Ideal for buildings, power pylons, and paved environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluke Connect® Integration:\u003c\/strong\u003e View, store, and share measurements wirelessly via mobile app with cloud backup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Leakage Detection:\u003c\/strong\u003e Accurately measure leakage currents from 0.200 mA to 39.99 A without system interruption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogging Capability:\u003c\/strong\u003e Automatically records up to 32,760 measurements at user-defined intervals for trending and analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy \u0026amp; Range:\u003c\/strong\u003e Earth ground loop resistance from 0.025 Ω to 1500 Ω; leakage current with resolution down to 1 μA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Build:\u003c\/strong\u003e Clamp remains aligned and calibrated in tough industrial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Thresholds:\u003c\/strong\u003e Set custom high\/low alarms for fast evaluation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e Band-pass filter option reduces noise in AC leakage readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Fluke 1630-2 FC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Ground Loop Resistance:\u003c\/strong\u003e 0.025 Ω to 1500 Ω (±1.5% to ±20.0% depending on range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Leakage Current:\u003c\/strong\u003e 0.200 mA to 39.99 A; resolution: 1 μA to 10 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e More than 15 hours (4 x AA alkaline)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 9999-count digital LCD; 4 readings\/sec refresh rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Logging:\u003c\/strong\u003e Up to 32,760 readings; interval from 1s to 59m 59s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Range:\u003c\/strong\u003e 2412 MHz–2462 MHz; \u0026lt;10 mW output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp Size:\u003c\/strong\u003e 40 mm (1.57 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 880 g (31 oz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP30 (with jaw closed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10 °C to +50 °C (14 °F to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e Up to 2000 m (6561 ft operating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CAT IV 600V \/ CAT III 1000V, IEC\/EN 61010-2-032, FCC, CE, TÜV\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024407306496,"sku":"Fluke-1630-2-FC-NEW","price":2567.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/1ac-II-voltage-tester_0_b0553372-a9ce-4602-89ad-c01724c7a32c.webp?v=1784299002"},{"product_id":"fluke-393-fc-true-rms-clamp-meter-with-iflex-cat-iii-1500-v-gfxev","title":"FLUKE-393-FC True-RMS Clamp Meter with iFlex CAT III 1500 V","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 393 FC is the only CAT III 1500 V rated true-RMS clamp meter, designed for solar, wind, and battery storage applications with iFlex current probe support up to 2500 A AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-393-FC True-RMS Clamp Meter with iFlex CAT III 1500 V\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 393 FC is a rugged, true-RMS clamp meter engineered for high-voltage DC environments like solar PV systems, EV charging stations, battery banks, and industrial power installations. Rated for CAT III 1500 V and CAT IV 600 V, it delivers safe and accurate measurements up to 1500 V DC, 1000 V AC, and 999.9 A through the clamp jaw. With the included iFlex flexible probe, AC current measurement expands up to 2500 A. The thin jaw design provides easy access to conductors in crowded combiner boxes, and features like visual continuity, audio polarity indication, and real-time data logging via Fluke Connect enhance productivity and safety on-site.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT III 1500 V Safety:\u003c\/strong\u003e The only clamp meter rated for CAT III 1500 V and CAT IV 600 V applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage \u0026amp; Current Range:\u003c\/strong\u003e Measures up to 1500 V DC, 1000 V AC, and 999.9 A with clamp jaw; 2500 A AC with iFlex probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar \u0026amp; Battery-Ready:\u003c\/strong\u003e Designed for use on solar arrays, wind systems, battery banks, and rail systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Power Measurement:\u003c\/strong\u003e Displays kVA readings directly for system efficiency checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex Flexible Current Probe:\u003c\/strong\u003e Enables access to tight or crowded spaces for large AC current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual \u0026amp; Audio Indicators:\u003c\/strong\u003e Bright green continuity light and polarity beep reduce human error in noisy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluke Connect Compatible:\u003c\/strong\u003e Wireless syncing, logging, and reporting to smartphone\/cloud.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP54 Rated:\u003c\/strong\u003e Built for outdoor and dusty environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (Clamp Jaw):\u003c\/strong\u003e Up to 999.9 A ±2% + 5 digits (10–100 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (iFlex):\u003c\/strong\u003e Up to 2500 A ±3% + 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e Up to 999.9 A ±2% + 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 600.0 V \/ 1000 V AC, 600.0 V \/ 1500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Power:\u003c\/strong\u003e 600.0 kVA and 1500 kVA ±2% + 2.0\/20 kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 600.0 Ω \/ 6000 Ω \/ 60.00 kΩ ±1% + 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 100.0 μF \/ 1000 μF ±1% + 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Dual with backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 34 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex Diameter:\u003c\/strong\u003e 7.5 mm; cable length: 1.8 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 2 x AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power Off:\u003c\/strong\u003e After 20 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 281 x 84 x 49 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 520 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC 61010-2-032 \u0026amp; 61010-2-033; FCC, IC, CE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024407372032,"sku":"FLUKE-393-FC-NEW","price":891.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/F-393fc_01a_w_b77f6791-421d-4360-8c15-836447f77d4a.webp?v=1784299003"},{"product_id":"fluke-1503-insulation-resistance-meter-dlyii","title":"FLUKE-1503 Insulation Resistance Meter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1503 is a compact insulation resistance tester offering 500 V and 1000 V test voltages, a wide resistance range up to 2000 MΩ, and built-in live circuit detection for safe residential and commercial testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-1503 Insulation Resistance Meter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 1503 Insulation Resistance Meter is a rugged and easy-to-use tool ideal for residential and commercial electricians. It supports insulation testing from 0.01 MΩ to 2000 MΩ using two selectable test voltages (500 V and 1000 V). The device includes live circuit detection that prevents testing when voltages exceed 30 V for added safety. With a built-in remote test probe, the 1503 simplifies repetitive testing and enhances user convenience. It also features AC\/DC voltage measurement up to 600 V, low-ohms continuity testing with 200 mA, auto-discharge of capacitive voltage, and a large backlit display for better readability in all environments.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance Testing:\u003c\/strong\u003e Measures from 0.01 MΩ to 2000 MΩ using 500 V and 1000 V test voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive Circuit Detection:\u003c\/strong\u003e Automatically disables insulation testing if terminal voltage exceeds 30 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity Testing:\u003c\/strong\u003e Provides lo-ohms testing with a 200 mA short-circuit current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage Measurement:\u003c\/strong\u003e Measures from 0.1 V to 600 V with ±(2% + 3) accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rated:\u003c\/strong\u003e CAT IV 600 V overvoltage protection for enhanced operational safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Test Probe:\u003c\/strong\u003e Included probe allows easier operation in tight or repetitive test scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit Display:\u003c\/strong\u003e Large, clear screen for reliable readings even in dim workspaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Efficiency:\u003c\/strong\u003e Performs at least 1000 insulation tests or 2500 resistance tests on 4 AA batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance Range:\u003c\/strong\u003e 0.01 MΩ to 2000 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltages:\u003c\/strong\u003e 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Accuracy:\u003c\/strong\u003e ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage Range:\u003c\/strong\u003e 0.1 V to 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Bond Resistance:\u003c\/strong\u003e 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity Test Current:\u003c\/strong\u003e \u0026gt;200 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Discharge:\u003c\/strong\u003e \u0026lt;0.5 seconds for 1 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Capacitive Load:\u003c\/strong\u003e Operable up to 1 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Large backlit LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 4 x AA alkaline batteries (NEDA 15A or IEC LR6)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 1000 insulation tests or 2500 resistance tests\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -20°C to 55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 550 g (1.2 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CSA, TUV, EN61010-1, CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024407535872,"sku":"FLUKE-1503-NEW","price":526.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/f-1503-01a-1500x1000_d048f93e-cf92-449e-ac92-8d36ea9c0d81.webp?v=1784299006"},{"product_id":"fluke-377fc-true-rms-acdc-clamp-meter-with-iflex-xyknw","title":"FLUKE-377FC True-RMS AC\/DC Clamp Meter with iFlex","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 377 FC True-RMS Clamp Meter with iFlex enables contactless voltage and current measurement using FieldSense™, includes 2500 A flexible probe, and supports wireless data logging with Fluke Connect®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-377FC True-RMS AC\/DC Clamp Meter with iFlex\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 377 FC offers a safer, faster way to measure voltage and current using FieldSense™ technology—without contact with live conductors. Ideal for industrial electricians and maintenance professionals, this meter allows complete 3-phase voltage and current tests in just three steps, displaying results on the meter or syncing them wirelessly to the cloud via Fluke Connect®.\u003c\/p\u003e\n\u003cp\u003eEquipped with an iFlex® flexible current probe, the 377 FC measures up to 2500 A AC and provides easier access around large conductors in confined spaces. Visual Continuity enhances usability in noisy areas, while the large backlit display and automatic range selection ensure clarity and convenience on the job. The rugged design make it a reliable tool for any demanding environment.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldSense™ Technology:\u003c\/strong\u003e Perform AC voltage and current measurements without touching live wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex® Flexible Probe:\u003c\/strong\u003e Measures AC current up to 2500 A and improves access around tight conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Logging:\u003c\/strong\u003e Sync data with the Fluke Connect® app for remote monitoring and report generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-Phase Testing:\u003c\/strong\u003e Complete 3-phase voltage and current testing with automatic phase rotation display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Continuity:\u003c\/strong\u003e Bright green screen signals continuity in noisy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Readout Display:\u003c\/strong\u003e Shows voltage and current simultaneously with backlight support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT IV 600 V \/ CAT III 1000 V Safety Rated:\u003c\/strong\u003e Provides enhanced protection in high-energy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mounting:\u003c\/strong\u003e Includes TPAK magnetic hanger for hands-free operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e iFlex probe, test leads, TwistGuard™ probes, grounding clip, case, and more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (Jaw):\u003c\/strong\u003e Up to 999.9 A (±2% ±5 digits, 45–66 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (iFlex):\u003c\/strong\u003e Up to 2500 A (±3% ±5 digits, 5–500 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e Up to 999.9 A (±2% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage (FieldSense):\u003c\/strong\u003e Up to 1000 V (±3%–5% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage (Leads):\u003c\/strong\u003e Up to 1000 V (±1% ±5–10 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 60 kΩ (±1% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 1000 μF (±1% ±4 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency (Jaw):\u003c\/strong\u003e 45 Hz–66 Hz (±0.5% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency (iFlex):\u003c\/strong\u003e 5 Hz–500 Hz (±0.5% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Dual readout LCD with backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2× AA batteries (approx. 200-hour life)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 34 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex Cable Length:\u003c\/strong\u003e 1.8 m | Coil Length: 450 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L×W×H):\u003c\/strong\u003e 274 mm × 86 mm × 47 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 463 g (with batteries)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10 °C to 50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP30 (jaw closed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m (operating), 12000 m (storage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Range:\u003c\/strong\u003e 2405 MHz–2480 MHz, \u0026lt;100 mW output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024408420608,"sku":"FLUKE-377FC-NEW","price":891.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/F-377fc_01a_w_e4b7c973-9d08-4d7f-9e9a-5d16d15371a3.webp?v=1784299019"},{"product_id":"fluke-374-true-rms-acdc-clamp-meter-4mlxy","title":"FLUKE-374 True RMS AC\/DC Clamp Meter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 374 True-RMS Clamp Meter measures up to 600 A AC\/DC and 600 V, with optional iFlex™ probe support for expanded 2500 A AC range, and features a rugged ergonomic design with CAT IV 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-374 True RMS AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 374 True-RMS Clamp Meter delivers reliable, professional-grade performance for demanding electrical environments. Designed to handle complex signal conditions, this meter provides accurate AC\/DC current and voltage measurements up to 600 A and 600 V. True-RMS functionality ensures accuracy when working with non-linear loads, making it ideal for industrial, commercial, and HVAC applications.\u003c\/p\u003e\n\u003cp\u003eCompatible with the optional iFlex™ flexible current probe, the Fluke 374 allows expanded measurement capability up to 2500 A AC, offering improved access to tight or hard-to-reach conductors. Its robust ergonomic build supports safe one-handed operation—even while wearing PPE—while the large backlit display simplifies readings in low-light areas. Additional capabilities like inrush current capture, min\/max\/avg recording, and a soft carrying case make the 374 an essential tool in any electrician’s kit.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Accuracy:\u003c\/strong\u003e Ensures precise readings on non-linear loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex™ Compatibility:\u003c\/strong\u003e Expand current measurement to 2500 A AC (iFlex probe sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT IV 600 V Safety Rating:\u003c\/strong\u003e Maximum protection for industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Measurement:\u003c\/strong\u003e Filters out noise to capture motor start-up current accurately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e Easy one-handed operation, even with gloves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Range Selection:\u003c\/strong\u003e Eliminates manual switch changes for faster readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit Display:\u003c\/strong\u003e High visibility in dim work areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Recording:\u003c\/strong\u003e Min, Max, Average, and Inrush data capture functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e Soft carrying case and test leads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (Jaw):\u003c\/strong\u003e 600 A, ±2% ± 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (iFlex):\u003c\/strong\u003e 2500 A, ±3% ± 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e 600 A, ±2% ± 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e 600 V, ±1.5% ± 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e 600 V, ±1% ± 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 6000 Ω, ±1% ± 5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 1 μF to 1000 μF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Features:\u003c\/strong\u003e Large, easy-to-read backlit LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity:\u003c\/strong\u003e Audible detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Capacity:\u003c\/strong\u003e Up to 750 MCM or 2–500 MCM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Accessories:\u003c\/strong\u003e iFlex™ 10\" and 18\" flexible probes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024408551680,"sku":"FLUKE-374-NEW","price":409.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_8a60370a-0d6c-4246-b68b-52161ca3e598.webp?v=1784299021"},{"product_id":"fluke-87v-true-rms-industrial-multimeter-8st2p","title":"Fluke 87V True RMS Industrial Multimeter","description":"\u003cp\u003e[shortdesc] True-RMS accuracy, 1000 V AC\/DC, 10 A current range, VFD low-pass filter, 200 kHz frequency, CAT III 1000 V\/CAT IV 600 V [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 87V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Digital Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage (AC\/DC)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current (AC\/DC)\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003eUp to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003eUp to 9,999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eUp to 200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−200 °C to 1090 °C (probe dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductance\u003c\/td\u003e\n\u003ctd\u003eUp to 60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test Range\u003c\/td\u003e\n\u003ctd\u003e3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 counts (19,999 in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eTwo-level bright backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e9V battery (installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~400 hours (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0–90% (0–35 °C), 0–70% (35–55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e201 × 98 × 52 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e355 g (624 g with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e1 m drop (IEC 61010-1:2001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eMIL-PRF-28800 Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eMax 1000 V; Accuracy ±(0.05% + 1); Resolution 10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eMax 1000 V; Accuracy ±(0.7% + 2) True RMS; AC Bandwidth 20 kHz (LPF enabled); 3 dB @ 1 kHz; Resolution 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003eMax 10 A (20 A for 30 sec); Accuracy ±(0.2% + 2); Resolution 0.01 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003eMax 10 A (20 A for 30 sec); Accuracy ±(1.0% + 2) True RMS; Resolution 0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange up to 50 MΩ; Accuracy ±(0.2% + 1); Resolution 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eMax 9,999 µF; Accuracy ±(1% + 2); Resolution 0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eMax 200 kHz; Accuracy ±(0.005% + 1); Resolution 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eMax 99.9%; Accuracy ±(0.2% per kHz + 0.1%); Resolution 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd\u003e−200 °C to 1090 °C (meter); with 80BK probe: −40 °C to 260 °C; Accuracy ±2.2 °C or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductance\u003c\/td\u003e\n\u003ctd\u003eUp to 60.00 nS; Accuracy ±(1.0% + 10); Resolution 0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003eRange 3 V; Resolution 1 mV; Accuracy ±(2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Conditions\u003c\/td\u003e\n\u003ctd\u003eOperating: −20 °C to 55 °C; Storage: −40 °C to 60 °C; Humidity: 0–90% (0–35 °C), 0–70% (35–55 °C); Altitude: 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1 CAT III 1000 V \/ CAT IV 600 V; CE, CSA, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Performance\u003c\/td\u003e\n\u003ctd\u003eDigital 6000 counts (4\/sec), 19,999 high-res mode; Analog bar graph 32 segments (40\/sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (Standard Package)\u003c\/td\u003e\n\u003ctd\u003eTL75 Test Leads; AC175 Alligator Clips; Holster; 9V Battery (installed); 80BK Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (87V CAL Version)\u003c\/td\u003e\n\u003ctd\u003eAll standard items + Traceable calibration certificate with data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eFluke TPAK ToolPak Magnetic Meter Hanger; Fluke TLK-225 SureGrip Master Accessory Set; Fluke CXT80 Extreme Case; Fluke Pack30 Professional Tool Backpack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003ePrecision Diagnostics for Demanding Industrial Environments\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 87V Industrial Multimeter delivers the accuracy and resolution required to troubleshoot motor drives, power distribution panels, automation systems and electromechanical equipment even in noisy, high-energy environments. Its advanced low-pass filter ensures precise measurements on variable frequency drives (VFDs), while Peak Capture functionality identifies fast intermittents down to 250 µs for reliable problem isolation. Built to Fluke’s highest safety standards, the 87V withstands spikes above 8000 V and operates confidently in challenging field conditions.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS performance:\u003c\/strong\u003e Achieves accurate readings on complex, noisy or non-linear loads common in VFD and automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-pass VFD filter:\u003c\/strong\u003e Enables stable, precise voltage measurements on motor drives by filtering high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed peak capture:\u003c\/strong\u003e Detects intermittents as short as 250 µs, essential for monitoring unstable signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable industrial build:\u003c\/strong\u003e Rated CAT III 1000 V and CAT IV 600 V with specially designed shielding that blocks high-energy electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced visibility \u0026amp; usability:\u003c\/strong\u003e Features a bright two-level backlight, analog bar graph and Touch Hold for easier field work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTesting and diagnosing\u003cstrong\u003e \u003c\/strong\u003evariable-frequency motor drives\u003c\/li\u003e\n\u003cli\u003eIndustrial automation maintenance and plant operations\u003c\/li\u003e\n\u003cli\u003ePower distribution and electrical panel troubleshooting\u003c\/li\u003e\n\u003cli\u003eField service in high-energy or high-altitude environments (up to 2000 m operating altitude)\u003c\/li\u003e\n\u003cli\u003ePrecision testing for electromechanical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Measurement:\u003c\/strong\u003e 1000 V AC\/DC (True RMS ±0.7% + 2 AC; ±0.05% + 1 DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement:\u003c\/strong\u003e 10 A (20 A for 30 seconds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 50 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 9,999 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Up to 200 kHz (0.01 Hz resolution)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e 0–99.9%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e −200 °C to 1090 °C (meter only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000–19,999 counts, analog bar graph\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Approximately 400 hours (without backlight)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpgrade Your Test Precision Today\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder now\u003c\/strong\u003e and equip your toolkit with industry-leading accuracy.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024408846592,"sku":"FLUKE-87-V-NEW","price":561.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2725d18d-633b-40b2-b09b-b108002e4d59_original__size_6856c6eb-7777-4fb0-8510-34b1ae6942bd.webp?v=1784299025"},{"product_id":"fluke-279-fc-true-rms-thermal-multimeter-ivqbo","title":"Fluke 279 FC True-RMS Thermal Multimeter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 279 FC combines full-featured True-RMS multimeter functions with a built-in thermal imager, enabling fast fault detection and remote team collaboration through Fluke Connect®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 279 FC True-RMS Thermal Multimeter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 279 FC is a groundbreaking tool that integrates a full-featured digital multimeter with a thermal imaging camera, making it easier to detect, validate, and troubleshoot electrical problems in one device. This dual-function capability allows technicians to spot hot spots and anomalies quickly and then verify issues with precision electrical measurements—all without switching tools.\u003c\/p\u003e\n\u003cp\u003eWith wireless connectivity via the Fluke Connect® app, technicians can save, analyze, and share measurements and images in real time, enhancing safety and productivity. The built-in infrared camera helps locate issues faster by identifying overheating components like fuses, motors, or connections. Designed for demanding environments, the 279 FC is rugged, reliable, and ideal for industrial, HVAC, and facility maintenance professionals.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Thermal Imager:\u003c\/strong\u003e Pinpoint electrical hot spots and anomalies with the built-in infrared camera.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-Featured Multimeter:\u003c\/strong\u003e Measure voltage, current, resistance, continuity, capacitance, frequency, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluke Connect® Wireless:\u003c\/strong\u003e Transmit measurements and images wirelessly for remote monitoring and reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Display:\u003c\/strong\u003e 3.5\" color LCD shows thermal images and measurements simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Up to 10 hours of operation per charge with rechargeable lithium-ion battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rated:\u003c\/strong\u003e CAT III 1000 V, CAT IV 600 V for safe use in industrial and commercial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImage Storage:\u003c\/strong\u003e Store up to 100 images internally for later review and documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional iFlex® Probe Compatibility:\u003c\/strong\u003e Add-on current probe extends current measurement range and flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e 0.1 mV to 1000 V (±0.09%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage (True-RMS):\u003c\/strong\u003e 0.1 mV to 1000 V (±1%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e 0.1 µA to 10 A (±1%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (True-RMS):\u003c\/strong\u003e 0.1 µA to 10 A (±1.5%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 50 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Up to 100 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 10,000 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 3.5-inch (89 mm) color LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Imaging Resolution:\u003c\/strong\u003e 80 × 60 pixels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField of View:\u003c\/strong\u003e 38.0° × 28.5°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Sensitivity:\u003c\/strong\u003e ≤ 0.10 °C at 30 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImage Storage:\u003c\/strong\u003e Up to 100 images (.is2 format)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Fluke Connect® via Bluetooth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Type:\u003c\/strong\u003e Rechargeable lithium-ion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e ~10 hours per charge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 22.6 cm × 10 cm × 5.8 cm (8.9 in × 3.9 in × 2.3 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 870 g (1.9 lb)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024408879360,"sku":"Fluke-279FC-NEW","price":1584.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/F-279fc_03b_h1500X1000_0_2734a69b-4f20-4f45-89d7-be9a04805ae9.webp?v=1784299026"},{"product_id":"fluke-287-true-rms-electronics-logging-multimeter-with-trendcapture-tscnw","title":"FLUKE-287 True-RMS Electronics Logging Multimeter with TrendCapture","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 287 True-RMS Multimeter offers advanced logging with TrendCapture, high-resolution 50,000 count display, and real-time data analysis. Ideal for electronics professionals who demand accuracy and insight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-287 True-RMS Electronics Logging Multimeter with TrendCapture\u003c\/h1\u003e\n\u003cp\u003eThe FLUKE-287 is a powerful True-RMS multimeter designed for professional electronic technicians and engineers. With built-in TrendCapture technology, this meter allows users to log and graphically review data directly on its large 1\/4 VGA display, eliminating the need for a PC download. The multimeter provides up to 0.025% basic DC accuracy and a 100 kHz AC bandwidth, making it ideal for capturing complex signals and high-speed transients in demanding environments.\u003c\/p\u003e\n\u003cp\u003eIt features an expanded memory for unattended logging, a real-time clock for timestamping, and advanced triggering with customizable thresholds. The FLUKE-287 supports multiple measurement sessions, multilingual interface, onboard help menus, and can be paired with the Fluke Connect® app (via optional ir3000 FC adapter) for wireless sharing and team collaboration.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrendCapture:\u003c\/strong\u003e View graphical logged data sessions directly on-screen without a PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e 0.025% basic DC accuracy, 100 kHz AC bandwidth, and True-RMS AC measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Display:\u003c\/strong\u003e 50,000 count 1\/4 VGA LCD with white backlight; view multiple readings simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Logging:\u003c\/strong\u003e Store up to 15,000 recorded events; includes auto-threshold and recording triggers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Clock:\u003c\/strong\u003e Automatically timestamps saved readings for easier analysis and reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Measurements:\u003c\/strong\u003e Measures up to 1000 V, 10 A (20 A for 30 sec), 100 mF capacitance, temperature, frequency, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphing Multimeter:\u003c\/strong\u003e Zoom in on logged data up to 14x for deep trend analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Wireless Capability:\u003c\/strong\u003e Compatible with Fluke Connect® mobile app and ir3000 FC adapter (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Battery Life:\u003c\/strong\u003e Over 100 hours of operation; 200+ hours in logging mode with 6× AA batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e Premium test leads and alligator clips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Range:\u003c\/strong\u003e Up to 1000 V (±0.025% accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage Range:\u003c\/strong\u003e Up to 1000 V (True-RMS, ±0.4% accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC\/AC Current Range:\u003c\/strong\u003e Up to 10 A (20 A for 30 sec)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 500 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 100 mF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e -200°C to +1350°C (with probe)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Up to 999.99 kHz (±0.005%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 50,000 count, 1\/4 VGA LCD with backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogging Memory:\u003c\/strong\u003e Up to 15,000 events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 6 × AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 100 hours typical; 200+ hours in logging mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 22.2 cm × 10.2 cm × 6 cm (8.75 in × 4.03 in × 2.38 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 870.9 g (28 oz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024409075968,"sku":"FLUKE-287-NEW","price":904.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fluke-287-true-rms-1500x1000-1_d037ae7a-9201-4c13-9fcc-e79107524e7f.webp?v=1784299029"},{"product_id":"fluke-375-fc-true-rms-acdc-clamp-meter-ulkcx","title":"Fluke 375 FC True-RMS AC\/DC Clamp Meter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 375 FC is a wireless-enabled True-RMS clamp meter designed to measure AC\/DC current up to 600 A (2500 A with optional iFlex®), featuring VFD low-pass filtering, Bluetooth connectivity, and advanced diagnostics for demanding electrical environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 375 FC True-RMS AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 375 FC True-RMS Clamp Meter offers advanced performance for professionals who require precise and reliable electrical testing. Part of the Fluke Connect® wireless family, this meter allows real-time data transmission to your smartphone or tablet, enabling safer testing outside the arc flash zone. With a VFD low-pass filter for accurate motor drive measurements and compatibility with the optional iFlex® probe for expanded current capacity, the 375 FC is ideal for industrial and commercial diagnostics. Capture inrush currents, trend measurements, and share results via the cloud or ShareLive™ video calls — all with a rugged tool designed for field use.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluke Connect® Enabled:\u003c\/strong\u003e Wirelessly view and log measurements from a distance using your mobile device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement Range:\u003c\/strong\u003e Up to 600 A with fixed jaw, or 2500 A AC with optional iFlex® flexible probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVFD Low-Pass Filter:\u003c\/strong\u003e Enables accurate measurement of variable frequency drive signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Accuracy:\u003c\/strong\u003e Reliable performance on non-linear loads and noisy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Measurement Capability:\u003c\/strong\u003e AC\/DC voltage, current, resistance, frequency, capacitance, and mV DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin\/Max\/Avg and Inrush Recording:\u003c\/strong\u003e Captures electrical variations automatically for detailed diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certified:\u003c\/strong\u003e CAT III 1000 V \/ CAT IV 600 V for enhanced user protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Durable:\u003c\/strong\u003e 34 mm jaw opening, IP30-rated casing, and ergonomic design built for field work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e Soft carrying case, batteries, test leads, and instruction manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (via jaw):\u003c\/strong\u003e 600.0 A, Accuracy: ±2% ±5 digits (10–100 Hz), ±2.5% ±5 digits (100–500 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (via iFlex®):\u003c\/strong\u003e 2500 A, Accuracy: ±3% ±5 digits (5–500 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e 600.0 A, Accuracy: ±2% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e 1000 V, Accuracy: ±1.5% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e 1000 V, Accuracy: ±1% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emV DC:\u003c\/strong\u003e 500.0 mV, Accuracy: ±1% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 60 kΩ, Accuracy: ±1% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 1000 μF, Accuracy: ±1% ±4 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 5.0 Hz to 500.0 Hz, Accuracy: ±0.5% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 34 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 249 x 85 x 45 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 395 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e 2 AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 1000 V \/ CAT IV 600 V (IEC 61010-1, 61010-2-032)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP30 (non-operating)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024420741376,"sku":"FLUKE-375FC-NEW","price":613.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/f-375-01d-1500x1000_3045fda9-f6c5-4c5e-9fd0-d0b0e571cbf2.webp?v=1784299073"},{"product_id":"fluke-374-fc-true-rms-acdc-clamp-meter-w2fgz","title":"Fluke 374 FC True-RMS AC\/DC Clamp Meter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 374 FC is a True-RMS clamp meter with wireless connectivity, capable of measuring AC\/DC current up to 600 A (or 2500 A with optional iFlex®), offering safe, accurate diagnostics with Fluke Connect compatibility and remote data logging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 374 FC True-RMS AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 374 FC True-RMS Clamp Meter combines powerful electrical measurement capabilities with Fluke Connect® wireless technology for enhanced safety and productivity. Designed for commercial and industrial electricians, this clamp meter allows users to measure AC\/DC current up to 600 A with the fixed jaw, or up to 2500 A with the optional iFlex® flexible current probe. Fluke Connect enables remote reading and data logging from a safe distance, reducing the need for personal protective equipment in hazardous environments. With true-RMS accuracy, capacitance, resistance, voltage, and frequency measurements, the 374 FC is a versatile, durable tool.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Connectivity:\u003c\/strong\u003e Fluke Connect® enables live readings and data transfer via Bluetooth for enhanced safety and collaboration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex® Ready:\u003c\/strong\u003e Optional flexible current probe extends AC current measurement up to 2500 A and improves access in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Accuracy:\u003c\/strong\u003e Accurate measurements on non-linear loads for reliable diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurement Range:\u003c\/strong\u003e Measures AC\/DC current (up to 600 A), voltage (up to 1000 V), resistance, capacitance, and frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Logging and Reporting:\u003c\/strong\u003e Log and trend measurements, generate reports, and share via ShareLive™ video calls or email.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT IV Safety:\u003c\/strong\u003e Rated CAT III 1000 V and CAT IV 600 V for safe operation in high-energy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Durable:\u003c\/strong\u003e Ergonomic design with backlit display, 34 mm jaw opening, and rugged build for field use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes Accessories:\u003c\/strong\u003e Comes with TL75 test leads, soft carrying case, and two AA batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (via jaw):\u003c\/strong\u003e 600.0 A, Accuracy: 2% ±5 digits (10–100 Hz), 2.5% ±5 digits (100–500 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (via iFlex®):\u003c\/strong\u003e 2500 A, Accuracy: 3% ±5 digits (5–500 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e 600.0 A, Accuracy: 2% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e 1000 V, Accuracy: 1.5% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e 1000 V, Accuracy: 1% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emV DC:\u003c\/strong\u003e Range: 500.0 mV, Accuracy: 1% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 6000 Ω, Accuracy: 1% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 1000 μF, Accuracy: 1% ±4 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Up to 500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Hold \/ Min\/Max \/ Inrush:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 34 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 249 x 85 x 45 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 395 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e 2 AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to +50°C (14°F to 122°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 1000 V \/ CAT IV 600 V (IEC 61010-1, 61010-2-032, 61010-2-033)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP30 (non-operating)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024421036288,"sku":"FLUKE-374FC-NEW","price":534.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-374-DIJITAL-AMPERMETRE-OLCU-ALETI-FLUKE-374-3_683cefe5-8255-4b18-9ddb-bfbf4e0b4929.jpg?v=1784299079"},{"product_id":"fluke-381-true-rms-acdc-clamp-meter-with-iflex-do6wa","title":"FLUKE-381 True RMS AC\/DC Clamp Meter with iFlex","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 381 is a True RMS AC\/DC clamp meter with a detachable wireless display and iFlex™ probe, offering current measurements up to 2500 A and exceptional flexibility for one-person operation in tight or hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-381 True RMS AC\/DC Clamp Meter with iFlex\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 381 True RMS Clamp Meter with iFlex redefines flexibility in electrical diagnostics. Featuring a detachable, wireless display, this clamp meter allows one technician to measure safely and efficiently — even at a distance of up to 30 feet. The included iFlex™ flexible current probe extends measurement capabilities up to 2500 A AC and improves access to awkward or tight conductors. Designed for demanding industrial environments, it includes a low-pass filter and advanced signal processing to ensure accurate readings in noisy settings. With built-in Min\/Max\/Inrush capture and a bright backlit display, the Fluke 381 delivers a safe and efficient workflow for professionals working with high current systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable Wireless Display:\u003c\/strong\u003e Monitor live readings from up to 30 feet away for safer and more convenient testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Current Measurement:\u003c\/strong\u003e iFlex™ probe supports AC current up to 2500 A with improved conductor access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurement Functions:\u003c\/strong\u003e AC\/DC current, AC\/DC voltage, resistance, frequency, and continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Accuracy:\u003c\/strong\u003e Reliable results on non-linear and noisy signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Build:\u003c\/strong\u003e Rugged design with ergonomic grip, suitable for use with protective equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Features:\u003c\/strong\u003e Includes Min\/Max\/Average\/Inrush, hold function, and low-pass filter for motor applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit Display:\u003c\/strong\u003e Auto-ranging, easy-to-read screen with magnetic mount option for hands-free use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified Safety:\u003c\/strong\u003e CAT III 1000 V \/ CAT IV 600 V rating for high protection standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes Accessories:\u003c\/strong\u003e 18-inch iFlex™ flexible current probe and a soft carrying case.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (via jaw):\u003c\/strong\u003e 999.9 A, Accuracy: ±2% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (via iFlex):\u003c\/strong\u003e 2500 A, Accuracy: ±3% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e 999.9 A, Accuracy: ±2% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e 1000 V, Accuracy: ±1.5% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e 1000 V, Accuracy: ±1.0% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 60,000 Ω, Accuracy: ±1.0% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Up to 500 Hz, Accuracy: ±0.5% ±5 digits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity:\u003c\/strong\u003e Audible detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e Captures motor start current as seen by protection circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Pass Filter:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHold Function:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Large backlit with auto-ranging and magnetic mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Range:\u003c\/strong\u003e Up to 30 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Capacity:\u003c\/strong\u003e 750 MCM or 2–500 MCM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024421167360,"sku":"FLUKE-381-NEW","price":922.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/f-381-04e-1500x1000_3448ea91-fb19-4738-ab28-d9563e06d0b4.webp?v=1784299080"},{"product_id":"fluke-323-true-rms-clamp-meter-tyloe","title":"FLUKE-323 True RMS Clamp Meter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 323 True RMS Clamp Meter is a compact, rugged tool designed for reliable AC current, voltage, and resistance measurements up to 400 A, ideal for commercial and residential troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFLUKE-323 True RMS Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe FLUKE-323 True RMS Clamp Meter offers a practical and precise solution for\u003cimg\u003e electricians needing reliable measurements in tight spaces. With True RMS sensing, this clamp meter ensures accurate readings on non-linear loads, making it perfect for commercial and residential troubleshooting. The meter measures AC current up to 400 A, AC and DC voltage up to 600 V, and resistance up to 4 kΩ. Its ergonomic design and large display provide ease of use, while the built-in data hold function captures readings for later reference. The FLUKE-323 is CAT III 600 V and CAT IV 300 V rated, ensuring high safety standards in demanding environments.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Accuracy:\u003c\/strong\u003e Ensures precise measurements even on non-linear loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Current Measurement:\u003c\/strong\u003e Measures AC current up to 400 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e AC and DC voltage measurements up to 600 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Ergonomic:\u003c\/strong\u003e Slim design allows for easy operation in confined cable compartments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Display:\u003c\/strong\u003e Easy-to-read screen with a data hold function for capturing readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for Field Use:\u003c\/strong\u003e Rugged construction designed for harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified Safety:\u003c\/strong\u003e CAT III 600 V and CAT IV 300 V safety ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e Comes with test leads, a soft carrying case, and a user manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current:\u003c\/strong\u003e 400.0 A (±2% ±5 digits at 45–65 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e 600.0 V (±1.5% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e 600.0 V (±1.0% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 400 Ω \/ 4000 Ω (±1.0% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity:\u003c\/strong\u003e ≤70 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Response:\u003c\/strong\u003e True RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Hold Function:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 207 x 75 x 34 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 265 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Wire Diameter:\u003c\/strong\u003e 30 mm (600 MCM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT III 600 V, CAT IV 300 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024421495040,"sku":"FLUKE-323-NEW","price":198.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/f-323-01c-1500x1000_420db64a-5a9d-4d0b-a01c-a2e904b46d25.webp?v=1784299084"},{"product_id":"fluke-376fc-true-rms-clamp-meter-with-iflex-exyjw","title":"FLUKE-376FC True RMS Clamp Meter with iFlex","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376 FC is a versatile true-RMS clamp meter with iFlex, offering advanced troubleshooting capabilities, wireless connectivity, and extended current range up to 2500 A AC with enhanced safety features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 376 FC True-RMS Clamp Meter with iFlex\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 376 FC is a high-performance clamp meter designed for industrial and commercial electricians. With integrated iFlex technology and wireless compatibility through the Fluke Connect app, it allows users to safely capture, log, and trend measurements from a distance. It supports true-RMS AC\/DC current and voltage measurements, frequency, resistance, capacitance, and inrush current, making it an essential tool for professional diagnostics and maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Measurement:\u003c\/strong\u003e Delivers accurate readings on non-linear loads including variable speed drives and electronic ballasts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex Flexible Current Probe:\u003c\/strong\u003e Extends measurement range up to 2500 A AC and provides access in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluke Connect Compatible:\u003c\/strong\u003e Wirelessly transmit readings to your smartphone or tablet for safe and remote monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Low-Pass Filter:\u003c\/strong\u003e Ideal for accurate motor drive measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Measurement:\u003c\/strong\u003e Captures motor startup current as seen by the circuit breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rated:\u003c\/strong\u003e CAT IV 600 V, CAT III 1000 V for high-level protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultifunctional Testing:\u003c\/strong\u003e Measures AC\/DC voltage, resistance, continuity, capacitance, frequency, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Rugged Design:\u003c\/strong\u003e Includes magnetic hanging strap, soft case, test leads, and iFlex probe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current via Jaw:\u003c\/strong\u003e 999.9 A (Accuracy: ±2% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current via iFlex:\u003c\/strong\u003e Up to 2500 A (Accuracy: ±3% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e 999.9 A (Accuracy: ±2% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage:\u003c\/strong\u003e Up to 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 1000 μF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency via Jaw or iFlex:\u003c\/strong\u003e 5.0 Hz to 500.0 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emV DC Measurement:\u003c\/strong\u003e Up to 500 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Backlit digital display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Function:\u003c\/strong\u003e Fluke Connect app via Bluetooth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Type:\u003c\/strong\u003e 2 x AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10 °C to +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 249 x 85 x 45 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 395 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 34 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eiFlex Cable Length:\u003c\/strong\u003e 1.8 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e CAT III 1000 V \/ CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP30 (non-operating)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024421462272,"sku":"FLUKE-376FC-NEW","price":660.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/f-376-02e-1500x1000_6ddff944-a623-4be8-980c-d1da4c242955.webp?v=1784299084"},{"product_id":"fluke-1587-fc-insulation-multimeter-labrk","title":"Fluke-1587-FC Insulation Multimeter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1587 FC is a high-performance insulation multimeter that combines a digital insulation tester with a full-featured, true-RMS digital multimeter, ideal for troubleshooting and preventative maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"359\" style=\"border-collapse: collapse; width: 843px;\" height=\"573\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"154\" style=\"width: 395px;\"\u003e \u003ccol width=\"205\" style=\"width: 447px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"196\" data-end=\"294\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eProperty\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"205\" style=\"width: 154pt;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"154\" style=\"height: 16.8pt; width: 115pt;\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eFluke 1587 FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"495\" data-end=\"593\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e2-in-1 Insulation Multimeter with True-RMS DMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"594\" data-end=\"692\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"154\" style=\"height: 16.8pt; width: 115pt;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e6000-count backlit display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"693\" data-end=\"792\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"154\" style=\"height: 16.8pt; width: 115pt;\"\u003eInsulation Test Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e0.01 MΩ to 2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"793\" data-end=\"892\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"154\" style=\"height: 16.8pt; width: 115pt;\"\u003eInsulation Test Voltages\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"893\" data-end=\"991\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eVFD Low-Pass Filter\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eYes (for accurate motor drive measurements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"992\" data-end=\"1090\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003ePI\/DAR Ratio with Graphing\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eYes (via Fluke Connect app)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1091\" data-end=\"1189\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1190\" data-end=\"1288\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eFrequency Measurement\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1289\" data-end=\"1387\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1388\" data-end=\"1486\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eDiode Test\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1487\" data-end=\"1585\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eContinuity Test\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eAudible tone below 25 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1586\" data-end=\"1684\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eSafety Rating\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1685\" data-end=\"1783\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e4x AA (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1784\" data-end=\"1882\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e1000 hours (DMM); 1000 insulation tests (5s on\/25s off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1883\" data-end=\"1981\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eIP40 (non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1982\" data-end=\"2081\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eDimensions (H x W x L)\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2082\" data-end=\"2180\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2181\" data-end=\"2279\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e-20°C to +55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2280\" data-end=\"2378\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e-40°C to +60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"2379\" data-end=\"2477\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eAltitude (Operating \/ Storage)\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e2000 m \/ 12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003cbr\u003e\u003c\/p\u003e\n\u003ctable height=\"607\" style=\"border-collapse: collapse; width: 845px;\" width=\"359\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 396px;\" width=\"154\"\u003e \u003ccol style=\"width: 447px;\" width=\"205\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"2709\" data-start=\"2610\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 115pt;\" width=\"154\" class=\"xl65\" height=\"19\"\u003eSpecification\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"22\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003eUp to 1000 V (True-RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3012\" data-start=\"2912\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"22\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3113\" data-start=\"3013\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"22\"\u003eMillivolts (DC)\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e600.0 mV, ±(0.1 % + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3214\" data-start=\"3114\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"22\"\u003eAC\/DC Current\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e60 mA \/ 400 mA ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3315\" data-start=\"3215\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"22\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e0.1 Ω to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3416\" data-start=\"3316\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eFrequency Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003eUp to 99.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3517\" data-start=\"3417\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"19\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003eUp to 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3618\" data-start=\"3518\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e-40°C to +537°C \/ -40°F to +998°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3719\" data-start=\"3619\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"19\"\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e+20%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3821\" data-start=\"3720\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eInsulation Test Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e±(1.5% + 5 counts) up to 600 MΩ, ±(10% + 3 counts) to 2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3922\" data-start=\"3822\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eShort Circuit Test Current\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4023\" data-start=\"3923\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"19\"\u003eAuto Discharge\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e\u0026lt;0.5 seconds (for ≤1 μF load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4124\" data-start=\"4024\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"19\"\u003eLive Circuit Detection\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003eInhibits insulation test \u0026gt; 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4225\" data-start=\"4125\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eFuse Protection\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e0.44A, 1000 V, IR 10 kA (mA input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4325\" data-start=\"4226\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eOver-range Capability\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e110% of range (except capacitance: 100%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4426\" data-start=\"4326\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eFrequency Overload Protection\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e\u0026lt;107 V-Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4527\" data-start=\"4427\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"19\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e10 MΩ (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4628\" data-start=\"4528\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003eIEC 61326-1, IEC 61326-2-2, CISPR 11 Group 1 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4728\" data-start=\"4629\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 115pt;\" width=\"154\" class=\"xl66\" height=\"38\"\u003eRF Communication (Wireless)\u003c\/td\u003e\n\u003ctd style=\"width: 154pt;\" width=\"205\" class=\"xl66\"\u003e2.4 GHz ISM Band (FCC\/IC Certified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e[\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 1587 FC Insulation Multimeter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 1587 FC is a versatile 2-in-1 insulation multimeter that provides accurate insulation resistance testing along with true-RMS digital multimeter functions. With insulation test voltages ranging from 50V to 1000V, it can measure insulation resistance up to 2 GΩ, making it suitable for industrial applications. Featuring Fluke Connect compatibility, users can remotely monitor test results via a smartphone for enhanced safety and efficiency.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Insulation Testing:\u003c\/strong\u003e Measures insulation resistance from 0.01 MΩ to 2 GΩ with test voltages of 50V, 100V, 250V, 500V, and 1000V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Digital Multimeter:\u003c\/strong\u003e Offers AC\/DC voltage, AC\/DC current, resistance, continuity, capacitance, frequency, and temperature measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluke Connect Wireless Compatibility:\u003c\/strong\u003e Enables remote monitoring, historical tracking, and real-time decision-making.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive Circuit Detection:\u003c\/strong\u003e Prevents insulation testing if voltage is greater than 30V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Pass Filter (VFD Mode):\u003c\/strong\u003e Provides accurate motor drive measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-Discharge Function:\u003c\/strong\u003e Ensures user safety by automatically discharging capacitive voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin\/Max and Auto-Hold Features:\u003c\/strong\u003e Records signal fluctuations for easy data analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT IV 600V \/ CAT III 1000V Safety Rating:\u003c\/strong\u003e Designed for industrial and commercial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Backlit Display:\u003c\/strong\u003e Provides easy visibility in low-light environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged \u0026amp; Portable:\u003c\/strong\u003e Supplied with a hard case, remote probe, test leads, alligator clips, and K-type thermocouple for comprehensive testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage Measurement:\u003c\/strong\u003e Up to 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e 0.01 MΩ to 2 GΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltages:\u003c\/strong\u003e 50V, 100V, 250V, 500V, 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Measurement:\u003c\/strong\u003e Up to 9999 μF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Measurement:\u003c\/strong\u003e Up to 99.99 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Measurement:\u003c\/strong\u003e -40°C to 537°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Fluke Connect Wireless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Up to 1000 hours of meter use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000-count backlit digital display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Four AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT IV 600V \/ CAT III 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e 5.0 cm H x 10.0 cm W x 20.3 cm L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 550g (1.2 lb)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024426017024,"sku":"Fluke-1587-FC-NEW","price":1069.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/652_1_f961cb23-b660-4a58-8f35-0ccc6cbdf4b4.jpg?v=1784299100"},{"product_id":"fluke-77-iv-industrial-digital-multimeter-5lg9u","title":"Fluke-77-IV Industrial Digital Multimeter","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 77-IV is a versatile digital multimeter designed for industrial maintenance, field service, and bench repair, featuring high accuracy and robust safety compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"359\" style=\"border-collapse: collapse; width: 849px;\" height=\"687\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"154\" style=\"width: 398px;\"\u003e \u003ccol width=\"205\" style=\"width: 450px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"182\" data-end=\"279\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eProperty\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"205\" style=\"width: 154pt;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"154\" style=\"height: 16.8pt; width: 115pt;\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eFluke 77-IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"477\" data-end=\"574\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eDigital Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"575\" data-end=\"672\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e6000-count digital display with 33-segment bar graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"673\" data-end=\"770\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eVoltage Measurement Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eUp to 1000 V (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"771\" data-end=\"868\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eCurrent Measurement Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eUp to 10 A (for 30 seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"869\" data-end=\"966\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eContinuity Test\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eAudible beep \u0026lt;25 Ω, detects 250 µs opens\/shorts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"967\" data-end=\"1064\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eResistance Measurement\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eUp to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1065\" data-end=\"1162\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eUp to 9999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1163\" data-end=\"1260\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eFrequency Measurement\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e2 Hz to 99.99 kHz (AC voltage input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1261\" data-end=\"1358\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eMIN\/MAX\/AVG Function\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eAvailable for tracking signal variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1359\" data-end=\"1456\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1457\" data-end=\"1554\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1555\" data-end=\"1652\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"154\" style=\"height: 28.8pt; width: 115pt;\"\u003ePower Source\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e9V battery (installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1653\" data-end=\"1750\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e400 hours typical (alkaline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1751\" data-end=\"1848\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eDimensions (H x W x L)\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e4.3 x 9 x 18.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1849\" data-end=\"1946\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1947\" data-end=\"2044\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2045\" data-end=\"2142\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2143\" data-end=\"2240\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2241\" data-end=\"2338\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"154\" style=\"height: 14.4pt; width: 115pt;\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"205\" style=\"width: 154pt;\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003cbr\u003e\u003c\/p\u003e\n\u003ctable height=\"491\" style=\"border-collapse: collapse; width: 952px;\" width=\"518\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 502.5px;\" width=\"286\"\u003e \u003ccol style=\"width: 449.5px;\" width=\"232\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"2469\" data-start=\"2372\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 214pt;\" width=\"286\" class=\"xl65\" height=\"19\"\u003eSpecification\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"476\" data-start=\"379\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"22\"\u003eDC Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e0.1 mV to 1000 V ±(0.3% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2766\" data-start=\"2668\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eAC Voltage (Avg Responding)\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e0.001 V to 1000 V ±(2.0% + 2) (45 Hz – 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2865\" data-start=\"2767\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eDC Current\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e0.01 mA to 10.00 A ±(1.5% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2964\" data-start=\"2866\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eAC Current (Avg Responding)\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e0.01 mA to 10.00 A ±(2.5% + 2) (45 Hz – 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3062\" data-start=\"2965\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003eUp to 50 MΩ ±(0.5% to 2.0%) depending on range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3161\" data-start=\"3063\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e1 nF to 9999 µF ±(1.2% + 2) to ±10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3260\" data-start=\"3162\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e0.01 Hz to 99.99 kHz ±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3359\" data-start=\"3261\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eDiode Test\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e2.400 V max, ±(1.0% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3457\" data-start=\"3360\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eFuse Protection (mA input)\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e440 mA, 1000 V fast fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3555\" data-start=\"3458\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eFuse Protection (A input)\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e11 A, 1000 V fast fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3653\" data-start=\"3556\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eBurden Voltage (typical)\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e2 mV\/mA (400 mA), 37 mV\/A (10 A input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3751\" data-start=\"3654\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eOverload Capability\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e400 mA up to 600 mA; \u0026gt;10 A not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3850\" data-start=\"3752\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 214pt;\" width=\"286\" class=\"xl66\" height=\"38\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd style=\"width: 174pt;\" width=\"232\" class=\"xl66\"\u003e0.1 x specified accuracy \/ °C outside 18–28°C range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e[\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 77-IV Industrial Digital Multimeter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 77-IV is a rugged and reliable digital multimeter designed for industrial and commercial applications. With a broad measurement range, advanced features, and high safety compliance, this multimeter is ideal for electricians, technicians, and engineers working in demanding environments.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage Range:\u003c\/strong\u003e Measures up to 1000V AC\/DC with ±0.3% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement:\u003c\/strong\u003e Supports up to 10A AC\/DC with overload protection (20A for 30 seconds).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance \u0026amp; Continuity:\u003c\/strong\u003e Measures resistance up to 50MΩ with audible continuity test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance \u0026amp; Frequency:\u003c\/strong\u003e Capable of measuring capacitance up to 9,999μF and frequency up to 99.99kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Digital Display:\u003c\/strong\u003e 6000-count LCD with a 33-segment analog bar graph for real-time readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto \u0026amp; Manual Ranging:\u003c\/strong\u003e Ensures accurate measurements with selectable ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin\/Max Recording:\u003c\/strong\u003e Captures signal fluctuations over time for troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Safety Compliance:\u003c\/strong\u003e Rated for CAT III 1000V and CAT IV 600V environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Design:\u003c\/strong\u003e Rugged, ergonomic build for one-handed operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Battery Life:\u003c\/strong\u003e Provides up to 400 hours of operation on a 9V battery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Range:\u003c\/strong\u003e 6.000V – 1000V (±0.3% + 1 digit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage Range:\u003c\/strong\u003e 600.0mV – 1000V (±2.0% + 2 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current Range:\u003c\/strong\u003e 60.00mA – 10A (±1.5% + 2 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current Range:\u003c\/strong\u003e 60.00mA – 10A (±2.5% + 2 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 600.0Ω – 50MΩ (±0.5% + 1 digit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 1nF – 9,999μF (±1.2% + 2 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 99.99Hz – 99.99kHz (±0.1% + 1 digit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity Test:\u003c\/strong\u003e Audible beep below 25Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000-count LCD with 4 updates\/sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT III 1000V \/ CAT IV 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 400 hours (typical, alkaline)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4.3 x 9 x 18.5 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 420 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024426049792,"sku":"Fluke-77-IV-NEW","price":462.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/F_77_IV_01b_h_1500x1000_1_bce4b950-ae6b-47a9-b655-60170634030c.webp?v=1784299100"},{"product_id":"fluke-922-airflow-metermicromanometer-fluke-922-gzfgq","title":"Fluke 922 Airflow Meter\/Micromanometer (FLUKE-922)","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 922 Airflow Meter\/Micromanometer is a rugged and versatile tool for diagnosing HVAC ventilation issues, measuring air pressure, velocity, and airflow with high precision\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003cdiv dir=\"auto\" data-message-id=\"790ce206-711e-433a-ba6b-3931ff8d63c4\" data-message-author-role=\"user\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable height=\"698\" style=\"border-collapse: collapse; width: 1000px;\" width=\"381\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 536px;\" width=\"227\"\u003e \u003ccol style=\"width: 464px;\" width=\"154\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"278\" data-start=\"180\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl65\" height=\"19\"\u003eProperty\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eFluke 922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"576\" data-start=\"478\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eAirflow Meter \/ Micromanometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"676\" data-start=\"577\" style=\"height: 43.2pt;\" height=\"58\"\u003e\n\u003ctd style=\"height: 43.2pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"58\"\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eDifferential and static pressure, air velocity, airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"776\" data-start=\"677\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eBacklit digital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"876\" data-start=\"777\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eDuct Configuration\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eUser-defined shape and size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"979\" data-start=\"877\" style=\"height: 43.2pt;\" height=\"58\"\u003e\n\u003ctd style=\"height: 43.2pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"58\"\u003eMeasurement Units\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003ePascals, inH₂O, mmH₂O, mbar, PSI, fpm, m\/s, cfm, m³\/hr, l\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1079\" data-start=\"980\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eData Storage\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e99 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1179\" data-start=\"1080\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e4 x AA (1.5V Alkaline) batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1278\" data-start=\"1180\" style=\"height: 43.2pt;\" height=\"58\"\u003e\n\u003ctd style=\"height: 43.2pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"58\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e~375 hours (no backlight), ~80 hours (with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1378\" data-start=\"1279\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1478\" data-start=\"1379\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1578\" data-start=\"1479\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e0% to 90% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1678\" data-start=\"1579\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1778\" data-start=\"1679\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eAltitude (Operating \/ Storage)\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e2000 m \/ 12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1878\" data-start=\"1779\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1978\" data-start=\"1879\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eVibration Standard\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eMIL-PREF-28800F, Class 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2078\" data-start=\"1979\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eMax Pressure per Port\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e10 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications] \u003cbr\u003e\u003c\/p\u003e\n\u003cdiv data-message-author-role=\"user\" data-message-id=\"790ce206-711e-433a-ba6b-3931ff8d63c4\" dir=\"auto\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"381\" style=\"border-collapse: collapse; width: 1099px;\" height=\"448\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"227\" style=\"width: 585.5px;\"\u003e \u003ccol width=\"154\" style=\"width: 512.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2112\" data-end=\"2211\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"227\" style=\"height: 14.4pt; width: 170pt;\"\u003eSpecification\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"154\" style=\"width: 115pt;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"58\" style=\"height: 43.2pt;\"\u003e\n\u003ctd height=\"58\" class=\"xl67\" width=\"227\" style=\"height: 43.2pt; width: 170pt;\"\u003eAir Pressure\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e±4000 Pa \/ ±16 inH₂O \/ ±400 mmH₂O \/ ±40 mbar \/ ±0.6 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"2414\" data-end=\"2514\"\u003e\n\u003ctd height=\"38\" class=\"xl67\" width=\"227\" style=\"height: 28.8pt; width: 170pt;\"\u003eAir Velocity\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e250 to 16,000 fpm \/ 1 to 80 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"2515\" data-end=\"2615\"\u003e\n\u003ctd height=\"38\" class=\"xl67\" width=\"227\" style=\"height: 28.8pt; width: 170pt;\"\u003eAir Flow (Volume)\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e0 to 99,999 cfm \/ m³\/hr \/ l\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"2616\" data-end=\"2716\"\u003e\n\u003ctd height=\"38\" class=\"xl67\" width=\"227\" style=\"height: 28.8pt; width: 170pt;\"\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"58\" style=\"height: 43.2pt;\" data-start=\"2717\" data-end=\"2818\"\u003e\n\u003ctd height=\"58\" class=\"xl67\" width=\"227\" style=\"height: 43.2pt; width: 170pt;\"\u003eResolution - Pressure\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e1 Pa \/ 0.001 inH₂O \/ 0.1 mmH₂O \/ 0.01 mbar \/ 0.0001 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2819\" data-end=\"2919\"\u003e\n\u003ctd height=\"22\" class=\"xl67\" width=\"227\" style=\"height: 16.8pt; width: 170pt;\"\u003eResolution - Velocity\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e1 fpm \/ 0.001 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2920\" data-end=\"3020\"\u003e\n\u003ctd height=\"22\" class=\"xl67\" width=\"227\" style=\"height: 16.8pt; width: 170pt;\"\u003eResolution - Volume\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e1 cfm \/ 1 m³\/hr \/ 1 l\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"3021\" data-end=\"3121\"\u003e\n\u003ctd height=\"22\" class=\"xl67\" width=\"227\" style=\"height: 16.8pt; width: 170pt;\"\u003eResolution - Temperature\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"3122\" data-end=\"3222\"\u003e\n\u003ctd height=\"38\" class=\"xl67\" width=\"227\" style=\"height: 28.8pt; width: 170pt;\"\u003eAccuracy - Pressure\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e±1% + 1 Pa (or unit equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"3223\" data-end=\"3323\"\u003e\n\u003ctd height=\"38\" class=\"xl67\" width=\"227\" style=\"height: 28.8pt; width: 170pt;\"\u003eAccuracy - Velocity\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e±2.5% of reading at 2000 fpm (10.00 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"3324\" data-end=\"3424\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"227\" style=\"height: 14.4pt; width: 170pt;\"\u003eAccuracy - Temperature\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"154\" style=\"width: 115pt;\"\u003e±1% + 2°C \/ ±1% + 4°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e[\/specifications]\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable height=\"184\" style=\"border-collapse: collapse; width: 1089px;\" width=\"381\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 580.5px;\" width=\"227\"\u003e \u003ccol style=\"width: 507.5px;\" width=\"154\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"3546\" data-start=\"3455\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl65\" height=\"19\"\u003eAccessory\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eRubber Hoses\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e2 included with Fluke 922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3822\" data-start=\"3731\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eWrist Strap\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3914\" data-start=\"3823\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eAA Batteries\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e4x AA (1.5V Alkaline) included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4006\" data-start=\"3915\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eUser Manual\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4098\" data-start=\"4007\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eSoft Carrying Case\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eIncluded with standard Fluke 922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch1\u003eFluke 922 Airflow Meter\/Micromanometer (FLUKE-922)\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 922 is a professional-grade airflow meter designed for HVAC technicians and industrial applications. Combining differential and static pressure, air velocity, and airflow readings into a single device, it enables accurate troubleshooting of ventilation systems. The meter allows users to enter duct shape and dimensions for maximum measurement accuracy, ensuring proper airflow balance and indoor air quality. Its rugged design is built for field use, and a bright backlit display provides clear visibility in all environments.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-in-One Measurement:\u003c\/strong\u003e Simultaneously measures differential and static pressure, air velocity, and airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged \u0026amp; Portable:\u003c\/strong\u003e Durable construction for field use with a soft carrying case.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Compatible with most pitot tubes for reliable duct traversals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit Display:\u003c\/strong\u003e Ensures visibility in all working conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Storage:\u003c\/strong\u003e Stores up to 99 readings for easy reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power Off:\u003c\/strong\u003e Extends battery life for long-term use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Pressure Measurement:\u003c\/strong\u003e ±4000 Pascals, ±16 in H2O, ±400 mm H2O, ±40 mbar, ±0.6 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Velocity Range:\u003c\/strong\u003e 250 to 16,000 fpm (1 to 80 m\/s)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow Measurement:\u003c\/strong\u003e 0 to 99,999 cfm, 0 to 99,999 m³\/hr, 0 to 99,999 l\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 0°C to 50°C (32°F to 122°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C (32°F to 122°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 60°C (-40°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0% to 90% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e Up to 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Altitude:\u003c\/strong\u003e Up to 12,000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pressure at Each Port:\u003c\/strong\u003e 10 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Storage:\u003c\/strong\u003e 99 readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 375 hours (without backlight), 80 hours (with backlight)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 4 AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets EN61326-1 standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Portable and lightweight for convenient use\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024428933376,"sku":"FLUKE-922-NEW","price":1207.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fluke-922-376-1_1400x_50b02bc5-8317-48c2-b567-539018d45cdd.webp?v=1784299109"},{"product_id":"fluke-400a-ac-current-clamp-fluke-i400-0mqsb","title":"Fluke 400A AC Current Clamp (Fluke-i400)","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke i400 AC Current Clamp is a high-accuracy, CAT IV-rated clamp accessory designed for digital multimeters, allowing safe and precise AC current measurements up to 400A without breaking the circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable height=\"326\" style=\"border-collapse: collapse; width: 917px;\" width=\"381\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 494.5px;\" width=\"227\"\u003e \u003ccol style=\"width: 421.5px;\" width=\"154\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"268\" data-start=\"170\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl65\" height=\"19\"\u003eProperty\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eFluke i400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"567\" data-start=\"469\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eAC Current Clamp Accessory for DMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"667\" data-start=\"568\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eNominal Current Range\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"767\" data-start=\"668\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eContinuous Current Range\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e1 A to 400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"867\" data-start=\"768\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eMax. Conductor Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e32 mm (1.25 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"967\" data-start=\"868\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eMax. Conductor Size (Busbar)\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e750 MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1067\" data-start=\"968\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eOutput Level\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e1 mA\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1167\" data-start=\"1068\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eOutput Cable Length\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e1.5 m (59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1266\" data-start=\"1168\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eOutput Termination\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eShrouded banana plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1366\" data-start=\"1267\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eSafety Rating\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1466\" data-start=\"1367\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eMax. Voltage to Earth\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e1000 V AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"493\" style=\"border-collapse: collapse; width: 983px;\" height=\"282\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"207\" style=\"width: 452.5px;\"\u003e \u003ccol width=\"286\" style=\"width: 530.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"1500\" data-end=\"1599\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"207\" style=\"height: 14.4pt; width: 155pt;\"\u003eSpecification\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"286\" style=\"width: 214pt;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"369\" data-end=\"468\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"207\" style=\"height: 28.8pt; width: 155pt;\"\u003eMaximum Non-Destructive Current\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e1000 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"1802\" data-end=\"1902\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"207\" style=\"height: 28.8pt; width: 155pt;\"\u003eMinimum Measurable Current\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e1 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"1903\" data-end=\"2003\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e±(2% of reading + 0.06 A) @ 45–400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2004\" data-end=\"2104\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e5 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2105\" data-end=\"2205\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003eEN61010 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e[\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 400A AC Current Clamp (Fluke-i400)\u003c\/h1\u003e\n\u003cp\u003eThe Fluke i400 AC Current Clamp is a reliable and high-safety clamp meter accessory designed to work with digital multimeters for accurate AC current measurements up to 400A. With a 1 mA\/Amp output, it ensures easy readings on compatible meters while providing CAT IV 600V and CAT III 1000V safety ratings. This clamp enables current measurements without disconnecting live circuits, enhancing safety and efficiency for electrical professionals. The non-slip, overmolded handle ensures a secure grip, and its compact design makes it easy to use in tight spaces.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A AC Current Measurement:\u003c\/strong\u003e Measures AC currents from 1A to 400A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT IV 600V \/ CAT III 1000V Safety Rating:\u003c\/strong\u003e Industry-leading safety compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 mA\/A Output:\u003c\/strong\u003e Ensures easy and accurate readings on digital multimeters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Measurement:\u003c\/strong\u003e Enables safe current measurements without breaking the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft Overmolded Handle:\u003c\/strong\u003e Provides a non-slip grip for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Lightweight:\u003c\/strong\u003e Designed for easy handling and use in confined spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Current Range:\u003c\/strong\u003e 400A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Current Range:\u003c\/strong\u003e 1A - 400A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Non-Destructive Current:\u003c\/strong\u003e 1000A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLowest Measurable Current:\u003c\/strong\u003e 1A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBasic Accuracy:\u003c\/strong\u003e ±2% + 0.06A (45-400Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsable Frequency Range:\u003c\/strong\u003e 5Hz - 20kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Level:\u003c\/strong\u003e 1mA\/A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 1000V AC rms from earth to ground (EN61010 compliant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Conductor Diameter:\u003c\/strong\u003e 32mm (1.25 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Conductor Size (Busbar):\u003c\/strong\u003e 750 MCM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Cable Length:\u003c\/strong\u003e 1.5m (59 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Shrouded banana plugs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024428998912,"sku":"Fluke-i400-NEW","price":231.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/634912066__1_01cf22d7-85e1-440d-919a-85ad91776bb6.webp?v=1784299108"},{"product_id":"fluke-365-detachable-jaw-true-rms-acdc-clamp-meter-fluke-365-kncrb","title":"Fluke 365 Detachable Jaw True RMS AC\/DC Clamp Meter (FLUKE-365)","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 365 Detachable Jaw True RMS AC\/DC Clamp Meter is a compact and rugged meter designed for jobs requiring access to hard-to-reach wires\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003cdiv dir=\"auto\" data-message-id=\"790ce206-711e-433a-ba6b-3931ff8d63c4\" data-message-author-role=\"user\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable height=\"384\" style=\"border-collapse: collapse; width: 1102px;\" width=\"381\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 587px;\" width=\"227\"\u003e \u003ccol style=\"width: 514px;\" width=\"154\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"286\" data-start=\"188\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl65\" height=\"19\"\u003eProperty\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eFluke 365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"584\" data-start=\"486\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eTrue-RMS AC\/DC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"683\" data-start=\"585\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eAC\/DC up to 200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"782\" data-start=\"684\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eVoltage Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eAC\/DC up to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"881\" data-start=\"783\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eResistance Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eUp to 6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"980\" data-start=\"882\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eContinuity Detection\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1079\" data-start=\"981\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eTrue-RMS\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1178\" data-start=\"1080\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eDetachable Jaw\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eYes (for better access and visibility)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1277\" data-start=\"1179\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"22\"\u003eFlashlight\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eBuilt-in LED torch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1376\" data-start=\"1278\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eBacklit digital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1475\" data-start=\"1377\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"38\"\u003eAuto Range\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eYes (auto-ranging function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1574\" data-start=\"1476\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eMax Wire Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003e17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1673\" data-start=\"1575\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 170pt;\" width=\"227\" class=\"xl66\" height=\"19\"\u003eSafety Rating\u003c\/td\u003e\n\u003ctd style=\"width: 115pt;\" width=\"154\" class=\"xl66\"\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[specifications] \u003cbr\u003e\u003c\/p\u003e\n\u003cdiv data-message-author-role=\"user\" data-message-id=\"790ce206-711e-433a-ba6b-3931ff8d63c4\" dir=\"auto\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"493\" style=\"border-collapse: collapse; width: 1101px;\" height=\"299\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"207\" style=\"width: 511.5px;\"\u003e \u003ccol width=\"286\" style=\"width: 589.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"207\" style=\"height: 14.4pt; width: 155pt;\"\u003eSpecification\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"286\" style=\"width: 214pt;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2007\" data-end=\"2106\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0–200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"2107\" data-end=\"2206\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"207\" style=\"height: 28.8pt; width: 155pt;\"\u003eDC Current Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0–200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2207\" data-end=\"2306\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eAC\/DC Current Resolution\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2307\" data-end=\"2406\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eAC\/DC Current Accuracy\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e±2% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2407\" data-end=\"2506\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0–600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2507\" data-end=\"2606\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0–600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2607\" data-end=\"2706\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eVoltage Resolution\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"2707\" data-end=\"2806\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"207\" style=\"height: 28.8pt; width: 155pt;\"\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e±2% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 16.8pt;\" data-start=\"2807\" data-end=\"2906\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"207\" style=\"height: 16.8pt; width: 155pt;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0–6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\" data-start=\"2907\" data-end=\"3006\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"207\" style=\"height: 14.4pt; width: 155pt;\"\u003eResistance Resolution\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.8pt;\" data-start=\"3007\" data-end=\"3106\"\u003e\n\u003ctd height=\"38\" class=\"xl66\" width=\"207\" style=\"height: 28.8pt; width: 155pt;\"\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"286\" style=\"width: 214pt;\"\u003e±1% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable height=\"142\" data-end=\"3567\" data-start=\"3137\" style=\"border-collapse: collapse; width: 922px;\" width=\"374\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 505.5px;\" width=\"232\"\u003e \u003ccol style=\"width: 415.5px;\" width=\"142\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"3207\" data-start=\"3137\" style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 174pt;\" width=\"232\" class=\"xl65\" height=\"19\"\u003eAccessory\u003c\/td\u003e\n\u003ctd style=\"width: 106pt;\" width=\"142\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3351\" data-start=\"3280\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 174pt;\" width=\"232\" class=\"xl66\" height=\"22\"\u003eTest Leads\u003c\/td\u003e\n\u003ctd style=\"width: 106pt;\" width=\"142\" class=\"xl66\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3423\" data-start=\"3352\" style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; width: 174pt;\" width=\"232\" class=\"xl66\" height=\"38\"\u003eDetachable Clamp Jaw\u003c\/td\u003e\n\u003ctd style=\"width: 106pt;\" width=\"142\" class=\"xl66\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3495\" data-start=\"3424\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 174pt;\" width=\"232\" class=\"xl66\" height=\"22\"\u003eSoft Carrying Case\u003c\/td\u003e\n\u003ctd style=\"width: 106pt;\" width=\"142\" class=\"xl66\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3567\" data-start=\"3496\" style=\"height: 16.8pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.8pt; width: 174pt;\" width=\"232\" class=\"xl66\" height=\"22\"\u003eUser Manual\u003c\/td\u003e\n\u003ctd style=\"width: 106pt;\" width=\"142\" class=\"xl66\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eFluke 365 Detachable Jaw True RMS AC\/DC Clamp Meter (FLUKE-365)\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 365 is a high-performance clamp meter designed for industrial and electrical professionals who require a tool capable of measuring AC\/DC current up to 200A with precision. Its detachable jaw feature, connected via a flexible lead, allows for easy wire access and enhanced visibility of the display. This meter also includes a built-in flashlight, making it ideal for working in low-light environments. With True RMS technology, it provides accurate readings even in noisy electrical conditions, ensuring reliability and efficiency in every application.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200A AC\/DC Current Measurement:\u003c\/strong\u003e Accurate current readings with a detachable jaw for improved accessibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e600V AC\/DC Voltage Measurement:\u003c\/strong\u003e Wide voltage range with high precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Technology:\u003c\/strong\u003e Ensures accurate measurements in noisy electrical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable Jaw:\u003c\/strong\u003e Flexible 900mm cable allows for easy wire access and enhanced display viewing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Flashlight:\u003c\/strong\u003e Illuminates work areas for better visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Durable:\u003c\/strong\u003e Designed for use with protective equipment and fits comfortably in hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Range Selection:\u003c\/strong\u003e Adjusts measurement range without manual switching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current:\u003c\/strong\u003e 200.0A (Accuracy: ±2% ±5 digits at 45-65Hz, ±2.5% ±5 digits at 65-400Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current:\u003c\/strong\u003e 200.0A (Accuracy: ±2% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e 600.0V (Accuracy: ±1.5% ±5 digits at 45-400Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage:\u003c\/strong\u003e 600.0V (Accuracy: ±1% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 600.0Ω \/ 6000Ω (Accuracy: ±1% ±5 digits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrest Factor:\u003c\/strong\u003e 2.5 @ 125A, 1.55 @ 200A (Add 2% for C.F. \u0026gt;2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e 18mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable Jaw Cable Length:\u003c\/strong\u003e 900mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Large backlit LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2 AA batteries (NEDA 15A, IEC LR6)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Extended operation for long-term use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e Non-condensing (≤10°C), 90% RH (10-30°C), 75% RH (30-40°C), 45% RH (40-50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Altitude:\u003c\/strong\u003e 12,000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance \u0026amp; Safety:\u003c\/strong\u003e EN\/IEC 61010-1 CAT III 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 225 x 65 x 46mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 275g (including batteries)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024429031680,"sku":"FLUKE-365-NEW","price":356.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/f-365-01b-1500x1000_f028d201-871d-4cb9-b824-474b498931b0.webp?v=1784299109"},{"product_id":"fluke-289-trendcapture-trms-industrial-logging-multimeter-fluke-289-3tqgd","title":"Fluke 289 TrendCapture TRMS Industrial Logging Multimeter (Fluke-289)","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 289 TRMS Industrial Logging Multimeter is a high-precision tool designed for troubleshooting complex electrical systems, real-time graphing with TrendCapture technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003cdiv data-message-author-role=\"user\" data-message-id=\"790ce206-711e-433a-ba6b-3931ff8d63c4\" dir=\"auto\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"590\" style=\"border-collapse: collapse; width: 853px;\" height=\"454\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"227\" style=\"width: 359px;\"\u003e \u003ccol width=\"363\" style=\"width: 494px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\"\u003e\n\u003ctd height=\"26\" class=\"xl65\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eProperty\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"363\" style=\"width: 272pt;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"416\" data-end=\"519\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eFluke 289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"520\" data-end=\"623\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eTrue-RMS Industrial Logging Multimeter with TrendCapture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"624\" data-end=\"727\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003e50,000-count 1\/4 VGA graphic display with white backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"728\" data-end=\"831\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eData Logging\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eYes – up to 10,000 readings with TrendCapture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"832\" data-end=\"935\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eLogging Duration\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eOver 200 hours continuous logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"936\" data-end=\"1039\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eTrend Analysis\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eOn-device graphical viewing of logged data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1040\" data-end=\"1143\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eInput Impedance Mode\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eLoZ (low impedance) to avoid ghost voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1144\" data-end=\"1247\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eLow-Pass Filter\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eFor noisy environments and motor drive applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1248\" data-end=\"1351\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eLow Ohms Measurement\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003e50 Ω range, 1 mΩ resolution, 10 mA source current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1352\" data-end=\"1455\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eInterface\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eSoft keys and scroll navigation, customizable display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1456\" data-end=\"1559\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eSaved Measurements\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eYes – with field recall and naming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1560\" data-end=\"1663\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eTrue-RMS\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eYes (AC voltage and current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1664\" data-end=\"1767\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eBacklight \u0026amp; Flashlight\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eBacklight display only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.95pt;\" data-start=\"1768\" data-end=\"1871\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 19.95pt; width: 170pt;\"\u003eFirmware\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt;\"\u003eField-upgradable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003cdiv dir=\"auto\" data-message-id=\"790ce206-711e-433a-ba6b-3931ff8d63c4\" data-message-author-role=\"user\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable height=\"454\" style=\"border-collapse: collapse; width: 1096px;\" width=\"537\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 484.5px;\" width=\"205\"\u003e \u003ccol style=\"width: 610.5px;\" width=\"332\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-end=\"2007\" data-start=\"1905\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl65\" height=\"26\"\u003eSpecification\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl65\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"519\" data-start=\"416\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003eUp to 1000 V (basic accuracy: ±0.025%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2317\" data-start=\"2215\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003eUp to 1000 V (accuracy: ±0.4% True-RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2420\" data-start=\"2318\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eDC Current Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003eUp to 10 A (accuracy: ±0.15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2523\" data-start=\"2421\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003eUp to 10 A (accuracy: ±0.7% True-RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2626\" data-start=\"2524\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003eUp to 500 MΩ (accuracy: ±0.05%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2729\" data-start=\"2627\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003e1 nF to 100 mF (accuracy: ±1.0%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2832\" data-start=\"2730\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003eUp to 999.99 kHz (accuracy: ±0.005%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2936\" data-start=\"2833\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003e-200 °C to +1350 °C (accuracy: ±1% + 2 °C) (probe excl.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3039\" data-start=\"2937\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eContinuity \/ Diode\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3142\" data-start=\"3040\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eConductance\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003e0.01 nS to 50.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3245\" data-start=\"3143\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003e1% to 99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3348\" data-start=\"3246\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003ePeak\/Crest Capture\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003e250 μs peak min\/max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3451\" data-start=\"3349\" style=\"mso-height-source: userset; height: 19.95pt;\" height=\"26\"\u003e\n\u003ctd style=\"height: 19.95pt; width: 154pt;\" width=\"205\" class=\"xl66\" height=\"26\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd style=\"width: 249pt;\" width=\"332\" class=\"xl66\"\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"590\" style=\"border-collapse: collapse; width: 1201px; height: 256px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"227\" style=\"width: 533px;\"\u003e \u003ccol width=\"363\" style=\"width: 668px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\" data-start=\"120\" data-end=\"204\"\u003e\n\u003ctd height=\"26\" class=\"xl65\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003eAccessory\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003eTest Leads (TLK289)\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003eElectronic Test Lead Kit (included in the box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\" data-start=\"375\" data-end=\"459\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003eSoft Case (C781)\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003eProtective soft meter case (included in the box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\" data-start=\"460\" data-end=\"544\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003eUser Manual\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003ePrinted documentation (included in the box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\" data-start=\"545\" data-end=\"629\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003e6x AA Batteries\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003eFor operation (included in the box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\" data-start=\"630\" data-end=\"714\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003eFlukeView Forms Software\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003eFor PC data logging and analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\" data-start=\"715\" data-end=\"799\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003ei400 Current Clamp\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003eAC current clamp accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"height: 26.6px;\" data-start=\"800\" data-end=\"884\"\u003e\n\u003ctd height=\"26\" class=\"xl66\" width=\"227\" style=\"height: 26.6px; width: 170pt;\"\u003eTPAK Magnetic Hanger\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"363\" style=\"width: 272pt; height: 26.6px;\"\u003eHands-free hanging solution for meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch1\u003eFluke 289 TrendCapture TRMS Industrial Logging Multimeter (Fluke-289)\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 289 is a next-generation high-performance industrial multimeter designed for troubleshooting and maintenance in plant automation, power distribution, and electro-mechanical equipment. With its advanced TrendCapture feature, users can log data and analyze it directly on the device's large 50,000-count display. The built-in low pass filter ensures accurate voltage and frequency measurements even in noisy environments, and the expanded logging memory allows for unattended monitoring over time. With real-time clock-stamped data, on-board help screens, and an optically isolated communication port, the Fluke 289 is the perfect watchdog for industrial professionals.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Data Logging:\u003c\/strong\u003e Stores up to 15,000 readings for long-term monitoring and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrendCapture Technology:\u003c\/strong\u003e Graphically displays logged data to quickly identify anomalies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Display:\u003c\/strong\u003e Large 50,000-count VGA display with a white backlight for easy readability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS Accuracy:\u003c\/strong\u003e Provides precise AC voltage and current measurements on non-linear loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Impedance (LoZ) Mode:\u003c\/strong\u003e Eliminates ghost voltages and enhances testing accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto \u0026amp; Manual Logging:\u003c\/strong\u003e Adjustable recording and auto-hold thresholds allow for flexible data collection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Meets MIL-PRF-28800F Class 2 vibration standards and withstands 1-meter drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePC Connectivity:\u003c\/strong\u003e Supports data transfer via an optically isolated USB port (software optional).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Measurement:\u003c\/strong\u003e 50.000 mV to 1000.0 V (±0.025% accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage Measurement:\u003c\/strong\u003e 50.000 mV to 1000.0 V (±0.4% true-RMS accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current Measurement:\u003c\/strong\u003e 500.00 µA to 10.000 A (±0.15% accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current Measurement:\u003c\/strong\u003e 500.00 µA to 10.000 A (±0.7% true-RMS accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 50.000 Ω to 500.0 MΩ (±0.05% accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 1.000 nF to 100 mF (±1.0% accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 99.999 Hz to 999.99 kHz (±0.005% accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) (±1.0% accuracy, probe dependent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 100 hours typical, 200 hours in logging mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 6 AA alkaline batteries (NEDA 15A IEC LR6)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 870.9 g (28 oz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 60°C (-40°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e EMC EN61326-1, IEC\/EN 61010-1 2nd Edition\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024429293824,"sku":"Fluke-289-NEW","price":1023.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fluke-289_70424755-7362-42d3-a255-ae48d3699171.webp?v=1784299113"},{"product_id":"fluke-922-airflow-metermicromanometer-kit-fluke-922kit-muhkx","title":"Fluke 922 Airflow Meter\/Micromanometer Kit (FLUKE-922\/KIT)","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 922 Airflow Meter\/Micromanometer Kit is a rugged, field-ready device combining pressure, airflow, and velocity measurements, ideal for HVAC diagnostics and air quality assessments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 922 Airflow Meter\/Micromanometer Kit (FLUKE-922\/KIT)\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 922 Airflow Meter\/Micromanometer Kit simplifies HVAC diagnostics by integrating pressure, airflow, and velocity measurements into a single device. It features user-defined duct shapes and sizes for maximum measurement accuracy, making it an essential tool for professionals. The rugged design ensures durability in field applications, and the backlit display provides clear readings in any environment. With additional functions such as Min\/Max\/Average\/Hold and auto power-off, it is both efficient and user-friendly. The kit includes a 12-inch pitot tube, rubber hoses, a wrist strap, and a carrying case for convenience.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Measurements:\u003c\/strong\u003e Combines differential and static pressure, air velocity, and flow readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged and Reliable:\u003c\/strong\u003e Built for field use with a durable design and bright backlit display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Functions:\u003c\/strong\u003e Includes Min\/Max\/Average\/Hold for comprehensive data analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Readings:\u003c\/strong\u003e User-defined duct shapes and sizes ensure precise airflow measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient Accessories:\u003c\/strong\u003e Includes a 12-inch pitot tube and a carrying case for portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e Auto power-off feature extends battery life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Pressure:\u003c\/strong\u003e ±4000 Pascals; ±16 in H2O; ±40 mbar (accuracy: ±1%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Velocity:\u003c\/strong\u003e 250 to 16,000 fpm (accuracy: ±2.5%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow:\u003c\/strong\u003e 0 to 99,999 cfm (accuracy varies with duct size)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C (32°F to 122°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 375 hours (without backlight), 80 hours (with backlight)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e Pitot tube, hoses, wrist strap, and carrying case\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Bright backlit for clear visibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source:\u003c\/strong\u003e Four AA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Compact and lightweight for easy handling\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024475365632,"sku":"FLUKE-922\/KIT-NEW","price":1181.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/71TYVkjSHyL._AC_UL960_QL65_d33322d9-d5c2-454c-851e-c38966a7da54.jpg?v=1784299340"},{"product_id":"fluke-789-4-20-ma-loop-calibrator-and-processmeter-fluke-789-sdepw","title":"Fluke 789 4-20 mA Loop Calibrator and ProcessMeter (FLUKE-789)","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 789 ProcessMeter combines the features of a multimeter and a loop calibrator, providing technicians with a powerful tool for current loop testing and troubleshooting in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[specifications] [\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 789 4-20 mA Loop Calibrator and ProcessMeter (FLUKE-789)\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 789 ProcessMeter is designed to enhance productivity by combining digital multimeter and current loop calibrator functions into one device. This tool is ideal for process control technicians and engineers who need to measure, source, and simulate mA signals with high accuracy. The device supports simultaneous mA and percentage readouts, along with advanced features like a 24V loop power supply, making it suitable for industrial troubleshooting applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultimeter and Calibrator Combination:\u003c\/strong\u003e Combines true-RMS digital multimeter functions with a 20 mA loop calibrator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement:\u003c\/strong\u003e Measures, sources, and simulates current up to 20 mA with over-range support up to 24 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V Loop Power:\u003c\/strong\u003e Provides 24V loop power supply for current loop testing and calibration (789 model only).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Data Logging:\u003c\/strong\u003e Compatible with Fluke Connect™ for wireless data logging and monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e Safety-rated for CAT IV 600V\/CAT III 1000V industrial environments with a durable build.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual and Automatic Step Functions:\u003c\/strong\u003e Features 100%, 25%, coarse, fine, auto-step, and auto-ramp adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Up to 140 hours typical for measurement operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Measurement:\u003c\/strong\u003e AC\/DC, up to 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Output:\u003c\/strong\u003e 0 to 20 mA or 4 to 20 mA with selectable over-range to 24 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Measurement:\u003c\/strong\u003e Up to 40 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Power Output:\u003c\/strong\u003e 24V DC (789 model only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 50 mm x 100 mm x 203 mm (1.97 in x 3.94 in x 8.00 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 600 grams (1.3 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e Four AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49024487751936,"sku":"Fluke-789-NEW","price":1557.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/789_c_nr-2887-1500x1000_c444f0ea-5f17-4ada-976f-cca400b70093.webp?v=1784299362"}],"url":"https:\/\/alotechparts.com\/collections\/fluke-parts.oembed?page=5","provider":"Alo Tech Solutions","version":"1.0","type":"link"}